My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6300 MERRILL CREEK PKY 2021 SAFRAN Plans 2022-12-01
>
Address Records
>
MERRILL CREEK PKY
>
6300
>
SAFRAN
>
Plans
>
6300 MERRILL CREEK PKY 2021 SAFRAN Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 11:33:28 AM
Creation date
7/20/2022 3:30:08 PM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
6300
Tenant Name
SAFRAN
Permit
B2104-080
Year
2021
Notes
ENCLOSE PRODUCT DISPLAY AREA AND USE EQUIPMENT LAB / ADD WALL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br />1. EXISTING BUILDING CONSTRUCTION PROVIDES EXAMPLE OF FINISH LEVEL TO BE PROVIDED. ALL WORK IS TO BE COMPATIBLE WITH EXISTING CONSTRUCTION. <br />2. ALL WORK SHALL CONFORM TO APPLICABLE CURRENT FEDERAL, STATE AND LOCAL CODES. THE CONTRACTOR IS TO PROVIDE FOR ALL REQUIRED NOTIFICATION OF AND COORDINATION WITH THE CITY AND STATE AGENCIES, AND PROVIDE REQUIRED PERMITS. ALL TESTS AND <br />INSPECTIONS ASSOCIATED WITH OBTAINING APPROVALS TO PROCEED WITH AND COMPLETE THE WORK SHALL BE PAID FOR BY THE CONTRACTOR. <br />3. THE INTENT OF THE CONTRACT DOCUMENTS IS TO INCLUDE ALL LABOR AND MATERIALS, EQUIPMENT AND TRANSPORTATION NECESSARY OR REASONABLY INFERABLE AS BEING NECESSARY FOR THE EXECUTION OF THE WORK. BY SUBMITTING A PROPOSAL, THE CONTRACTOR REPRESENTS <br />THAT THROUGH EXAMINATION OF THE SITE AND ALL EXISTING CONDITIONS AND LIMITATIONS HAVE BEEN MADE AND THAT THE CONTRACT DOCUMENTS HAVE BEEN EXAMINED IN COMPLETE DETAIL, AND THAT IT IS DETERMINED BEYOND DOUBT THAT THE DRAWINGS, SPECIFICATIONS AND <br />EXISTING CONDITIONS ARE SUFFICIENT, ADEQUATE AND SATISFACTORY FOR CONSTRUCTION OF THE WORK. WHERE MINOR ADJUSTMENTS TO THE WORK ARE NECESSARY FOR THE PURPOSES OF FABRICATION AND INSTALLATION OF ITEMS, OR RESOLUTIONS OF CONFLICTS BETWEEN ITEMS, <br />WITHIN THE INTENT OF THE CONTRACT DOCUMENTS, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AT NO ADDED EXPENSE TO THE OWNER. WHERE SUCH MINOR ADJUSTMENTS AFFECT FUNCTIONAL OR AESTHETIC DESIGN OF THE WORK, THEY SHALL BE SUBMITTED TO THE ARCHITECT <br />FOR REVIEW AND APPROVAL. <br />4. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER, INCLUDING AREA FOR WORK, MATERIALS STORAGE, ACCESS TO AND FROM THE WORK, SPECIAL CONDITIONS OR NOISY WORK, TIMING OF WORK AND INTERRUPTIONS OF MECHANICAL AND ELECTRICAL SERVICES. <br />5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE HIGHEST STANDARD OF WORKMANSHIP IN GENERAL AND WITH SUCH STANDARDS AS ARE SPECIFIED. <br />6. CONTRACTOR SHALL ADHERE TO ALL BUILDING STANDARDS. ANY CHANGE TO SAME SHALL BE SUBMITTED TO ARCHITECT IN WRITING FOR REVIEW AND APPROVAL. <br />7. CONTRACTOR SHALL SUBMIT SAMPLES OF ALL FINISHES OF SUCH SIZE AND NUMBER THAT THEY REPRESENT A REASONABLE DISTRIBUTION OF COLOR RANGE AND PATTERN PRIOR TO INSTALLATION FOR ARCHITECT'S APPROVAL. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS AND <br />PRODUCT DATA FOR ARCHITECT'S APPROVAL ON ALL SPECIAL ITEMS REQUIRING CUSTOM FABRICATION. <br />8. CONTRACTOR IS TO VERIFY ALL DIMENSIONS AND CONDITIONS ON SITE AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. CONTRACTOR IS NOT TO SCALE DRAWINGS. <br />9. CONTRACTOR SHALL PROVIDE SOLID WOOD BLOCKING IN PARTITIONS FOR ALL WALL MOUNTED FIXTURES AND DEVICES UNLESS INDICATED OTHERWISE ON THE DRAWINGS. <br />10. ALL MATERIALS INDICATED TO MATCH EXISTING SHALL DO SO WITH RESPECT TO SIZE, COLOR, TEXTURE, PATTERN, QUALITY AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE AND SHALL BE APPROVED BY THE ARCHITECT BEFORE USE. <br />11. EXISTING WORK DAMAGED AS A RESULT OF WORK UNDER THIS CONTRACT SHALL BE REPAIRED TO ORIGINAL CONDITION AND FINISHED TO MATCH ADJACENT FINISHES, SUBJECT TO ARCHITECT'S APPROVAL, AT NO ADDITIONAL COST TO OWNER. ALL REPLACEMENT MATERIAL REQUIRED <br />TO MATCH EXISTING MATERIALS SHALL DO SO WITH RESPECT TO TYPE, PATTERN, TEXTURE, SIZE, SHAPE, COLOR AND METHOD OF INSTALLATION INSOFAR AS PRACTICABLE, AND SHALL BE APPROVED BY THE ARCHITECT AND OWNER PRIOR TO INSTALLATION. <br />12. ALL EXISTING MECHANICAL AND ELECTRICAL EQUIPMENT AND SERVICE DISRUPTED OR REMOVED DURING CONSTRUCTION SHALL BE RESTORED AND REPLACED UNLESS NOTED OTHERWISE. <br />13. INSTALLATIONS OF MECHANICAL, ELECTRICAL AND STRUCTURAL SYSTEMS WILL REQUIRE OPENING OF SOME EXISTING WALLS, CEILINGS, OR FLOOR CAVITIES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF THESE OPENINGS TO MATCH EXISTING, EXCEPT WHERE NOTED <br />OTHERWISE. FILL ALL HOLES AND VOIDS IN FLOORS, WALLS AND CEILINGS WHICH RESULT FROM INSTALLATION OF WORK, AND REMOVAL OF EXISTING MATERIALS AND EQUIPMENT REQUIRED BY THIS CONTRACT. PATCHED AREAS SHALL MATCH THE MATERIALS, FINISHES, AND LEVELS <br />ADJACENT, OR SHALL BE PUT IN THE PROPER CONDITION TO RECEIVE THE FINISH INDICATED. <br />14. MEP TO COORDINATE WITH TENANT FOR ALL REQUIRED POWER, VENTING AND PLUMBING REQUIREMENTS (UNDER SEPARATE PERMIT). <br />� '.�� 12'-0" -TOP ..OF <br />' CEILING FRAMING. <br />EXISTING DEMISING <br />WALL: <br />5/8" TYPE "X" <br />GWB EACH SIDE <br />OF 6" METAL <br />STUDS AT 16" <br />O.C. WITH SOUND <br />BATT INSULATION. <br />ALTERNATE: <br />PROVIDE ADDITIONAL <br />LAYER 5/8" TYPE <br />"X" GWB TO INSIDE <br />FACE OF WEST <br />WALL OF SOUND <br />ROOM. <br />ADJACENT TENANT <br />(EXTERIOR WALL <br />SIMILAR CONDITION) <br />" ' 0-0FINISH FLOOR <br />3 <br />G t <br />NOTE: POST (2) SIGNS STATING <br />"NO STORAGE ON TOP OF THIS <br />ROOM". PLACE ONE ON EAST <br />WALL AND ONE ON SOUTH <br />WALL OF NEWLY CREATED ROOM. <br />CEILING DESIGNED FOR <br />MECHANICAL ACCESS ON TOP OF <br />ROOM BY MECHANICAL <br />TECHNICIAN ONLY. NO STORAGE <br />OR EQUIPMENT ALLOWED. <br />1000T150-43 CONTINUOUS <br />METAL TRACK W/ #8 SCREWS <br />EA SIDE AT EACH SIDE <br />EACH STUD. <br />NOTE: PAINT ALL GWB EXPOSED <br />TO VIEW. <br />NOTE: PROVIDE 1 1 /2" <br />CLEARANCE FROM EXISTING <br />DEMISING WALL TO NEW WALL OF <br />VIBE TABLE ROOM. (END WALL <br />ADJACENT TO EXTERIOR WALL <br />SIMILAR CONDITION) <br />MAKE NO PHYSICAL CONNECTION. <br />60OS162-43 METAL STUDS <br />16" O.C. WITH 5/8" PLYWOOD <br />SHEATING WITH 7/8" <br />RESILIENT FURRING CHANNELS <br />AT 24" O.C. WITH (2) LAYERS <br />5/8" TYPE "X" GWB WITH <br />LEVEL 4 FINISH AT INTERIOR <br />SIDE W/ 6" SOUND BATT <br />INSULATION. <br />NEW VIBE TABLE ROOM <br />60OT150-43 CONT. METAL <br />TRACK W/ 1 /4" HILTI PINS <br />AT 8" O.C. INTO CONC. (1) <br />#8 SCREW EACH SIDE <br />EACH STUD. <br />4" RUBBER BASE AT ALL <br />NEW WALLS. <br />0' 0"...FINISH.._.FLOOR. <br />SECTION THROUGH VIBE TABLE ROOM <br />Scale: 1 /2"-1'-0" <br />PROVIDE NEW EXIST SIGN — <br />WITH BATTERY BACK UP AND <br />EMERGENCY LIGHTING. <br />LOCATE DOOR TIGHT TO --- <br />NORTH JAMB OF EXISTING <br />OPENING. <br />ENLARGED P <br />EQUIPMENT <br />LAB <br />120 <br />PROVIDE NEW 12'-0" WIDE x 10'-0" HIGH <br />COILING DOOR WITH CHAIN HOIST LIFT ON <br />EXISTING 12'-0" WIDE x 10'-0" HIGH <br />CONCRETE OPENING. PAINT TO MATCH <br />EXISTING HOLLOW METAL DOORS. <br />� 20 <br />OPEN <br />OFFICE <br />121 <br />x INFILL EXISTING 5' WIDE x 8'-0" HIGH <br />20 OPENING IN CONCRETE WALL. PROVIDE <br />5/8" TYPE 'T GWB EACH SIDE OF <br />3 5/8" METAL STUDS AT 16" O.C. WITH <br />SOUND BATT INSULATION. PROVIDE 3'-0" x <br />J_J <br />7'-0" HOLLOW METAL DOOR AND FRAME <br />WITH TEMPERED GLASS VIEW PANEL. <br />PROVIDE LEVER LOCKSET AND CLOSER. <br />PAINT WALL AND DOOR TO MATCH EXISTING. <br />RUBBER BASE EACH SIDE OF WALL. <br />LAN AT EQUIPMENT LAB <br />Scale: 1 /8"=1 '-0 <br />1000T150-43 CONTINUOUS <br />METAL TRACK W/ #8 SCREWS <br />EA SIDE AT EACH SIDE <br />EACH STUD. <br />(2) #8 SCREWS TO EACH <br />JOIST <br />60OT150-43 CONTINUOUS <br />METAL TRACK W/ #8 SCREWS <br />EA SIDE AT EACH SIDE <br />EACH STUD. <br />-1000S162-43 METAL JOISTS <br />© 16" O.C. WITH 5/8" <br />PLYWOOD SHEATING WITH <br />7/8" RESILIENT FURRING <br />CHANNELS AT 24" O.C. WITH <br />(2) LAYERS 5/8" TYPE "X" <br />GWB WITH LEVEL 4 FINISH AT <br />INTERIOR SIDE W/ 6" SOUND <br />BATT INSULATION, 3/4" <br />PLYWOOD DECK ON TOP OF <br />ROOM. <br />60OS162-43 METAL STUDS <br />16" O.C. WITH 5/8" PLYWOOD <br />SHEATING WITH 7/8" <br />RESILIENT FURRING CHANNELS <br />AT 24" O.C. WITH (2) LAYERS <br />5/8" TYPE "X" GWB WITH <br />LEVEL 4 FINISH AT INTERIOR <br />SIDE W/ 6" SOUND BATT <br />INSULATION, 5/8" TYPE "X" <br />GWB WITH LEVEL 4 FINISH AT <br />EXTERIOR OF ROOM. <br />60OT150-43 CONT. METAL <br />TRACK W/ 1 /4" HILTI PINS <br />AT 8" O.C. INTO CONC. (1) <br />#8 SCREW EACH SIDE <br />EACH STUD. <br />** MAKE NEW ROOM AS <br />WIDE AS POSSIBLE. <br />WALL MUST CLEAR - <br />EXISTING ELECTRICAL <br />DISCONNECTS MOUNTED <br />ON WALL FOR EXISTING <br />ENLARGED PLAN <br />Scale: 1 /8"=1'-0" <br />PROVIDE PAIR 3'-0" x 7'-0" INSULATED <br />HOLLOW METAL DOORS AND FRAME WITH <br />TEMPERED GLASS VIEW PANELS. PROVIDE <br />LEVER LOCKSET AND CLOSER ON ACTIVE <br />LEAF, FLUSH BOLT ON INACTIVE LEAF <br />(LEFT DOOR). PAINT DOORS TO MATCH <br />EXISTING DOORS. <br />RE-ROUTE EXISTING HORIZONTAL AIR LINE <br />ABOVE PROPOSED ROOM TO CLEAR NEW <br />ROOM LID. _ ... _. <br />i <br />PROVIDE 4'-0 x 4'-0" -WINDOW WITH 1 <br />INSULATED TEMPERED GLASS IN HOLLOW <br />METAL FRAME. PAINT FRAME TO MATCH <br />EXISTING DOORS. - <br />- <br />POSITION NEW WALL 6" FROM EXISTING <br />MEZZANINE STRUCTURE. <br />AT VIBE ROOM <br />107 <br />CONFERENC <br />106 <br />N <br />Co <br />, <br />0-� <br />s <br />V) <br />z <br />0 <br />U <br />J <br />a <br />F_- <br />C <br />0 <br />n <br />a <br />0 <br />6 <br />a C <br />U <br />im <br />O C <br />3 <br />� <br />N <br />o0 <br />N 4% <br />N .0 <br />_ -0 <br />Uin <br />d �p <br />15 <br />U �o <br />i--- w Z <br />v_D D _ <br />U 3 <br />W O <br />IT Z <br />gin <br />04 <br />N <br />0 <br />0 <br />1 <br />n <br />4� <br />� <br />V <br />Q U <br />oo(j)L <br />�n <br />EQU� <br />> <br />o <br />Q — Q <br />E ca <br />ca o a) <br />���CoW <br />L QLn <br />Eq w N <br />Ln <br />QN <br />Q �D <br />U ❑ <br />N <br />0 • <br />(jj N <br />Lo <br />N <br />u <br />r( <br />UJ Co <br />Qrn <br />� <br />W <br />� a <br />W WLd <br />❑ <br />un <br />W N <br />u.l W <br />H <br />I <br />W o <br />—j <br />U r W <br />< <br />Z Q <br />Q ❑ <br />Ld <br />Q <br />sheet <br />Z <br />TA290 <br />J <br />
The URL can be used to link to this page
Your browser does not support the video tag.