1.0 GENERAL REWREMENTS <br />SCOPE: REFER TO SPECIFICATIONS FOR PROJECT SPECIFIC INFORMATION, <br />REQUIREMENTS AND APPROVED MATERIALS <br />A LIVE LOADS: ROSK CATEGORY: <br />RISK CATEGORY IV <br />MIND: <br />BASIC WIND SPEED: Vult=115 MPH <br />BASIC WIND SPEED WITH ICE: 30 MPH WITH 0.25" ICE <br />EXPOSURE C <br />Kzt: = 1.0 NO WIND SPEED—UP EFFECT' <br />SEISMIC: <br />DESIGN CATEGORY "D", SITE CLASS D, SS= 1,31 S1= 0.50 <br />B LEGAL DESCRIPTION: SEE SHEET T-1 FOR ABBREVIATED LEGAL DESCRIPTION. <br />C DRAWINGS: THE DRAWINGS ARE INTENDED TO PARTIALLY DESCRIBE THE OVERALL SCOPE OF WORK. <br />CONTRACTORS SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE PROJECT MANAGER 1N <br />ADVANCE ABOUT ANY UNFORESEEN CIRCUMSTANCES NOT DESCRIBED IN THE DRAWINGS BEFORE <br />BEGINNING WORK OR WORKING ON THE AFFECTED PORTION OF THE WORK. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL EXISTING UTILITIES. EXISTING <br />UTILITIES SHOWN HAVE BEEN OBTAINED FROM AVAILABLE RECORDS AND ARE SHOWN FOR <br />CONVENIENCE ONLY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADDITIONAL UTILITY LOCATIONS <br />NOT SHOWN. CARE SHOULD BE TAKEN TO AVOID DAMAGE OR DISTURBANCE TO EXISTING UTILITIES. <br />D ABBREVIATIONS: THROUGHOUT THE PLANS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE <br />PROJECT MANAGER WILL DEFINE THE CONTENT OF ANY IN QUESTION. <br />E REPETITIVE: TYPICAL WALL SECTIONS, FINISHES AND DETAILS ARE NOT INDICATED EVERYWHERE THEY <br />OCCUR ON PLANS, ELEVATIONS AND SECTIONS; REFER TO DETAILED DRAWINGS, CONTRACTOR TO <br />PROVIDE COMPLETE PROJECT AS IF DRAWN IN FULL. <br />F CODES/PERMITS/REGULATIONS: WORK NOT PART OF THE WORK OF THE PERMIT AND TO BE <br />PERFORMED UNDER SEPARATE PERMITS INCLUDES BUT IS NOT LIMITED TO MECHANICAL/ELECTRICAL <br />WORK <br />THE OWNER SHALL OBTAIN AND PAY FOR ALL PERMITS AND FEES UNLESS OTHERWISE NOTED IN THE <br />CONTRACT DOCUMENTS. <br />NOTHING IN THE DRAWINGS AND/OR SPECIFICATIONS SHALL BE CONSTRUED TO PERMIT AN <br />INSTALLATION IN VIOLATION OF APPLICABLE CODES AND/OR RESTRICTIONS. SHOULD ANY CHANGE IN <br />THE DRAWINGS BE NECESSARY IN ORDER TO COMPLY WITH APPLICABLE CODES AND/OR <br />REQUIREMENTS, THE CONTRACTOR SHALL NOTIFY THE PROJECT MANAGER AT ONCE AND CEASE WORK <br />ON ALL PARTS OF THE CONTRACT WHICH ARE AFFECTED. <br />THE WORK TO BE PERFORMED UNDER THIS CONTRACT SHALL BE IN FULL ACCORDANCE WITH THE <br />LATEST RULES, REGULATIONS, RESTRICTIONS, REQUIREMENTS, AND CODES. <br />ALL WORK AS SHOWN ON THE CONSTRUCTION DOCUMENTS IS JURISDICTION BUILDING CODE AND FIRE <br />CODE AS ADOPTED WITH CERTAIN AMENDMENTS IN THE BUILDING CODE. IT IS THE INTENT OF THESE <br />DOCUMENTS TO COMPLY THERETO. WORK PERFORMED IN VIOLATION OF THE LOCAL CODES, OR <br />ORDINANCES SHALL BE CORRECTED AT NO EXPENSE TO THE OWNER. <br />G CONFLICT: IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR STANDARDS OF INSTALLATION OR THE <br />MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, <br />THE LAWS OR ORDINANCES SHALL GOVERN THE INSTALLATION NOTIFY THE PROJECT MANAGER OF ALL <br />CONFLICTS. ANY WORK DONE BY THE CONTRACTOR AFTER DISCOVERY OF SUCH DISCREPANCY SHALL BE <br />DONE AT THE CONTRACTOR®S RISK. <br />H DIMENSIONS: SURVEY: DIMENSIONS OF SITE CONDITIONS ARE FROM SURVEY BY OTHERS. PROJECT <br />MANAGER BEARS NO RESPONSIBILITY FOR THEIR ACCURACY. DIMENSIONS ARE SHOWN TO FACE OF <br />CONCRETE, TO FACE OF CLADDING AT EXTERIOR FRAMED WALLS, FACE OF FINISH AT INTERIOR WALLS, <br />AND CENTERLINE OF OPENINGS, UNLESS DETAILED OTHERWISE ON DRAWINGS. CONTRACTOR SHOULD <br />REVIEW AND VERIFY ACTUAL CONDITIONS BEFORE FRAMING BEGINS AND NOTIFY THE PROJECT MANAGER <br />OF ALL CONFLICTS, <br />DO NOT SCALE DRAWINGS. THE CONTRACTOR SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND <br />ACTUAL FIELD MEASUREMENT. NOTIFY THE PROJECT MANAGER IF ANY DISCREPANCIES ARE FOUND. <br />CONTRACTORS SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR WORK. <br />THE CONTRACTOR SHALL VERIFY ALL ROUGH —IN DIMENSIONS FOR THE EQUIPMENT FURNISHED AND <br />INSTALLED BY CONTRACTOR OR OTHERS. <br />THE CONTRACTOR SHALL CONSULT THE PLANS OF ALL TRADES FOR OPENINGS THROUGH SLABS, <br />WALLS, CEILINGS AND ROOFS FOR DUCTS, PIPES, CONDUITS, CABINETS AND EQUIPMENT AND SHALL <br />VERIFY THE SIZES AND LOCATIONS WITH SUBCONTRACTORS. <br />I FIRE STOPS: FIRE STOPS IN WALL, OR CEILINGS, ETC. SHALL BE PROVIDED PER JURISDICTION BUILDING <br />CODE. SECTION 7 REQUIREMENTS. PROVIDE FIRE DAMPERS AT ALL SUPPLY AND RETURN AIR OUTLETS, <br />INLETS, OR DUCTS PENETRATING FIRE RATED ASSEMBLIES, ENCLOSURES, WALLS, FLOORS, OR SURFACES <br />AND AS REQUIRED BY FIRE DEPARTMENT. <br />J SHOP DRA NGS: PROVIDE SHOP DRAWINGS FOR THE PROJECT MANAGER/OWNER'S APPROVAL AND AS <br />REQUIRED BY GOVERNING JURISDICTION PRIOR TO CONSTRUCTION. <br />2.0 SITE WORK <br />A HAZARDOUS MATERIALS: DISCOVERY OF ANY HAZARDOUS MATERIALS (ASBESTOS, CHEMICAL WASTES, <br />PESTICIDES, ETC.) SHALL BE REPORTED IMMEDIATELY TO THE OWNER. AFTER MUTUAL AGREEMENT <br />BETWEEN CONTRACTOR PARTIES AND SUBMITTAL OF A WRITTEN CHANGE ORDER CONTRACTOR IS <br />RESPONSIBLE FOR REMOVAL, DISPOSAL AND CERTIFICATION AS REQUIRED BY LAW. OWNER TO ADVISE <br />OF KNOWN EXISTENCE. <br />B PERMITS: CONTRACTOR TO MAKE NECESSARY ARRANGEMENTS OR SECURE- NECESSARY PERMITS WITH <br />THE GOVERNING AGENCY FOR SITE WORK OR TO BLOCK SIDEWALKS OR STREETS DUE TO <br />CONSTRUCTION. <br />C SAFETY: THE CONTRACTOR SHALL PROVIDE COMPLETE SAFETY PRECAUTIONS AND MEASURES OVER <br />THE ENTIRE SITE INCLUDING ADJACENT YARDS, PASSAGEWAYS AND AREAS WHERE PERSONS NOT <br />ASSOCIATED WITH THE CONSTRUCTION PROJECT MAY BE PRESENT <br />� � �. I � 1 �• i I `� <br />5.0 APPLICABLE <br />A TIA-222-G: STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES AND ANTENNAS <br />B IBC: INTERNATIONAL BUILDING CODE, 2015 EDITION. <br />C ASTM: STANDARDS FOR BUILDING CODES, LATEST EDITION. <br />D ACI 301: AMERICAN CONCRETE INSTITUTE, SPECIFICATIONS FOR STRUCTURAL <br />CONCRETE, LATEST EDITION. <br />E ACI 318: AMERICAN CONCRETE INSTITUTE, BUILDING CODE REQUIREMENTS <br />FOR STRUCTURAL CONCRETE, 2014. <br />F ACI 315: AMERICAN CONCRETE INSTITUTE, DETAILS AND DETAILING OF CONCRETE <br />REINFORCEMENT, LATEST EDITION. <br />G ACI 530.1: AMERICAN CONCRETE INSTITUTE, SPECIFICATION FOR MASONRY CONSTRUCTION, 2013 <br />H CRSI: CONCRETE REINFORCING STEEL INSTITUTE, MANUAL OF STANDARD PRACTICE, LATEST EDITION <br />I AWS: AMERICAN WELDING SOCIETY, STRUCTURAL MELDING CODE, LATEST EDITION. <br />J AISC 303: AMERICAN INSTITUTE OF STEEL CONSTRUCTION, CODE OF STANDARD PRACTICE <br />FOR STEEL BUILDINGS AND BRIDGES, LATEST EDITION <br />K AISC 360: AMERICAN INSTITUTE OF STEEL CONSTRUCTION, SPECIFICATION FOR STEEL <br />BUILDINGS, 2010 <br />L NDS: NATIONAL DESIGN SPECIFICATION FOR MOOD CONSTRUCTION, AMERICAN MOOD <br />COUNCIL (AMC) 2015 <br />M ASCE 7-10: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES <br />SPECIAL6.0 INSPECTION <br />A A QUALIFIED INDEPENDENT TESTING LABORATORY, EMPLOYED BY THE OWNER, SHALL <br />PERFORM PERIODIC INSPECTION AND TESTING IN ACCORDANCE WITH IBC 2015 CHAPTER 17 <br />(SECTION 1705) FOR THE FOLLOWING CONSTRUCTION WORK: <br />B * STRUCTURAL CAST —IN —PLACE CONCRETE AND STEEL REINFORCING. <br />* PLACEMENT OF CONCRETE AROUND BOLTS AND EMBEDDED ITEMS. <br />* INSTALLATION OF POST INSTALLED BOLTS AND REBAR. <br />* STRUCTURAL HIGH STRENGTH BOLTED CONNECTIONS — ANSI/AISC 360-10 TABLES N5.6-1, 2 & 3 <br />* FIELD AND FULL PENETRATION STRUCTURAL WELDING — ANSI/AISC 360-10 TABLES N5.4-1, 2 & 3 <br />* STRUCTURAL MASONRY — TMS 402, ACI 530, ASCE 5, TMS 602 ACI 530.1 AND ASCE 6 <br />* SPECIAL GRADING, EXCAVATION, AND STRUCTURAL FILL. <br />* PILING, DRILLED PIERS, AND CAISSONS. <br />* STEEL REINFORCING IN CONCRETE. <br />* MISCELLANEOUS SPECIAL CASES, INVOLVING CONSTRUCTION UNDER HAZARDOUS OR <br />UNUSUAL CONDITIONS. <br />C REPORTS SHALL SUBMITTED IN ACCORDANCE WITH INTERNATIONAL BUILDING CODE, 2015 <br />CHAPTER 17. <br />D GENERAL CONTRACTOR TO SCHEDULE ALL "SPECIAL INSPECTIONS" WITH SAID TESTING <br />AGENCY BASED ON WORK PROGRESS. CONTRACTOR TO NOTIFY OWNER AND PROJECT <br />MANAGER 46 HOURS IN ADVANCE OF SCHEDULED TEST PROCEDURE <br />E THE INSPECTION AGENCY SHALL SUBMIT INSPECTION AND TEST REPORTS TO THE BUILDING <br />DEPARTMENT, THE ENGINEER OF RECORD, AND THE OWNER IN ACCORDANCE WITH IBC <br />2015 CHAPTER 17. <br />RCA <br />TELECOM <br />233 SOUTH SMACKER DRIVE <br />SUITE 4300 <br />CHI CACO, IL 60606 <br />31 2.244.3300 <br />-3cfi -2 v <br />NZ,, lix- �� ��- <br />,4%13 <br />w{ <br />BUILDING PERMIT REVIEW <br />1BUILDING PERMIT SET <br />,3201 SMITH AVENUE <br />98201 <br />.RO <br />"I--,-.�-1111,��.�.����.-I'l�'..,-"�",-",-.,-""�--��,.���-�-,�--"--,--,�-"�'..', mi. <br />I <br />