Laserfiche WebLink
ELEVATION NOTES <br />1, PROVIDE CONTINUOUS METAL GUTTERS <br />TYPICAL, <br />2, PROVIDE ROOF VENTS PER S,R.C, <br />SECTION R806 TYPICAL, <br />3, PROVIDE GALVANIZED SHEET METAL <br />4, PROVIDE WEATHERSTRIPPING AT ALL <br />DOORS AND WINDOWS, CAULK ALL <br />JOINTS AND PENETRATIONS IN EXTERIOR <br />WALL, <br />WEST ELEVATION <br />EX. MAIN LIVING SPACE <br />NO CHANGE <br />NEW STAIRWELL AND <br />36" GUARDRAILS/------ EX. MAIN LIVING SPACE <br />HANDRAILS NO CHANGE <br />X I EX. CEILING/FLOOR ASSEMBLY <br />NO CHANGE <br />R-15, TYP.— <br />FURRED WALLS <br />TYPICAL NEW INTERIOR WALL <br />MIN. 1/2" AIR GAP ENTRY LANDING--� —2x4 (or 2X6) STUDS @ 16" O.C. <br />TYP._ LEVEL 1 GWB EA. SIDE <br />PT PLATE F7 <br />TYP._ <br />(X) - <br />3 #4 CONT. 1 EXISTING SLAB AND FOUNDATIONS - <br />WITH R-10 INSULATION ON TOP BETWEEN -EX. SLAB ON GRADE PT 2X2 @ 24 O.C. <br />� NEW FOUNDATION PER PLANS <br />/-04@12" O.C: <br />SECTION AA'. <br />SCALE: 1 /4"= 1 '— 0 " <br />Window and door headers shaill be <br />insulated wIth a minlImum of R-10 <br />Insullation. <br />A minimum of 90 percent of <br />permanentlly InstaIled <br />lamps In lighting fixtures shaIll be <br />high -efficacy lamps. <br />CODE: 2018 IRC, <br />ENERGY <br />— PRESCRIPTIVE, OPTION IV <br />3 credits <br />— <br />OPTION <br />1.2 (WINDOWS U-0,20 —1CR.) <br />OP, 7.1 <br />(EFFICIENCY APPLIANCES-0.5CR.) <br />OP. 2.1 <br />(All whole house ventilation shall <br />be met <br />with a high efficiency fan(s) <br />(maximum <br />0.35 watts/cfm) 0.5 CR. <br />OP. 5.3 <br />(Water heating system shall <br />include <br />one of the following: <br />Energy <br />Star rated gas or propane water <br />heater <br />with a minimum UEF of 0.91 <br />HEATING IS ELECTRICAL — <br />FURNACE — EXISTING <br />N) <br />(HOUSE FRONT ELEVATIO <br />,'N40 CHANGE <br />DECK ABOVE AT MAIN FLOOR LEVEL <br />o BB <br />A3 <br />2,3'— 9 <br />1 11 L_ V v L__ I-) \11 r_X I L_ v v 11 14 L., \Ij v v —) U — Ij . Z_ U k_j I \ L.) L_ I I L-1 \I I II . <br />SOUTH ELEVATION (HOUSE SIDE ELEVATION) <br />1/4" = !9-0" <br />15'-9" 8'_0" <br />FULL HEIGHT GONCRETE WALL <br />X <br />MOP E;m I <br />._NEW WATER HEATER — SEE ENERGY <br />W. H--- REQUREVENTS OPTION 5.3 <br />CD <br />(a <br />X UTILITY <br />EX. 4X6 MIDDLE <br />IF CONFLICT RAISE HEAER HT;-----n_- BE-_�ROOM 1 <br />__j <br />P HARDWOOD <br />>l <br />110 ED <br />NEW WALL, TYP. <br />Z C) <br />Q0 <br />01 <br />0 <br />EX. 4-X6 MIDDLE <br /><------- ..... I," <br />> <br />FIRST & SECOND FLOOR FRAMING NOTES <br />1, WRITTEN DIMENSIONS TAKE PRECEDENCE <br />OVER SCALED DIMENSIONS <br />2, ALL HEADERS TO BE 6X8 AND 4X8 D.F. #2 <br />UNLESS OTHERWISE NOTED, CHECK PLAN, <br />3, BOTTOM OF HEADERS TO BE 6'-8' MIN, uno. <br />THIS FLOOR UNLESS OTHERWISE NOTED, <br />4, ALL EXTERIOR WALLS 2X6 WITH <br />R-21 INSULATION UNLESS NOTED OTHERWISE. <br />5, ALL FRAME NAILING TO SATISFY <br />CHAPTER 5, 6 2018 IRE, BLOCK ALL <br />PLYWOOD EDGES AND NAIL WITH IOD AT <br />6' O,C, TYPICAL ALL EXT, WALLS, <br />6, PROVIDE DOUBLE JOISTS OR BLOCKING <br />WHERE PARTITIONS OCCUR ABOVE, <br />7, PROVIDE SOLID BLOCKING OVER <br />SUPPORTS, <br />PLATE HEIGHT IS EXISTING UNLESS <br />8, OTHERWISE NOTED. <br />9, 0 DENOTES SOLID BEARING UNDER <br />CONCENTRATED LOADS USE (2) 2X6 AT <br />6' WALLS, USE (2) 2X4 AT 4' WALLS <br />UNLESS OTHERWISE NOTED, <br />10, FINISH ALL CEILINGS <br />WITH 1/2' G.W.B. <br />11. PROVIDE 26-GAUGE GALVANIZED SHEET <br />METAL FLASHING ABOVE WINDOWS AND <br />DOORS, (TYP.) LAP BUILDING PAPER <br />OVER <br />12. HOLD SIDING 6' ABOVE FINISH GRADE, <br />TYPICAL. <br />13, WINDOWS SPECIFIED ARE MFGR, BY: <br />MILGARD, OR EQUAL. U=0,28 OR BETTER <br />CONTRACTOR TO VERIFY ALL ROUGH <br />OPENINGS. <br />14, FASTEN MULTI -LAM 2X BEAMS PER <br />TABLE R602.3(1) 1,R,C,, TYPICAL <br />15, UPPER FLOOR FRAMING TO BE <br />PER PLANS TYPICAL U,N,O, <br />16, CEILING JOISTS TO BE 2X6 AT 24' <br />0,C,, TYPICAL U,N.D,, PLAN SHOWS JOIST <br />DIRECTION, <br />IT ALL VOIDS TO BE FIRE/DRAFT BLOCKED <br />PER I.R,C, R602,8 & R302.11 <br />01 <br />M <br />< <br />(0 BEDROOM 2o @ <br />HARDWOOD 110 SD <br />EX, 4X6 MIDDLE <br />EX. FLOOR - ALL -SLAB ON GRADE <br />cc 3: <br />POST ON FOUNDATION UNDER 1 0 <br />COLUMN ABOVE r- _j <br />X <br />"' <br />NEW 6X4 POSTX <br />EX. 4X6 MIDDLE <br />b <br />NEN 2X4@16"OC WA�LJYP. <br />WIC <br />NEW POSTS <br />EX. 6X6 MIDDLE <br />FT, AA <br />L __ — —1 <br />00 <br />Lo <br />co <br />CN <br />IIIIIIIIIAX10 ro : I <br />0 <br />I TS D 2668 <br />10 ri--- <br />�IM <br />AT ROOM <br />I <br />FAN V.T.O. <br />75 CFM <br />MIN. <br />SHOWER/ <br />TUB <br />Uj <br />EX. 4X6 MIDDLE <br />0 <br />0- 1 W <br />00 <br />UC IL11TYF <br />EXISTING W.H. <br />7'— <br />�Bp <br />E] El A3 1:1 F — — -EL— <br />I El El 0 I <br />--------------- — — — — — — -- — <br />DECK ABOVE AT MAIN FLOOR LEVEL <br />- INTERMITTED WHOLE HOUSE (24 <br />0 HR. TIMER TO CONTROL EXUAST <br />FAN) <br />1.5 SONE(QUIET) EXAUST FAN <br />SIZED (AT.25W.G.) 75 CFIVI, <br />50%(FACTOR 2) EXAUST ONLY <br />WITH DUCTED FORCED AIR <br />SYSTEM OR INTEGRATED WITH A <br />FORCED -AIR SYSTEM PER <br />M1 505.4.1.2 <br />(maximum 0.35 watts/cfm), <br />BATHROOM FAN EXAUST <br />TO OTSIDE (ROOF), VENT <br />NOT TO EXEED 25 FEET <br />1111 SD <br />EXISING <br />c') AA <br />— INDICATES APPROVED CARBON <br />MONOXIDE ALARM <br />@ — INDICATES APPROVED SMOKE <br />110 SDDETECTOR/ALARN <br />L <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />F0oQf~ 00 <br />z -z <br />0 <br />o 0 <br />0 <br />.20 <br />O <br />O <br />7137 <br />HNISI RRED <br />1 t <br />R HI-FECT <br />-0, <br />ART'I;_j V <br />STAT -11 ON <br />!L- <br />Date 5/26/2021 <br />PLAN <br />ELEVATIONS <br />SECTION <br />