My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7423 2ND DR SE 2020 Plans 2022-11-02
>
Address Records
>
2ND DR SE
>
7423
>
Plans
>
7423 2ND DR SE 2020 Plans 2022-11-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/2/2022 8:03:20 AM
Creation date
7/21/2022 8:32:39 AM
Metadata
Fields
Template:
Address Document
Street Name
2ND DR SE
Street Number
7423
Permit
B2007-039
Year
2020
Notes
REPAIR DAMAGE TO ROOF STRUCTURE CASED BY FIRE IN ATTIC
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MAIN FLOOR WALL <br />I � � <br />cn <br />m U) a <br />c w� <br />0 00W <br />w ^X E <br />w N> <br />_.., — D <br />< L, 1 -1 <br />0 <br />LL <br />w <br />A <br />AS BUILT AND REPAIR MAIM LEVEL ROOF PLAN WITH DAMAGED ELEMENTS <br />SCALE: 1/49, = 1 0—®,> <br />AS BUILT CONDITIONS ARE <br />ASSUMED, IF ACTUAL <br />CONDITIONS ARE DIFFERENT, <br />CONTACT ENGINEER <br />IF DURING THE REPAIR WORK ANY DAMAGED <br />ELEMENTS ARE UNCOVERED THAT ARE NOT <br />SPECIFIED IN THE PLAN, THEY SHOULD BE <br />REPLACED WITH IDENTICAL DIMENSIONS AND <br />MATERIALS. OTHERWISE, CONTACT THE ENGINEER. <br />THE TRNKA ENGINEERS CO. DESIGN THE <br />STRUCTURAL REPAIR PLANS USING THE EXISTING <br />SIZES, SPECIES AND TYPES OF STRUCTURAL <br />ELEMENTS. <br />WE PROVIDE SOME RETROFITS AND UPGRADES <br />BASED ON OUR ENGINEERING JUDGMENT OR PER <br />BUILDER REQUEST. <br />WE ARE NOT RESPONSIBLE FOR THE EXISTING <br />BUILDING DESIGN AND CONSTRUCTION ERRORS. <br />NOTE: <br />ROOF, WALLS & FLOOR INSULATION <br />ARE TO COMPLY WITH 2O15 WA <br />STATE RESIDENTIAL ENERGY CODE. <br />NOTE: <br />ALL FIRE REQUIREMENT SUCH AS: SMOKE & <br />CARBON MONOXIDE ALARMS, DRAFT STOPS <br />ARE TO COMPLY WITH 2O15 IRC CODE. <br />ROOF VENT CALCULATION <br />— BASED ON (3)-2" 0 HOLES BIRD SCREEN BLOCKING <br />OVER THE TOP PLATE (3x3.14x2x2/4=9.42si). <br />— ROOF AREA WITH ATTIC 971 sf. <br />— VENTING REQUIRED 971 sfx144-/150=932si. <br />— PROVIDE INTAKE 26 VENTED BLOCKING, W/9.42si <br />HOLES 26x9.42si=245si. <br />— PROVIDE FOR BALANCE OF 932si-245si=687si THE <br />(4)-7"x7" ATTIC ROOF JACKS W/VENT AREA <br />4x7"x7"XO.75=147si. AND FOUR 18"02" EXISTING <br />LOUVERED WINDOWS W/VENT AREA <br />408%12"x0.65=562si. TOTAL VENT AREA <br />147si+562si=709si> 687si. <br />FOUR 7"x7" ROOF JACKS REQUIRED <br />REPLACE EXISTING ROOF <br />TRUSSES, SHEATHING <br />AND ROOFING <br />— COMPOSITION SHINGLES <br />ROOFING OVER UNDERLAYMENT <br />— 1 /2" PLYWOOD or OSB SHEATHING <br />— MFG. TRUSSES @ 24"o.c. <br />— INSULATION R-49 <br />— 1 /2" GWB <br />AIR BAFFLE, 1 <br />AIR FLOW MIN. <br />VENT BLOCKING W/(3)-2"0_ <br />HOLES @ ALL TRUSSES <br />S WALL TOP PLATE <br />— 1 /2" GWB <br />2x4 @ 16"o.c. STUDS <br />_ W/R-15 INSULATION TYP. <br />— 15# FELT VAPOR BARRIER <br />— T1-1 1 SIDING, <br />MATCH TO EXISTING <br />i <br />i� <br />EXTERIOR WALLS <br />----_ -_ INTERIOR WALLS <br />t <br />2 ENGINEERING DETAILS 8e SECTIONS <br />S1.2 <br />ENGINEERING NOTES <br />-- — <br />— <br />BEAM <br />OR <br />HEADER <br />BELOW, SIZE PER PLAN <br />Ivi <br />POST, <br />D8L <br />STUDS <br />DOWN BELOW <br />EX. FOUNDATION <br />32 <br />6 1 <br />OFFICE <br />"± �EX. FURRING WALL <br />RIDGE VENT <br />NEW 2x6 @ 24"o.c. <br />OVERFRAMING <br />BATH II WIC <br />SECTION "A -A" <br />SCALE: 1 /4?9 = V—O" <br />EXISTING <br />GIRDER TRUSS <br />EXISTING TRUSS <br />TO REMAIN <br />DRIVEWAY APPROACH <br />ON JULY 1, 2020, 1 INSPECTED THE ONE STORY WITH BASEMENT AND TWO <br />CAR GARAGE BUILDING ON THE RESIDENTIAL PROPERTY OF MANUEL <br />MARTINEZ, LOCATED AT 7423 2nd DR. S.E., EVERETT, WA 98203. THE <br />PURPOSE OF THE VISIT WAS TO ASSESS STRUCTURAL DAMAGE CAUSED BY <br />THE FIRE AND TO PROVIDE ASSISTANCE IN DEVELOPING THE REPAIR PLAN. <br />THE OBSERVED DAMAGES INCLUDE: <br />15 OF THE 18 MANUFACTURED TRUSSES HAVE UNREPAIRABLE <br />FIRE DAMAGE, THEREFORE ALI, -TRUSSES NEED TO BE REPLACED <br />ALONG WITH THE ROOF SHEATHING, OVERFRAMING AND GABLE ENDS. <br />THE 2x4 WALL TOP PLATE IS BURNT AND NEEDS TO BE <br />REPLACED, SEE DET. "2/S1.2". <br />3 THE DAMAGED 2x4 STUD NEEDS TO BE REPLACED. <br />4 THE LEFT & RIGHT GABLE END TRUSSES HAVE BURNT WEB <br />ELEMENTS AND NEED TO BE REPLACED ALONG WITH THE <br />HORIZONTAL BEVELED SIDING AND 12"x18" LOUVERED WINDOWS, <br />NEW PLYWOOD SHEATHING NEEDS TO BE ADDED BELOW THE <br />BEVELED SIDING FOR LATERAL LOAD TRANSFER, NAILING PER <br />P1-6 OF THE SHEAR WALL SCHEDULE . <br />5 THE EXISTING T1 —1 1 SIDING ON THE MAIN FLOOR LEVEL AT THE <br />REAR SIDE IS DAMAGED AND NEEDS TO BE REPLACED TO MATCH <br />EXISTING, NAILING PER T1-6 OF THE SHEAR WALL SCHEDULE. <br />PROVIDE BLOCKING AT THE HORIZONTAL SIDING JOINTS. <br />SEE RECOMMENDATIONS AND DETAILS ON PROPOSED ROOF PLAN <br />HOW TO REPAIR THE DAMAGES. <br />�a <br />� I m co co <br />H <br />Lu v-_. "'t <br />LLf 7tI- <br />_ <br />I"— La 'i � <br />LU LU CN 1t <br />x <br />EL <br />�CL00C.LL <br />Lu <br />LLJLu <br />N <br />C <br />W <br />_ <br />Lu <br />1 FQ� <br />X <br />w <br />Lu <br />Lu <br />Lu <br />Lu <br />w <br />Lu <br />LLI <br />Lu <br />z <br />0 <br />Lu <br />LU <br />CL <br />aZ <br />LU <br />L <br />t: <br />Lu <br />C) <br />Lu <br />e <br />CL <br />ujLu <br />r <br />o� <br />Lu <br />0 <br />z <br />z <br />m <br />o=EL <br />�- <br />0 <br />Lu <br />Lu <br />a-- <br />w <br />CL <br />µ <br />M <br />t <br />r <br />E <br />
The URL can be used to link to this page
Your browser does not support the video tag.