ARCHITECTURAL NOTES <br />GENERAL <br />1. ALL WORK SHALL CONFORM TO THE 2015 INTERNATIONAL RESIDENTIAL <br />CODE, THE 20 15 INTERNATIONAL BUILDING CODE, THE WA511INGTON <br />STAI E BUILDING CODE AND ALL APPLICABLE LOCAL JURISDICTION <br />RULES AND REGULATIONS, PROJECTS IN THE CITY OF 5EATTLE <br />SHALT_ CONFORM TO THE 2015 SEATTLE RESIDENTIAL CODE (SRC) <br />FOR ARCHITECTURAL � THE 20 15 SEATTLE BUILDING CODE (58C) <br />FOR STRUCTURAL, <br />2. CONTRACTOR TO VERIFY ALL DIMENSION DATUMS AND LEVELS PRIOR <br />TO CONSTRUCTION. ALL DIMEN51ON5 ARE TO FACE OF STUD OR <br />FACE OF CONCRETE UNLESS NOTED OTHERWISE. DO NOT SCALE <br />DRAWINGS FOR CRITICAL DIMENSIONS. <br />S. CONTRACTOR SHALL_ BE RESPONSIBLE FOR ALL REQUIRED SAFETY <br />PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR <br />PROCEDURES REQUIRED TO PERFORM THE WORK. <br />4. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN WITHOUT <br />WRITTEN INSTRUCTIONS FROM THE ARCHITECT. <br />5. REPORT ERRORS AND OMISSIONS TO THE ARCHITECT IMMEDIATELY, <br />G. THESE DRAWINGS ARE THE PROPERTY OF JGAT+STUDIO LLC <br />AND MAY BE REPRODUCED ONLY WITH WRITTEN PERMISSION. <br />AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME AND SIGNATURE <br />OF THE ARCHITECT. <br />7. WORKING DRAWINGS BY THEIR VERY NATURE ARE DIAGRAMMATIC AND <br />DO NOT PROVIDE ALL DETAILS OR CONDITIONS OF CONSTRUCTION, <br />HOWEVER, QUESTIONS MAY ARISE AS TO THE DESIGN INTENT AND <br />TO CONSTRUCTION TECHNICAL DETAILING WITHIN THESE DRAWINGS. <br />AS CLARIFICATIONS, INTERPRETATIONS, AND REVISIONS ARE PART OF <br />THE CONSTRUCTION PROCESS, JGAT+STUDIO LLC. <br />SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT OR <br />CONSEQUENTIAL DAMAGES AS A RESULT OF NOT PARTICIPATING IN <br />THE CONSTRUCTION PROCESS. <br />MISCELLANEOUS ASSEMBLY REQUIREMENTS <br />ALL EXPOSED EXTERIOR METAL SHALL BE GALVANIZED, <br />2, ALL WOOD IN CONTACT WITH CONCRETE OR EARTH SHALL BE <br />PRESSURE TREATED PER IRC R3 19. ALL PRESSURE TREATED LUMBER <br />(PT.) SHALL NOT CONTAIN, OR BE TREATED WITH CHROMIUM COPPER <br />ARSENATE. <br />3. PROVIDE ATTIC ACCESS, MINIMUM 22" X 30% WITH 30" MINIMUM <br />HEADROOM AT UNOBSTRUCTED, READILY ACCESSIBLE OPENING PER <br />IRC R807. INSULATE AND WEATHER-STRIP. <br />4. PROVIDE CRAWL SPACE ACCESS, MINIMUM 1 8"X 24" UNOBSTRUCTED <br />OPENING PER IRC R408.3. ALLOW 1 8" MINIMUM SPACE UNDER WOOD <br />JOISTS AND 1 2" MINIMUM UNDER. WOOD GIRDERS. INSULATE AND <br />WEATHER-STRIP. <br />5. PROVIDE VENTILATION PER IRC AS FOLLOWS: <br />a. CRAWL SPACE VENTILATION: MINIMUM NET AREA SHALL NOT BE <br />LESS THAN I SF PER 150 5F OF UNDERFLOOR AREA. OPENINGS <br />SHALL BE PLACED WITHIN 3 FEET OF THE CORNERS AND SHALL <br />PROVIDE CROSS VENTILATION PER IRC R408. 1 AND R408.2 <br />b. ATTIC VENTILATION: MINIMUM NET AREA SHALT_ NOT BE LE55 THAN <br />15F PER 150 5F OF ATTIC AREA, OR 1 5F PER 300 SF OF ATTIC <br />AREA IF 50% IS IN THE SOFFIT AND 50% IS AT LEAST 3' ABOVE <br />h. COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 2" OF <br />THE FIREPLACE, SMOKE CHAMBER OF CHIMNEY WALL OR <br />WITHIN 1 2" OF FIREPLACE OPENING, NO COMBUSTIBLE <br />MATERIAL WITHIN 1 2" OF THE FIREPLACE OPENING SHALL <br />PROJECT MORE THEN 1 /8" FOR EACH I " OF CLEARANCE FROM <br />SUCH OPENING PER IKC R1003. 12. <br />9. EXTERIOR DOORS AND WINDOW ASSEMBLIES <br />a. ALL BUILDING ENTRANCE DOORS INCLUDING GARAGE DOORS <br />SHALL BE EQUIPPED WITH LOCKS CONSISTING OF A DEAD <br />LOCKING LATCH BOLT WITH AT LEAST 1/2" OF THROW WHICH <br />PENETRATES THE STRIKE JAMB A MINIMUM OF 1/4". BUILDING <br />ENTRANCE DOORS SHALL BE OPENABLE FROM THE INSIDE <br />WITHOUT A KEY OR SPECIAL KNOWLEDGE OR EFFORT . <br />b. BUILDING ENTRANCE DOORS SHALL BE EQUIPPED WITH AN <br />OBSERVATION PORT OR WINDOW SIDELIGHT, OBSERVATION <br />PORTS SHALL BE INSTALLED AT MINIMUM 54" TO MAXIMUM GG" <br />ABOVE THE FLOOR. <br />c. ALL OPERABLE WINDOWS AND SLIDING GLASS DOORS <br />INSTALLED WITHIN 1 0'-0" OF FINISH GRADE SHALL BE <br />EQUIPPED WITH A LOCKING DEVICE. THIS LOCK SHALL BE <br />INSTALLED SO ITS MOUNTING HARDWARE IS INACCESSIBLE - <br />FROM THE EXTERIOR. <br />10. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED <br />DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM <br />AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP <br />STORY AND THE ROOF SPACE. FIKEBLOCKING SHALL BE PROVIDED <br />IN WOOD FRAME CONSTRUCTION PER IRC RG02.8. <br />1 1. FIBER CEMENT LAP SIDING SHALL BE LAPPED A MINIMUM OF 1 -1 /4" <br />AND SHALL HAVE ENDS SEALED WITH CALKING, COVERED WITH AN HSECTION <br />JOINT COVED, OR LOCATED OVER A STRIP OF FLASHING, <br />FIBER CEMENT PANEL SIDING SHALL BE INSTALLED WITH THE LONG <br />DIMENSION PARALLEL TO THE FRAMING, VERTICAL JOINTS SHALL <br />OCCUR OVER FRAMING MEMBERS AND SHALL BE SEALED WITH <br />CAULKING OR COVERED WITH BATTENS. HORIZONTAL JOINTS SHALL <br />BE FLASHED WITH Z-FLASHING AND SOLID BLOCKED. ALL FIBER <br />CEMENT SIDING INSTALLATION SHALL CONFORM TO <br />MANUFACTURERS INSTRUCTIONS AND IRC R703. 10, <br />12, APPROVED CORRISION-RESISTIVE FLASHING SHALL BE PROVIDED IN <br />THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT THE <br />ENTRY OF WATER INTO THE WALL CAVITY, REPEATED WETTING OF <br />THE SHEATHING, OR PENETRATION OF WATER TO THE BUILDING <br />STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND <br />TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE <br />INSTALLED TO PREVENT WATER FROM RE-ENTERING THE EXTERIOR <br />WALL ENVELOPE. APPROVED CORROSION FLASHING SHALL BE <br />INSTALLED AT ALL OF THE FOLLOWING LOCATIONS; <br />a. AT THE TOP OF ALL EXTERIOR WINDOW AND DOOR OPENINGS IN <br />SUCH A MANNER AS TO BE LEAKPROOF. <br />b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY <br />CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH <br />PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS, <br />c, UNDER AND AT THE ENDS OF ALL MASONRY, WOOD OR METAL <br />COPINGS AND SILLS. <br />d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. <br />e. WHERE EXTERIOR PORCHES, DECKS, HALF -WALLS, RAILINGS OR <br />STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD <br />FRAME CONSTRUCTION. <br />f. AT WALL AND ROOF INTERSECTIONS <br />THE PLATE LINE PER IRC R80G, 1. g. AT BUILT IN GUTTERS, <br />13. UNDERLAYMENT FOR ROOF SLOPES FROM 2: 1 2 TO 4: 1 2 SHALL BE TWO <br />G. SLOPE ALL DECKS, WALKS, DRIVEWAYS AND PATIOS AWAY FROM THE LAYERS APPLIED IN THE FOLLOWING MANNER: APPLY A 1 9" STRIP OF <br />BUILDING AT A MINIMUM OF 1/4" PER FOOT. UNDERLAYMENT FELT PARALLEL WITH AND STARTING AT THE EAVES, <br />FASTENED SUP FICIENTLYTO HOLD IN PLACE, STARTING AT THE SAVE, <br />7. STAIR ASSEMBLY: APPLY 30" WIDE SHEETS OF UNDERLAYMENT, OVERLAPPING <br />5UCCE551VE 5HEE T S 1 9" AND FASTENED SUFFICIENTLY TO HOLD IT IN <br />a. HEADROOM 0-8" MINIMUM AND WIDTH 3'-0" MINIMUM PEP, IRC R3 1 1.5 PLACE, FOR ROOF SLOPES OF 4: 1 2 OR GREATER, UNDERLAYMENT <br />SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER: <br />b. THE MAXIMUM RISER HEIGHT SHALL BE 7-3/4", OPEN RISERS ARE UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO <br />PERMITTED PROVIDED THAT THE OPENING BETWEEN TREADS IS LESS AND STARTING FROM THE EAVE AND LAPPED 2 INCHES, FASTENED <br />THAN 4". THE MINIMUM TREAD DEPTH SHALL BE 10" PER IRC R3 1 1.5.3. SUFFICIENTLY TO HOLD IT IN PLACE. END LAPS SHALL BE OFFSET BY <br />G FEET, PER IRC R905.2.7, <br />c. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH <br />CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS. 14. ASPHALT SHINGLES SHALL HAVE SELF -SEAL STRIPS OR BE <br />HANDRAIL HEIGHT SHALL BE NOT LE55 THAN 34" AND NOT MORE INTERLOCKING AND COMPLY WITH ASTMD225 OR D34G2. <br />THAN 38". HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR <br />THE FULL LENGTH OF THE FLIGHT, FROM THE TOP TO THE BOTTOM RISER. <br />HANDRAILS SHALL RETURN PER IRC R3 1 1 .5.G.2. HANDRAILS ADJACENT <br />TO A WALL SHALL BE A SPACE OF NOT LESS THAN 1 -1 /2" FROM THE <br />WALL TO THE HANDRAIL PER IRC R3 I 1 .5.G. <br />d. INSTALL FIRE BLOCKING AT TOP AND BOTTOM OF STRINGER SPAN <br />AND WALL ALONG STRINGER RINGER PER IBC RG02.8. <br />e. COVER USABLE SPACE UNDER STAIR WITH 1 /2" GWB PER IRC <br />R3 1 1 .2.2 <br />f. OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR <br />ORNAMENTAL PATTERN SUCH THAT A SPHERE OF 4" OR MORE <br />IN DIAMETER CANNOT PASS THROUGH PER IBC R3 12.2. <br />a. DOORS TO THE EXTERIOR SHALL HAVE A MAXIMUM 7-3/4" STEP TO <br />A MINIMUM 30 DEEP LANDING, BUT THE DOOR MAY NOT <br />SWING OVER THE LANDING PEP IRC R3 1 1.43 <br />h. PORCHES, BALCONIES OR RAISED FLOOR SURFACES MORE THAN <br />30" ABOVE THE FLOOR OR GRADE SHALL HAVE GUARD RAILS <br />NOT LESS THAN 3G" IN HEIGHT PER IRC K3 12. 1. <br />8. FIRE PLACES AND SOLID FUEL BURNING APPLIANCES <br />a. SOLID FUEL BURNING APPLIANCES INCLUDING SITE BUILT <br />FIREPLACES, AIRTIGHT STOVES, FIREPLACE STOVES, FACTORY <br />BUILT FIREPLACES, AND FIREPLACE INSERTS AND SHALL_ <br />COMPLY WITH THE PROVISION OF THE IRC AND IBC. <br />b. METAL CHIMNEYS SHALL BE ENCLOSED ABOVE THE STORY IN <br />WHICH THE APPLIANCE SERVED IS LOCATED, IN WALLS HAVING <br />I -HOUR. FIRE RESISTANCE RATING, AND WITH A SPACE ON ALL <br />SIDES BETWEEN CHIMNEY AND THE ENCLOSING WALL <br />5UFFICIENT FOR EXAMINATION AND REPAIR FOR ENTIRE - <br />CHIMNEY. <br />c. PROVIDE FIRESTOPPING AT CHIMNEY PER IRC KI 001 . 1 G. <br />d. INSTALL FACTOR`( BUILT FIREPLACES WITH HEARTH AND <br />SURROUNDS PER MANUFACTURERS SPECIFICATIONS. <br />e. PREFABRICATED FIREPLACES, CHIMNEYS AND RELATED <br />COMPONENTS TO BEAR UL APPROVAL AND BE INSTALL PER <br />MANUFACTUKEK'5 REQUIREMENTS. <br />f. THE HEARTH SHALL EXTEND AT LEAST I G" IN FRONT OF AND 8" TO <br />EACH SIDE OF THE FIREPLACE OPENING WHEN THE OPENING IS <br />SMALLER THAN G SF. IF THE OPENING IS G 5F OR LARGER THE <br />HEARTH SHALL EXTEND 20" IN FRONT AND 1 2" TO EACH SIDE, <br />PER IRC R1003. 10. <br />15. CLAY AND CONCRETE TILE SHALL BE INSTALLED AS PER <br />MANUFACTURERS I1\15TALLAT ION INSTRUCTIONS AND IRC R905.3. <br />I G. METAL ROOF SHINGLES AND METAL ROOF PANELS SHALL BE INSTALLED <br />PER MANUFACTURERS INSTALATION INSTRUCTIONS AND IRC P905.4 <br />AND R905. 10. THE SLOPE OF METAL ROOFS SHALL BE A MINIMUM OF <br />3: 1 2. <br />STRUCTURAL NOTES <br />SEE AI-50 THE STRUCTURAL ENGINEER'S NOTES ON ATTACHED "S" <br />5HEET5, <br />THE FOLLOWING STRUCTURAL NOTES ARE SUPPLEMENTAL TO THE <br />ENGINEERING NOTES. IN ANY CASE OF CONFLICT, THE ENGINEERS <br />STRUCTURAL NOTES SHALL SUPERSEDE THESE NOTES. <br />1. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF <br />CONSTRUCTION, WHERE CONDITIONS ARE NOT SPECIFICALLY <br />INDICATED BUT ARE OF SIMILAR CHARACTER TO THE DETAILS SHOWN, <br />SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO <br />REVIEW AND APPROVAL BY'I HE ARCHITECT AND THE STRUCTURAL <br />ENGINEER, <br />2. FOUNDATION SUPPORTING WOOD SHALL EXTEND AT LEAST G" ABOVE <br />THE ADJACENT FIN15H GRADE. FOUNDATION WALL BACKFILL SHALL <br />BE PLACED SIMULTANEOUSLY ON BOTH SIDES OF WALL. PROVIDE 4" <br />PERFORATED PIPE FOR SUBSURFACE DRAINAGE, FOOTING SIZE <br />SHALL BE AS INDICATED ON DRAWINGS OR PER IRC K405, <br />S. FOUNDATIONS WHERE THE SURFACE 15 SLOPED MORE THAN ONE (1) <br />FOOT IN TEN (10) FEET SHALL BE LEVEL OR SHALL BE STEPPED 50 <br />THAT BOTH "TOP AND BOTTOM OF SUCH FOUNDATION ARE LEVEL_ PER <br />IBC R403. 1 ,5. <br />4. WHERE STRUCTURAL COLUMNS AND POSTS ARE EXPOSED TO <br />WEATHER OR WATER SPLASH ABOVE A CONCRETE SURFACE, <br />PROVIDE A MINIMUM I " FIER OR METAL PEDESTAL ABOVE THE <br />CONCRETE SURFACE PER IRC R3 1 9. 1 ,4, <br />5. FOUNDATION PLATES SHALL BE BOLTED TO THE FOUNDATION WITH <br />STEEL BOLTS EMBEDDED INTO THE CONCRETE. THERE SHALL BE A <br />MINIMUM OF TWO (2) BOLTS PER PIECE AND WITHIN 1 2" FROM EACH <br />END PER IRC R403. I.G. SEE DRAINING FOR 51ZE AND SPACING. <br />G. CONCRETE SLABS ON GRADE SHALL BE 4" THICK MINIMUM, A 4" THICK <br />GRAVEL BASE COURSE 511ALL BE PLACED ON THE PREPARED <br />SUBGRADE WHEN THE SLAB 15 BELOW GRADE PER IRC R50G,2.2 <br />7. A G MIL. POLYELETHENE VAPOR BARRIER WITH JOINTS LAPPED NOT <br />LE55 THAN G" 5HALL BE PLACED BETWEEN THE CONCRETE FLOOK <br />SLAB AND BASE COURSE PER IRC R50G.2.3, <br />8. NOTCHES IN SOLID LUMBER JOISTS, RAFTERS AND BEAMS SHALL NOT <br />EXCEED ONE SIXTH OF THE DEPTH OF THE MEMBER, SHALL NOT BE <br />LONGER THAN ONE THIRD OF THE DEPTH OF THE MEMBER AND SHALL <br />NOT BE LOCATED IN THE MIDDLE ONE THIRD OF THE SPAN. NOTCHES <br />AT THE ENDS SHALL NOT EXCEED ONE FOURTH OF THE DEPTH OF THE <br />DOOR AND WINDOW NOTES <br />MEMBER, THE TENSION SIDE OF MEMBERS 4" OR GREATER IN <br />NOMINAL THICKNESS SHALL NOT BE NOTCHED EXCEPT AT THE ENDS. <br />1. EVERY elFFPING ROOM AND HABITABLE ROOMS IN BASEMENTS SHALL <br />HAVE AT LEAST ONE OPERABLE WINDOW WITH A NET CLEAR <br />THE DIAMETER OF HOLES SHALL NOT EXCEED ONE THIRD OF THE <br />OPENING OF 5.7 SF. THE OPENING HEIGHT SHALL D, 24"MINIMUM <br />AND WIDTH 20" MINIMUM, WITH A FINISHED SILL HEIGHT 1\10 MORE THE <br />DEPTH NOR BE CLOSER THAN 2" TO THE TOP OR BOTTOM OF THE <br />44" ABOVE THEE FLOOR. PER IPC R310. 1 . IF WINDOW WELLS ARE <br />MEMBER, PER IRC K802,7. 1 <br />NECE55ARYTHEY SHALL MEET THE REQUIREMENTS OF IRC R310.2. <br />9. ANY STUD IN AN EXTERIOR WALL OR BEARING PARTITION MAY BE CUT <br />WINDOWS <br />RES�rT WINDn�OAA5S �cIFl� N TABLLE DESIGNED AND <br />E <br />OR NOTCHED TO A DEPTH NOT EXCEEDING 25% OF ITS WIDTH, PER <br />ADJUSTED FOP HEIGHT AND EXPOSURE PEP TABLE R301.2(.�). <br />IRC R G02. G. <br />3. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN <br />APPROVED INDEPENDENT LABORATORY AND BEAR A LABEL <br />10. STRUCTURAL FLOOR MEMBERS SHALL NOT BE CUT, BORED OR NOTCHED <br />IDENTLYING MANUFACTURER., PERFORMANCE CHARACTERISTICS <br />AND APPROVED INSPECTION AGENCY To INDICATE COMPLIANCE <br />IN EXCESS OF IRC K502.8 AND FIGURE R502.8, <br />WITH THE REQUIREMENTS OF IRC RG 13.3. <br />4. WINDOW AND GLASS DOOR ASSEMBLIES SHALL BE ANCHORED IN <br />1 1. CUTS, NOTCHES AND HOLES BORED IN LAMINATED VENEER LUMBER <br />ACCORDANCE WITH THE MINIMUM REQUIREMENTS I1 LU5T RATED IN <br />(LVL) GLU-LAMINATED LUMBER (GLU-LAM) OR I -JOISTS ARE <br />IRC RG13.5. <br />PERMITI ED ONLY IN LOCATIONS APPROVED BY THE MANUFACTURER <br />5. GLAZING IN HAZARDOUS LOCATIONS (AS OUTLINED IN IBC 240G.3) <br />SUCH As: <br />AND CONSIDERED IN THE SPECIFIC DESIGN OF THE MEMBER, PER IRC <br />a. PANESINSWINGING, , OPMoPBIFOLoDooPs: <br />R802.7.2. <br />b. GLAZING WITHIN 24" OfFAA ROOROPENING, <br />C. GLAZING IN STAIRWAYS, <br />d. GLAZING IN SHOWER OR TUB SURROUNDS <br />e. GLAZING IN GUARDS AND RAILINGS <br />12. PREFABRICATED WOO ROOF TRUSSES SHALL BE DESIGNED BY THE <br />f. GLAZING CL05EPTHAN 18" To A, FLOOR <br />MANUFACTURER IN ACCORDANCE WITH AN51/7I I FOR THE SPAN <br />SHALL BE SAFETY GLAZING OR WIRE REINFORCED, TEMPERED OR <br />CONDITIONS SHOWN ON THE PLAN�J. <br />LAMINATEDSAFETY GLASS, OR, 5HATTERRE515TANTPLASTIC PEP <br />IRC P308.4 AND IBC 240& GLAZING WITH THE EXPOSED EDGE <br />WITHIN A 24" ARCH OF THE VERTICAL EDGE OF A DOOR SHALL BE <br />STANDARD COMPOSITION ROOF LOADING SHALL BE <br />5AFETYGLA-ZINC-PEP[PC R308.4 <br />TOP CHORD LIVE LOAD 25 PSF <br />G. GLAZING IN SKYLIGHTS SHALL CONFORM TO IRC R308.G, <br />TOP CHORD DEAD LOAD 12 P5F <br />MECHANICAL AND ENERGY NOTES <br />BQT T QM CHORD DEAD LOAD 5 PSF <br />TOTAL LOAD 42 PSF <br />1. ALL WORK SHALL CONFORM TO THE INTERNATIONAL MECHANICAL <br />CODE, THE 2009 WA51-IINGTOiJ STATE ENERGY CODE ( AND THE <br />2003 SEATTLE SUPPLEMENT. IF APPROPRIATE.) <br />STANDARD TILE ROOF LOADING SHALL BE : <br />2. SEE BUILDING SECTION FOR, INSULATION RATING AND LOCATION. <br />TOP CHORD LIVE LOAD 25 P5F <br />3. KITCHFN RANGE FAN, EXHAUST PAN5, AND CLOTHES DRYERS SHALL <br />TOP CHORD DEAD LOAD 25 PSF <br />EXHAUST DIRECTLYTO THE OUTSIDE, VENTS SHALL BE SMOOTH, <br />BOTTOM CHORD DEAD LOAD 5 PSF <br />NON-COMBUSTIBLE, NONA135ORBENT AND EQUIPPED WITH BACKDRAFT <br />DAMPER. ALL EXHAUST OUTLETS SHALL TERMINATE AT LEAST <br />TOTAL AL LOAD 55 PSF <br />3 FEET FROM ANY OPENING INTO THE BUILDING PER IPC R303.4. <br />4. WASHINGTON STATE ENERGY CODE, GENERAL NOTES: <br />13. WOOD FLOOR TRUSSES SHALL BE DESIGNED IN ACCORDANCE <br />a. ELECTRICAL WATER, HEATER SHALL HAVE THE FOLLOWING PER <br />WITH APPROVED ENGINEERING PRACTICES. SUBMIT SHOP DRAWINGS <br />WSEC SECTION 504: <br />AND DESIGN CALCULATIONS (COMPLETED WITH STRESS DIAGRAMS) <br />I. SEPARATE POWER OR GAS SHUTOFF. <br />FOP, THE STRUCTURAL ENGINEER TO REVIEW PRIOR TO FABRICATION. <br />NONCOMBUSTIBLENAELABEL ANK(uNHEATED SPACES ONLY <br />SUBMITTED DOCUMENTS SHALL BEAR THE STAMPS AND SIGNATURE <br />ON <br />v. TEMPERATURE SETTING OF 120 DEGREES F. <br />OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF <br />b. SHOWER AND LAVATORIES SHALL LIMIT PLOW TO 2.G GPM (E. <br />WAS H I N GTON <br />504.8.1) <br />c. CEILING INSULATION: <br />14, WOOD ROOF TRUSSES SHALL UTILIZE APPROVED CONNECTOR <br />PLATES (GANGNAIL OR EQUAL). SUBMIT SHOP DRAWINGS AND <br />I. BAFFLES TO MAINTAIN 1"AIR SPACE ABOVE INSULATION <br />ii. BAFFLES To EXTEND 0 ABOVE BAI INSULATION <br />DESIGN CALCULA, T IONS (COMPLETED WITH STRESS DIAG-RAM5) FOR <br />III. BAFFLES TO EXTEND 12" ABOVE LOOSE FILL INSULATION. <br />THE STRUCTURAL ENGINEER TO REVIEW PRIOR TO FABRICATION, <br />d. WALL INSULATION SHALL BE: <br />SUBMITTED DOCUMENTS SHALL BEAR THE STAMPS AND SIGNATURE <br />i. FACED. STAPLED BATTS, OR <br />OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF <br />RETA DEOR E A FAIINT WITH A11DRY MILPOLY <br />MVROING <br />WASHINGTON, PROVIDE FOR SHAPES, BEARING POINTS, <br />RR. <br />OF 1.0 MAXIMUM. <br />INTERSECTIONS, HIPS, VALLEYS, ETC., SHOWN ON DRAWINGS. EXACT <br />e. CONCEALED INSULATION SHALL BE PLACED BEHIND SHOWER/ <br />COMP051 T ION OF SPECIAL HIP, VALLEY, AND INTERSECTION AREAS <br />TUB AND BEHIND PARTITION STUD/ CORNER. <br />(USE OF GIRDER TRUSSES, JACK TRUSSES, STEP-DOWN TRUSSES, <br />I. FLOOR INSULATION SHALL HAVE VAPOR BARRIER ON THE WARM <br />ETC.) SHALL BE DETERMINED BY THE MANUFACTURER UNLESS <br />SIDE. <br />SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS TO <br />o. ATTIC AND CRAWL SPACE ACCESS PANELS To Be INSULATED <br />TRUSS AND TRUSS TO GIRDER TRUSS CONNECTION DETAILS AND <br />AND WEATHER STRIPED, <br />REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY <br />h. RECESSED LIGHTING FIXTURES To COMPLY WITH N/5EC SECTION <br />AND PERMANENT TRUSS BRACING AND BRIDGING. IF TRUSS <br />502. 4.4 <br />CONFIGURATION DIFFERS FROM THAT SHOWN ON ARCHITECTURAL <br />I. VAPOR RETARDERS 51HALL BE INSTALLED PER5.502. I.C. <br />PLAN, THE MANUFACTURER SHALL CONTACT THE ARCHITECT AND <br />J. s-MIL BLACK POLYETHYLENE CPOUNDCOVER SHALLBELAPPED <br />ENGINEER TO VERIFY SUPPORTING FRAMING, ALL TRUSSES SHALL <br />12° ATJOINTAND EXTEND TO FOUNDATION WALL IN CRAWL <br />COMPLY WITH IRC R802. 10. <br />FACE. <br />k. ALL EXTERIOR DOOP5 (EXCEPT 20 MINUTE DOORS) SHALL BE <br />WEATHER STRIPPED PER 5,502.4.3, <br />15. WOOD STRUCTURAL PANEL SHEATHING (PLYWOOD AND 0513) <br />SHALL MEET REQUIREMENTS OF THE IRC R503.2, EACH PIECE SHALL <br />I. SERVICE HOT AND COLD WATER PIPING IN UNCONDITIONED <br />SPACES SHALL BE INSULATED TO THE MINIMUM VALUES <br />BARE THE RATING STAMP OF THE APPROPRIATE AGENCY, <br />LISTED IN TABLE 5-12 AND SECTION 503.1.1 . <br />m. EACH DWELLING UNIT SHALL BE PROVIDED WITH HEATING <br />I G. ALL STRUCTURAL PANEL COMPONENTS OF THE BUILDING SUCH AS <br />FACILITIES CAPABLE OF MAINTAINING 70 DEGRFE5 F AT A <br />SOFTWOOD PLYWOOD, PARTICLE BOARD, WAFER BOARD, AND OSB <br />POINT 3'-0" ABOVE THE FLOOR IN ALL HABITABLE ROOMS <br />wrIEIN' THE OUTSIDE TEMPERATURE IS As SET FORTH IN <br />SHEATHING SHALL BE IDENTIFIED A5 "EXTERIOR". <br />SECTION 305 WSEC, SECTION 31 0. 1 1 OF UBC. FUEL BURNING <br />APPLIANCES SHALL BE LISTED AND LABELED BY AN <br />APPROVED AGENCY AND INSTALLED AND VENTED <br />17. ADHERED AND ANCHORED VENEER SHALL CONFORM TO IRCR703, <br />ACCORDING TO SPECIFICATIONS. PROVIDE A MINIMUM CLEAR <br />WORKING SPACE OF 3" MINIMUM ALONC SIDES, BACK AND <br />STRUCTURAL SHAPES USED FOR ANCHORED MASONRY VENEER <br />TOP of APPLIANCE WITH 2" MINIMUM CLEARANCE TOTAL SIDE <br />LINTELS SHALL CONFORM TO R703,7, 2. 1. VENEER SHALL BE FLASHED <br />TO SIDE, <br />PER IRC R703,7.5 AND R703.8, <br />n. STANDARD AIR LEAKAGE (WSEC SECTION 502.4.3) CAULKING IS <br />COMPLETE WrIEN INSTALLED IN THE FOLLOWING LOCATIONS: <br />18, ANCHORED VENEER SHALL BE PROVIDED WITH CORROSION RESTS ANT <br />TE/ SUB FLOOR. <br />i1.51ETWIf NFSUIVBINOLE A DUCT REGISTER PENETRATIONS <br />ANCHOR TIES PER IKC K703.7.4. THE ANCHOR TIES SHALL BE SPACED <br />� . PIMJTIONS/MUDSILNETRATTEDLowERFI_ooRs) <br />A MAXIMUM OF 24" ON CENTER AND SUPPORT NO MORE THAT 2 <br />w. PARTITIONS/ 5TUD PENETRATIONS. <br />v. LIGHT FIXTURE/ FLUE FENETKATION5. <br />SQUARE FEET OF VENEER. ADDITIONAL VENEER TIES SHALL BE <br />vi. AROUND WINDOV✓ AND DOOR FRAMES <br />PROVIDED AROUND ALL WALL OPENINGS GREATER THAN I G" IN <br />WAS HSTATE VENTILATION AND INDOOR Ale <br />EITHER DIRECTION PER R703.7.4, 1. 1. <br />QUALITY CODE <br />QNOTES: <br />CODE <br />a. EACH DWELLING UNIT OR GUEST ROOM SHALL BE EQUIPPED WITH <br />ELECTRICAL NOTES <br />SOURCE SPECIFIC AND WHOLE MOUSE VENTILATION SYSTEMS <br />DESIGNED TO SATISFY THE REQUIREMENTS OF THE <br />WASHINGTON STATE VIASQ CHAPTER 3. <br />1. ALL ELECTRICAL MATERIALS, INORKL�AANSHIP AND CONSTRUCTION <br />b. MECHANICAL VENTILATION PAN DUCTS SHALL BE 4" OR PROPERLY <br />SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL <br />SIZED USING VIA5Q. TABLE 3.2 AND 3.3. <br />RESIDENTIAL CODE, INTERNATIONAL BUILDING CODE AND THE <br />cMECHANICAL VENTILATION SYSTEM5SHALL HAVE ATIMEP, <br />WASHINGTON STATE ELECTRICAL CODE, LATEST EDITION. VERIFY <br />GE. HUMIDSTAT OR SWITCH PER VIAQ. 5.302.3. 1. AND <br />VIA5Q.5.302.3.2 <br />ALL CONDITIONS BEFORE PROCEEDING WITH WORK, <br />d. MECHANICAL VENTILATION SYSTEMS SHALL HAVE P-4 <br />INSULATION IN UNCONDITIONED SPACES PLUS BACK-DPAFf <br />2. PROVIDE ELECTRICAL GROUND WIRES EMBEDDED IN FOUNDATION PEP <br />DAMPER. (VIAQ. 5.302.5) <br />ELECTRICAL CODE, <br />e. MECHANICAL VENTILATION SUPPLY DUCTS IN CONDITIONED <br />SPACES SHALL HAVE R-4 INSULATION. (VIASQ. 5.302.5) <br />3. 1 10 V HARD WIRED SMOKE DETECTORS WITH BATTERY BACKUP <br />f. SUPPLY DUCTS SHALL HAVE VOLUME DAMPERS; OP EQUIVALENT, <br />SHALL BE INSTALLED IN EACH SLEEPING ROOM AND IN ONE <br />TO BALANCE SYSTEM (WSEC 5.503.G) <br />CENTRAL LOCATION ON EACH STORY OR LEVEL, PREFERABLY <br />3. SUPPLY AND RETURN AIR, DUCTS SHALL HAVFSEALFDDUCT <br />JOINTS IN UNCONDITIONED SPACES (VI/SEC S.503. 10.2) <br />C,LO5E TO THE STAIR LANDING. EACH SMOKE DETECTOR SHALL BE <br />INTERCONNECTED 50 AS TO SOUND ALARMS IN EACH ROOM OR <br />h. EXHAUST FANS SHALL BE: <br />AREA IF ONE DETECTOR IS TRIGGERED, PER IRC R3 13 <br />FLOW RATED AT 0,25 W.G. STATIC PPE55URF <br />u. SOUND RATED AT I .5 SONE5 MAXIMUM FOR WHOLE <br />HOUSE PAN. <br />n. INSULATED TO 7.-4 IN UNCONDITIONED SPACES. <br />w. EQUIPPED WITH A BACKDPAFT DAMPER. <br />i. HVAC PLENUMS, SUPPLY, AND RETURN AIR DUCTS SHALL HAVE <br />DOOR AND WINDOW NOTES <br />R-8 INSULATION (WSEC TABLE 5-1 1 , ALL OPTICN5) <br />1. OUTDOOR AIR INLETS: INLETS SHALL BE SCREENED OR <br />1. EVERY 5LEEPING- ROOM AND HABITABLE ROOMS IN BASEMENTS SHALL <br />OTHERWISE PROTECTED FROM ENTRY BY INSECTS, LEAVES, <br />OR OTHER MATERIALS. OUTDOOR AIR INLETS SHALL BE <br />HAVE AI` LEAST ONE OPERABLE WINDOW WITH A NET CLEAR <br />LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING <br />OPENING OF 5.7 5F. THE OPENING HEIGHT SHALL BE 24" MINIMUM <br />AREAS: (VIAQ.5.302.(7-1) <br />AND WIDTH 20" MINIMUM, WITH A FINISHED SILL HEIGHT NO MORE THE <br />I. CLOSER THEN TEN FEET FROM AN APPLIANCE VENT <br />OUTLET, UNLESS SUCH VENT OUTLET 15 THREE FEET <br />44" ABOVE THE FLOOR, PEP, IRC R3 10. 1. IF WINDOW WELLS ARE <br />ABOVE AIR INLET, <br />NECESSARY THEY SHALL MEET THE REQUIREMENTS OF IRC R3 10.2. <br />NHEREHIT VAL'LDOOR PICK UP OBJECTIONABLE ODORS, FUMES <br />OR FLAMMABLE VAPORS. <br />". IN HAZARDOUS OF, UNSANITARY LOCATIONS, <br />iv. IN A ROOM OR SPACE HAVING FUEL -BURNING. <br />2. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE DESIGNED TO <br />APPLIANCES. <br />RESIST THE DESIGN WIND LOADS SPECIFIED IN TABLE R301 .2(2) AND <br />v. CLOSER THEN TEN FEET FROM A VENT OPENING TO A <br />PLUMBINGDRAINAGE SYSTEM UNLE55THE VENT <br />ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLE R30 1.23 . <br />( ) <br />OPENING IS AT LEAST THREE FEET ABOVE THE AIR INLET. <br />IN' <br />N AN ATTIC, CRAWL SPACE OR GARAGE. <br />3. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN <br />k. SOURCE SPECIFIC VENTILATION SHALL BE PROVIDED IN EACH <br />KITCHEN, BATHROOM, WATERCLO5ET, LAUNDRY ROOM, SPA, <br />APPROVED INDEPENDENT LABORATORY AND BEAR A LABEL <br />INDOOR SWIMMING POOL ENCLOSURE AND ANY OTHER <br />IDENTIFYING MANUFACTURER, PERFORMANCE CHARACTERISTICS <br />ROOMS WERE EXCESS WATER VAPOR OR ODOR IS <br />FRODUCED. <br />AND APPROVED INSPECTION AGENCY TO INDICATE COMPLIANCE <br />WITH THE REQUIREMENTS OF IPC RG 13.3. <br />1. WHOLE HOU5E VENTILATION SYSTEMS: EACH DWFLUNG UNIT <br />SHALL BE EQUIPPED WITH AWHOLE HOUSE VENTILATION <br />SYSTEM THAT SHALL BE CAPABLE OF PROVIDING AT LEAST <br />0.35 AIR CHANGES PER HOUR, BUT NOT LF55 THEN 15 CFM PER <br />4. WINDOW AND GLA55 DOOR ASSEMBLIES SHALE_ BE ANCHORED IN <br />BEDROOM PLUS AND .ADDITION 15 CFM. WHOLE HOUSE <br />ACCORDANCE WITH THE MINIMUM REQUIREMENTS ILLUSTRATED IN <br />VENTILATION SYSTEM SHALL SUPPLY OUTDOOR AIR TO ALL <br />HABITABLE ROOMS THROUGH INDIVIDUAL OUTDOOR AIR <br />IRC RG 13.5. <br />INLETS, FORCED AIR HEATING SYSTEMS, DUCTING OR <br />FQU I VALENT. <br />5. GLAZING IN HAZARDOUS LOCATIONS (AS OUTLINED IN IBC 240G.3) <br />FANTO EENSURE��BYUNo RCUTDOOv��RI�LS(VIAQ HousF <br />SUCH AS: <br />5.302.G.4) <br />a. PANES IN SWINGING, SLIDING, STORM OR BIFOLD DOORS, <br />n. ALL FIREPLACE5(VIAQ.5.402.3)SHALLHAVE: <br />b. GLAZING WITHIN 24" OF A DOOR OPENING, <br />c. GLA_71 NG IN STAIRWAYS, <br />I. G" SQUARE INCHESCOMBUSTIBLE AIR SUPFLYDUCT WITH <br />TIC -HT FI KING DAMPER DIRECTLY CONNECTED TO THE <br />d, GLAZING IN SHOWER OR TUB SURROUNDS <br />FIREBOX <br />e. GLAZING IN GUARDS AND RAILINGS <br />n. TIGHT FITTING GLA55 OR METAL DOORS. <br />TIGHTLY FITTINGH DAMPER V✓ITMANUAL OR <br />f. GLAZING CLOSET, THAN 1 8" TO A FLOOR <br />o. RADON MONITOR, PRINTED INSTRUCTIONS, AND INFORMATION <br />SHALL BE SAFETY GLAZING OR WIRE REINFORCED, TEMPERED OR <br />SHEET SHALL BE SUPPLIED TO THE SINGLE FAMILY DWELLING <br />OR FIRST FLOOR UNIT OF MULTIPAMLYDWELLINGBYTHE <br />LAMINATED SAFETY GLASS, OR SHATTER RESISTANT PLASTIC PER <br />GENERAL CONTRA(' TOP AS REQUIRED BY WA5HINGTON <br />STATE. <br />I. WHOLE HOUSE VENTILATION SYSTEMS: EACH DWELLING UNIT <br />SHALL BE EQUIPPED WITH A WHOLE HOUSE VENTILATION <br />SYSTEM THAT SHALL BE CAPABLE OF PROVIDING AT LEAST <br />0.35 AIR CHANGES PER HOUR, BUT NOT LESS THEN 15 CFM PER <br />BEDROOM PLUS AND ADDITION 15 CFM. WHOLE HOUSE <br />VENTILATION SYSTEM SHALL SUPPLY OUTDOOR AIR TO ALL <br />HABITABLE ROOMS THROUGH INDIVIDUAL OUTDOOR AIR <br />INLETS, FORCED AIR HEATING SYSTEMS, DUCTING OR <br />EQUIVALENT. <br />m. AIRFLOW BETWEEN FRESH AIR PORTS AND THE WHOLE HOUSE <br />FAN TO BE ENSURED BY UNDERCUT DOOR/ GRILLS (VIAQ. <br />S.302.G.4) <br />n. ALL FIREPLACES (VIAQ.5.402.3) SHALL HAVE: <br />I. G" SQUARE INCHES COMBUSTIBLE AIR SUPPLY DUCT WITH <br />TIGHT FITTING DAMPER DIRECTLY CONNECTED TO THE <br />FIREBOX <br />II. TIGHT FITTING GLA55 OR METAL DOORS. <br />ul. TIGHTLY FITTING FLUE DAMPER WITH MANUAL OR <br />AUTOMATIC CONTROLS <br />o. RADON MONITOR, PRINTED INSTRUCTIONS, AND INFORMATION <br />SHEET SHALL BE SUPPLIED TO THE SINGLE FAMILY DWELLING <br />OR FIRST FLOOR UNIT OF MULTIFAMILY DWELLING BY THE <br />GENERAL CONTRACTOR AS REQUIRED BY WASHINGTON <br />STATE. <br />INDEX Of P,\\AWP TAGS <br />AP\C1n'1TECT1 I <br />7 <br />RAL NOTE5 <br />/ 1-1 - <br />5CALE11- I oil - P <br />� - N <br />N L m <br />O <br />VIEW50 <br />-PERTINENT CODE <br />ate: July 23rd; 2020 <br />tale: as needed <br />Drawn by: GLMc <br />Hi EEi. <br />g. ALL CHIMNEYS SHALL EXTEND AT LEAST 2'-0" ABOVE THE <br />HIGHEST ELEVATION OF ANY PART OF THE BUILDING WITHIN 1 0'- <br />0" BUT SHALL NOT BE LESS THAN 3' ABOVE THE HIGHEST POINT <br />WHERE THE CHIMNEY PASSES THROUGH THE ROOF PER IRC <br />r inni � <br />IR,C K308,4 AND IBC 240G. GLAZING WITH THE EXPOSED EDGE <br />WITHIN A 24" ARCH OF THE VERTICAL EDGE OF A DOOR SHALL BE <br />SAFETY GLAZING FER IRC R308.4 <br />G. GLAZING IN SKYLIGHTS SHALL CONFORM TO IRC P308.G. <br />