3219 52ND PL SW 2021 Plans 2022-11-21
>
Address Records
>
52ND PL SW
>
3219
>
Plans
>
3219 52ND PL SW 2021 Plans 2022-11-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:20:47 AM
Creation date
7/21/2022 9:22:39 AM
Metadata
Fields
Template:
Address Document
Street Name
52ND PL SW
Street Number
3219
Permit
B2104-039
Year
2021
Notes
BASEMENT ALTERATION WHICH INCLUDES CHANGING LAYOUT AND
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CODE REQUIREMENTS-. <br />R314.1 GENERAL. SMOKE ALARMS SHALL COMPLY WITH <br />NPPA72 AND SECTION R314 IRC2018. <br />R314.2.2. WHERE ALTERATIONS, REPAIRS OR ADDITIONS <br />REQUIRING A PERMIT OCCUR, THE INDIVIDUAL DWELLING UNIT <br />SHALL BE EQUIPPED WITH SMOKE ALARM LOCATED AS <br />REQUIRE FOR NEW DWELLING. <br />EXCEPTIONS: <br />1.WORK INVOLVING THE EXTERIOR SURFACES OF <br />DWELLINGS,SUCH AS THE REPLACEMENT OF ROOFING OR <br />SIDING, THE ADDITION OR REPLACEMENT OF WINDOWS OR <br />DOORS, OR THE ADDITION OF A PORCH OR DECK. <br />2. INSTALLATION, ALTERATION OR REPAIRS OF PLUMBING OR <br />MECHANICAL SYSTEMS. <br />R314.7.4 COMBINATION DETECTORS COMBINATION <br />SMOKE/CARBON MONOXIDE DETECTORS SHALL BE PERMITTED <br />TO BE INSTALLED IN FIRE ALARM SYSTEMS IN LIEU OF SMOKE <br />DETECTORS, PROVIDED THEY ARE LISTED IN ACCORDANCE WITH <br />UL268 AND UL2075. <br />R315.1 GENERAL. CARBON MONOXIDE ALARMS SHALL COMPLY <br />WITH SECTION R315 IRC2018. <br />R315.1.1 LISTINGS. CARBON MONOXIDE ALARMS SHALL BE <br />LISTED IN ACCORDANCE WITH UL2034. COMBINATION CARBON <br />MONOXIDE/SMOKE ALARMS SHALL BE LISTED IN ACCORDANCE <br />WITH UL2034 AND UL217. <br />R315.2. WHERE REQUIRED. CARBON MONOXIDE ALARMS SHALL <br />BE PROVIDED IN ACCORDANCE WITH SECTION R315.2.1 AND <br />R315.2.2. <br />R315.3 LOCATION. CARBON MONOXIDE ALARMS IN DWELLING <br />UNITS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE <br />SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. <br />WHERE A FUEL -BURNING APPLIANCE IS LOCATED WITHIN A <br />BEDROOM OR ITS ATTACHED BATHROOM, A CARBON MONOXIDE <br />ALARM SHALL BE INSTALLED WITHIN THE BEDROOM, <br />DRYER VENTILATION NOTE. - <br />DRYERS SHALL VENT TO OUTSIDE <br />DRYER VENT:2018 IRC M1502.4.6. LENGTH IDENTIFICATION. THE <br />MAXIMUM LENGTH OF THE EXISTING DUCT SHALL BE 35 FEET <br />FROM THE CONNECTION TO THE TRANSITION DUCT FROM THE <br />DRYER TO THE OUTLET TERMINAL.WHERE THE EXHAUST DUCT <br />EQUIVALENT LENGTH EXCEEDS 35" THE EQUIVALENT LENGTH <br />OF THE EXHAUST DUCT SHALL BE IDENTIFIED ON A <br />PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE <br />LOCATED WITHIN 6" OF THE EXHAUST DUCT CONNECTION. <br />EXHAUST DUCT JOINTS SHALL BE SEALED IN ACCORDANCE <br />WITH SECTION M1601.4.1 AND SHALL BE MECHNICALLY <br />FASTENED. <br />M1502.3.1. DRYER EXHAUST DUCT TERMINATION. A MINIMUM <br />AREA OF 12.5 SQUARE INCHES HAS BEEN ESTABLISHED THE <br />TERMINAL OUTLET OF DRYER DUCT EXHAUST. <br />M1502.4.2 CONCEALED DRYER EXHAUSTED DUCTS. WALL AND <br />CEILING CAVITIES ENCLOSING DRYER EXHAUST DUCT MUST <br />PROVIDE SUFFICIENT SPACE THAT 4—INCH DUCT IN NOT <br />SQUEEZED OUT OF ITS ROUND SHAPE. <br />EVACUATION NOTES: <br />BASEMENTS,HABI TABLE ATTICS AND EVERY SLEEPING ROOM <br />SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE <br />AND RESCUE OPENING.WHERE BASEMENTS CONTAIN ONE OR <br />MORE SLEEPING ROOMS, EMERGENCY EGRESS AND RESCUE <br />OPENINGS SHALL BE REQUIRED IN EACH SLEEPING ROOM. <br />WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE <br />PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE <br />THAN 44" ABOVE THE FLOOR, THE NET CLEAR OPENING <br />DIMENSIONS REQUIRED BY SECTION SHALL OBTAINED BY <br />NORMAL OPERATION OF THE EMERGENCY ESCAPE RESCUE <br />FROM INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS <br />SHALL OPEN DIRECTLY INTO A PUBLIC WAY, OR TO A YARD <br />OR COURT THAT OPENS TO A PUBLIC WAY. (2018 IRC R310.1) <br />MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND <br />RESCUE OPENING SHALL HAVE A MINIMUM NET CLEAR <br />OPENING OF 5.7sgF. <br />EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM <br />NET CLEAR OPENING OF 5 sqF (2018 IRC R310.1.1) <br />MINIMUM OPENING HEIGHT. MINIMUM NET CLEAR OPENINGS <br />HEIGHT SHELL BE 24"(2018 IRC R310.1.2) <br />MINIMUM OPENING WIDTH. THE MINIMUM NET CLEAR OPENING <br />WIDTH SHALL BE 20" (2018 IRC R310.1.3) <br />--------------------------------- <br />I TOTAL 6 IN ROW <br />1 <br />I I <br />E-4X1O FLOOR JOISTS I <br />I VERIFY I <br />i I <br />C�28 1 /2""O.C.-EXPOSED <br />I E-SLDR 70 3/4"X35" E-SLDR 70 3/4"X35"I <br />I SLDR DR70'°X82" F.F. 44" F.F. 44",EGRESS I <br />�- <br />I I I <br />- <br />E-FIR PLACE.' <br />H L7UHUUM <br />�ENTERTAINIMENT AREA <br />E—FAN' <br />1 OOCFM ' <br />f <br />E- S.D. xl <br />H CEILING 92„ <br />-x <br />v� A xl <br />� I <br />I� <br />> i <br />A07 <br />LIJ <br />EXISTING FOUNDATION-3fi®��_ _________�_-Ln <br />E-SEAM -_ ��_ I�'II E-ECM <br />- ---_------ �_-- _ _- -=_- I. <br />14R�UP Xi <br />XI <br />6X6DF1�i POST iW/ CCQ' 10 f12 i,x <br />i CAP TOi FIT POST AND BM. <br />HANDRAIL 0 3 <br />x, <br />ASAE STAIR NbSING ix <br />- _ FOdTI NG 3�"X36"X!12" - x <br />6 (4) 4 EW OT TO BE <br />BEFORE REUOVING EXISTINGWALL, JOISTS OR DEAMS, CONTACT C09TRACTOR <br />FOR TUNING AND FIELD vERIFICATloAi OF EXISTING STRUCTURAL CONDITIONS <br />LOCATION AND SIZES OF SHORING REQUIRING FOR PROPER STRUCTURAL SUPPORT <br />DURING CONSTRUCTION FOR SAFITY AND MINIMIZE DAMAGE TO G),P AND CRACKING <br />E—SLDR 70 3/4"`X38" <br />F.F. 44", EGRESS <br />xl E—FURRING,VERIFY <br />XEe <br />77 <br />Xi <br />x <br />'x <br />,v I B;EDRJD <br />I26 <br />! E- <br />s <br />L 6 <br />J <br />9 xJ <br />0 1 <br />--- l VERYFIED. EXISTING <br />--- UTILITY/ TOR `',G <br />- - E-FURN�. x <br />xl <br />I 4 xij <br />i <br />X_71. <br />Ow <br />4 <br />s <br />2 BATIK' <br />7x ;x <br />E-FAN` <br />50CFM <br />D "'o <br />2XI WH <br />; <br />J'L 112 <br />LAUNDRY i - <br />SOCFM x-1 <br />-I W/D x <br />I-_ ___!! _J <br />I <br />E—CRAWL <br />SPACE ACCESS <br />CRAWL SPACE <br />Lj� ('�rOv <br />1. ALL EXTERIOR WALLS SHALL BE 2x6 H/F/ 2 OR BETTER @16"O.0 (O.U.. <br />2. ALL INTERIOR WALLS SHALL BE 2x4 HIF1112 OR BETTER §16"0.C.(U,N.0., <br />3 HEADERS 4x10 DF12 (U.N.O.), OTHER411SE NOTED <br />4. ALL FRAMING HARDWARE TO BE "SIMPSON" OR EQUAL, <br />REQUIREMENTS <br />1, PLANS SHOULD 6E REVIEWED 6Y ALL SU6CONTRACTORS PRIOR TO <br />STARTING CONSTRUC77004 IF DISCREPANCIES EXIST PLEASE CONTACT <br />ARCHITECT OR O NERICONIRACTOR <br />2. ALL Yd00D IN CONTACT WITH CO,NCREIZ-, k9ASONRY, EARN, OR EXPOSED <br />TO FEATHER SHALL 6E PRESSURE TREATED. <br />3 WRIFY ALL DIMENSIONS AND FIELD COND/TTONS <br />4. PROVIDE 2X6 BLOCKING BEHIND ALL BARS, RINGS & HOLDERS <br />D. PROVIDE SLOWER W/WA TER -PROOF TO A MIN, OF 72" ABOVE DRAIN INL. <br />PLACE WA TER -PROOF BACKING TO SAME HEIGHT OR GREA TER. <br />6. FETAL FRAMING CONNECTORS SPECIFIED ARE MANUFACTURED BY THE <br />SIMPSON COMPANY SEE LATEST CATALOG E91710. INSTALL PER SPECS <br />USE ONL )" EQUIVALENT SUSS1TTU71ONS. <br />7 ALL METAL CONNECTORS SUPPORTED 6Y PRESSURE TREATED MATERIAL <br />SHALL 6E WAX" (G185 HDG PER ASTM A653) OR EQUIVALENT AND <br />FASTENERS SHALL 6E PER ASTM A153, <br />NOTE: <br />FASTEN PT 2X4 SILL PLATE <br />FOR NEW PARTITIONS BY <br />SPLIT DRIVE CONCERETE <br />I ANCHOR 3" LONG @24" O.C. <br />CN-00 <br />LL� EXISTING WATER HEATEDLIJ <br />VERIFY <br />STRAP WH TO MALL PER I.M.0 <br />50 GAL WATER HEATER <br />MECH. EQUIP, SHALL BE SET ON <br />18" PLATFORM W/ NON-COMBUSTIBLE <br />LEGEND <br />DENOTES EXISTNG $W LS REPAIN <br />L - -- - DENOTES MALL TO 6E 100VED <br />F% i E: ,,,,, >> ; DENOTES THE NEe MALLS <br />50 CFM EXHAUST FAN VENTED TO OUTSIDE. <br />CAR60/II MONOXIDE DETECTOR <br />110 VOLT SWAT DETECTOR <br />WELT E &NEERNG DESIGN, PLLC <br />I Structural Review <br />This review Is for general conformance to the <br />structural design crlterla, red lined mark-ups, <br />concept and contract documents. <br />. .lJ C! �- /' Date 0 1 <br />�EX TIRE 0 <br />PROPOSED BASEMENT FLOOR PLAN <br />scale <br />1/4 <br />1�_C <br />0 <br />rr) <br />110 <br />__J 0T) <br />CN <br />_ <br />LLJ <br />C� <br />Q <br />EL <br />O <br />0 <br />1 <br />CN <br />LL_ <br />Q <br />CN <br />{— <br />F__ <br />CD <br />LLJ <br />= <br />d� <br />LLJ <br />0 <br />LLB <br />I— <br />LLJ <br />� <br />l.d JJ <br />0 <br />IL <br />0 <br />n <br />2020-82-IR <br />