EXISTING CONSTRUCTION <br />1. EXISTING STRUCTURAL DIMENSIONS AND MEMBERS SIZES ARE FOR REFERENCE ONLY. <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO FABRICATION. <br />THE CONTRACTOR SHALL VERIFY THE ACTUAL CONFIGURATION OF EXISTING <br />CONSTRUCTION AND THE CONDITION OF THE STRUCTURE BEFORE BEGINNING WORK, <br />ANY DISCREPANCIES OR UNSOUND CONDITIONS SHALL BE REPORTED TO THE <br />STRUCTURAL ENGINEER FOR RESOLUTION BEFORE BEGINNING WORK. REFER TO <br />ARCHITECTURAL, PLANS FOR DIMENSIONS, EMBEDMENTS AND OPENINGS NOT SHOWN. <br />REFER TO MECHANICAL, PLUMBING AND ELECTRICAL PLANS FOR DUCTS, PIPING, <br />EMBEDMENTS, AND OPENINGS NOT SHOWN. <br />2. TEMPORARY SHORING AND BRACING MAY BE NECESSARY IN ORDER TO PERFORM THE <br />NECESSARY STRUCTURAL MODIFICATIONS TO THE EXISTING STRUCTURE SHOWN ON <br />THE STRUCTURAL AND ARCHITECTURAL DRAWINGS. THE CONTRACTOR MUST SUBMIT <br />PLANS AND SUPPORTING CALCULATIONS PREPARED BY A DESIGN PROFESSIONAL <br />LICENSED TO PERFORM WORK IN THE PROJECT JURISDICTION. <br />3. WHERE NEW STRUCTURAL WORK IS BEING PERFORMED, THE CONTRACTOR SHALL <br />VERIFY ALL DIMENSIONS AS REQUIRED PRIOR TO CONSTRUCTION. ANY <br />DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT FOR RESOLUTION PRIOR TO <br />BEGINNING WORK. <br />4. EXISTING CONSTRUCTION, FRAMING MEMBERS AND DIMENSIONS HAVE BEEN <br />ESTABLISHED BASED ON REVIEW OF THE AVAILABLE CONSTRUCTION DRAWINGS FOR <br />THE ORIGINAL BUILDING. ONLY LIMITED FIELD VERIFICATION HAS BEEN PERFORMED. <br />ANY DISCREPANCIES CONCERNING HOW NEW WORK RELATED TO THE AS -BUILT <br />CONSTRUCTION SHALL BE REPORTED TO THE STRUCTURAL ENGINEER FOR RESOLUTION <br />PRIOR TO BEGINNING WORK. <br />5. UNLESS SPECIFIED OTHERWISE, LOCATION AND ELEVATION OF NEW STRUCTURAL <br />ELEMENTS WITHIN THE EXISTING STRUCTURE ARE DETERMINED BY THEIR RELATIONSHIP <br />TO EXISTING CONDITIONS, THESE RELATIONSHIPS ARE NOTED ON THE PLANS, <br />SECTIONS AND DETAILS. <br />6, WHEN PROVIDED, DEMOLITION DRAWINGS INDICATE DEMOLITION EXTENT ASSOCIATED <br />WITH THE ACTUAL SIZE OF THE NEW ELEMENT. THE EXTENT OF DEMO MAY NOT <br />REFLECT ADDITIONAL DEMOLITION REQUIRED TO INSTALL NEW ELEMENTS. IN ADDITION <br />TO WHAT IS SHOWN ON THE ARCHITECTURAL DEMOLITION DRAWINGS, MINOR LOCAL <br />DEMOLITION OF EXISTING ELEMENTS MAY BE REQUIRED TO PERFORM THE <br />STRUCTURAL WORK AS INDICATED ON THE PLANTS, SECTIONS AND DETAILS. <br />DEMOLITION <br />1. ALL DEMOLITION SHALL BE CARRIED ON IN SUCH A MANNER AS NOT TO DAMAGE <br />EXISTING ELEMENTS WHICH ARE TO REMAIN A PART OF THE FINISHED STRUCTURE. <br />2. EXISTING ELEMENTS SHALL BE PROTECTED TO THE FULLEST EXTENT POSSIBLE TO <br />REDUCE SUCH DAMAGE TO A MINIMUM. <br />3. ALL ELEMENTS OF THE STRUCTURE THAT ARE TO REMAIN AND WHICH ARE DAMAGED <br />DURING DEMOLITION WORK SHALL BE REPLACED AT NO ADDED COST. <br />SPECIAL INSPECTION <br />1. SPECIAL INSPECTION BY A REGISTERED DEPUTY BUILDING INSPECTOR, IN CONTRACT <br />WITH THE OWNER AND APPROVED BY THE BUILDING OFFICIAL, SHALL BE REQUIRED <br />FOR THE FOLLOWING TYPES OF WORK (SEE THE PROJECT SPECIFICATIONS FOR <br />FURTHER REQUIREMENTS): <br />ITEM BUILDING CODE <br />REFERENCE <br />STEEL 1705.2 AND <br />AISC 360 CHAPTER N <br />DETAIL VERIFICATION <br />WELDING OF STRUCTURAL STEEL <br />HIGH STRENGTH BOLTING <br />2. SPECIAL INSPECTIONS SHALL NOT BE REQUIRED WHEN THE WORK IS DONE ON THE <br />PREMISES OF A FABRICATOR REGISTERED AND APPROVED BY THE BUILDING OFFICIAL <br />TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. CERTIFICATES OF <br />COMPLIANCE SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FROM THE <br />FABRICATORS OR MANUFACTURERS OF THE FOLLOWING COMPONENTS: <br />STRUCTURAL STEEL <br />3. EPDXY OR EXPANSION TYPE ANCHORS SHALL BE APPROVED BY THE BUILDING <br />OFFICIAL FOR THEIR USE AND SHALL BE INSTALLED ACCORDING TO THE <br />MANUFACTURER'S RECOMMENDATIONS AND ICC PRODUCT APPROVAL CONDITIONS. <br />4. NONDESTRUCTIVE INSPECTION OF ALL WELDS, SHOP AND FIELD, OF <br />MOMENT -RESISTING FRAMES SHALL BE PROVIDED IN ACCORDANCE WITH THE <br />GOVERNING CODE. <br />5. SUMMARY REPORTS OF ALL INSPECTIONS AND TEST RESULTS SHALL BE DISTRIBUTED <br />TO THE OWNER, STRUCTURAL ENGINEER, AND BUILDING OFFICIAL WITH DEFICIENCIES <br />CLEARLY NOTED. <br />6. DEFICIENCIES SHALL BE REPORTED TO THE CONTRACTOR ON A DAILY BASIS. <br />7. DEFINITIONS OF SPECIAL INSPECTIONS AND TESTING FREQUENCY: <br />A. (PER) PERIODIC OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION BY AN <br />APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE <br />WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF THE <br />WORK. <br />B. (CONT) CONTINUOUS OBSERVATION OF WORK REQUIRING SPECIAL INSPECTION <br />BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE <br />THE WORK IS BEING PERFORMED. <br />SPECIAL INSPECTION CONT. <br />8. STEEL INSPECTIONS <br />A. WELDS, PRIOR TO WELDING <br />i. (CONT) WELDING PROCEDURE SPECIFICATIONS (WPSS) AVAILABLE. <br />ii. (CONT) MANUFACTURE CERTIFICATIONS FOR WELDING CONSUMABLES <br />AVAILABLE. <br />iii. (PER) MATERIAL IDENTIFICATION (TYPE/GRADE). <br />iv. (PER) WELDER IDENTIFICATION SYSTEM - THE FABRICATOR OR ERECTOR, <br />AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO <br />HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIED. <br />V. (PER) FIT -UP OR GROVE WELDS (INCLUDING JOINT GEOMETRY). <br />vi. (PER) CONFIGURATION AND FINISH OF ACCESS HOLES. <br />vii. (PER) FIT -UP OF FILLET WELDS. <br />viii. (PER) CHECK WELDING EQUIPMENT. <br />B. WELDS, DURING WELDING <br />i. (PER) USE OF QUALIFIED WELDERS. <br />ii. (PER) CONTROL AND HANDLING OF WELDING CONSUMABLES. <br />iii. (PER) NO WELDING OVER CRACKED WELDS. <br />iv. (PER) ENVIRONMENTAL CONDITIONS. <br />V. (PER) WPS FOLLOWED. <br />vi. (PER) WELDING TECHNIQUES. <br />C. WELDS, AFTER WELDING <br />i. (PER) WELDS CLEANED. <br />ii. (CONT) SIZE, LENGTH AND LOCATION OF WELDS. <br />iii. (CONT) WELDS MEET VISUAL ACCEPTANCE CRITERIA. <br />iv. (CONT) ARC STRIKES. <br />V. (CONT) K-AREA (WHEN WELDING OF DOUBLER PLATES, CONTINUITY <br />PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE K-AREA, <br />VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 31N OF THE <br />WELD. <br />vi. (CONT) BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED). <br />vii. (CONT) REPAIR ACTIVITIES. <br />viii. (CONT) DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR <br />MEMBER. <br />D. NONDESTRUCTIVE WELD TESTING <br />i. CJP WELDS - ULTRASONIC TESTING SHALL BE PERFORMED ON ALL CJP <br />JOINTS IN MATERIALS 5/16 INCH AND THICKER. <br />ii. WELD ACCESS HOLES IN MATERIALS 1 1 /2 INCH OR THICKER - <br />FLANGES SHALL BE TESTED USING MAGNETIC PARTICLE OR PENETRANT <br />TESTING. <br />iii. AFTER JOINT COMPLETION, BASE METAL THICKER THAN 1 % INCH WHERE <br />THE CONNECTED MATERIAL IS GREATER THAN 3/4 INCH, AND CONTAINS <br />CJP GROOVE WELDS, SHALL BE ULTRASONICALLY TESTED. <br />iv. REDUCED BEAM SECTION REPAIR - MP TESTING SHALL BE PERFORMED <br />ON ANY WELD AND ADJACENT AREA OF THE REDUCED BEAM SECTION <br />CUT SURFACE THAT HAS BEEN REPAIRED BY WELDING, OR ON THE BASE <br />METAL OF THE REDUCED BEAM SECTION CUT SURFACE IF A SHARP <br />NOTCH HAS BEEN REMOVED BY GRINDING. <br />V. WELD TAB REMOVAL SITES - AT THE END OF WELDS, WHERE WELD <br />TABS HAVE BEEN REMOVED, MPT SHALL BE PERFORMED ON THE SAME <br />BEAM -TO -COLUMN JOINTS RECEIVING UT. <br />E. BOLTS, PRIOR TO BOLTING <br />i. (CONT) MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER <br />MATERIALS. <br />ii. (PER) FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS. <br />iii. (PER) PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, <br />TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR <br />PLANE). <br />iv. (PER) PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL. <br />V. (PER) CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING <br />SURFACE CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET <br />APPLICABLE REQUIREMENTS. <br />vi. (PER) PRE -INSTALLATION VERIFICATION TESTING BY INSTALLATION <br />PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES <br />AND METHODS USED. <br />vii. (PER) PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND ER <br />FASTENER COMPONENTS. <br />F. BOLTS, DURING BOLTING <br />i. (PER) FASTENERS ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL <br />HOLES AND WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED. <br />ii. (PER) JOINT BROUGHT TO THE SNUG -TIGHT CONDITION PRIOR TO THE <br />PRETENSIONING OPERATION. <br />iii. (PER) FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED <br />FROM ROTATING. <br />iv. (PER) FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC <br />SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID <br />POINT TOWARD THE FREE EDGES. <br />G. BOLTS, AFTER BOLTING <br />i. (CONT) DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED <br />CONNECTIONS. <br />SPECIAL INSPECTION CONT. <br />H. OTHER STEEL INSPECTIONS <br />i. (PER) VERIFICATION OF STRUCTURAL STEEL DETAILING - VERIFY <br />COMPLIANCE WITH THE DETAILS SPECIFIED ON THE STRUCTURAL <br />DRAWINGS. <br />ii. (CONT) ANCHOR RODS/EMBEDS - VERIFY MATERIAL, GRADE, DIAMETER, <br />LENGTH AND TYPE OF ELEMENT AND EMBEDMENT DEPTH. <br />iii. (CONT) PROTECTED ZONE - NO HOLES AND UNAPPROVED ATTACHMENTS <br />MADE. <br />iv. (CONT) RBS GEOMETRY REQUIREMENTS, IF APPLICABLE. <br />STRUCTURAL OBSERVATION <br />1. STRUCTURAL OBSERVATION IS REQUIRED FOR THE STRUCTURAL SYSTEM IN <br />ACCORDANCE WITH THE GOVERNING CODE. STRUCTURAL OBSERVATION IS THE VISUAL <br />OBSERVATION OF THE ELEMENTS AND CONNECTIONS OF THE STRUCTURAL SYSTEMS <br />AT SIGNIFICANT CONSTRUCTION STAGES AND THE COMPLETED STRUCTURE FOR <br />GENERAL CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL <br />OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED <br />OF THE BUILDING INSPECTOR OR THE DEPUTY INSPECTOR. <br />2. THE OWNER SHALL EMPLOY AN ENGINEER LICENSED TO PERFORM STRUCTURAL <br />OBSERVATION IN THE PROJECT JURISDICTION. <br />3, THE STRUCTURAL OBSERVER SHALL PROVIDE A LETTER TO BE SUBMITTED TO THE <br />BUILDING OFFICIAL, AS REQUIRED BY THE JURISDICTION, BEFORE THE FIRST SITE <br />VISIT. THE STRUCTURAL OBSERVER SHALL ALSO INFORM THE OWNER OF THE <br />REQUIREMENTS FOR A PRECONSTRUCTION MEETING AND SHALL PRESIDE OVER THIS <br />MEETING. <br />4. THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE COMMUNICATION <br />BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, <br />STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND SPECIAL <br />INSPECTORS. THE PURPOSE OF THIS COMMUNICATION SHALL BE TO IDENTIFY THE <br />MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND <br />LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE <br />REQUIRED OBSERVATIONS. <br />5. REPORTS SHALL BE ISSUED FOR EACH STRUCTURAL OBSERVATION AND ISSUED TO <br />THE OWNER, ARCHITECT, CONTRACTOR AND BUILDING OFFICIAL. A RECORD OF THE <br />PRECONSTRUCTION MEETING NOTED ABOVE SHALL BE INCLUDED IN THE FIRST <br />OBSERVATION REPORT, <br />6. THE CONTRACTOR SHALL SCHEDULE EACH OBSERVATION AT LEAST TWO WEEKS PRIOR <br />TO DATE OF THE PROPOSED OBSERVATION. <br />7. THE STRUCTURAL OBSERVER SHALL PERFORM OBSERVATIONS AT THE FOLLOWING <br />SIGNIFICANT CONSTRUCTION STAGES: <br />CONSTRUCTION STAGES ELEMENTS/CONNECTIONS TO BE OBSERVED <br />a) AT SUBSTANTIAL COMPLETION OF THE PRIMARY STRUCTURE. <br />SUBMITTALS <br />1. THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION/ERECTION/INSTALLATION. THESE <br />ITEMS ARE IN ADDITION TO ANY SUBMITTAL REQUIREMENTS SPECIFIED ON THESE <br />PLANS OR IN THE PROJECT SPECIFICATIONS. <br />STRUCTURAL SUBMITTALS <br />ITEM <br />PROD <br />DATA <br />SHOP <br />DWGS <br />TEST <br />RESULTS <br />CALCS <br />BLDG <br />DEPT <br />STRUCTURAL STEEL <br />- <br />YES <br />- <br />- <br />- <br />GROUT, EPDXY, ANCHORS <br />YES <br />- <br />- <br />- <br />- <br />2. "PROD DATA" - SUBMIT ADEQUATE DOCUMENTATION THAT THE PRODUCT PROPOSED <br />TO BE USED MEETS THE REQUIREMENTS ON THESE PLANS AND THE PROJECT <br />SPECIFICATIONS. <br />3. "SHOP DWGS" - SUBMIT COMPLETE SHOP DRAWINGS SUFFICIENT TO SHOW <br />QUANTITIES AND KINDS OF MATERIALS, METHODS OF ASSEMBLY, AND ALL DATA <br />REQUIRED FOR FABRICATION, ERECTION, AND INSTALLATION. THE PURPOSE OF THESE <br />DRAWINGS IS TO DEMONSTRATE THAT THE CONTRACTOR UNDERSTANDS THE DESIGN <br />CONCEPT DOCUMENTED HEREIN. SUBMITTALS CONSISTING OF DRAWINGS TAKEN <br />DIRECTLY FROM THESE PLANS WILL NOT BE APPROVED. IF DEVIATIONS, <br />DISCREPANCIES OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS AND THE <br />CONTRACT DOCUMENTS ARE DISCOVERED, EITHER PRIOR TO OR AFTER REVIEW BY <br />THE STRUCTURAL ENGINEER, THE DESIGN DRAWINGS AND SPECIFICATIONS SHALL <br />CONTROL AND SHALL BE FOLLOWED. RESPONSIBILITY FOR ADHERENCE TO THE <br />CONTRACT DOCUMENTS LIES SOLELY WITH THE CONTRACTOR. DIMENSIONS AND <br />QUANTITIES ARE NOT REVIEWED BY THE STRUCTURAL ENGINEER AND THEREFORE <br />MUST BE VERIFIED BY THE CONTRACTOR. <br />4. "TEST RESULTS" - SUBMIT RESULTS FOR ANY TESTING REQUIRED BY BUILDING CODE <br />OR THESE PLANS. <br />SUBMITTALS CONT. <br />5. "CALCS" - SUBMIT SIGNED AND SEALED PREPARED BY A DESIGN PROFESSIONAL <br />AUTHORIZED TO PERFORM WORK IN THE PROJECT JURISDICTION. CALCULATIONS <br />SHALL INDICATE THE MAGNITUDE AND DIRECTION OF ALL LOADS IMPOSED ON THE <br />BASIC STRUCTURE. THE COMPONENT DESIGNER SHALL BE RESPONSIBLE FOR CODE <br />CONFORMANCE AND ALL NECESSARY CONNECTIONS NOT SPECIFICALLY CALLED OUT <br />ON THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. <br />6. "BLDG DEPT" -- IF CHECKED, THE SUBMITTALS SHALL BE REVIEWED AND APPROVED <br />BY THE BUILDING OFFICIAL PRIOR TO FABRICATION AND/OR INSTALLATION. <br />7, THE CONTRACTOR SHALL REVIEW, STAMP AND APPROVE SUBMITTALS PRIOR TO <br />REVIEW BY THE STRUCTURAL ENGINEER. UNREVIEWED OR UNSTAMPED SUBMITTALS <br />WILL BE RETURNED TO THE CONTRACTOR UNREVIEWED. <br />8. THE CONTRACTOR SHALL ALLOW TWO WEEKS FOR REVIEW OF SUBMITTALS. <br />COMMENTS OR MARKS ON SUBMITTALS ARE A NORMAL AND EXPECTED PART OF THE <br />SUBMITTAL PROCESS AND SHALL NOT BE USED AS A BASIS FOR CHANGE ORDERS. <br />TIME REQUIRED TO REVISE AND RESUBMIT ANY SUBMITTAL SHALL BE CONSIDERED <br />INHERENT IN THE TO THE SUBMITTAL REVIEW PROCESS AND SHALL NOT BE DEEMED <br />A CHANGE ORDER. <br />9. RESUBMITTALS SHALL HAVE ALL REVISIONS CLEARLY IDENTIFIED WITH DRAWING <br />CLOUDS AND REVISION DATES. THE STRUCTURAL ENGINEER SHALL NOT BE <br />RESPONSIBLE FOR THE REVIEW OF ANY UNMARKED REVISIONS. <br />10. CONTRACTOR REQUESTED CHANGES OR SUBSTITUTIONS SHALL BE SUBMITTED IN <br />WRITING TO THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR <br />CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS <br />REQUIREMENT. CONTRACTOR WILL BE RESPONSIBLE FOR ANY ADDITIONAL <br />ENGINEERING EFFORT AND ASSOCIATED FEES REQUIRED FOR REVIEW AND APPROVAL <br />OF REQUESTED CHANGES AND SUBSTITUTIONS. <br />STRUCTURAL STEEL, MISC. METAL <br />1. STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE <br />BUILDING CODE AND AISC STANDARDS USING LOADS AS DEFINED IN AISC-360 <br />SECTION B3-3 "DESIGN FOR STRENGTH USING LOAD AND RESISTANCE FACTOR <br />DESIGN (LRFD)". <br />2. STRUCTURAL STEEL FABRICATION, ERECTION AND DIMENSIONAL TOLERANCES OF <br />STRUCTURAL STEEL MEMBERS SHALL CONFORM TO AISC REQUIREMENTS AND THE <br />PROJECT SPECIFICATIONS. <br />3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING, UNLESS OTHERWISE NOTED <br />ON THE STRUCTURAL DRAWINGS: <br />A. WIDE FLANGE SHAPES ASTM A992, Fy = 50 KSI <br />B. PLATES AND BARS ASTM A36, Fy = 36 KSI <br />C. CHANNELS AND ANGLES ASTM A36, Fy = 36 KSI <br />D. HOLLOW ROUND SECTIONS ASTM A500-B, Fy = 42 KSI <br />E. HOLLOW RECTANGULAR SECTIONS ASTM A500-13, Fy = 46 KSI <br />F. ROUND PIPE ASTM A53-13, Fy = 35 KSI <br />G. ANCHOR RODS EMBEDDED IN CONCRETE ASTM F1554 GRADE 36 <br />H. CONNECTION BOLTS A325-N-STD <br />4. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW <br />AND APPROVAL PRIOR TO THE START OF FABRICATION. <br />5. WELDING SHALL BE PERFORMED IN ACCORDANCE WITH AWS REQUIREMENTS. ALL <br />WELDS SHALL BE PREQUALIFIED IN ACCORDANCE WITH AWS AND AISC STANDARDS. <br />USE E70XX ELECTRODES, UON. <br />6. ALL WELDS SHALL BE PERFORMED BY WELDERS CERTIFIED IN THE JURISDICTION <br />HAVING AUTHORITY OVER THIS PORTION OF THE WORK. <br />7. WELD LENGTHS CALLED FOR ON THE PLANS ARE THE NET EFFECTIVE LENGTH <br />REQUIRED. WELD SIZE SHALL BE AISC MINIMUM, UON. <br />8. BOLTED CONNECTIONS OF MEMBERS MARKED 'SLRS' OR CONNECTIONS NOTED AS <br />SLIP CRITICAL SHALL BE PRETENSIONED AND SHALL MEET THE REQUIREMENTS FOR A <br />CLASS A FAYING SURFACE. CONNECTIONS AT THESE MEMBERS SHALL BE MADE USING <br />STANDARD HOLES IN ALL PLYS. <br />9. PENETRATIONS OF ANY SIZE IN ANY AREA OF THE MEMBER MUST BE REVIEWED AND <br />APPROVED BY THE STRUCTURAL ENGINEER. <br />10. BEAMS AND GIRDERS SHALL NOT SUPPORT PIPING LARGER THAN 10" DIAMETER <br />WITHOUT THE REVIEW OF THE STRUCTURAL ENGINEER OF RECORD. <br />11. TENSION CONTROL BOLTS MAY BE SUBSTITUTED FOR THE BOLTS SPECIFIED IN THESE <br />PLANS AT THE DISCRETION OF THE CONTRACTOR. ASTM F1852 TC BOLTS MAY BE <br />SUBSTITUTED FOR ASTM A325 BOLTS AND ASTM F2280 TC BOLTS MAY BE <br />SUBSTITUTED FOR ASTM A490. <br />