Laserfiche WebLink
FAN DECK (BETWEEN COL 1 — 2, LOOKING WEST) <br />a <br />J <br />® 1/4" P1723 UNISTRUT <br />L BRACKET TO <br />RESTRAIN FIXTURE <br />4 (TYPICAL OF 4) <br />J <br />12 GR 36 PL 1/4 x 30" x 30" <br />STEEL ESCUTCHEON PLATE <br />12 PROVIDE IDEAL 102 <br />POWERPLUG CONNECTOR <br />J BOX MOUNTED TO <br />AND GMF FUSE INSIDE <br />BOTTOM OF CONCRETE <br />HOLDER J—BOX <br />11 <br />FAN DECK W/EXTENSION <br />COLLAR TO ATTACH <br />SURFACE FIXTURE TO <br />CONCRETE CEILING <br />HANGAR <br />LOW BAY <br />LED <br />(TYPICAL) <br />SURFACE <br />MOUNT <br />FXTURE DETA <br />c <br />SCALE: NONE <br />1 E12 E503 <br />HSS BASE CONNECTION <br />SCALE: NONE <br />BAR CONNECTION <br />SCALE: NONE <br />im <br />E503 <br />E503 <br />�o <br />SEISMIC RESTRAINT <br />FLOODLIGHT LUMINAIRE 10 <br />�— EXISTING STANCHION. <br />VERIFY DIMENSIONS IN <br />FIELD. <br />EXISTING STANCHION <br />MOU TED DETA <br />SCALE: NONE E503 <br />HSS TO HSS CONNECTION <br />SCALE: NONE <br />P <br />PL PER PLAN TACK <br />WELD ` OC <br />HSS PER <br />PLAN <br />31 SIDES <br />TYP <br />CO NECTION <br />SCALE: NONE <br />8 ROUTE MC "WHIP" ALONG <br />LENGTH OF EXISTING ATTIC <br />STRUCTURE TO MAINTAIN CLEAR <br />WORKING SPACE ON ATTIC <br />FLOOR. <br />HSS PER PLAN LOCATE DRIVER NEAR EXISTING <br />RECEPTACLE. DRIVER SHALL BE <br />PROVIDED WITH MOUNTING <br />BRACKETS WITH MINIMUM 2" <br />FROM MOUNTING SURFACE TO <br />BOTTOM OF DRIVER.---—\ <br />17—inP.C`'��i <br />E5 3 SCALE: NONE <br />(E) C1005.3 <br />�x2y2" BAR TYP <br />(E) SHEATHING <br />3' .6,e I I 18 I I <br />9 II II <br />II 91 II <br />HSS 4x4x1/4 HSS 2y2x2Yx5As <br />TYP @ EQ SPG BELOW <br />NOTES: <br />1. INTERIOR SHEATHING NOT SHOWN FOR CLARITY. <br />2. CUT AND RE —PATCH INTERIOR SHEATHING AND <br />INSULATION WHERE (E) C—GIRT IS NOT EXPOSED. <br />DO NOT DAMAGE EXTERIOR SHEATHING. <br />PLAN VIEW <br />9` 1/4" P1723 <br />UNISTRUT L BRACKET <br />LEGEND <br />12 GR 36 PL 1/4 x <br />30" x 30" <br />HIGHBAY LUMINAIRE <br />(PARTIALLY SHOWN) <br />SEE DWG 45-001—E1 FOR LEGEND AND ABBREVIATIONS. <br />STEEL MOUNTING <br />PLATE WITH <br />19" APPROXIMATE <br />DIAMETER <br />----------- <br />---------- <br />CUTOUT FOR LIGHT <br />SOURCE. <br />B <br />GENERAL NOTES <br />1. LUMINAIRE MOUNTING SHALL MEET SEISMIC ZONE (4) AREA <br />#12 SCRE S, SPACING <br />REQUIREMENTS. <br />AS SHOWN. MIN (3) <br />' <br />SCREWS P R EACH <br />2. FOR LUMINAIRE SCHEDULE, <br />SIDE OF PINE. <br />D ; ; <br />3. UNLESS OTHERWISE NOTED ALL CONDUIT IS 3/4" EMT. <br />4. UNLESS OTHERWISE NOTED WIRE IS STRANDED, COPPER TYPE THHN <br />24" SQUARE CEILING <br />�� __ —__ _ _ <br />_ _ _ _ _ _ _ _ _ �' <br />z <br />INSULATION, #12 AWG FOR POWER AND #14 FOR CONTROL. <br />OPENING <br />----- ---- <br />--------- <br />ME <br />5. THE FOLLOWING COLOR CODING OF CONDUCTOR SHALL BE <br />OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. <br />j� I <br />E LA R G E D <br />3/4 " MIN <br />208Y 120V 480Y 277V <br />I �1 <br />ATTIC DECK <br />A � (LEFT BUS IN PNL) BLACK BROWN <br />D <br />LA N <br />PLA <br />/ <br />VIEW <br />E <br />B c (CENTER BUS IN PNL) RED ORANGE <br />I V <br />V V U <br />C � (RIGHT BUS IN PNL) BLUE YELLOW <br />NEUTRAL WHITE GRAY <br />EQUIPMENT GROUND GREEN GREEN <br />ISOLATED GROUND GRN/YEL* GRN/YEL* <br />4 <br />*GREEN WITH YELLOW TRACER <br />6. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS <br />J <br />SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY <br />""" "' °"' 'r) CHANNEL BEYOND <br />__R PLAN <br />HSS 4x4 <br />PER PLAN <br />HSS 4x4xY4 <br />TYP <br />a <br />PL 1/4" 3 —® <br />FIBERGRATE <br />I I.JJ //ZnUZ I — ,,, . <br />PER PLAN TYP PER PLAN <br />FRONT VIEW <br />NEW STRUCTURAL FRAME FOR FLOODLIGHT <br />SCALE: NONE <br />TYP <br />3/16 <br />I- I- I I- 11 1 19 I I 1 1 <br />1/4" CAP PL SEAL <br />WELD ALL AROUND <br />E503 <br />SYM I REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br />RECORDED DRAWING ISSUED TO OWNER A.AS JRB 11 /25/96 <br />A MOVED DOOR DETAIL TO NEW DRAWING E511 NJK 07.27.03 <br />B 45-001 LIGHTING UPGRADES 1786915 CEi PWJ 11.15.19 <br />AT • • <br />FLANGE OF • <br />�'EMOVE EX 16 GA HEADER <br />PLATECOVER <br />SS 4x4 BEYOND <br />_R PLAN <br />7. FOR PANEL SCHEDULES SEE SPECIFICATIONS. <br />PERMANENTLY RECEPTACLES, <br />PANELETC., WITH CIRCUIT <br />DO NOT STEP OR PLACE MATERIAL ON 9. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANEL <br />Ll UPON COMPLETION OF JOB. <br />10. CONDUIT AND WIRING SHALL BE MOUNTED +7' TO 8' ABOVE LOW <br />ATTIC USING STRUT —TYPE CHANNEL FASTENED TO BUILDING <br />STRUCTURAL MEMBERS. <br />11.COORDINATE LOCATION OF ALL LUMINAIRES WITH OTHER BUILDDNG <br />TRADES BEFORE INSTALLATION. <br />1 2 30" x 30" GR 36 STEEL ESCUTCHEON PLATE , 1/4" PLATE <br />A <br />THICKNESS. SECURE WITH #12 SCREWS. VERIFY DIMENSIONS <br />IN <br />NEW PLATE SHALL OVERLAP EXISTING FRAMED STRUCTURE BY <br />IE10,1 1,12,13,1�FIELD, <br />,15 <br />E503 <br />A MINIMUM OF 2". APPROXIMATE 19" DIAMETER CUTOUT FOR LIGHT <br />TRANSMISSION FROM LUMINAIRE. <br />(E) CHANNEL PER PLAN <br />(E) SHEATHING <br />REFERENCE DRAWINGS <br />F <br />BAR BEYOND PER PLAN <br />45-001-1 E10 HANGAR GROUND FLOOR LIGHTING <br />PLAI <br />I <br />E� % <br />2 y 2 2" DIAMETER TENNON <br />45-001-1 E1 1 HANGAR GROUND FLOOR LIGHTING <br />PLAT <br />FOR STANCHION MOUNT <br />45-001-1 E12 HANGAR GROUND FLOOR LIGHTING <br />PLAT <br />SIM <br />OF LIGHT FIXTURE <br />45-001-1 El HANGAR GROUND FLOOR LIGHTING <br />PLAI <br />HSS 4X4 <br />LUMINAIRE <br />45-001-1 E14 HANGAR GROUND FLOOR LIGHTING <br />PLAT <br />PER PLAN <br />�—FLOODLIGHT <br />10 <br />45-001-1 E15 HANGAR GROUND FLOOR LIGHTING <br />PLAT <br />HSS 4X4 PER PLAN <br />LUMINAIRE <br />SEISMIC <br />�— HSS 2 Y X 2 Y PER PLAN <br />DRIVER <br />RESTRAINT <br />CONSTRUCTION NOTES <br />G <br />E503 _— _ _ _ <br />1 EXISTING TWIST LOCK RECEPTACLE. <br />i <br />E503 PL Y" <br />GR 36 PL5/16 X 2'-0" x 3'-0" <br />COVER PLATE <br />HANGAR HIGHBAY OVERHEAD <br />ABANDONED <br />NE 0 <br />DONED FIXTURE LOCATION DETAI 3,(—T� <br />,4,,3 <br />01T� <br />wVSPECIFICATION <br />ACCEPTABILITY <br />ITHIS DESIGN AND/OR <br />IS APPROVED <br />1HECKED <br />■ <br />■ <br />PPROVED BYHECKED <br />®®� <br />B <br />■ <br />®PROVIDE TWIST LOCK RECEPTACLE AND S.O. CORD <br />HSS 2 Y X 2 Yz PER PLAN CONNECTED TO REMOTE DRIVER <br />® <br />EXISTING GLASS LENS. <br />PROVIDE LABEL TO BE INSTALLED AS A STICKER 0 <br />THE ESCUTCHEON PLATE. SIZE THE LABEL TO BE <br />PLACED ON THE MOUNTING PLATE OR ADJACENT T( <br />E503 <br />IT ON THE CEILING/ ATTIC FLOOR PANEL. PROVIDE <br />�--� <br />SAMPLE FOR REVIEW. <br />5� <br />INSTALL AND WIRE REMOTE DRIVER AS SHOWN. <br />MC "WHIP" PROVIDED BY FIXTURE MANUFACTURER. <br />i' <br />INSTALL L BRACKETS TO STEEL PLATE. <br />8 <br />PROVIDE CUSTOM FABRICATED COVER OVER SO <br />CORD WHERE IT COULD BE A TRIP HAZARD. <br />[�- ,PROVIDE <br />MOCKUP OF FIXTURE INSTALLATION FOR <br />REVIEW. <br />10 <br />AIM FIXTURES AS DIRECTED BY BOEING. <br />1] <br />PROVIDE NEW J—BOX FOR NEW LUMINAIRES. <br />12 <br />PROVIDE QUICK DISCONNECT AND FUSE INSIDE <br />J—BOX. <br />1� <br />MATCH LIGHT FRAME ELEVATION TO NEAREST <br />EXISTING LIGHT FRAME. <br />CURRENT REVISION SYMBOL DATE <br />1786915 B 11.15.19 <br />SHEET <br />E503 <br />JOB NO. COMP NO. <br />EVERETT, WA DWI 10. 45-001—E503 <br />+�31�l�l�t41� <br />