My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2020 BLDG 45-01 Plans 2022-12-06
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-01
>
Plans
>
3003 W CASINO RD 2020 BLDG 45-01 Plans 2022-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2022 3:29:39 PM
Creation date
7/21/2022 11:14:24 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-01
Permit
B2007-037
Year
2020
Notes
EX & POUR NEW SHALLOW CONCRETE TRENCH W/ PRECAST CONCRETE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
40" <br />MCC 1 <br />EQUIP <br />NO <br />CKT <br />NO <br />NAME PLATE DATA <br />MOTOR <br />CKT BKR OR HMCP <br />MOTOR STARTER <br />CONT <br />DIAL <br />HP <br />FLA <br />SF <br />AMP <br />RATING <br />SETTING <br />POLE <br />TYPE <br />TYPE <br />SIZE <br />COIL <br />OL HEATER <br />AUX CONTACT <br />CONTROL STATION <br />TYPE # <br />RATING <br />N.O. <br />N.C. <br />Al <br />SPARE <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />START -STOP PUSHBUTTON <br />j <br />A2 <br />SPARE <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />START -STOP PUSHBUTTON <br />A3 <br />SPARE <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />START -STOP PUSHBUTTON <br />A4 <br />INCOMING POWER <br />EF-1 <br />B1 <br />EXHAUST FAN #1 <br />75 <br />175 <br />3 <br />HJD <br />VFD-1 <br />E516 <br />EF-2 <br />B2 <br />EXHAUST FAN ' 2 <br />75 <br />175 <br />3 <br />HJD <br />VFD-2 <br />E516 j <br />B3 <br />SPARE <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />j <br />EF-3 <br />84 <br />EXHAUST FAN #3 <br />75 <br />175 <br />3 <br />HJD <br />VFD-3 <br />E517 <br />EF-4 <br />B5 <br />EXHAUST FAN #4 <br />75 <br />175 <br />3 <br />HJD <br />VFD-4 <br />E517 <br />B5 <br />SPARE <br />l00 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />j <br />SYM <br />REVISION <br />RECORD DRAWING ISSUED TO OWNER <br />A <br />REMOVE CLARIFIER &c WASH PUMPS <br />B <br />REMOVE CONDENSATE PUMPS <br />C <br />CONDENSATE CONTROL UNIT REPLACEMENT <br />D <br />MODIFIED CONDENSATE CONTROL SYSTEM <br />BY APPROVED <br />DATE <br />SYM <br />I REVISION <br />AAS JRB <br />11.25.96 <br />E <br />AS -BUILT CONDENSATE PROJECT <br />J, MACK T. MAST <br />05.14.04 <br />F <br />PEN REPLACE EXHUAST FANS <br />1001040430 <br />AFM BDC/BAO <br />05.14.04 <br />G <br />SITE PUMPED INDUSTRIAL WASTE <br />1001040430 <br />AKC PRH/BAO <br />8/9/04 <br />NJK KR/WL <br />11.02.05 <br />MCC <br />2 <br />EXISTING <br />NEW <br />A <br />B <br />C <br />D <br />E <br />CONDENSATE <br />CONTROLER <br />INCOMING <br />PUMP P1 <br />POWER <br />Cl <br />SPARE-1 <br />SPARE SPARE <br />Al <br />Bl B2 <br />CONDENSATE <br />E1 <br />PUMP P2 <br />C2 <br />EF-17 <br />EF-18 <br />7.5 HP <br />7,5 HP <br />CONDENSATE <br />HP-1 <br />SIZE 1 ' <br />SIZE 1 <br />SPARE <br />SPARE-7 <br />PUMP P3 <br />125 HP <br />A2 <br />B3 <br />C3 <br />E2 <br />E3 <br />EF-19 <br />7.5 HP <br />P E 4 <br />SIZE l E4 <br />SPARE-6 <br />SPARE-10 <br />A3 <br />B <br />XFP <br />EF-20 <br />TRANSFER <br />2 <br />7.5 HP <br />INCOMING <br />PUMP P15 C5 <br />SIZE 1 E5 <br />POWER <br />XFP <br />SPARE-12 <br />TRANSFER <br />l <br />A4 <br />B <br />PUMP P14 <br />• C6 <br />D"I <br />SPACE E6 <br />G <br />105" <br />EQUIP CKT NAME PLATE DATA <br />NO N0 <br />Al <br />SPARE-1 <br />A2 <br />SPARE <br />A3 <br />SPARE-6 <br />A4 <br />INCOMING POWER ABANDONED <br />B1 <br />SPARE <br />B2 <br />SPARE <br />B3 <br />SPARE-7 <br />B4 <br />SPARE-10 <br />B5 <br />SPARE-12 <br />P1 <br />C1 <br />CONDENSATE PUMP CONTROLER & P1 <br />P2 <br />C2 <br />CONDENSATE PUMP P2 <br />P3 <br />C3 <br />CONDENSATE PUMP P3 <br />4 <br />XFP <br />C5 <br />PIW TRANSFER PUMP 45-06 P15 <br />XFP <br />C6 <br />PIW TRANSFER PUMP 45-06 P14 <br />HP-1 <br />D1 <br />HYDRAULIC PUMP <br />E1 <br />INCOMING POWER <br />EF-17 <br />E2 <br />EXHAUST FAN EF-17 <br />EF-18 <br />E3 <br />EXHAUST FAN EF-18 <br />EF-19 <br />E4 <br />EXHAUST FAN EF-19 <br />EF-20 <br />E5 <br />EXHAUST FAN EF-20 <br />E6 <br />SPACE <br />ACCEPTABILITY <br />THIS DESIGN AND/OR <br />SPECIFICATION IS APPROVED <br />*UROVED BY I DEPT. I DATE <br />MCC 2 <br />MOTOR <br />CKT BKR OR HMCP <br />MOTOR STARTER <br />HP <br />FLA <br />SF <br />AMP <br />RATING <br />SETTING <br />POLE <br />TYPE <br />TYPE <br />SIZE <br />COIL <br />OL HEATER <br />AUX CONTACT <br />CONTROL STATION <br />TYPE # <br />RATING <br />N.O. <br />IN.C. <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL, SW. <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL, SW. <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL, SW. <br />50 <br />3 <br />HMCP <br />FVNR <br />2 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />50 <br />3 <br />HMCP <br />FVNR <br />2 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />100 <br />3 <br />HMCP <br />FVNR <br />3 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />10 <br />11.6 <br />II J 5 <br />30 <br />3 <br />HMCP <br />FVNR <br />2 <br />W55 <br />14.1A <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />10 <br />11.6 <br />1.15 <br />30 <br />3 <br />HMCP <br />FVNR <br />2 <br />W55 <br />14.1 A <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />10 <br />11.61 <br />1.15 <br />30 <br />3 <br />HMCP <br />FVNR <br />2 <br />W55 <br />14.1A <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />- U <br />20 <br />27 <br />50 <br />3 <br />CB <br />FVNR <br />2 <br />ELEC <br />29.7 <br />2 <br />2 <br />START -STOP PUSHBUTTON <br />20 <br />27 <br />50 <br />3 <br />CB <br />FVNR <br />2 <br />ELEC <br />29.7 <br />2 <br />2 <br />START -STOP PUSHBUTTON <br />125 <br />156 <br />250 <br />3 <br />1 HMCP <br />SMC <br />1180A <br />120 <br />1 2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />7.5 <br />11 <br />20 <br />3 <br />HMCP <br />FVNR <br />1 <br />120 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />7.5 <br />11 <br />20 <br />3 <br />HMCP <br />FVNR <br />1 <br />120 <br />2 <br />2 <br />NAND -OFF -AUTO SEL. SW. <br />7.5 <br />11 <br />20 <br />3 <br />HMCP <br />FVNR <br />1 <br />120 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />7.5 <br />11 <br />20 <br />3 <br />HMCP <br />FVNR <br />1 <br />120 <br />2 <br />2 <br />HAND -OFF -AUTO SEL. SW. <br />CONT <br />B IAG <br />CONSTRUCTION NOTES <br />DISCONNECT AND CLEAN WIRE ENDS AND TERMINALS <br />IN EXISTING P14 MCC BUCKET. RE -TERMINATE WIRES <br />G <br />TO AB RECOMMENDED TORQUE LEVELS. REPLACE <br />OVERLOADS WITH ALLEN-BRADLEY E-300 SERIES <br />ELECTRONIC OVERLOAD. <br />2� PROVIDE AND INSTALL SIZE 2 COMBINATION STARTER <br />BUCKET FOR P15 XFER PUMP WHERE SHOWN. SEE <br />WIRING DETAIL ON SHEET E501-2. <br />ISSUE FOR CONSTRUCTION <br />MARCH 20, <br />2020 <br />.3545 EACTORIA BOULEVARD SE., SUITE 200 <br />BELLEVUE IAA 98006 <br />(425) 522-1000 WWW.CASNE.COM JOB NO, 191-171 <br />AXE <br />08. 1&95 <br />SUBTITLE MOTOR CONTROL CENTER <br />CURRENT <br />SYMBOL G <br />DATE <br />0808 <br />03.20.20 <br />MCC-1 <br />SHEET <br />TITLE SITE PUMPED INDUSTRIAL WASTE <br />E501 <br />BUILDING( <br />JOB NO. <br />COMP No. <br />00027227 <br />ELECTRICAL MASTER <br />EVERETT, WA <br />DWG NO. 45-001-E501 <br />
The URL can be used to link to this page
Your browser does not support the video tag.