®� PANEL/CKT <br />3/4 C GRS - 2 12,3#12G <br />F45-01— <br />MISC. PLC 1 <br />I <br />I <br />INPUT BLUEa TB-R1-1 <br />12 I 1_000211 WHT TB-R1-2 <br />PNEUMERCATOR <br />I FAULT/TROUBLE <br />I <br />INPUT <br />EF BLUE <br />I <br />TB-R2-1 <br />I_000212 <br />WHT TB-R2-2 <br />LEAK DETECTED <br />AB-S 1 <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />3 <br />I <br />4 <br />I <br />I <br />I <br />i <br />I <br />I <br />O <br />® <br />I <br />Ld <br />I <br />I <br />Lo <br />r <br />I INPUT <br />BLUHRTB-R3-1 <br />W <br />I_000213 LEAK <br />WHT RTB-R3-2 <br />I DETECTED <br />SHD <br />0 <br />I AB-S2 <br />BLURTB-R4-1 <br />SPARE ALARM <br />WHT RTB-R4-2 <br />SHD <br />a <br />BLURTB-R5-1 <br />a <br />SPARE ALARM <br />W <br />El <br />RTB-R5-2 <br />®SHD <br />I <br />BLU <br />RTB-R6-1 <br />SPARE ALARM <br />I <br />WHT I RTB-R6-2 <br />SHD <br />i <br />i <br />i <br />V <br />QD <br />0 <br />- <br />c <br />9 <br />m <br />7TYP. <br />ffOOLE5�3 <br />�I PNEUMERCATOR LC2000 <br />I LEAK DETECTION PANEL 3 <br />NON -INTRINSICALLY INTRINSICALLY SAFE <br />I SAFE AREA I AREA <br />I <br />I I <br />I POWER I <br />I I <br />l I <br />I <br />-1 <br />ITEM <br />PARTS LIST <br />QTY <br />NO. <br />PART NUMBER <br />PART NAME <br />DESCRIPTION <br />SH <br />1 <br />1 <br />LC2000-21 -01 -41 -0 <br />LEAK DETECTION <br />MONITORING PANEL <br />PNEUMERCATOR <br />1 <br />2 <br />LS600LDBN-I-F <br />ELECTRICAVFLOAT <br />LEAK SEOR <br />PNEUMERCATOR <br />1 <br />3 <br />P/N 161109-1 <br />THUMB -TURN LATCH <br />NEMA 4X <br />PNEUMERCATOR <br />1 <br />4 <br />ES825-200-F <br />ELECTRICAL OPTICAL <br />LEAK SENSOR <br />PNEUMERCATOR <br />1 <br />5 <br />900463-1 <br />OPTION CARD <br />PNEUMERCATOR <br />DDIff> FIELD DEVICES <br />FNEMA 4 J-BOXES WITH CGB <br />AT SENSOR LOCATION (TYP) <br />GENERAL_ MOTES <br />1. USE GRS CONDUIT AND MYERS HUBS W/ <br />GROUND SCREWS ONLY OUTSIDE OF BUILDING. <br />2. USE ONLY APPROVED KNOCK OUTS ON THE <br />BOTTOM OF PNEUMERCATOR PANEL. <br />3. INSTALL LABELS ON ALL MIRES AT ALL <br />TERMINATION POINTS. LABELS TO BE HEAT <br />SHRINK TYPE. <br />2I ALL FIELD WIRING SHALL BE 3 CONDUCTOR, <br />SHIELDED, 18AWG, WITH PVC JACKET UNLESS <br />OTHERWISE NOTED (BELDEN 8770 OR <br />EQUIVALENT), USE THE BLACK AND RED <br />CONDUCTORS OF CABLE SAFE -OFF 3RD <br />CONDUCTOR (WHITE) IF NOT NEEDED AT BOTH <br />ENDS. <br />5. CABLE SHIELDS SHOULD BE TERMINATED AS <br />SHOWN. WHERE TERMINATION IS NOT SHOWN <br />LEAVE BOTH ENDS DISCONNECTED. <br />6, FIELD WIRING SHALL BE CONTINUOUS WITH NO <br />SPLICING UNLESS APPROVED BY DESIGN <br />ENGINEER. <br />7. ALL INTRINSICALLY SAFE WIRE AND CONDUIT <br />MUST BE LABELED AS SUCH. <br />8, INSTALL VAPOR SEALOFFS AS REQUIRED LEAVING <br />AND ENTERING CLASSIFIED AREAS PER NEC <br />ARTICLE 504. <br />BUILT-IN RELAY I 0 29.5'IU 5. — . U `"" � rirt uruu 1101itNC)1111HL Jra�Lt REFERENCE DRAWINGS/ 30 -Q® fi. Bm STB-6 STB-3 -Sz AB-S2 UTILIDOR VAULT S10 <br />I (RTB) I <br />45-001-1 E64 120V PARTIAL POWER PLAN <br />RTB-R1-1 BLUE 0. 31, +V 7. +V <br />N.RTB-R1-2 WHT I 32. Si 1 s. S3 I 1 fl 45-001-1 E214 PARTIAL FIRST FLOOR EMCS PLAN <br />I 0M c. 1 33 �- <br />1 .C. I 34 +v 30 F�/ I 11 45-001-E533 LEAK DETECTION AND DETAILS <br />RTB-R2-1 BLUE OM 35 S 12 11. S 12 45-001-E701-013 BUILDING PANEL WIRING DIAGRAM <br />RTB-R2-2 WHT N.C. N I 30 -- 12. <br />I 1 37 +V 13. +V 13 45-001-1 E212A PARTIAL FIRST FLOOR EMCS PLAN <br />39 S 13 14. S5 I 14 45-YD-E210-04 PARTIAL YARD PLAN <br />I n 1 41s 14 1s. s6 I <br />CONSTRUCTION NOTES <br />I I 42 113 I PROVIDE AND INSTALL PNEUMERCATOR PANEL WITH <br />CC 1"i I 43 +v 19. +U I OPTION CARD. <br />44,S150 20 S 7 <br />EI L(`2 cf) I 45 ""� 21 `� I INSTALL FLOAT TYPE LEAK SENSOR, PROVIDE <br />PHENOLIC TAG FOR EACH LEAK SENSOR WITH <br />I m 1 4s. +V 22 +°t� I LEAK SENSOR NAME. CHAIN TAG TO LEAK SENSOR <br />47516023 S8 0I CABLE. SEE REF. DRAWINGS. <br />cai 48 ` 24. --� <br />3 PROVIDE AND INSTALL CONDUCTORS AND CONDUIT <br />(RE -USE AS -BUILT CONDUIT IF EXISTING) TO <br />10 CONNECT PNEUMERCATOR PANEL TO LEAK <br />SENSORS. <br />®INSTALL CONDUIT AND WIRING TO COMPLETE <br />CIRCUIT FROM PANEL, PULL TWO ADDITIONAL <br />I PNEUMERCATOR 900463-1 ® 5 INTRINSICALLY SAFE GROUNDS AS REQUIRED. <br />I OPTION CARD 1 � <br />L%-�'" PROVIDE AND INSTALL PAIRS OF 14 THHN, BLUE <br />AND WHITE WITH BLUE TRACER, BETWEEN <br />RTB-R3-1 � BLUE — — — — — � — � — — — � PNEUMERCATOR PANEL AND MISC. BUILDING PLC. <br />RTB-R3-2 WHT COM I CC1 I 6. BOEING ENGINEER WILL PROGRAM PANEL. <br />1 N.C.I CC2 I CONTRACTOR WILL PROVIDE STARTUP AND TESTING <br />SUPPORT. ELECTRICIANS NEED TO COORDINATE <br />N.O. <br />RTB-R4-1 BLUE I INSTALLATION WITH MATT KENT 425-29-4719. <br />I <br />RTB-R4-2 WHT COM � I CC3 I <br />N <br />RTB-R5-1 I BLUE N.C. I I I <br />RTB-R5-21 WHT N.O. CCU <br />COM I o� <br />I I I <br />RTB-R6-1 BLUE N.C. <br />RTB-R6-2 WHT N.O. I I <br />COM <br />I N.C. i <br />L_ <br />LOG; 45-01 <br />mou <br />