GENERAL NOTES <br />1. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY <br />REQUIRED DIMENSIONS NOT SHOWN ON DRAWINGS. DRAWINGS <br />HAVE BEEN PREPARED ON AN ORIGINAL SHEET SIZE OF 24" x 36'. <br />2. PLAN DIMENSIONS SHOWN INDICATE FACE OF EXISTING WALL OR <br />COLUMN, FACE OF CONCRETE, FACE OF GYPSUM WALLBOARD, OR <br />CENTERLINE OF GRID. VERTICAL DIMENSIONS ARE FROM FACE OF <br />STRUCTURAL FLOOR. <br />3. INFORMATION REGARDING EXISTING CONDITIONS USED TO <br />PREPARE THESE DRAWINGS HAS BEEN PROVIDED BY OTHERS. <br />CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO <br />COMMENCING CONSTRUCTION. PROVIDE WRITTEN NOTIFICATION <br />TO THE ARCHITECT OF ANY DISCREPANCIES BETWEEN EXISTING <br />CONDITIONS AND THE DRAWINGS. ARCHITECT WILL ISSUE A <br />WRITTEN DIRECTIVE IF FURTHER CLARIFICATION IS REQUIRED. <br />4. PROVIDE BLOCKING BETWEEN WALL STUDS WHEREVER MILLWORK, <br />CASEWORK, OR EQUIPMENT IS MOUNTED TO WALL. <br />5. THESE DRAWINGS ARE THE EXCLUSIVE PROPERTY OF HAYNES <br />WILSON LUND ARCHITECTS, LLC AND HAVE BEEN PREPARED FOR <br />USE IN THE EXECUTION OF THE PROJECT DESCRIBED HEREIN. USE <br />OR REPRODUCTION FOR ANY OTHER PURPOSE WITHOUT THE <br />WRITTEN PERMISSION OF HAYNES WILSON LUND ARCHITECTS, LLC <br />IS PROHIBITED. <br />♦ �' �' W It <br />AT HS HOSE BIBB QT QUARRYTILE <br />CENTERLINE HOR HEADERHDHEAD <br />0 POUND or NUMBER HDBD HARDBOARD <br />HDWD HARDWOOD RAD RADIUS <br />ACC ACCESSIBLE HDWR HARDWARE RB RESILIENT BASE <br />ACOUS ACOUSTICAL RD ROOF DRAIN <br />ACT ACOUSTICAL TILE HM HOLLOW METAL <br />ADJ ADJUSTABLE HORIZ HORIZONTAL RT RESILIENT TILE <br />AFF ABOVE FINISH FLOOR HR HOUR REFL REFLECTED <br />AL ALUMINUM HT HEIGHT REINF REINFORCED(ING) <br />ARCH ARCHITECT HTG HEATING. REQD REQUIRED <br />AN AUDIOIVISUAL <br />RM ROOM <br />SO BOARD ID INSIDE DIAMETER RO ROUGH OPENING <br />STWN BETWEEN INCL INCLUDING RVR REVERSE(D) <br />BLDG BUILDING INSUL INSULATION <br />BLK BLOCK INT INTERIOR Sc SOLID CORE <br />BLKG BLOCKING <br />BM BEAM JAN JANITOR SCHED SCHEDULE <br />SOT BOTTOM SECT SECTION <br />BRG. BEARING JT JOINT SF SQUARE FEET <br />CAB CABINET KIT KITCHEN SH SHELF <br />CER CERAMIC KD KNOCKED DOWN BHT SHEET <br />CG CORNER GUARD SIM SIMILAR <br />CLG CEILING KO KNOCK -OUT <br />CLR CLEARANCE) <br />KPL KICK PLATE so SQUARE <br />CMU CONCRETE MASONRY UNIT SST STAINLESS STEEL <br />COL COLUMN LAM LAMINATE(D) STD STANDARD <br />CONT CONTINUOUS STL STEEL <br />CPT CARPET LAV LAVATORY <br />LTL LINTEL STOR STORAGE <br />DBL DOUBLE LVR LOUVER SUSP SUSPENDED <br />DEMO DEMOLITION <br />DET DETAIL MAS MASONRY T&G TONGUE & GROOVE <br />DIAG DIAGONAL MATL MATERIAL <br />pIAM DIAMETER TELE TELEPHONE <br />ON DOWN MAX MAXIMUM TEMP TEMPORARY <br />DR DOOR MECH MECHANICAL THK THICKNESS) <br />DWG DRAWING MED MEDIUM THR THRESHOLD <br />MEMB MEMBRANE <br />EA EACH MET METAL TYP TYPICAL <br />EJT EXPANSION JOINT MFR MANUFACTURER <br />EL ELEVATION MIN MINIMUM UNFIN UNFINISHED <br />ELVR ELEVATOR <br />ENCL ENCLOSURE MISC MISCELLANEOUS LINO UNLESS NOTED OTHERWISE <br />EQ EQUAL MTD MOUNTED <br />EQUIP EQUIPMENT MULL MULLION VCT VINYL COMPOSITION TILE <br />EXH EXHAUST VEN VENEER <br />EXIST EXSTINGSTING <br />EXP EXPANSION NIC NOT IN CONTRACT VERT VERTICAL <br />EXT EXTERIOR NO NUMBER VIF VERIFY IN FIELD <br />NOM NOMINAL VWC VINYL WALLCOVERING <br />FE FREEIXTNGUISHER NTS NOT TO SCALE <br />FEC FIRE EXTINGUISHER CABINET <br />FFE FINISHED FLOOR ELEVATION w1 WITH <br />FIN FINISH(NG) OC ON CENTER WC WATER CLOSET <br />OD OUTSIDE DIAMETER <br />FLG FLASHING WD WOOD <br />FLR FLOOR OH OVERHEAD <br />Wl0 WITHOUT <br />FLUOR FLUORESCENT OPNG OPENING <br />FT FOOT, FEET OPP OPPOSITE WSCT WAINSCOT <br />FTG FOOTING Wi WEIGHT <br />GA GAGE,GAUGE PBD PARTICLE BOARD WWF WELDED WIRE FABRIC <br />GALV GALVANIZED PC PRECAST CONCRETE <br />GEN GENERAL PERF PERFORATE(D) <br />GFRC GLASS FIBER REINF CONCRETE PL PLATE <br />GL GLASS, GLAZING GLB GLULAM BEAM p( qM PLASTIC LAMINATE <br />GR GRADE, GRADING PLAS PLASTER <br />GWB GYPSUM WALLBOARD PLWD PLYWOOD <br />GYP GYPSUM PNL PANEL <br />PR PAIR <br />PT PRESSURE TREATED <br />PTN PARTITION <br />SYMBOL LIST. <br />Roo®nnE ROOM IDENTIFIER w/ NAME & NUMBER <br />_0 DOOR IDENTIFIER <br />9PARTITION TYPE INDICATOR <br />�'i X _ DETAIL INDICATORS <br />X X = DETAIL NUMBER; Y = SHEET NUMBER <br />X EXTERIOR ELEVATION INDICATOR <br />Y X = DETAIL NUMBER; Y = SHEET NUMBER <br />4YNINTERIOR ELEVATION INDICATOR <br />X = DETAIL NUMBER; Y = SHEET NUMBER <br />aWINDOW FRAME TYPE INDICATOR <br />ACCESSIBILITY CLEARANCE INDICATORS <br />(60" CIRCLE) <br />TENANT IMPROVEMENT FOR <br />RESTECH <br />304 SE EVERETT MALL WAY <br />EVERETT, WA 98208 <br />DESCRIPTION of PROJECT <br />The Work of this project consists of interior tenant improvements to <br />remove some existing walls to create a contiguous work area for a new <br />tenant in an existing suite. There will be some structural work as a result <br />of removing the walls. <br />The tenant's business involves the application of resin finishes to motor <br />vehicles. A large portion of the Work Room space will be occupied by the <br />subject vehicles so that the actual number of people working in the space <br />will be significantly less than what would be determined by standard <br />occupant load factors. <br />Additional Permits Are Required <br />For This Project To Include: <br />APPLICABLE CODES <br />C] Plumbing Sprinkler <br />Everett Municipal Code ❑ Mechanical Fire Alarm <br />❑ Electrical <br />2018 International Building Code <br />2018 International Mechanical Code Chapter 51-52 WAC <br />2018 International Fire Code — Chapter 51-54A WAC <br />2018 Uniform Plumbing Code — Chapters 51-56 and 51-57 WAC <br />2018 International Energy Conservation Code & Washington State errata <br />WAC 51-11R & 51-11C <br />ICC/ANSI A117.1-2009: Accessible and Usable Buildings & Facilities <br />All as adopted and amended by Washington State & the City of Seattle <br />DRAWING LIST <br />A00 PROJECT DATA, GENERAL NOTES, VICINITY PLAN <br />A20 FLOOR PLANS, LIFE SAFETY INFORMATION <br />SITE DIAGRAM <br />NO SCALE <br />P ROJ ECT TEAS <br />APPROVED <br />Office of Community, <br />Planning & Economic Development <br />PLANNING DEPARTMENT ram, <br />Owner: 3H LLC/ Everett Auto Mall DATE:(�..._..� <br />7515 SE 71st Street NAME. <br />Mercer Island, WA 98040 <br />contact: Kwai Hsue 206-369-6550 <br />Tenant: Restech ° F� <br />318 SE Everett Mall WaySuite 101 <br />SEP 2 8 2021 <br />Everett, WA 98208 <br />contact: Alex Montoya 425-319yPA6clarvir.e,*, <br />Architect: <br />Contractor: <br />��EIVE <br />APR 2 9 2021 <br />CITY OF EVERETT <br />Permit Services <br />rnNCI IITANT NAME / r nm(zi nTAKIT 1 nr-n <br />Permit #: B2101-053 <br />Site Address: 318 SE EVERETT MALL WAY <br />Owner: 3-H LLC <br />Tenant: ALEX MONTOYA <br />App. Date: 1/30/2021 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Description: REMOVE LOAD BEARING WALLS, INSTL <br />SUPPORT BEAMS FOR 2ND STORY <br />Reviewed By: Date: <br />Office Set Job Site Set Fire/Planning Set <br />THESE DOCUMENTS HAVE NOT BEEN APPROVED FOR THE ISSUANCE OF PROJECT TITLE /PROJECT ADDRESS <br />TY OF bmRay PUBLIC WORKS, MECHANICAL, FIRE <br />SUPPRESSION, EL CTRICAL OR <br />RFilIFInIFn Pm pMRAifi PLuMIBING PERMIT, /A-\ 0 Tenant Improvement <br />F <br />Jut.1 o ���t for L <br />lJ <br />SITE & BUILDING DATA <br />CITY OF EVERETT <br />Permit Services ADDRESS: Suite 101 RESTECH <br />304 SE Everett Mall Way <br />Everett, WA 98208 <br />Haynes Wilson Lund Architects, LLC <br />385.101st Avenue SE <br />Bellevue, WA 98004 <br />contact: Haynes Lund 425-643-3921 <br />Work to be done by Tenant <br />PARCEL NUMBER: 28051800303900 <br />LEGAL DESCRIPTION: Section 18 Township 28 Range 05 Quarter SW - SEGD FOR <br />TAX PURPOSES ONLY - LOT 2 OF BSP REC AFN 8809165002 BEING PTN OF SW1/4 SW1/4 - EXC <br />4200 SQ FT PANERA BREAD BLDG ON PARCEL 28051800303901 <br />LOT AREA: 3.75 Acres <br />ZONING: BUSINESS (B) <br />BUILDING AREA: 42,160 Sq Ft <br />BUILDING HEIGHT: 1 story <br />CURRENT USE: AUTO SERVICE CENTER <br />PROPOSED USE: AUTO SERVICE CENTER (no change) <br />CONSTRUCTION TYPE: V-B <br />FIRE PROTECTION: NOWSPRINKLERED <br />PROJECT SITE <br />Suite 101 <br />304 SE Everett Mall Way <br />Everett, WA, 98208 <br />REVISIONS <br />PERMIT DOCUMENTS O4-19-2021 <br />BID DOCUMENTS <br />CONSTRUCTION DOCUMENTS <br />PROJECT NUMBER <br />DRAWN BY HL <br />CHECKED BY HWL <br />DATE 19 APR 2021 <br />ARCHITECT / ENGINEER SEAL <br />820 <br />REGISTERED <br />ARCHITECT , <br />HAYNESLUND <br />S T A^R OF WASHTNGTON <br />SHEET TITLE <br />P ROJ ECT TITLE <br />GENERAL NOTES <br />VICINITY PLAN <br />SHEET NUMBER <br />M01 <br />0 2021 Haynes Wilson Lund Architects, III <br />