Laserfiche WebLink
I <br /> City of Everett 01 30 00- 9 <br /> Inductive Charging Infrastructure for Everett Transit <br /> A. Modify manufacturers' standard catalog cuts, brochures, diagrams, schedules, <br /> performance charts, illustrations, calculations, drawings, printed installation, <br /> erection, application, placing instructions, and other descriptive data to delete <br /> information that is not applicable to the Contract. Supplement standard <br /> information with additional information indicating dimensions, clearances, <br /> performance characteristics, capacities, wiring and piping diagrams, controls, etc. <br /> applicable to this Contract. <br /> IB. Submit (and as necessary modify) manufacturers' printed instructions for <br /> delivery, storage, assembly, installation, placing, start-up, adjusting, and finishing <br /> to delete information that is not applicable to the Contract. <br /> C. Certificates of compliance shall be submitted for those products for which no <br /> samples and test results are specified. Copy of certificate shall also accompany <br /> the product for which the certificate is prepared. The certificates shall: <br /> 1. State that the product complies with the respective Specification and Plan <br /> requirements. <br /> 2. Be accompanied by a certified copy of test results pertaining to the <br /> product. <br /> 3. Show the submittal date, Contractor's name and address, Contract title <br /> and number, product represented and its location in the Contract, <br /> manufacturer's name, product trade and catalog number, place of product <br /> origin, test date, testing organization's name and address, quantity of the <br /> product to be furnished, and related Drawing and Specification section <br /> number. <br /> 4. Be signed by an officer or other authorized representative of the <br /> manufacturer and be notarized. <br /> 5. Be received by the Construction Manager not later than 30 days before <br /> the products are to be installed. <br /> 3.6 WORKING DRAWINGS <br /> A. Submit Working Drawings and associated calculations for temporary Work that <br /> will not become a part of the permanent structures included in this Contract. Use <br /> a working drawing sheet with a maximum size of 22 inches by 34 inches. Identify <br /> working drawings by a control number and by reference to Plan numbers and/or <br /> Specification Section numbers, as applicable. Working drawings shall show <br /> information as required herein and in the individual Specification sections. <br /> B. Submittal of the Working drawings shall include, associated calculations, <br /> dimensions, identification of specific products and materials, product data and <br /> 01 30 00 - 9 SUBMITTALS <br />