Laserfiche WebLink
BeamChek v2016 licensed to:Plan One Reg#9077-2060 <br /> 5501 Sound Drive South Overhang <br /> Reference Beam Date:4/08/19 <br /> Selection 4x 10 DF-L#2 Lu=0.0 Ft <br /> Conditions NDS 2012 <br /> Min Bearing Area R1=1.4 in2 R2=1.4 in2 (1.5)DL Defl= 0.19 in <br /> Data Beam Span 14.0 ft Reaction 1 LL 525# Reaction 2 LL 525# <br /> Beam Wt per ft 7.87# Reaction 1 TL 895# Reaction 2 TL 895# <br /> Bm Wt Included 110# Maximum V 895# <br /> Max Moment 3133'# Max V(Reduced) 797# <br /> TL Max Defl L/240 TL Actual Defl L/466 <br /> LL Max Defl L/360 LL Actual Defl L/959 <br /> Attributes Section(in3) Shear(in2) TL Defl(in) LL Defl <br /> Actual 49.91 32.38 0.36 0.18 <br /> Critical 30.27 5.77 0.70 0.47 <br /> Status OK OK OK OK <br /> Ratio 61% 18% 52% 38% <br /> Fb(psi) Fv(psi) E(psi x mil) Fc±(psi) <br /> Values Reference Values 900 180 1.6 625 <br /> Adjusted Values 1242 207 1.6 625 <br /> Adjustments CF Size Factor 1.200 <br /> Cd Duration 1.15 1.15 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> CI Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:75 Uniform TL: 120 =A <br /> Uniform Load A <br /> 0 0 <br /> R1 =895 R2=895 <br /> SPAN=14 FT <br /> Uniform and partial uniform loads are lbs per lineal ft. <br />