t <br /> BeamChek v2016 licensed to:Plan One Reg#9077-2060 <br /> 5501 Sound Drive Master Bathroom <br /> Fixed Shower Window Date:4/08/19 <br /> Selection 4x 8 DF-L#2 Lu=0.0 Ft <br /> Conditions NDS 2012 <br /> Min Bearing Area R1=2.0 in2 R2=2.0 in2 (1.5)DL Defl= 0.08 in <br /> Data Beam Span 7.5 ft Reaction 1 LL 750# Reaction 2 LL 750# <br /> Beam Wt per ft 6.17# Reaction 1 TL 1223# Reaction 2 TL 1223# <br /> Bm Wt Included 46# Maximum V 1223# <br /> Max Moment 2293'# Max V(Reduced) 1026# <br /> TL Max Defl L/240 TL Actual Defl L/579 <br /> LL Max Defl L/360 LL Actual Defl L/>1000 <br /> Attributes Section(ins) Shear(in2) TL Defl(in) LL Defl <br /> Actual 30.66 25.38 0.16 0.08 <br /> Critical 20.45 7.44 0.38 0.25 <br /> Status OK OK OK OK <br /> Ratio 67% 29% 41% 32% <br /> Fb(psi) Fv(psi) E(psi x mil) Fc i(psi) <br /> Values Reference Values 900 180 1.6 625 <br /> Adjusted Values 1346 207 1.6 625 <br /> Adjustments CF Size Factor 1.300 <br /> Cd Duration 1.15 1.15 <br /> Cr Repetitive 1.00 <br /> Ch Shear Stress N/A <br /> Cm Wet Use 1.00 1.00 1.00 1.00 <br /> CI Stability 1.0000 Rb=0.00 Le=0.00 Ft <br /> Loads Uniform LL:200 Uniform TL: 320 =A <br /> Uniform Load A <br /> 0 0 <br /> R1 =1223 R2=1223 <br /> SPAN=7.5 FT <br /> Uniform and partial uniform loads are lbs per lineal ft. <br />