Laserfiche WebLink
Ap <br /> 1 1/4"DIA.MIN. A. <br /> CONT.HANDRAIL NOTE: SPACING BETWEEN INTERMEDIATE GUARDRAIL — <br /> F MEMBERS TO BE A MAXIMUM OF 4'CLEAR: SUCH THAT J. <br /> x BETWEEN WALL A SPHERE OF 4'DIAMETER SHALL NOT PASS THROUGH <br /> f AND HANDRAIL ANY OPENING. n-. a n <br /> • ',`m RETURN BALLUSTERS TO CONFORM O N <br /> ,N. EWELAPOSTIL O -- -- TO IRC R312 toe <br /> N <br /> Z�OR WAI1L- W <br /> __.__—_,: Q (orb <br /> I A 34 FRAMING , f 3 Q . <br /> ANCHOR 4 --- /m <br /> u, <br /> r ` W <br /> �. t Y 7f <br /> co L <br /> z � V « <br /> to MIN y (/�(l 9 N co <br /> TREAD \ (j \ _.... (3)2X12 STRINGERS DI N W <br /> • N <br /> n il \ 1/2"GYPSUM BOARD(MIN) , Q W <br /> el• <br /> \ I SEE ADDTIONAL NOTES AT 5.1 ( I. co 01 <br /> a a <br /> , CID <br /> - ---\2X4 THRUST BLOCK U. <br /> ADDITIONAL DRAWINGS NOTES 7.--- aT NOT TO SCALE i , <br /> Al. 303.4.1.3 Fan Controls: The whole house ventilation fan shall be controlled by a _1� Y;p, INTERIOR STAIR <br /> 24-hour clock timer with the capability of continuous operation, manual and automatic <br /> control. The - our timer shalt be readily accessible. The 24-hour timer shall be capable <br /> of operating the whole house ventilotion fan without energizing other energy-consuming Caution:Adjustments to riser height may be required if <br /> appliances. At the time of final inspection, the automatic control timer shall be set to using the laminate wood flooring with pre-manufactured - . x� F <br /> operate the whole house fan for at least 8 hours a day. A label shall be affixed to the nosings. ▪ - . ,,. <br /> control that mods 'Whole House Ventilation (see operating instructions)." <br /> T <br /> '5034.15 Outdo, A• Inlets: Outdoor air shall be distributed to each habitable room by 8 \ Y <br /> individual outdoor air nlets. Where outdoor air supplies are separated from exhaust points B ▪ ` k <br /> by doors, provisions shall be mode to ensure air flow by installation of distribution ducts, <br /> undercutting doors, installation of grilles, transoms, or similar means where permitted by • as ,4 <br /> < the international Building Code. Doors shall be undercut to a minimum of 1/2- Inch _ <br /> above the surface of the finish floor covering. -_-_ _ <br /> Individual room outdoor air inlets shall: <br /> a. Have controllable and secure openings; - _ <br /> b. Be sleeved or otherwise designed so as not to compromise the thermal properties of <br /> the wall or window in which they ore placed; <br /> c. Provide not less than 4 square inches of net free area of opening for each habitable _.__. __.. .......... ....... _____ ._..... <br /> space, Any inlet or combination of inlets which provide 10 cfm at 10 Pascals as <br /> determined by the Home Ventilating Institute Air Flow Test Standard (HVI 901 [November �' I <br /> 1996] ) are deemed equivalent to 4 square inches net free area. MAIN EXISTING STREET ENTRANCE-NO CHANGE ▪ , <br /> Inlets shall be screened or otherwise protected from entry by leaves or other material . <br /> Outdoor air inlets shall be located so os not to take air from the following areas: • <br /> a. Closer than 10 feet from an appliance vent outlet, unless such vent outlet is 3 feet • <br /> above the outdoor air inlet. 4o5x !Ex p.Fi =x 4ow ss • "' "''- .'U'C-HEIGHT CONCRETE-WALL - <br /> b. Where it will pick up objectionable odors, fumes or flammable vapors. 1 ------1= r 1 --- ::J "• - "1- ;- - - • <br /> c. A hazardous or unsanitory location. <br /> d. A room or space having any fuel-burning appliances therein. <br /> • <br /> e. Closer than 10 feet from a vent opening of a plumbing drainage system unless the W <br /> vent opening is at least 3 feet above the air inlet. • ^ <br /> f. Attic, crow) spaces, or garages. O <br /> /r .. <br /> A2. In bedrooms, provide one openable escape window meeting all of the following <br /> (R310.1), _ <br /> a. Openable area of not less than 5.7 sq.ft. _ • <br /> b. Ground floor window openable area of no less than 5 sq ft ti EXISTING FOUNDATION,TYP.--� MA/�1 Ix <br /> 0 <br /> c. Minimum clear height of 24" o U <br /> d. Minimum clear width 20" - ,� <br /> e Maximum finished sill height of 44" (R310.2.1) _ :• <br /> z till. W O <br /> c [�] <br /> A3. R3'.d 1 Smoke detection and no:`canon. All smoke alarms `l. / <br /> �! X: W^ Q! <0' <br /> _ F-1 O. <br /> shall be listed 'n accordance with UL 217 and installed in X�c d <br /> at accordance with the provisions of this code and the household .......... .............. L-: r 1 <br /> fire warning equipment provisions of NFPA 72. - _: W �"' 0 <br /> Household fire alarm systems installed in accordance with - Lil <br /> NFPA 72 that include smoke alarms, or a combination of ' " �I A W <br /> smoke detector and audible notification device installed as • <br /> I 8'-7" 13'-10" ��( <br /> y required by this section for smoke alarms, shall be permitted. - - <br /> 3U <br /> The household fire alarm system shall provide the some level of V X_ IQ' .-> <br /> smoke detection and alarm as required by this section for DN,NEW - (EX.FLOOR-ALL SLAB ON GRAOEI W o. <br /> 0 2ASEM ENT <br /> smoke alarms in the event the fire alarm panel is removed or the o: _ 1 <br /> D <br /> system is not connected to a central station. - ' LIVING -z iTl <br /> B3'3.2 Location. Smoke alarms shall be installed in the following v eunaw000 KITCHEN - _ ----NEW FOUNDATION • <br /> W ,,/ <br /> locations: -i HARDWOOD r Fy <br /> 1. In each sleeping room. `/ O <br /> 2 Outside each separate sleeping area in the immediate i Z W <br /> _. <br /> vicinity of the aeional s. l j� ",, :? G, X' L' _ W <br /> 3. On each additional story of the dwelling, including basements ,,. `� <br /> but not including crawl spaces and uninhabitable /.\I <br /> attics. In dwellings or dwelling units with spit levels and • <br /> lii - <br /> without an intervening door between the adjacent levels, ArQ7]y <br /> a smoke alarm installed on the upper level shall suffice -- <br /> for the adjacent lower level provided that the lower level -- <br /> is less than one full story below the upper level. � + A.4^ <br /> When more than one smoke alarm is required to be installed UP I A2 • <br /> • <br /> I A2 <br /> within an individual dwelling unit the alarm devices shall be TO A':IC FLe R li <br /> interconnected in such a manner that the actuation of one alarm - -' - "- - - - <br /> will activate all of the alarms in the individual unit. L—_.... I .::::: C �.::::: X :. <br /> R313.2.1 Alterations, repairs end additions. When alterations, ' ---- - � -- -- - - _ <br /> repairs or additions requiring a permit occur, or , <br /> when one or more sleeping rooms ore added or created in u <br /> existing dwellings, the individual dwelling unit shall be FOUNDATION PLAN a <br /> equipped with smoke alarms located os required for new , <br /> dwellings; the smoke dorms shall be interconnected and MAIN FLOOR PLAN ' ;_:' Date , <br /> hard wired. <br /> A4. The maximum difference in height between the top of the threshold and the finished i <br /> floor level of the exterior deck or landing at an exterior doorway shall not be more than --:'; F I I:.e NOTES -,: <br /> 7-3/4" below the top of the threshold, provided the door, other than on exterior storm or <br /> Screen door does not swing Over the landing. R311 4.3 I. WRITTEN DIMENSIONS TAKE PRECEDENCES. VERIFY ALL DIMENSIONS AND FIELD a. ALL BEAMS TO BE 4 X 10(SEE SHEET i <br /> OVER SCALED DIMENSIONS. CONDITIONS. FOR LUMBER STRENGTH VALUES). UNLESS <br /> 12. ALL FOOTINGS TO HAVE A MINIMUM 7. PROVIDE TEMPORARY BRACING AS NOTED OTHERWISE. <br /> A5. The floor or landing at exit doors shall not be more than 1-1/2" below the top of DEPTH OF 18'BELOW FINISH GRADE. REQUIRED. UNTIL ALL PERMANENT <br /> j 50>11 I STAL AND STIFFENINGS HAVE 12.ALL POSTS TO BE 4 X 4(4 X 6 AT <br /> the threshold. (R311.4.3) or shall have a step riser no greater than 7-3/4 (R311.4.3 and BEAM SPLICES)TYPICAL UNLESS NOTED <br /> ,3. STEP FOUNDATIONS PER SITE BEEN INSTALLED. OTHERWISE. <br /> R311.5.3) I CONDITIONS. <br /> 8, ROVIDE DOUBLE JOISTS OR BLOCKING 13.ALL ISOLATED SPREAD FOOTINGS TO HE <br /> 4. ALL CONCRETE FOOTINGS TO REST ONAT PARTITIONS ABOVE. 18'x 18'X 8'THICK WITH(2)H4 <br /> A6. Provide a tie for beams splices over supports. (2320.7) BARS BOTTOM EACH NAY,UNLESS NOTED <br /> FIRM UNDISTURBED EARTH VITH MINIMUM <br /> t A7. Two anchor boltsper 2.O00 LSG BEARING PRESSURE(REFER <br /> piece of foundation plate minimum, AL SOILS REPORT ACTH REQUIRED). OTHERWISE, Job No. 02121 <br /> I5. ORLMOSCNROD YNOROExPOSEDCT ITA TO EARTH ORSheet Of <br /> WEATHER TO BE PRESSURE TREATED. <br /> A8, A circulation air supply opening or duct of minimum rate of 1 cfm per 24000 BTU/h - - <br /> is required for the forced air system. (IMC706). if3 \3 <br /> ______ ...._.._ ............. .........._._ --___.._ ....___...__. . .___.._.___. ......... ......... ....._... ........._......_..r 4 <br /> T <br />