Everett Aire <br />Everett <br />California St <br />VICINITY MAP <br />SCALE: N.T.S. <br />91 <br />PROJECT DESCRIPTION: <br />EXISTING STRUCTURE / TWO STORY GARAGE TO BE REMODELED INTO A <br />DUPLEX, TWO UNITS (3 BEDROOM), DEMO EXISTING LOFT AND INTERIOR WALLS, <br />EXTERIOR WALLS AND ROOF EXISTING. <br />AREA PER UNIT: 526 SF. PARKING PROVIDED: 6 STALLS. <br />ARCHITECTURAL DRAWING INDEX <br />P. No. <br />SHEET <br />DESCRIPTION <br />1 <br />A0.0 <br />COVER SHEET <br />LANDSCAPE PLAN <br />2 <br />A0.1 <br />3 <br />Al <br />SITE PLAN <br />4 <br />A1.1 <br />AS -BUILT PLANS <br />AS -BUILT PLANS -- <br />5 <br />A1.2 <br />6 <br />A1.3 <br />DEMO PLANS <br />PROPOSED FLOOR PLANS <br />PROPOSED ELEVATIONS <br />SECTIONS <br />DETAILS <br />ENERGY <br />7 <br />A2 <br />8 <br />A3 <br />9 <br />A4 <br />10 <br />A6 <br />11 <br />A7 <br />STRUCTURAL DRAWING INDEX <br />P. No. <br />SHEET <br />DESCRIPTION <br />1 <br />S01 <br />STRUCTURAL NOTES <br />2 <br />S02 <br />FRAMING PLANS <br />3 <br />S03 <br />STRUCTURAL DETAILS <br />PROPERTY INFORMATION <br />OWNER <br />2713 MAPLE STREET LLC <br />STREET ADDRESS <br />2715 MAPLE ST A&B , EVERETT, WA 98201 <br />PARCEL NUMBER <br />00593663801200 <br />ZONING <br />MIXED URBAN (MU) <br />SQFT <br />526 SF PER UNIT <br />FRONT SETBACK <br />NA <br />SIDE SETBACK <br />NA <br />REAR SETBACK <br />NA <br />LEGAL DESCRIPTION <br />SWALWELLS 2ND ADD BLK 638 D-00 - LOT 12 & 13 <br />"M <br />GENERAL NOTES <br />ALL NOTES AND SPECIFICATIONS TO COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE AND <br />THE WASHINGTON STATE ENERGY CODE. <br />1. THE DRAWINGS ARE INTENDED TO DESCRIBE THE OVERALL SCOPE OF WORK FOR THE PROJECT. <br />ANY WORK NOT SHOWN HERE, BUT REQUIRED BY CODE, OR THE SPECIFICATIONS, OR TO MAKE THE <br />WORK COMPLETE, SHALL BE PROVIDED AS PART OF THIS WORK. <br />2. ALL WORK WITHIN THESE PLANS SHALL COMPLY WITH THE CURRENT EDITIONS OF THE <br />INTERNATIONAL RESIDENTIAL CODE, WASHINGTON STATE ENERGY CODE, WASHINGTON STATE <br />VENTILATION AND INDOOR AIR QUALITY CODE, UNIFORM PLUMBING CODE, NATIONAL ELECTRIC <br />CODE, AND WASHINGTON STATE DEPARTMENT OF LABOR AND INDUSTRIES REGULATIONS. <br />3. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL EXISTING AND NEW UTILITIES AND <br />SITE CONDITIONS BEFORE AND DURING CONSTRUCTION. INFORM DESIGNER OF VARIATIONS <br />BETWEEN CONTRACT DOCUMENTS AND EXISTING CONDITIONS. <br />4. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS ON SITE. <br />5. DIMENSIONS ARE TO FACE OF FOUNDATION WALLS AND FACE OF ROUGH FRAMING, UNLESS NOTED <br />OTHERWISE. <br />6. FLOOR TO FLOOR DIMENSIONS ARE FROM TOP OF SUB-FLR TO TOP OF SUB-FLR, UNLESS NOTED <br />OTHERWISE. <br />7. PROVIDE SOLID BLOCKING BEHIND ALL WALL HUNG FIXTURES AND ACCESSORIES. <br />8. PROVIDE 2" STRIP VENTS AT ALL CANTILEVERED AREAS. <br />9. DOOR RETURNS SHALL BE 4" TYPICAL, UNLESS NOTED OTHERWISE. <br />10. CONTRACTOR TO CONFIRM WINDOW AND DOOR ROUGH OPENING REQUIREMENTS WITH <br />MANUFACTURER(S). <br />11. ALL EXTERIOR WINDOW AND DOOR OPENINGS TO BE FLASHED WITH PEEL AND STICK WATER SHIELD <br />OR APPROVED EQUAL, PER NORTHWEST WALL AND CEILING BUREAU STANDARD DETAILS. <br />12. CONTRACTOR RESPONSIBLE FOR LEAD AND ASBESTOS TESTING AS REQUIRED. <br />13. DRAWINGS CONTAIN REPETITIVE ELEMENTS AND ARE NOT INDICATED EVERYWHERE. (SEE DETAIL <br />DRAWINGS) CONTRACTOR TO PROVIDE COMPLETED WORK AS IF DRAWN IN FULL. <br />14. ABBREVIATIONS OR PARTIAL CODE SECTIONS NOTED ARE INTENDED TO GIVE ADDITIONAL <br />INFORMATION. THE FULL TEXT OF THE CODE, AS INDICATED BY THE CODE SECTION REFERENCE, <br />ALWAYS APPLIES. <br />15. ELECTRICAL, MECHANICAL, PLUMBING AND FIRE PROTECTION WORK IS DESIGN BUILD. ELECTRICAL <br />WORK SHOWN HEREIN IS DIAGRAMMATIC AND INTENDED TO ILLUSTRATE THE DESIGN INTENT, NOT <br />SPECIFIC REQUIREMENTS. WORK REQUIRED BY APPLICABLE CODES OR TO MAKE THE WORK <br />COMPLETE IS TO BE PROVIDED. <br />16. CONTRACTOR SHALL VERIFY LOCATIONS AND SIZING OF ALL OPENINGS, INCLUDING BUT NOT <br />LIMITED TO HVAC, PLUMBING, DOORS AND WINDOWS WITH APPLICABLE SUBCONTRACTORS. <br />APPROVED <br />ment <br />office of Community. Planning & Eoonomicc oP <br />Pt IkNG 11 <br />DATE: 3.2g2� <br />N E:-.. <br />BUILDING CODE CONT'D <br />7H � 0I00UM NfA HAVE NOT BEEN <br />gQ <br />APo�OFo ?HE I U;t,N0E OF <br />PllkCE OAK „HANICAL, TIRE <br />Sll�° ati i 0TRIOAL OR <br />Additional Permits Are Required <br />For This Project To Include: <br />Plumbing ❑ Sprinkler <br />Mechanical ❑ Fire Alarm <br />Electrical <br />DUCT LEAKAGE TEST: ALL DUCTS / AIR HANDLERS ARE LOCATED INSIDE THE BUILDING ENVELOPE AND <br />DO NOT REQUIRE TESTING PER EXCEPTION FOUND IN SECTION R403.2.2 OF THE 2015 WASHINGTON <br />ENERGY CODE. <br />EXTERIOR LIGHTING: PROVIDE ARTIFICIAL LIGHTING ADJACENT TO ALL ENTRY DOORS AND STAIRS. <br />SHIELD LIGHT FROM ADJACENT PROPERTIES. <br />VENTILATION AND EXHAUST <br />• BATHROOMS, LAUNDRY ROOMS AND POWDER ROOM FANS TO BE 50 CFM. <br />• KITCHEN EXHAUST FANS TO BE 100 CFM MIN, 400 CFM MAX. <br />• EXHAUST FANS SHALL BE FLOW RATED AT .25 W.G. STATIC PRESSURE AND MAX. 1.0 SONE RATING <br />EXHAUST DUCTS SHALL: <br />• BE INSULATED TO R-4 IN UNCONDITIONED SPACE <br />• BE EQUIPPED WITH A BACK -DRAFT DAMPER <br />• TERMINATE OUTSIDE THE BUILDING <br />• COMPLY WITH DUCT LENGTH TABLE M1506.2 <br />1. ALL VENTILATION SYSTEM CONTROLS SHALL BE READILY ACCESSIBLE. SOURCE SPECIFIC <br />SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER <br />APPROVED MEANS. <br />2. THE BUILDING SHALL BE EQUIPPED WITH A WHOLE HOUSE VENTILATION SYSTEM CAPABLE OF <br />CONTINUOUS OPERATION PER TABLE M1507.3.3(1) <br />3. INTERMITTENTLY OPERATED WHOLE HOUSE VENTILATION SYSTEMS SHALL HAVE THE CAPABILITY <br />FOR CONTINUOUS OPERATION, AND SHALL HAVE A MANUAL TIMER AND AN AUTOMATIC CONTROL, <br />SUCH AS A CLOCK TIMER IF REQUIRED, AND SHALL BE SIZED PER TABLE M1507.3.3(2) <br />4. INTERIOR DOORS SHALL BE INSTALLED SO AS NOT TO IMPEDE THE MOVEMENT OF FRESH AIR TO <br />ALL HABITABLE ROOMS (1/2" UNDERCUT ABOVE TEH SURFACE OF FINISH FLOOR COVERING U.N.O.) <br />5. AIR INLETS SHALL NOT BE LOCATED CLOSER THAN 10' FROM AN APPLIANCE VENT OUTLET OR <br />PLUMBING VENT (UNLESS VENT OUTLET IS AT LEAST T ABOVE THE OUTDOOR AIR INLET). <br />6. VENTILATION DUCT FOR THE DRYER SHALL BE 4" DIA. METAL WITH A SMOOTH INTERIOR AND <br />PROVIDED WITH A BACK -DRAFT DAMPER CONCEALED IN CONSTRUCTION. INSTALL DRYER AND <br />EXHAUST PER MANUFACTURER INSTRUCTIONS. <br />7. EXHAUST HOOD SYSTEMS CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM SHALL BE PROVIDED <br />WITH MAKEUP AIR AT A RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. SUCH MAKEUP <br />AIR SYSTEMS SHALL BE EQUIPPED WITH A MEANS OF CLOSURE AND SHALL BE AUTOMATICALLY <br />CONTROLLED TO START AND OPERATE SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. <br />BUILDING CODE SUMMARY <br />BUILDING CODES USED: A PLANNING COMMENTS <br />• 2015 IRC & 2015 IBC Structural �\l �\2 BUILDING COMMENTS <br />R302.5 AND R302.6 - GARAGE/HOUSE REQUIREMENTS (WHERE APPLICABLE PER PLAN): <br />• DOOR: 1-3/8" THK MIN. SOLID CORE OR 20 MINUTE FIRE -RATED DOOR, EQUIPPED WITH SELF CLOSING DEVICE. <br />• 1/2" REGULAR GYP BOARD SHALL BE INSTALLED AT GARAGE SIDE OF WALLS SEPARATING GARAGE AND <br />DWELLING U.N.O. <br />• 5/8" TYPE "X" GYP BOARD OR EQUAL SHALL BE INSTALLED AT GARAGE CEILING WHERE DWELLING OCCURS <br />ABOVE <br />• 1/2" REGULAR GYP BOARD SHALL BE INSTALLED AT STRUCTURE(S) SUPPORTING FLOOR/CEILING ASSEMBLIES <br />R_303.7 AND R303.8 - STAIRWAY ILLUMINATION: PROVIDE PRIMARY POWER FROM BUILDING WIRING. <br />• INTERIOR STAIRS - PROVIDE ARTIFICIAL LIGHT SOURCE AT EACH LANDING CAPABLE OF ILLUMINATING NOT LESS <br />THAN (1) FOOT-CANDLE MEASURED AT THE CENTER OF THE TREADS/LANDINGS. <br />• ACTIVATION - PROVIDE WALL SWITCH AT EACH FLOOR LEVEL WHERE STAIRWAY HAS (6) OR MORE RISERS. <br />• EXTERIOR STAIRS - PROVIDE ARTIFICIAL LIGHT SOURCE AT THE TOP LANDING. <br />R304 AND R305 ROOM DIMENSION REQUIREMENTS: Subject To Field Inspection <br />• GENERAL 7'-0" MINIMUM HABITABLE SPACE CEILING HEIGHT. <br />• 6'-8" MINIMUM CEILING HEIGHT IN BATHS, TOILET ROOMS, OR LAUNDRY ROOM. <br />• SLOPED CEILING (MIN. 5'-0" MUST MEET MINIMUM HEIGHT OVER 1/2 OF THE AREA.) <br />• MINIMUM FLOOR AREA FOR A HABITABLE ROOM IS 70 SQ. FT. <br />• 7' MINIMUM WIDTH FOR HABITABLE ROOM. <br />• BEAMS, GIRDERS, DUCTS, OR OTHER OBSTRUCTIONS IN BELOW GRADES CONTAINING HABITABLE SPACE SHALL <br />BE PERMITTED TO PROJECT TO 6'-4" A.F.F. <br />R307.2 - BATHTUB AND SHOWER SPACES: TUB/SHOWER LOCATIONS TO BE FINISHED WITH A NON -ABSORBENT <br />SURFACE TO A MIN. OF 72" A.F.F. INSTALL AND SEAL ALL ACCESSORIES TO PROTECT STRUCTURAL ELEMENTS <br />FROM MOISTURE. <br />R308 GLAZING: ALL GLAZING IN HAZARDOUS LOCATIONS SHALL RECEIVE SAFETY GLASS. THE SAFETY GLASS <br />DESIGNATION SHALL BE VISIBLY MARKED ON EACH WINDOW AS REQUIRED BY CODE. SEE PLANS FOR SPECIFIC <br />SAFETY GLASS LOCATIONS (SG). <br />R310 EMERGENCY ESCAPE AND RESCUE OPENINGS (EERO'S): <br />• ALL EERO'S SHALL HAVE A NET CLEAR OPENING OF 5.7 SQUARE FEET, WITH MIN. NET CLEAR HEIGHT OF 24" AND <br />NET CLEAR WIDTH OF 20. <br />• EERO'S SHALL BE OPERATIONAL FROM INSIDE THE ROOM w/o THE USE OF KEYS, TOOLS OR SPECIAL <br />KNOWLEDGE. <br />• MIN. HORIZONTAL AREA OF WINDOW WELLS SHALL BE 9 SQUARE FEET, WITH MIN. PROJECTION AND WIDTH OF <br />36". THE WINDOW WELL SHALL ALLOW THE EERO'S TO BE FULLY OPENED. <br />R_3_11.3 - FLOORS AND LANDINGS AT EXTERIOR DOORS: <br />• A LANDING IS REQUIRED ON EACH SIDE OF AN EXTERIOR DOOR, AND SHALL BE NO LESS THAN 36" MEASURED IN <br />THE DIRECTION OF TRAVEL, AND THE WIDTH BE NO LESS THAN THE DOOR SERVED. <br />- EXCEPTION: EXTERIOR BALCONIES LESS THAN 60 SQ. FT. ARE PERMITTED TO HAVE A LANDING LESS THAN 36" <br />IN THE DIRECTION OF TRAVEL. <br />• THRESHOLD AT EXT. DOORS SHALL BE NO MORE THAN 1-1/2" ABOVE THE LANDING <br />R311.7 STAIRWAYS: <br />• STAIRWAYS SHALL NOT BE LESS THAN 36" MIN. CLEAR, ABOVE THE PERMITTED HANDRAIL HEIGHT. <br />• MIN. HEADROOM OF THE STAIRWAY SHALL NOT BE LESS THAN 6'-8". <br />• MAX. RISER HEIGHT IS 7 3/4". OPEN RISERS ARE ALLOWED WITH OPENING BETWEEN TREADS THAT DOES NOT <br />PERMIT THE PASSAGE OF A 4" DIA. SPHERE. <br />• MIN. TREAD DEPTH IS 10". <br />• LANDING WIDTH SHALL BE NO LESS THAN THE WIDTH OF STAIRWAY, AND MIN. 36" DEPTH. <br />• HANDRAIL HEIGHT, MEASURED VERTICALLY, SHALL BE BETWEEN 34" AND 38". HANDRAILS SHALL BE <br />CONTINUOUS FOR FULL FLIGHT. HANDRAIL ENDS SHALL BE RETURNED OR SHALL TERMINATE IN NEWEL POSTS. <br />R312 GUARDS AND WINDOW FALL PROTECTION: <br />• GUARDS SHALL BE LOCATED ALONG OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS AND <br />LANDINGS, THAT ARE LOCATED MORE THAN 30" MEASURED VERTICALLY TO THE FLOOR / GRADE BELOW. <br />• MIN GUARD HEIGHT SHALL BE 36". WHERE THE TOP OF GUARDS ALSO SERVE AS A HANDRAIL ON THE OPEN SIDE <br />OF STAIRS, TOP OF GUARDS SHALL BE BETWEEN 34" AND 36" <br />• OPENINGS IN GUARDS SHALL NOT ALLOW PASSAGE OF A 4" DIA. SPHERE. THE TRIANGULAR OPENING AT THE <br />SIDE OF OPEN STAIRS SHALL NOT ALLOW PASSAGE OF A 6" DIA. SPHERE. <br />• WHEN THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72" ABOVE FINISH GRADE BELOW, THE <br />LOWEST PART OF CLEAR OPENING SHALL BE MIN. 24" A.F.F. IF CLEAR OPENING IS LESS THAN 24", MAX WINDOW <br />OPENING SHALL NOT ALLOW PASSAGE OF A 4" DIA. SPHERE. <br />R314 SMOKE DETECTORS / R315 CARBON MONOXIDE ALARM: PROVIDE A SMOKE DETECTOR AND CARBON <br />MONOXIDE (HARDWIRED, INTERCONNECTED w/ BATTERY BACKUP) IN THE FOLLOWING LOC.: <br />• IN EACH SLEEPING ROOM (SMOKE DETECTOR ONLY) <br />• OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. <br />• MINIMUM ONE AT EACH STORY OF THE DWELLING INCLUDING BELOW GRADE. <br />R319 - SITE ADDRESS: EACH BUILDING SHALL BE PROVIDED WITH APPROVED ADDRESS IDENTIFICATION WHERE SIZE <br />AND LOCATION OF NUMBERS/ALPHABETICAL LETTERS ARE PER R319.1 <br />THERMOSTATS: <br />• PROVIDE MIN. (1) ONE PROGRAMMABLE THERMOSTAT FOR THE REGULATION OF TEMPERATURE. <br />• THERMOSTAT TO ABIDE BY SECTION R403.1.1 OF THE 2012 WASHINGTON ENERGY CODE. <br />PROJECT TEAM: <br />OWNER: <br />2713 MAPLE STREET LLC <br />P.O BOX 1094, <br />WOODINVILLE, WA 98072 <br />(425) 244 0007 <br />ismail.seattle@gmail.com <br />STRUCTURAL ENGINEER: <br />Jon Conner PE, SE <br />Structural Engineer I <br />Lakeview Structural Engineering <br />715 99th Ave SE <br />Lake Stevens, WA 98258 <br />(206) 914 9536 <br />LakeviewSE@outlook.com <br />CONTRACTOR: SURVEYOR: <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />:00 <br />' <br />O -0 <br />C)rD 0 <br />�. o 0 <br />a <br />rn rD <br />m w <br />0M <br />D <br />rD <br />rt <br />�� <br />� <br />Z� <br />f`c <br />o <br />w <br />O p <br />v z <br />�LA <br />CON- CU <br />Q <br />P: (4, <br />ADDf' <br />5403 <br />Marys-----. --- <br />- <br />arkitech.draftingstudio@gmail. com <br />CONSTRUCTION: <br />REVISIONS <br />z <br />O <br />Z <br />o <br />W <br />(� <br />o x <br />W <br />U) <br />I.LJ <br />N <br />o <br />U - <br />W (j <br />z <br />o <br />Cr <br />W <br />N N <br />O <br />N cli <br />Q <br />o 0 <br />Oz <br />1PZ11 <br />=WEV <br />DR <br />MAY 16 <br />2022 <br />CITY OF EVERE <br />Permit Services <br />T <br />(D <br />00 <br />d) <br />Q <br />W <br />X <br />CD <br />CO <br />LJJ I- <br />O <br />J <br />N <br />z <br />-J <br />W <br />-J L <br />,- <br />CD <br />C <br />W <br />CY) <br />Q <br />C) W <br />W <br />CY) <br />o <br />LL! 0D <br />0) <br />W Q <br />O <br />Q <br />O <br />Q <br />�' J <br />z <br />L <br />C/) LU <br />. . <br /># <br />w <br />-� <br />� I--- <br />W <br />U <br />cr <br />Q J <br />Q <br />Q <br />Ln <br />T- <br />rl- <br />CV <br />DATE: <br />05-09-2022 <br />COVER SHEET <br />A0e0 <br />PAGE No: 1-11 <br />rip O rt rrDD <br />:3ai <br />= ro <br />rt �, a rt <br />a <br />m U) <br />II V N <br />=CGo <br />a 3 b <br />IDMMN <br />_ F F r <br />m <br />r-00 <br />n <br />