• <br /> Thank you, <br /> Chris Lieb—ADT Commercial Security <br /> 360-395-2625 <br /> From: Lieb,Christopher <br /> Sent:Tuesday, November 9,2021 11:46 AM <br /> To:sgoforth@everettwa.gov <br /> Subject:Service Alternatives-Fire Alarm design-1614 Broadway <br /> RE: Fire Alarm installation <br /> Service Alternatives <br /> 1614 Broadway <br /> Everett,WA,9820 <br /> Hello Steve, <br /> I am following up our phone conversation last week regarding installation of a Fire Alarm at Service Alternatives in <br /> Everett. I apologize for the delay getting back to you on this.To recap:they have an existing Security Alarm(intrusion <br /> detection)which includes 3 smoke detectors located in general areas. We are proposing to upgraded and expand the <br /> Security Alarm which means, by ADT policy as well as code considerations,that we cannot keep the smoke detectors in <br /> the Security Alarm. <br /> The building owner would like to have some fire detection but the only way ADT can fulfill that need is to install a UL Fire <br /> Alarm control panel and UL commercial fire alarm devices in compliance with NFPA72. We can consider reductions in <br /> coverage to NFPA standards for placement or spacing of devices but only with documented approval by the AHJ. <br /> Following our conversation I prepared the attached preliminary design,which to the best of my knowledge provides <br /> NFPA72-compliant detection coverage but a reduced notification plan consistent with what we agreed to when we <br /> talked. Note:dimensions are approximate and the drawing is not accurate to scale but each room is smaller than 30ft x <br /> 30ft with 9 to 10ft ceilings except the ground floor Conference Room which is about 30ft x 35ft,and the top floor <br /> conference room&adjacent offices which have a vaulted ceilings of about 15ft. Please review the drawings and <br /> respond with your recommendations. <br /> In order to mitigate the cost to the Customer we would like to submit for the permit using these simple design <br /> drawings. This would eliminate engineering fees except for battery calcs and equipment documentation. Please let me <br /> know if that is acceptable. <br /> Thank you for your time and consideration. <br /> Best Regards, <br /> Christopher Lieb <br /> Senior Commercial Security Consultant <br /> 11824 North Creek Parkway N Suite 105 I Bothell,WA 98011 <br /> Direct:360-395-2625 Email: cblieb@adt.com <br /> www.adt.com/commercial <br /> A Commereioll Pawned by Exprrionco.Driven by Excellence <br />