Interior.Lighting Space-13y Space Method LTG-INT-SPACE <br /> • 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Wendy's Kitchen addition&Alteration-1510 Broadway Date 8/26/2018 <br /> Calculation 0 0 Addition- Q Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> Q Spaces where<50%of Q Spaces where a 50%of Q <br /> luminaires are replaced luminaires are replaced <br /> LPA ® Standard 0 Additional Efficiency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Ceiling Gross Interior Allowed Watts Allowed <br /> room#) Space Type HeightNOTE 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Kitchen Food preparation 7'—10" 815 0.790 644 <br /> Walk in Cooler Storage room 7'—6" 250 0.500 125 <br /> Freezer <br /> Total Area 1065 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 769 <br /> Proposed Lighting Wattage""'°' <br /> Location(plan#, Number of Watts/ a Watts <br /> NOTE 4,5,6 NOTE 7 ,,,,,„1,-;;; k <br /> room#) Fixture Description Fixtures FixtureProposed <br /> Kitchen LSI 2x4 LED 2 lamp troffer 17 40 680 <br /> walk in <br /> cooler/freezer 40w incandescent lamp 3 20 60 <br /> 0440:k <br /> yre. _4 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 740 <br /> Interior Lighting Power Allowance COMPLIES <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c. If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided <br />