Laserfiche WebLink
Lighting, Motor, and Electrical Permit'Checklist, Pg. 4 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 <br /> Revised August 2016 <br /> Project Title: Wendy's Kitchen addition&Alteration-7514 Evergreen Wy 'Date 8/6/2018 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability <br /> Location in Building Department <br /> (yes,no,na) Code Section Component (Compliance information required in permit documents I Documents I Notes <br /> MOTORS&TRANSFORMERS <br /> t C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; <br /> indicate transformer size,efficiency,or exception taken <br /> Dwelling unit <br /> Indicate on electrical plans that each dwelling unit in Group R-2 <br /> C405.7 electrical energy <br /> consumption has a separate electrical energy meter <br /> Electric motor Include all motors,including fractional hp motors,in electric <br /> C405.8 motor schedule on electricalplans;indicate hp,rpm,rated <br /> efficiency p <br /> efficiency,or exception applied <br /> For luminaires in each elevator cab,provide calculated average <br /> efficacy of combined fixtures that indicates efficacy is not less <br /> than 35 lumens per watt; <br /> C405.9.1 Elevator cabs Indicate rated watts per cfm for elevator cab ventilation fans do <br /> not exceed 0.33 watts per cfm; <br /> Indicate automatic controls that de-energize lighting and <br /> ventilation fans when elevator is stopped and unoocupied for a <br /> period of 15 minutes or more <br /> Escalators and Indicate escalators comply with ASME Al 7.1/CSA B44; <br /> C405.9.2 moving walks automatic controls are configured to reduce operational speed <br /> to the minimum permitted when not in use <br /> C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided <br /> with a variable frequency regenerative drive <br /> Identify all controlled and uncontrolled receptables on electrical <br /> plans in each space in which they are required;include <br /> Controlled receptacle configuration such as spacing between controlled <br /> C405.10 and uncontrolled,duplex devices,etc; <br /> receptacles <br /> Indicate on plans whether the method of automatic control for <br /> each controlled receptable zone is by occupant sensor or <br /> programmable time-of-day control <br /> If"no" is selected for any question,provide explanation: <br /> End of Lighting,Motor&Transformer Permit Documents Checklist <br /> II <br />