Laserfiche WebLink
NEW STAINLESS STEEL SCREW WITH <br /> EPDM WASHER AT 12" O.C. <br /> FLEECE SEPARATOR ADHERED TO CURB <br /> TPO MEMBRANE FLASHING, ADHERED <br /> EXISTING WOOD <br /> REMOVE THE PERLITE / FIBER CANT STRIP CURB <br /> FASTENER & SEAM PLATE AT 12" O.C. EXTEND TPO <br /> // ZEOMOBDRBOVERANE <br /> HEAT WELDED SEAM to/// <br /> NEW TPO ROOF SYSTEM <br /> /hill <br /> EXISTING SHEET METAL <br /> \\\\\ \\\\\\\ \\\\\\\ \ \\\\\\\\\ \ \\\\\ \ \ \ <br /> FASCIA, REMOVE, <br /> SALVAGE & REINSTALL <br /> ><. <br /> NEW STAINLESS STEEL <br /> SCREW AT 24" O.C., <br /> EXISTING PRECAST PAINTED TO MATCH <br /> CONCRETE WALL PANEL a - METAL COLOR <br /> NOTES: <br /> 1) IT IS PRESUMED THAT THERE IS A PERLITE / WOOD FIBER CANT STRIP AT THE BASE OF THE CURB. IF IT IS <br /> PERLITE OR FIBERBOARD THE CANT SHALL BE REMOVED. IF THE CANT IS SOLID WOOD IT SHALL REMAIN. <br /> 2) REMOVE THE EXISTING BUILT-UP ROOF FLASHING FROM THE WOOD CURB. COVER THE CURB WITH FLEECE <br /> TO PROVIDE SEPARATION AND LEVELING FOR THE NEW TPO FLASHING. <br /> 3) REMOVE, SALVAGE AND REINSTALL THE EXISTING SHEET METAL FASCIA. CATALOG / LABEL EACH PIECE SO IT <br /> IS REINSTALLED AT THE SAME LOCATION. PROVIDE TOUCH-UP PAINT TO RESTORE THE PAINT FINISH AFTER <br /> REINSTALLATION. <br /> 4) PROVIDE NEW SEALANT AT THE LAP JOINTS IN THE FASCIA METAL. THE SEALANT SHALL CLOSELY MATCH THE <br /> COLOR OF THE PAINT FINISH. <br /> PROJECT: Iron Mountain <br /> 6600 Hardeson Road <br /> 1RD&I Everett, WA <br /> Roof Design & Inspection, Inc. ROOF EDGE FLASHING AT WEST SIDE <br /> 1115 Tucker Road I Dartmouth, MA 02747 <br /> tel 508.965.1793 I www.roofdesignandinspection.com EJT'L 0 2 DATE: 01/02/22 <br /> SCALE: N.T.S. <br />