Laserfiche WebLink
1 2 <br />3 <br />q <br />6 <br />Wall Legend <br />General Notes - Residential Floor Plans <br />Keynote Legend <br />MTL. FRAMED WALL <br />A EXTERIOR DIMENSIONS ARE TO THE OUTSIDE FACE OF STUDSUNLESS <br />M. CONTRACTOR TO CONFIRM ALL CLEARANCE REQUIREMENTS AS NOTED ON <br />- <br />STANDARD WALL <br />OTHERWISE NOTED. <br />B. DIMENSIONS AT UNIT DEMISING WALLS ARE TO CENTERLINE OF WALL. <br />C. INTERIOR DIMENSIONS ARE TO THE FACE OF STUDS AT FRAME WALLS, AND TO <br />DETAIL A6.01. <br />N. REFER TO DETAILS ON SHEET A6.01 FOR TYPICAL DOOR CLEARANCES. <br />O. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS AT FIRE RATED WALLS, <br />27 3200.A TWO-WAY COMMUNICATION SYSTEM W/ AUDIBLE AND VISIBLE <br />CENTERLINE OF COLUMNS UNLESS OTHERWISE NOTED. <br />INCLUDING BUT NOT LIMITED TO PIPING, DUCTS, CONDUIT, ETC., WITH <br />SIGNALS <br />' <br />D. DIMENSIONS LOCATING DOORS, WINDOWS AND RELIGHTS ARE TO NOMINAL <br />OTHERWISE NOTED. <br />FIRESTOPPING PER I.B.C. REQUIREMENTS. <br />P. SEE EXTERIOR ELEVATIONS FOR WINDOW AND LOUVER TYPES AND DETAILS. <br />DYKEMAN <br /># <br />INSULATED OR ACOUSTIC WALL <br />MASONRY OPENING OR TO FINISH OPENING UNLESS <br />E. SEE WALL TYPES ON SHEET A1.01 FOR TYPICAL WALL CONSTRUCTION <br />Q. SEE ENLARGED PLANS FOR ADDITIONAL DIMENSIONAL AND NOTE <br />C <br />- <br />ASSEMBLIES. <br />INFORMATION. <br />F. ALL NON -BEARING WALLS ARE FULL HEIGHT TO UNDERSIDE OF FLOOR ABOVE. <br />R. TYPICAL WALLS AT UNIT INTERIORS ARE WALL TYPE WN 411 UNLESS NOTED <br />DESIGNARCHITECTURE + <br />WOOD FRAMED WALL <br />G. APPLY TWO (2) CONTINUOUS SEALANT BEADS BENEATH STUD TRACK AT ALL <br />OTHERWISE. FOR TYPICAL WALLS AT UNIT INTERIORS REFER TO UNIT 201 ON <br />EXTERIOR STUD WALLS. <br />SHEET A4.22A. <br />STANDARD WALL <br />H. CONTRACTOR SHALL PROVIDE CONTINUOUS HORIZONTAL BLOCKING AT ALL <br />WALL MOUNTED LAVATORIES, DRINKING FOUNTAINS, CASEWORK, MIRRORS, <br />S. SENSORY ACCESSIBLE UNITS PROVIDED PER UFAS SECTION 4.28.2 AND 4.28.3 <br />WITH: <br />HANDRAILS, ETC. REFER TO ARCHITECTURAL INTERIOR ELEVATIONS AND <br />a. AUDIBLE ALARMS -AUDIBLE EMERGENCY ALARMS , SHALL PRODUCE A <br />MECHANICAL DRAWINGS. <br />SOUND THAT EXCEEDS THE PREVAILING EQUIVALENT SOUND LEVEL IN THE <br />INSULATED OR ACOUSTIC WALL <br />1. SEE DETAIL SHEET AS.01 FOR TYPICAL MOUNTING HEIGHTS FOR WALL <br />ROOM OR SPACE BY AT LEAST 15 DECIBELS OR EXCEEDS ANY MAXIMUM <br />E <br />MOUNTED ACCESSORIES AND EQUIPMENT. <br />SOUND LEVEL WITH A DURATION OF 30 SECONDS BY 5 DECIBELS, <br />E <br />J. SEE INTERIOR DESIGN DRAWINGS FOR TRANSITION DETAILS AND THRESHOLDS. WHICHEVER IS LOUDER. SOUND LEVELS FOR ALARM SIGNALS SHALL NOT <br />K. ELECTRICAL PANELS, TRANSFORMERS, BOILERS, AIR HANDLING UNITS, AND <br />EXCEED 120 DECIBELS.CONSULTANT: <br />DUCTWORK WHEN SHOWN, ARE INDICATED FOR CONTRACTOR CONVENIENCE. <br />b. VISUAL ALARMS - ELECTRICALLY POWERED INTERNALLY ILLUMINATED <br />SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR SPECIFIC SIZES AND <br />EMERGENCY EXIT SIGNS SHALL FLASH AS A VISUAL EMERGENCY ALARM IN <br />LOCATIONS. <br />CONJUNCTION WITH AUDIBLE EMERGENCY ALARMS. THE FLASHING <br />L. SEE MECHANICAL AND ELECTRICAL PLANS FOR CEILING MOUNTED EQUIPMENT. <br />FREQUENCY OF VISUAL ALARM DEVICES SHALL BE LESS THAN 5 HZ. IF SUCH <br />- <br />ALARMS USE ELECTRICITY FROM THE BUILDING AS A POWER SOURCE, <br />THEN THEY SHALL BE INSTALLED ON THE SAME SYSTEM AS THE AUDIBLE <br />EMERGENCY ALARMS. <br />142'-11" <br />6467 REGISTERED <br />1"@EXT F.O. STUD-,5'-6" 16'-01/2 18,-11/4" 1. <br />TO'-0112" 12'-8114" 15'-10' 15'-10" <br />15'-10" 12'-6" 20'-61/2"4ri.-51l2'@EXT <br />F.O. STUD <br />ARCHITECT <br />❑ - HATCHED AREA INDICATES <br />❑ <br />TI D Y JAMES EWEIT <br />S ATE aF WASIII GTON <br />CEILING ABOVE TO BE 2 <br />N PIN LAYERS OF 5/8" GWB ON <br />O 2 RSIC-1 CLIPSAND CAVITY <br />P PW <br />2 <br />1 <br />I- <br />O <br />--• • • <br />F A3.12 W/ 8" BATT INSULATION 5 A3, 11 A3.11 <br />K <br />D <br />D <br />w 1 <br />A4.51 <br />CS <br />1 w <br />CS. <br />4,14 <br />_ — <br />— _ — — _ _ -- _ - <br />------ _ ------ _ — — — — — — — <br />— — — — — — — — — — — <br />HOPEWORKS <br />8TAIR#2. i8TUDI0U n �,6E�Unk I �,BED Uoh�DUnR <br />STUDIDUn@ — <br />— — — 6 <br />STATION 2 <br />T hypeL. <br />408 407 k <br />ST#z Type a Tme B I T a <br />406 J 1. 405 404 <br />Type$ Types <br />L 403 402 <br />3(!.4 SF a; 373 SF 372 SF <br />is , 397 SF .309 SF <br />FOR <br />u <br />a <br />1 <br />HOUSING HOPE <br />m <br />2iBEDUnit <br />3 4,' <br />_ ,, I <br />-TY <br />j <br />AT <br />26 <br />5329E <br />1�. L <br />;t I <br />- <br />3315 BROADWAY, <br />EVERETT, WA <br />I4-0"@EO va2oo.A <br />FDA <br />CS <br />CONFORMED SET <br />05/15/2018 <br />LAI <br />Y <br />ROOF GARDEN r� <br />i <br />This drawing is: <br />7. Copyright 2017 Dykeman, Inc. <br />O <br />ELEC. 424 -EQ EQ EQ EQ EQ 423 <br />SF II N.B.: <br />2 / q� WH �'_. - REFER TO LANDSCAPE FD ( 2 - <br />-{ J! {s�g� <br />C <br />z <br />3.10 :I tfii�® -1 <br />c7 <br />;FOR PAVERS &LAYOUT <br />O' - .__ <br />- <br />z - -+� <br />A3.10 <br />' <br />2.The/vchitecYs Instrument of Professional Service. <br />o_--- <br />o O <br />¢ <br />I <br />3. For use on this project only. Obtain or re eo d <br />written permission for any other use or reproduction. <br />' <br />1 _ <br />a I 25'-712' <br />T-51/i <br />STUDIO Unit <br />`•.� <br />• <br />PROJECT <br />Type-B ._.. <br />40s r 0 <br />314 SF X '-7" ROM <br />`` I .= " <br />COL CTRJO FOS OPEN BELOW <br />(COURTYARD @ L2) <br />u <br />STORAGE <br />5'-7" FROM COLU CTR OS q22 <br />- <br />1 <br />— <br />2016-025 <br />3,10 <br />f 5� <br />A3.10 <br />• <br />a <br />N.B.: <br />- <br />F <br />L 1 <br />MARK DATE DESCRIPTION <br />11/16/2017 <br />Pricing Set <br />_ STUDIO Unit L <br />REFER TO LANDSCAPE <br />O <br />12/08/2017 <br />Pemut Set <br />j Type$ - FOR PAVERS & LAYOUT 3 ! i <br />410 <br />0 -- <br />1 1 <br />O <br />O`_ 7BED <br />Un@� <br />02/08/2018 <br />Bid Set <br />309.SF <br />- -- <br />I I�"__—_ <br />- _ — - — — . <br />( Typ" <br />- <br />ADD#1 <br />0222/2018 <br />Addendum#1 <br />R <br />031 8 <br />B ermlt evisio <br />CS <br />051142018 <br />Conformed Set <br />A _ 405 <br />�✓ <br />SF <br />�? <br />__ 7 <br />z_0_ <br />C­ _— <br />- <br />m- ---- <br />`v STUDIO Unit - - ._ 1 <br />FQ <br />w Type <br />F-411��_.._ <br />j 310SF <br />�_ - _ I <br />�� s <br />TTygpOe$n <br />_._ <br />rt to <br />WH <br />_-!IIPN� <br />_-__ <br />-- <br />. <br />`< .r 306 SF <br />WH p,L L <br />f <br />B <br />I <br />STUDIO Unit'=� <br />I Type-3 _- v <br />(W H 1 I <br />1 > >; 27 ! -=.v l' 2 QED IMit <br />I SOLAR PANEL <br />B <br />1 _ _ ._ <br />ABOVE (TYP) <br />--• <br />360 SF <br />0 <br />CS ! <br />- <br />-4-1-9 <br />- 671 SF <br />PRINCIPAL IN CHARGE: I T <br />PROJECT MANAGER: DH <br />F <br />a - j <br />,; ... <br />PROJECT ARCHITECT: <br />MS HITEC <br />JOB CAPTAIN: GM <br />L � <br />2 <br />STUDIO Unit <br />1 BED Unit Typed <br />rt <br />- 1 BED Unit Typ" <br />Tme4B I 416 <br />A3.112 i ABED Unit ! S - � 509 SF I I 79O <br />Typ 7- 418 <br />417 296 SF <br />4�'1__--78 F �l f� f� <br />I <br />A3.12 <br />L 1� <br />T41P " <br />r <br />_ � _ <br />1 Ty U� - 445 SF <br />j 437 SF <br />r! ji,� -.. STYl1 <br />_ — - - — " — - — - — - _ _ . — -A-- - <br />4.24C <br />— - _ . _ - P - — - — - _ _ — . — - P - — - — - — _�_ — _ — _ — . <br />— . - " — - — " — _ — - — - — - — - — — - —I_ — _ — _ — _ _ - — . <br />0 <br />— _�. _ a <br />1 <br />� 4.24D <br />DRAWING TITLE: <br />D.9 <br />A <br />7"@EXT F.O. STUD <br />C t� <br />(-lOOI� Plan LeVP.I 4 <br />14'-11" 1T-1314" 2&-T' <br />- 15'-10" 25'-9' <br />14'-0" 14'-0" 22'-10 IX' <br />1'-51/2'@EXT F.O. STUD <br />DRAWING <br />• I <br />Q <br />G <br />an -Level 4 0 4' 8' 16, _ <br />� Floor Plan <br />N <br />Z <br />Sc ale: 1/8" = 1'-0" <br />11 2 <br />3. <br />41 <br />5 <br />1 6 <br />