Laserfiche WebLink
Architectural. Cotn:rit.ents. <br />4, This comment has not been completely addressed. Detail 03/A a01. should he insulated <br />as an e tenor° wall .e., R-21. plus R-4ci) unless the garage foundation Details :1.4A/A .01. <br />and 14B/A .01 are insulated and provided with a thermal break from the interior slab - <br />on -grade, Note that additional action is required for thefoundation details per <br />Architectural r°al Comment 5 and Structural Comment 17, See WSEC-1.5 'Fable 11402.1.,1. <br />drawingsResponse: Detail 03/A9.01 revised please refer to the updated. drawings. Please refer <br />structural <br />«,m This c.oraxme.n., has not been corn1.`w..e1y addresseA The original comment stated. that <br />Detail. 14/A .01 shows a thickened. slab edge at the slab -on -grade SOG), Detail <br />14../A .11:l has been provided, and the original detail appears to have been inod:ifie:d into <br />Detail 14B/A .OL .Note that additional action is required for the foundation details per <br />Architectural Coninient 4 and. Structural Cctmirent 17. See Section 1 106.1."1. The <br />following c°cinitnents should. be addressed: <br />li. This cornrnerit h.as trot been addressed. Sheet A1.0 -A and the building sections on. <br />Sheets A5,01 through A5.03 specify 114.0 :insulation Tinder the SDG. Detail 14 dues <br />riot show the i.nsri.lation., and dotes .not provide a tlterrnal break per Detail D/Si, The <br />detail should be revised. <br />c. Detail 14,E appears to be a duplicate of Detail, E/Si, and. should be reriiov ed.. <br />d. Detail 141 does not appear consistent with the foundation plans and. should be <br />revised. Note that the location of these details dries not appear to be specified in. the <br />plans and earnnot be fully reviewed; the location where the detail applies should be <br />specified. <br />Response: There's no R-10 insulation under the SO . Please refer to revised. A5.01 through <br />5.03 and. Structural details for foundation details. <br />. This c:.onn-lent has not bcw°°.err. addressed. The wrigimal. eoxiirrienat stated that Detail <br />13/A9.01 appears to include a steel. bearn that dotes -.not appear to include steel. framing, <br />The response indicates revisions have been perfl)rrned to the. structural drawings, which <br />does not appear to be correct, In. addition., the detail has been crossed. out, but it <br />appears the earls is still .required in the design, for the skylight system.. The detail and. <br />response should be revised. See. Section i 106,1 J. <br />Response: Please refer to revised 13/ A .01. <br />Design Lyric LLC (425) 836-4800 9824 223rd Place NE, Redmond, WA 98053 <br />