DESIGN DATA <br />TARGET DESIGN VALUES (Factors of Safety - Static / Seismic) <br />Minimum Factor of Safety for the sliding along the base <br />Minimum Factor of Safety for overturning about the toe <br />Minimum Factor of Safety for bearing (foundation shear failure) <br />MINIMUM DESIGN REQUIREMENTS <br />Minimum embedment depth <br />INPUT DATA <br />Geometry <br />Wall Geometry <br />Design Height (top of leveling pad to finished grade at top of wall) <br />Embedment (measured from top of leveling pad to finished grade at toe) <br />Leveling Pad Depth <br />Face Batter (measured from vertical) <br />Slope Geometry <br />FSsl = 1.5 / 1.1 <br />FSot = 2.0 / 1.5 <br />FSbr = 2.0 / 1.5 <br />-Seismic requirements are 75% of <br />Min_emb = 1.0 ft <br />H =7.00 ft <br />emb =1.00 ft <br />LP =0.50 ft <br />i =4.5 deg <br />Slope Angle (back slope angle measured from horizontal) P =0.0 deg <br />Slope toe offset (horiz. bench from wall to toe of slope) STL_offset =0.0 ft <br />Slope Length (horiz. length from wall to top of slope) SL_Length =0.0 ft <br />NOTE: If the slope toe is offset or the slope breaks within three times the wall height, <br />a Coulomb Trial Wedge method of analysis is used. <br />Surcharge Loading <br />Live Load (assumed transient loading (e.g. traffic)) LL = 250 psf <br />Live Load Offset (measured from back face of wall) ILL _offset = 1.0 ft <br />Live Load Width (assumed strip loading) LL_width = 20.0 ft <br />Soil Parameters <br />Reinforced Zone <br />Angle of Internal Friction <br />T = 32 deg <br />Cohesion <br />coh = 0.0 psf <br />Moist Unit Weight <br />gamma = 125 pcf <br />Retained Zone <br />Angle of Internal Friction <br />tp = 32 deg <br />Cohesion <br />coh = 0.0 psf <br />Moist Unit Weight <br />gamma = 125 pcf <br />Foundation <br />Angle of Internal Friction <br />9 = 34 deg <br />Cohesion <br />coh = 0.0 psf <br />Moist Unit Weight <br />gamma = 130 pcf <br />Note: Calculations and quantities are for PRELIMINARY ANALYTICAL USE ONLY and MUST NOT be used for final <br />n or construction without the independent review, verification, and approval by a qualified professional engineer. <br />CornerStone Analysis and Design 5.0.19309 O3�IT <br />