Laserfiche WebLink
- � <br /> - � . . <br /> .� ,.� ;.'.:`:: : i�:::,'::.- . , <br /> � NOTE: CONTINUE SHEAR PANEL � " ' � <br /> ;��;.. <br /> �`�;::::;':;: :`r:.;::' ;':':;:i�:: <br /> _ TO THE NEAREST CORNER SIDING OVER � 1 I - ' '. '� > �' ' . <br /> ., �<.;<::: �.'� ;;:°:'::,:::`::;::_ <br /> SIDING OVER 5 8 � ;' "�,,': , ::: .;:, ; <br /> � PLYWOOD SHTG. I � D2 ;y,. ��,,., ::';°:':�::::�>< . <br /> � � SIDWG OVER I °'';:�� ,��' '`'i;,:,>:; <br /> TYPE X GYPSUM SHEATHING I ,�, . : � ,:;�.;<;:::`;'_`;;;;;; <br /> 0 . � 9 '>::� ; .::��;° � .. �1::.;<;;;�<,>:,:..:;: <br /> » , f OVER SHEAR PANEL WHERE I SB SHTG ON � , �;;;,;;; ,,,;, ,;a;. ,,,.,., ,,; <br /> SIDING OVER , „ I ':,:;��{: , ;;,<, <br /> 5 8 TYPE X �.::::: �: „ <br /> � i � <br /> D1 �,.�:;`:::;::_<::.::; <br /> INDICATED ON SHEAR P A 2x6 S AT 16 O.C. I <br /> L NS FLOOR FRAMING >. �.�:<:::.:::::..::� <br /> I ..:...:::.:..:.:.:. <br /> ,<.,:;.:::;:. <br /> G SU 1 x6 P.T. SPACER :` �::: �r�":<: � `;-_ � <br /> 1P M SHEATHING I lx P.T. FURR STRIPS „ �, ,:�.., �;..:;. -�::. .:..:..::::.::...:...:::::: <br /> I � ;s, �� ;.;; ,..;:,: .,� ;:: " ;;;;,;,;;;;;,;;,:: <br /> z s » 3/a FLOOR h GWB I '`�:��;' .�1,.; ,.9 . �.:. <br /> ------------ � ' SHEATHING � � '2 , ,. �' � � � �a� ` . . <br /> I ' �d- <.. ..,.....::... ...:..< }��..,:: `, �}' <br /> � <br /> � � <br /> --------------- ------ _� ' , ;:. <br /> DDED I a �a <br /> INTO STEM WALL 1 �, <br /> , <br /> �....:.,:.:.:.:;..: <br /> . . I � 1x6 PT PLATE � \ ,>, . �, ;�;, , ;::, �� <br /> ,�;,. <br /> . . � N `�,;; � '<?;^s;;-;:. <br /> rs • I � '�� rt ��' ' �j <br /> � 1/2 P.T. PLYWOOD � j° a 2 2 I � <br /> i <br /> 2 a -P.T. PLATE � � ` ' ' <br /> 2 � � 1 0 R IN U A 0 PROVIDE VAPOR � z �;a ' !.� � �` � ; � � �� ��' �: ' . . <br /> � <br /> . i f BARR z s � ,���...::...:.::.,. ; w::«:..;;:.�: `. . <br /> IER HERE � � <br /> I �F:,:; <br /> <,£:,;: <br /> .� ;:�:,;::, <br /> >;:�� <br /> i <br /> � �:.��>:'�; - <br /> �� <br /> �:�� <�>��:�`. <br /> ����:,:�.. .�,��::.�;�:,� <br /> � UNLESS FLOOR � MAIN oo la =='�'� .�,,;_ <br /> Q ' .':`:,�: ;i,3:."iiv`�: . <br /> Q <br /> ..a'� <br /> �:; <br /> <�i�•'.<' <br /> :'�.,E�'<�... <br /> �., <br /> O ;;�i:. <br /> I O <br /> 1 cn — — <br /> '+.iJi1�i "';!'�! <br /> �A� <br /> �.4.. '�.�.. <br /> I - . <br /> � <br /> FkC <br /> Z .a�� t'��i" - <br /> GARA �— <br /> S <br /> GE <br /> NEAT IN — — <br /> H G IS A <br /> w <br /> a <br /> �,. <br /> � —' �d. — — — ��� �i' �,i:' :i., " �i: , <br /> � �� �� � �— ' :;�.r;�� ".>:�.::t.:r��;,,'�'„ •.a:,: Y;:F;,:.:.r�::._:.:;:.:, <br /> � � � — .:�a> :;r>. `^`�s::::4:>; ""s':;,. • <br /> � RA D BA f . FLOOR _ �: ;�: �, . . <br /> TE RR ER <br /> ��';C,, '#t.t'��';�� '�'�' ;<;:; <br /> ,o z ��: ?:'�:� �';;:�r:.:,�1.. <br /> ,o L_ a _►� 1 z y.�.. ;�::�`�.:: <br /> . �..4::':i�.:.�.:::.}ii::i ::il.'!;.1�h:u�:'i <br /> -- -- -- -- -- -- -- -- -- -- -- -- -- -- SEE NOTES TNIS � � ` <br /> z a SHEET. FlNISH GRADE . � � I ° � � � }K€��.1�+��t��r�s�t� �fit��€,����1SG��'�j � <br /> � a . - - - a -�� �.a° ao �P �����9 7T��"�,��;4�J� 12��' d <br /> � I�I—I I�—I� I—) I I—� D 4 a • II I � r°'X��� y�Iv`Y�t�i'4`?1T1k�,nit��CF��i�11��'�f�(�S� <br /> . . . , , d ' d : r-'::. ; <br /> FINISH GRADE � -III=III—III—III <br /> 5/8" TYPE 'X' GWB = � _ — a (CRAWL SPACE -)I I=I I I—I <br /> _ a � <br /> „ — __— (=I I(—I I I a D'RAINRF. d � _ .�.a <br /> OVER 2x SruDS AT 16 OC II I—I I I—I I I—I II—I � a <br /> . m:� a :. <br /> aa , VAPOR BARRIER 5052 REGISTERED <br /> 1-H�. Fir� Barri�� l�all -1 I I-1 I I—I I i-1 I I a =� i i=„i_, �� ARCHITECT <br /> -I{I—I I I—I � � <br /> I=I I (_� I( SEE S SNEETS FOR I I= <br /> � H�. C�/�i F6�� NO. IIVP�'Q� STRUCTURAL INFORMATlON � ' <br /> Exterior Side - One la er 5/8� T e x ��E� ��LL FURR SHEATHI�G FLO�R C��ER CRAVVl�L SPACE EXTERIOR GARAGE �/'ALL CRA'1�lLSPACE �C�O1"IN� ROBERT E. WEIBLE ; <br /> y yp gypsum sheathing, 48` wide, STATE OF WASHINGTON 'r � <br /> applied parailel to studs with galvanized roofing nails, 1 3/4' long, � � � <br /> 0.120' shank, 7/16" or 1/2' heads, 7" o.c. in field, 4" o.c. perimeter, ' � <br /> Joints of gypsum sheathing may be left untreated. Exterior cladding 1-1/2" = 1'-0" SEC��ON 1-1/2" = 1'-�» SECTION 1-1/2" = 1'-�" . SEC��O� 3/4'° = 1'-0" SE�T�oN <br /> to be attached through sheathing to studs. Wallboard and sheathing <br /> nailed to top and bottom plates at 7' o.c. � <br /> Interior Side - One layer 5/8" type X gypsum wailboard or water resistan# � � <br /> backer board or veneer base applied parallel with or at right angfes to �, � <br /> 2 L <br /> 2 x 4 wood studs, 24' o.c. with bd coated nails 1 7/8' long, 0.0915° shank, D2 N :� <br /> 1/4' heads, 7' o.c. (LOAD-BEARING> � � <br /> � 9 � . � <br /> GARAGE ' D1 FLOOR FRAMING a <br /> _ 17 1-HR. EXTERI�R V�ALL � - - � . � <br /> _ � <br /> 3" = 1'-0" 3/4" FLOOR SHEATHING PAVING - q 2 � > � �j a' <br /> � PLAN CONC. SLOPE AWAY 1x6 PT PLATE N � - � <br /> � N <br /> -- . � SLAB " • <br /> _ „ <br /> � = <br /> ��e .� <br /> a. • a ° aa, . Q. :�. z aa I� . � <br /> d a � — + _ , °- ;e� � <br /> —I I �d � <br /> s W �(� � I . � � �' <br /> I�SULATI�N Al�l� ENERGY �0��� . MIN. ; i � aQ � � . <br /> :...: .....:. ...: . ...... �...,......... ... .. .:. . ..:: . ...:..:.... ._... . . � . . ... ...:......,. .:. <br /> . °..a °� -II � N <br /> insu ation - Generai V�/indows: a . � � �, . <br /> All insulation materials shall be instailed according to the Glazing U-values shall be determined in accordance with NFRC • a ' ° ° j � . , � •; . <br /> ` ° a . � o <br /> manufacturer's instructions to achieve proper densities, and maintain 100-91 �8" GWB SEE 15/S6.0 FOR =� ° " �r °� <br /> uniform R-values. Substantial contact of the insulation with the Windows and SGD shall be doubie glazed vinyl type with the � STRUCTURAL (NFO. o� °a� � . VAPOR BARRIER Z O � � <br /> surface being insulated is required. U-values indicated on unit floor plans. 11/ T,11 � � _ �, <br /> S E E S S H E E T S F O R -)I I= �I-� <br /> Insulation shall be installed in a manner which will permit STRUCTURAL INFORMATION ��_ <br /> ins pection of the ma n uf a c t u r e r's R-v a l u e i d e n t i f i c a t i o n m a r k. Roof/Ceil��t�s: CI\� LSPA�E (-O� I�� /`� -o <br /> Where required, insulation shall be instafled with clearances Roof/Ceiling insulation: Open-Blown or poured loose fill �, � � <br /> according to manufacturer's specifications. Insulation shall be insulation may be used in attic spaces where the slope of the ceiling is YPICAL UPPER FLOOR �/"ll\/�VC APRON GARAGE SLA� o P <br /> installed so that required ventilation is unobstructed. For biown or n o t m o r e t h a n t h r e e f e e t i n t w e l v e a r t d t h e r e i s a t l e a s t t h i r t y i n c h e s o 6 � � �� <br /> poure d loose fi l l insu la tion c learances s ha l l be maintained through of clear distance from the to of the bottom chord of the truss or � <br /> �� . „ „ , ,� �, � �. o <br /> instailation of a permanent retainer. p 1-1/2 = 1 -0 E TI N 3/4 = 1 -0 SECTION 3/4 = 1 -0 SECTION � <br /> For specific R-Values, see insulation note on unit floor plans. ceiling joist to the underside of the sheathing at the roof ridge. When <br /> eave vents are instailed, baffling of the vent openings shall be � . <br /> Crdwl SpaCes provided so as to deflect the incoming air above the surface of the . <br /> � Crawl space foundation vents shail be placed so that the top of the insulation. Baffles shall be rigid material, resistant to wind driven I SEE DETAIL 4/D1 � "i•� <br /> vent is below the lower surface of the floor insulation. When moisture. When feasible, the baffles shall be instailed from the top of CONCRETE SLAB D2 � FOR DOOR THRESHOLD � � � � <br /> foundation vents are not laced so that the to of the vent is below the the outside of the exterior wall extending inward to a point six , <br /> p P ' � AT PORCH AND � �° <br /> lower surface of the floor insulation, a permanently attached baffle inches vertically above the height of noncompressed insulation, and SEE 4/A8 PATIO, SEE � 1x6 PT 9 � T <br /> shall be installed at an angle of thirty degrees from horizontal, to twelve inches vertically above loose fill insulation. FOR WOOD FOUNDATION PLAN � PLATE a1 FLOOR FRAMING ■� - o <br /> divert air flow below the lower surface ofi the floor insulation. Where the ventilation space above the insulation is less than an COLUMN � _��� � � <br /> 3/4" FLOOR SHEATHING <br /> A ground cover of six mil (0.006 inch thick) black polyethylene or average of tweive inches roof ceiling assemblies shall be provided with HOUSE INTERIOR '' � <br /> approved equal shall be laid over the ground within crawl spaces. The a vapor retarder. Faced batt insulation where used as a vapor retarder � °i i o :, <br /> shall be face stapled. FINISH FLOOR <br /> ground cover shall be overlapped twelve inches minimum cat the joints and _—___— __—_—_ _ � °� ad A . <br /> shali extend to foundation wall. Vapor re tar ders s hall not be required in roof/ceiling assemblies HEIGHT INDICATED �i�=�Ti�i�Ti-L1=1=�� a L� �° ? <br /> where the ventilation space above the insulation averages twelve inches �T-, ���r��������j :.I � <br /> F���� or grea ter. � L .� N '!�I �', �. PROVIDE %2" AIR SPACE � � � <br /> Vapor retarders shall be instailed on the warm side of the ° a ,. � � . � -� 1. . BETWEEN CONCRETE o � <br /> Fioor insulation shali be installed in a permanent manner in - �� =1�� aa AND PONY WALL � <br /> insulation. CO � �I I H I 1=i I 1=i I I=' I i=l i I ' � �r °` <br /> substantial contact with the surface being insulated. Insulation � � � ll-T�IIHII�-i''-" _� � � z PONY WALL AT ° <br /> supports shali be installed so spacing is no more than twenty-four --a- Ilf_Trl-IIH11�=� " < 1;.� � BEARING CONDITION <br /> inches on eenter. HAND SACK � : a�J.,..��-"T- a�.a � <br /> Floors separating conditioned space from unconditioned space shall Recessed Lightin� Fixtures WALL FACE ' " <br /> .. .�.... ..:.. .... . ... .. ,......... .. .. . .:. .....:.. „�..:....a._., . ., : 4�� PE � � <br /> When installed in the buildin envelo e recessed li htin fixtures " �� �"� ��� 3�/2" .� � s''a <br /> RF. ° � <br /> - have a vapor retarder installed. Vapor retarder shali be installed on g p � g g DRAIN ' � � <br /> -- the warm side of the insulation. The vapor retarder shail have a one shall meet the requirements specified in Section 402.4.5 WSEC 2015: a. a . .q ' ' o � <br /> Recessed luminaires installed in the building thermal e�velope shall be „ , , GARAGE - - �- - - - - � < � a e 6" NOTE: EXTEND FOOTING � Z <br /> � perm dry cup rating or less (i.e. four mil. polyethylene or kraft faced �/s T1PE X GWB .�1-111,�111-111-I �111=Tl=111 a . .a� � � a 6" AT PONY WALL `n N <br /> material) The floor sheathin ma be used as the va or retarder if Type IC-rated and certified under ASTM E283 as having an air leakage FIRETAPE ONLY �.-��-,��=Lf�ll�1l--�I I=1 a a. . < Q :, . <br /> 9 Y P I i i-i I-I I i-I I I-I I . <br /> rated (and so stam ed? at one erm (max.) Otherwise lace va or rate not more than 2.0 cfm when tested at a 1.57 sf ressure differential --��_�-��rr-���--� ° SEE S SHEETS FOR ° _�"i_ -i�- i �_i�-; . <br /> p p STRUCTURAL lNFORMATION -II-I I �'-"' <br /> p p P p and shali have a labei attached showing compliance with this test method. 11%8" T,1I ��11 VAPOR BARRIER <br /> retarder on top of joists before plocing sheathing. ���_ � <br /> All recessed luminaires shall be sealed with a gasket or caulk between the C � LSPA�E F���I�� . <br /> housing and the interior wall or ceiling covering. � <br /> Exterior Wails ^� / p <br /> Ail wall insulation shall fill the entire cavity. Exterior wall FLOO R �.,! V Eti,. G/�RAGE PO RC E DGE D ET�I L AT H�G H FC3lJ N D�TI O N WALL �r°� � <br /> cavities isolated during framing shall be fully insulated to the levels 3 • - <br /> 1 7 <br /> of the surrounding walis. All faced insulation shal( be face stapled to V!/�ter I-��atet'S 1-1/2" = 1'-O» SECTION 1" = 1'-0" 3/4" = 1'-0" SEC��ON � " <br /> avoid compression. All water heaters shall meet the requirements of the 1987 National � <br /> Walls separating conditioned space from unconditioned space shall Appliance Energy Conservation Act and be so labeled. � � <br /> have ca vapor retarder instailed. Faced batt insulafiion shall be face All electric water heaters in unheated spaces or on concrete floors EXTER►OR � � <br /> stapled. Vapor retarder shail be installed on the warm side of fihe shall be placed on an incompressible, insulated surface with a minimum • � <br /> insulation. thermai resistance of R-10. uNIT � � � � �� <br /> �� � � � � <br /> Water heaters shall be equipped with automa#ic temperature controls I � p � <br /> Air Leakage capable of adjustment from the lowest to the highest acceptabfe � uN�T � � („� � <br /> These air leakage notes apply to those locations separating outdoor temperature settings for the intended use. Temperature setting range FULLY INSULATE CORNER � FLASHING FROM � � �+ � . <br /> � ambient conditions from interior spaces that are heated or mechanicaily shail be set to 120 F. or 49 C. UNDER THRESHOLD '- � t0? . <br /> cooled. A se arate switch shall be rovided to ermit turnin off fihe � DOWN ACROSS THRESHOLD AT ENTRY � � , ; <br /> p p p g � SHEATHING DOOR � � � <br /> Exterior joints around windows and door frames, openings between energy suppiied to electric water heaters. A separate valve shall be STUDS C� � ' � <br /> walls and foundation, between walis and roof and wall panels; openings provided to permit turning off the energy supplied to the main burnerts) 16" OC 2x NAILER j �/y '� � . <br /> at penetrations of utility services through walis, floors and roofs; and of ali other types of service water heater systems. .:� 2 6 � 2x4 TRIM OVER FIN. FL. ___ _ •� ,F '� <br /> all other openings in the building envelope for all occupancies shali be � � '� � •����� �� � ��� '��' '° ��� �� �•� �� ���:� �� -��'��.�� �� ° OSB SHEATHiNG � i � <br /> j Z s �, <br /> sealed, caulked, gasketed, or weatherstripped to limit air leakage. Other � - � ; � � <br /> � 2 2 � SEALANT � L <br /> exterior joints and seams shall be similarly treated, or taped, or covered � BELOW SHTG. � � � <br /> with moisture vapor permable housewrap. � a a � I T � � � :, . <br /> Openings that are required to be fire resistive are exempt from air R 21 I � .v <br /> leakage restrictions. T E L UL TI N i .. a. �a � ° � . � <br /> �, . . o <br /> � . <br /> — "-1� I=I I I-I I I � � � � • <br /> Doors 6 6 �i►=i i►=1 I 1= z 4 � � . �. <br /> CONCRETE I=I I I ° e z a 1 6 T P ATE � <br /> ,. ; <br /> AI exterior doors or doors serving as access to an enclosed PORCH . ° � o f ` " <br /> unheated area shall be weatherstripped to limit leakage around their _______________________________ � � W � � <br /> perimeter when in a closed position. � . <br /> The thermal transfer characteristics of insulated doors shali be EXTERIOR o <br /> determined per NFRC 100-91, . � . <br /> Q . <br /> _ 1'PlCAL EX ERIOR CORNE � TH�ESHOLD DETAIL � '°" "°.: ��-3� � <br /> 1� � � Sheet No.: �' � <br /> _ 3" = 1'-0" P�1N 1-1/2" = 1'-0" �J�CT�oN N � . <br /> ._ � � � <br /> � <br /> Sheet Order: � � � . ` <br /> _ <br /> r � � <br />