Laserfiche WebLink
� _ i . - .. ,1 - . .. <br /> _ - C ! � <br /> "AFd � _ <br /> _ - ��� � �;fi . <br /> ! � '. & <br /> 5 � <br /> ��: � '' � <br /> 3 <br /> ' ����,� � I � <br /> � ` �a <br /> 1 � � � <br /> � �� � i � � <br /> °�, i �' f <br /> �� �, i <br /> • � "� , 'se K, <br /> ' �� ,� �� <br /> � '� <br /> a <br /> � <br /> , <br /> 5 3 , , r <br /> � ` '� + <br /> , ;, �' � �; <br /> � � <br /> e r � � <br /> f � <br /> + <br /> ' ���'i� � `N'�"�<� � � � ��,� <br /> : �p �j� i <br /> � p`k'� � E\t,�,'�" 9 �J;,.#d 1 � �,� �4, <br /> rY , > <br /> '�� t ;Y.,. � "�� <br /> >.3, <br /> � k <br /> � `5 <br /> �'L }N �r' '� i <br /> ;I;<: � ':.h:'�`v'`jr�:!S:;:i.%::�A:`,�J,1`.h,::r':�::.';''�::::'(:�';��:i:�:,¢... <br /> E'd:>:iir't:..,,.).: ;�:�e;:,.:.r�� <br /> ,:��;;,t:,. <br /> ii::'a;<'':�'�;>.i;, <br /> C. <br /> %i�!'.t;�'��' . <br /> �:.,r:.. <br /> 'i:�•:r;.. ;$. .£S�`::>�:tf"`':°,3z':;.�#:�r��:;;,�:;�+;;: <br /> ,,.;w,��,,Y.,.�„�„$,�.,.>•n,: �,�?;;,�:# . cg�. ;;.,.�.�i•;; <br /> `i�..,.,,, i�,^,�.,��'•�'.'i;':�::xq:....Rq:i;kp•:i?:,3z5;,.:..,,;•�)'�n <br /> �fi3�:;i�i'f4ti�', . ^1,;,::.':.`.:.e.;�.,;,:'��;';.i <br /> ��i�'�f�dl`7€���#�S�tll3Q�t�C�� z��Q��, : <br /> 4�$ ��.�r�.�'y�����;�;1,3�„ `���5;�,u,5,,�;i:��f$.�,, <br /> ' ;,;V:"'��,'.f;�-K'x�':�".b'.'�'eR;jlr4,='t .��.f�,E;-;.�.¢:�;,- �iNYYpl�k;:i"'ti::' , <br /> '"":��:��'�,:�V'���?����1����t��'E t3Y;t,$i;:t�,iC�•`,';:� <br /> ' ,��: A � ;S, <br /> v4.., .f, :`:h; t x,.� <br /> 30'-0" 5052 <br /> � REGISTERED <br /> t 4'-0" 9" 15'-3" ARCHITECT <br /> � A <br /> A 30'-0�. A7 � <br /> A7 ROBERT E. N1EIB�E <br /> 3`-5%2" 5'-3�4" 5'-3�q.�' 7'-0" 5'-0" 4'-0" <br /> 14'-0" 16'-0" STATE OF WASHINGTON <br /> i � <br /> ( I i i D2 ROOF ABOVE 6pOST/BASE � • <br /> ' LOW ROOF ' � <br /> � <br /> I � , 7'-0" 7'-0„ ,- -�•_�----�'-0"-------5r 6„----- -� 9,,, s �; <br /> I 12 °' <br /> i i 1 � i i � � � <br /> 3-6 3r6 SH 2-0 I3-6 SH + I �� - I - I I � �' <br /> SAFETY(GLAZING SAFE GLAZING � � , 5 0 5 0 SL I I •� <br /> • � i i � ; ..'. .�. r--•I•�• I 1-a��� j ia � <br /> ........ .............. .......................� ' .. .............. ............... <br /> ; ; � " I <br /> ' : � ' r- _ ' � ---� O � DW'- I ' � , � I � C �, <br /> , , � <br /> _ , ; 0 3 x 5 `�' 48x3 � d. �.� ( I `" ; j j j ° � 5-0�5-0 SL 5-0 5-�-0 SL I `V •� v <br /> = i DROP IN 7UB � � i.... .......... ......... . ......... ; I � . '� z <br /> , .. . .... ¢ ...... .. ...... <br /> _ : SHOWER ... -6 4- SL -6 4-0 SL ; � SAFETY GLAZING � - <br /> • • � � � � v+' <br /> - _ : 12 EGRESS � • j - KItCh�Il � � °' <br /> . <br /> � i _ <br /> � ° � 2X6 WALI � <br /> � A 8 D2 � � c� �j � � " ° <br /> Q l�l. �ath q.�_�3�4„ (� � d' _ �� --- I -o <br /> � <br /> � <br /> 24" TB �r� � <br /> 1'-0�� cc �N �n <br /> I � � <br /> O � ° � O , N � � <br /> s N � <br /> I � � � j i , n � N .��, <br /> TP N � � � '� � 2 �� ' � � -$ DIRECT VENT ' <br /> � � � � � i 3 � ; 1'-0" � GAS APPLIANCE ��� o <br /> N <br /> • a N j = ' � � ; �- "FIREPLACE" � � �� „ s <br /> �D y,� 5'-1 0" 2�. 3,_6„ � � - � � ' � � � � ^ � o D1 o Q .� <br /> � Master Bedroorn � ' -------------� � :;� : ,0 1 � T <br /> �T � ,o�� EA. � , ; , �, ; ---------------, � Great Room `� � <br /> � D3 <br /> ' ` 13�_q.�2� 7'-9" -4 HC4� 3�-��» � ^ j � �J � o v <br /> av i 9 � D � � <br /> SECOND N 16 15 14 13 12 1i 10 9 =N i 2'-5" 5�-�Y2�� 10'-10" D3 4�"3" 5'-0" <br /> �Q�� i � : INSULATE FLOOR �� <br /> r <br /> M DN � ' � ��'�C� �-� i PANTRY � „ � x OVER CRAWLSPACE ,� � • <br /> � : : <br /> "' : �------------------ BIFOLD ? 3 ; 3'-5%" CAB 10'-1" 5 2 � � �i N ° co <br /> U <br /> 1Yz"� HANDRAIL AT - , ; _ _ ; D3 ? "' `�' _ r <br /> 34" TO 38" ABOVE NOSING 7 : ; "N 5 SH. �i -� �i ' ___ _____� _T-______ <br /> . : x .. ......... . . .......... � =N �n �' O� <br /> 1%2" BETWEEN g o `V `" `� EDGE OF SOFFIT � 18"x24" CRAWL `V o o � <br /> d <br /> HANDRAIL & WALL � w � � N : (+7'-10" A.F.F � SPACE ACCESS e N <br /> � � <br /> . o o ° o tn ' � <br /> o = TYP.) <br /> � `- � � Q � (L ^ L'"N O d�- �..1 � r-�_ _F'� � � � �'Q Q <br /> TOP OF WALL � � <br /> HA�LF WALL 3 "' � "' � � _m j � � • �� �;, ;� AT +39" A.F.F. I�•) � ,i �'�G�I � I �j I I I �� N <br /> +39 ABOVE 2 x o � o � � i �N I..1 d- � I � I � 1 I u� <br /> B N i cn � �, I �,, � B B .� D161�C1� ���� ; `� ,�__�.� � � 4x POST � B T <br /> NOSING TYP. � A7 �,- - Bedroorn 2 � I ��.�- A7 A7 I::i �o AB VE M� A7 ,� o <br /> � o � � I v�i � � �..1 � v�i = o � <br /> FLOOR uP � � W � � ,-- -, - � � :.� 5'-gY2" � o <br /> ABOVE 3�-6� - � �22"x3 " � � �. � <br /> io 0 <br /> I I I <br /> �, arn i � ^ �' i. i <br /> �j I ,_ n ._ 1 � �_ ^ , b � IACCE S I lndry. DRYER 3 � � I 1 2x6 WALL N p � <br /> �n 3 ��2 5 3�2 2 ��2 2-4 I I i� . � � o <br /> 16 EQUAL RISERS = 10�-�5I8" FIRST � �- �' � � � ' � <br /> MAX. RISER HE(GHT: 7�a„ FLOOR � 2-6 HC �N N � � � 3 �= 4-2� � -��7��� � LOOR a �, <br /> MIN. TREAD WIDTH: 10 � N d- a, � <br /> o WASHER , ,n D2 BOVE � ° m <br /> � • - — � 2-8 HC : : `� �,�, \ _ � <br /> R O <br /> . �5' TUB 5 SH. o S ;� �n : 2x6 � .. �........N.....;.. �.......... 45' � � 3 "� <br /> o : °� & 5 SH. � � -� : : WALL � ... .:.:.�,:............:�..�.......... ^ UP� 1 x °p a <br /> � � ....�..�.. e.. <br /> ,i �' N SHWR N- N : : .... .... .... .... .... .... . . �.....�j.... .�.�i�.� _.�.�.•.� . i 3'-9 " .- <br /> � =z � 7p yy °° 9,_1� » 2-6 HC > >� , n ... ..... .........�...:�..�... .:.. .� �2 p2 i <br /> ' PV1�`Ut°:�� .�........ . <br /> � � '� �i.. �'Q �•0 9 6 -11 4-5 :. ..�. .. .� ...� ........,...�.R.�.... � ..... ....... � �' � . HAL WALL � <br /> � � o� �p �, _ ..�..�.�. : . ...... .... �+.... . 2x6 WALL TYP. <br /> • ............. . . <br /> . . . . <br /> �. � . . . . ...... ....... <br /> N � ............. ........ .... �. ; ... ..... ... .•_�.::�::�.•.•.•,�.•.,..:���� +39" ABOVE c, <br /> / » , » _ ......................... T- <br /> 1 4 -1 -0 � co W B1t� RETURN ° 5' -.� �'' ........... .....''�� -CLOS G ''`'N <br /> .. ... ...... <br /> _ _ � 6 45• N -� �WK:............................-�:�:��:�: '.. ...................... . �.�2-8 INSU NOSING TYP. z <br /> ........ . <br /> _ � �� e � AIR 2'-4" I o � 4 . » 2x6 WALL _ �............. ....•..., \ ' � o , <br /> SOFFIT CEILING � o <br /> 'c.� � , cn i � TO +8 -1 A.F.F. o - <br /> _ _ � � � c � tn ___ � ' � " 2 > n �.'.'.'..'• ,E... . \ . En� (D� � !� <br /> - � �r � � W a r� 8-11� 9-4�4 i� j...:.:....3:..•$�q..... \ N J I a U <br /> f i �....�.•..•�.. e 'l <br /> - � � � � � ' � Bedroorn 4 � � � � ----- _ _ ' .�� s - <br /> � � v <br /> �/'f <br /> 2-6 H�W c� W �n o t_' `.'.�.'.'.'.'.'.'.'.'.'.'. : � Z ; <br /> � j � `� � � 42"x12" WOOD TREAD � 4,_p� � 4 ,� , ; 12 � T <br /> N O T E S . � m ___ �� � MAX. RISER 7�/a S FETY D1 � 9 D2 <br /> � : S 8c P 2-6 HCW ; I a � D2 GL ZING ' <br /> � �. - � � ------------- � I i : � SOFFIT CEILlNG �........... ... � .....? <br /> . FRAMING: 2x6 s AT 16 OC EXTERIOR WALLS INSULATE AND WEATHER STRIP ALL ATTIC ,i ; �' I 'r' ;o� ------------------------- : 1 `� TO +8'-1" A.F.F. "' <br /> 2x4's AT 16" OC INTERIQR WALLS ACCESS HATCHES. PROVIDE A MINIMUM OF N 6 �,�, i i N WALL BELQW D2 2x6 WALL 1-0 ,5-10 F I � <br /> UNLESS NOTED OTHERWISE. 30" �F HEAD ROOM ABOVE ALL HATCHES. ; 6-0 BIPASS , T1P. I , I <br /> . <br /> CONCEALED SPACES SHALL BE FIRESTOPPED ALL PLUMBING VENTS SHALL BE LOCATED � 4'-4%2" � 3�_¢�� 3�_g„ c�i c�.� ; z 2�-6 � 2�-9 2-9„ � • <br /> IN BOTH DIRECTIONS AT 10'-0" ON CENTER ON REAR SIDE OF ROOF RIDGE. � � ; °�° G�r��e � <br /> AND AT FLOORS. TYPICAL i i ; .� = I .� <br /> OPENINGS BETWEEN GARAGE AND RESIDENCE 5,_�., � �3�_2�2„ N � <br /> FfREBLOCKING SHALL ALSO BE AT SHAL� BE EQUIPPED WITH SOLID WOOD DOORS o� CEILING FINISH I � <br /> INTERCONNECTIONS BETWEEN VERTICAL NOT LESS THAN 13/" IN THICKNESS, SOLID OR ; { � � 1 IAYER 5/a" TYPE 'X' GWB 36" HIGH RAIL j � � <br /> & HORIZONTAL SPACES, BETWEEN STAIR HONEYCOMB STEEL DOORS NOT LESS THAN � ? � ; FfRE-TAPED � � � <br /> STRINGERS A7 TOP & BOTTOM OF RUN, 1/g THtCK, OR 20-M(N. F(RE-RATED DQORS 's , i = <br /> 3 �� � � INSULATE FLOOR ABOVE � � <br /> AT OPENINGS THROUGH CEfLING & FLOOR PER IRC R302.5.1 i 3 Bonus � � `� I �' , ,� O <br /> AND AT CHIMNEYS & FIREPLACES. : Bed�oor� 3 D2 , o � Porch '�°+ <br /> . � ALL ESCAPE OR RESCUE WINDOWS FROM SLEEPING � � m � j •� � V <br /> A L L B E D R O O M D O O R S S H A L L B E U N D E R C U T R O O M S S H A L L H A V E A M I N I M U M N E T C L E A R ; f N S U L A T E F L O O R , � �. � � <br /> A MINUMUM OF 1/2" ABOVE THE ADJACEfVT OPENING OF 5.7 SQUARE FEET. THE MINIMUM 's ABOVE GARAGE � � D7 Q� <br /> „ ; 1NSULATE FLOOR , <c I �9 <br /> FLOOR COVERING. CLEAR OPENING HEIGHT DIMENSION SHALL BE 24 . ; � � 2x8 FRAMING FOR `�', c� <br /> ABOVE GARAGE � � � � <br /> MINIMUM CLEAR OPENING WIDTH DIMENSION SHALL � EGRESS j INSULATE FLOOR � : ELEC. ENIRANCE I � � <br /> INSULATE AND WEATHER STRfP ALL CRAWL gE 20". SILL HEIGHT SHALL BE NOT MORE THAN <br /> SPACE ACCESS HATCHES. �• �•••••••• •• •••••••••••••� 8 i ABOVE PORCH : � _ 14" CLEAR INSIDE. _____ I � � .�._ � � <br /> 44 ABOVE THE FLOOR. � <br /> 4 6-OI5-0 SL • • <br /> ` 7-0 5-0 DBL SL A8 � � i^ 1 � "' � <br /> GLAZING SHALL CONFORM TO 2015 IRC SECTlON R308. � D3 � : 1 3,1 3,1 3 � � \ FLOOR ABO Ej `F-- ` � <br /> "' � � EGRESS ;�.............. .. .........'S 16-0�7-0 SOHD --------- �` o <br /> -------------------- : . -- > <br /> PROVfDE STREET ADDRESS AT THE FRONT OF EACH LOW,ROOF i.......... „ ,.....; 3-0 � 0 SH � 5 L__________ ___� _____J � � �' � � <br /> UNIT. USE 3" HIGH OR LARGER NUMBERS. ' � LOW I ROOF o . D2 6 5 I 4 (� >+ <br /> 5'-3%2" 5'-3%2" 5'-8�2" 5'-8y2" q.�_p" 4' p» 3'�0" 16'-0" Q� 3'-0" 6'-0" �-0 AS , � <br /> • • • • WALL lNStJLATION <br /> 10'-7" 11'-5" $'-0" _ , ,� �,_��, <br /> . I N S U L A T I O (� STUD WALL HEIGHT 8 -1 STUD WALL HEIGHT 9'-1" �' <br /> INTERIOR ELEVATIONS LOCATED QN SHEET A7 30'-0" ABOVE FIN. FLQOR 30'-0" ABOVE F1N. FLOOR � <br /> WALLS: R21 F16ERGLASS BATTS OR BLANKETS � <br /> FLOORS OVER UNHEATED AREAS - R38 A SEE SHEET A7 FOR TOP q SEE SHEET A7 FOR TOP N <br /> ATTICS ABOVE RDOF CEIL1NG - R49 � SECOND FLOOR PLAIvI A7 OF WINDOW HEIGHT '�' FIRST FLOOR PLAN A� OF WINDOW HEIGHT o <br /> 0 <br /> ., . » 4�,_1'-0" o <br /> SOLID CORE WOOD DOORS TO GARAGE: U=0.20 1/4 =1 -0 �/ ,� <br /> GLAZED ENTRY DOORS: U=0.28 � W <br /> _ INSULATED METAL ENTRY DOORS: U=0.20 o Job No.: 14-3� <br /> � WINDOWS: ALL WINDOWS SHALL HAVE A U o Sheet No.: <br /> FACTOR OF 0.28 OR BETTER N <br /> - � <br /> . _ � <br /> . <br />