<br /> FLDOR PL..�N NOTES:
<br /> "2X6 H/F#2 EXTERIOR STUD YVALLS @16"O.G. W/DBL TOP PLATE &
<br /> LAPPED 48" MIN.
<br /> �J.� M. G, 'R-21 IN-WALL BATT INSULATION W/VAPOR B?�RRIER.
<br /> o�' v y,-9 '2X4 EXTERIOR STUD i^lALLS� 16" O.G. �GARAGE.
<br /> � .y *REFER TO FRAMING PLANS FOR BEAMS &HEADERS
<br /> Q "REFER TO ELEVATIONS FOR PLATE HEIGHTS.
<br /> 'FIRE BLOGK ALL PLUMBIN6 P�NETRATIONS.
<br /> A ,� 4422s�o t�,ci,� *PROVIDE 50LID BLOGKING OVER BEAMS & BEARING WALLS/
<br /> 8 FcisTER �� R502.7
<br /> II'-10 1/2" �S�4NAL E�G ai50i2018 'ALL HANGERS/STRAPS BY 51MP50N OR EQUAL
<br /> DENOTES 50LID P05T OR DBL STUD P05T LAM'D TOGETHER
<br /> E.�IRES 3-01- 19 WITH 16D(2) FAGH END TH�N 12"O/G STAGGERED U.N.D.
<br /> � _ _ _ _ _ _ _ _ _ _ � 5G 5AFETY GLA55/R308.4
<br /> ' � ( �J 7 *TO BE PROVIDED IN DOOR A55EMBLIES AND WITHIN A 24"ARG OF
<br /> 42,-0„ S1 HINGED EDGE OF A DOOR& GLAZING 15 LE55 THAN 60"A.F.F.
<br /> "WITHIN �NGL05URE5 FOR TUBS & SHOWERS WHEN BOTTOM OF
<br /> � GLA55 15 LE55 THAN 60"ABOYE THE 5T,4NDING SURFAGE.
<br /> 20�-0" 14�-2 1/2" 1'-9 1/2" *WH�N GLAZING 15 LE55 THAN 18"aBOVE THE FLOOR AND HAS
<br /> MORE THAN 9 5Q. FEET OF AREA.
<br /> � 5�-b° 9�-b�� I 5,-0„ 9,-� �/2„ 5,-0„ *GLAZING AT 5T,41RWAY LANDINGS AND WITHIN 60"HORIZ., OF
<br /> SUGH LANDINGS WHEN BOTTOM EDGE OF GLAZING 15 LE55 THAN
<br /> 6 60"ABOYE FINISHED FLOOR.
<br /> DECK A6Y. � _ _ _ _ _ _ _ S1 *SKYLIGHTS TO GOMPLY WITH SEGTION R308.6.
<br /> — — — — — — — — — — —
<br /> GARAGE R30q.2 SEPARATION REQUIRED.
<br /> �;2 O .�Z I 7 GAN?'ABv. .t;L � 'THE 6ARAGE SHALL BE SEPARATED FROM THE RE5IDENGE AND
<br /> �2 60610 � 504 LS S1 1030SH IT5 ATTIG A�REA BY NOT LE55 THRN 1/2-INGH GYPSUM BOARD
<br /> - - - - A�PPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE
<br /> �, ,r; .�� sq..
<br /> , g.a�
<br /> 3112 x 9"PSL ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS
<br /> 4z10 HF2 4x6 HF2 ABOYE BY NOT LE55 THAN 5/8-INGH TYPE X GYPSUM BOARD OR
<br /> � � EQUIVALENT. WHERE THE SEPARATION 15 A FLOOR-GEILING
<br /> � B�TH/ LA�UNDRY A55EMBLY,THE STRUGTURE SUPPORTING THE SEPARi�TION
<br /> �T,2 SHALL AL50 BE PROT�GTED BY NOT LE55 TI-I?�N 1/2-INGH(12.1
<br /> � I �!' O So�FM ,; MM)GYPSUM BOARD OR EQUIVALENT.
<br /> *- � � "'IN 2-STORY GONSTRUGTION,ALL SUPPORTING WALLS & GEILINGS
<br /> I _ _ _ vTo .c p ,STRUGTURAL BEAMS AND P05T5, TO BE OF TYPE"X"G.W.B.
<br /> o ;�� 'A TI6HT FITTING 50LID GORE WOOD DOOR 1-3/8"THIGK OR WITH
<br /> � � U, �, O �� A 20-MIN. FIRE RATING SHALL BE USED BETWEEN HOUSE &
<br /> z -' = 6ARAGE.
<br /> � � �i v F�'tMILY � �'� %��'�=` �� ���`��'%� � `DUGTS IN THE GARAGE AND DUGTS PENETRATING THE YyALLS
<br /> � INT BRG WALL OR GEILINGS 5EPARATING THE DWELLING �ROM THE GARAGE
<br /> I O �*. SHALL BE GONSTRUGTED OF A MINIMUM NO. 26 GAGE SHEET
<br /> �' y.�{� STEEL OR OTHER?�PPROVED MATERIAL AND SHA�LL HAVE NO
<br /> � o O �g g OPENINGS INTO THE GARAGE.
<br /> - I � � �'� 2 FURNAGE/WATER H�ATER
<br /> v 2 �—BOLLARD *STE�L HWT TO GOMPLY WITH ASHRAE 90A-80 & LABELED. TO 8E
<br /> � I EQUIPPED WITH A PRE55URE & RELIEF VALYE W/3/4" GOPPER OR
<br /> a' w GALVANIZED STEEL OVERFLOW VENT PIPE PLUMBED TO OUT5IDE
<br /> � — �( & SEISMIG STRAPS FOR HORIZ. FORGES TOP AND BOTTOM, SHALL
<br /> I ,2 BE PROVIDED WITHIN THE UPPER AND LOWER 1/3RD OF IT5 i
<br /> _ 3 _ VERTIGAL DIMENSION. THE LOWER STRAP SHALL NOT BE LE55 �
<br /> Q � �� � �� � ,� � ,� Q THAN 4"ABOVE ITS GONTROLS.
<br /> � 8-0 5-0 3-1 3-10 1/� =, 4_2X6 O1 4-2x6 � "INSULATE HWT WITH R-16 lNRAP&TO 51T ON R-10 RIGID WHEN ',
<br /> INT.BRGWALL F - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ PLAGEDONGONGRETE.
<br /> -.- - . �68= �68- - - - - _ ., - - - - - - - - - - - - - - ;� —�- - - - - - - - - - - - - - - - - - HVAGABOVEFLOORDUGTINGTOBE26GA.
<br /> � — INT.BRG WALL 4x6 HF2 4x6 HF2 � 4x6 HF2 ; . . "HVAG UNIT TO GOMPLY WITH 2O09 W.S.E.G.& LABELED WITH A
<br /> n PERFORMANG� RATING.
<br /> � � 6068 �SDJ � ,,�J'�• ' *PILOTS, BURNERS, SWITGHES TO BE 18"AFF
<br /> — = G�R1�GE *GOMBUSTION AIR REQUIREMENTS SHALL GONFORM TO THE '
<br /> REQUIREMENTS OF GHAPTER l OF THE INTERNATIONAL
<br /> � � � � N MEGHANIGAL GODE (IMG). � �
<br /> � � � � 'PROTEGT MEGHaNIGAL FROM IMPAGT W/ BOLLARD WHEN
<br /> � '` � > �
<br /> LOGATED IN GARAGE.
<br /> I ; � � � � - - - - - - - � � - - - - - - - � P � 3 LANDINGSPERR311.3
<br /> d ' � STAIR WELL ILLUMINATION PER R303.6
<br /> � � � � � � � � � '4'
<br /> z � ' "'
<br /> _ `�� , —
<br /> o � BDR 4 0 ; : 4 . I I I I . .__ ___- __
<br /> � L _ a o '�
<br /> � I I I I � �T U B, SH O W ER, W/G:
<br /> SHOWER TO GOMPLY WITH R 301.2
<br /> PONYWALL BELOW LANDINCs O3 ; I I I I WATERPROOF B?�GKING +72"MIN.ABOYE DRAIN INLET.Rl02.4.2 I
<br /> ��r � � � � PRE55URE BALANGE OR THERM05TATIG MIXING V?�LYES SHALL
<br /> O � ;[ �� I I I I BE PROYIDED FOR SHOWERS AND TUB/SHOWER GOMBO Q 2.5 I
<br /> 4x8 HF2 _ r: 5-118x12 GLB CONT.PER 11S-1 � � � - 5-118x12 GLB CONT.PER 11S-1 'PROVIDE SAF�TY GLA55 ON ALL ENGL05URE5.
<br /> o GPM MAX. I,
<br /> `u`�' -'� -° ALL PLUMBING FAUGETS TO HAVE A 2.2 GPM FLOW RESTRIGTOR.
<br /> � ka... � ',c.�. ..." . �h; ..r`=�"-
<br /> ��, \SW-2 �� �5 SW-2 '�' RSW 5 SO10 �� � SOlO 5 w � W/G TO USE 1.6 GALLON MAX. PER PLUSH.
<br /> \ / S1 - - - - - - - S1 2 T-2 1 EA. END SEGTION P2903.2
<br /> 3068 _ _ � � @ �EGRE55/R310.1-4
<br /> � � — S2 - - � 165 FX �2� T 2 1@EA. END cANt ABv. , ,BEDROOMS SASH 51LL5 UP +44" M,4X. AFF w/MIN. 20"WIDE x 24"
<br /> - ORGH — — — — — — — — — s 'HIGH OPFNING & 5.l S.F.MIN. __ I
<br /> ' S1 Q g� _ _ _
<br /> 6�-10" 5�-8 I/2" � 2�-8 1/2° 3�-3° i�-b�� 2�-0° 8�-3�� ��.b�� g�-3° 2�-0° S PROVIDE PRV PRECEDPD BY Q STRAINER
<br /> 12'-6 1/1" 1'-5 1/2" 21�-0° '
<br /> 41�-0" ALL FRAMING GONNEGTORS REFERENGED 51MP50N OR EQUAL
<br /> ' SMOKE ALf�RMS SHALL BE INSTALLED IN THE
<br /> � so FOLLOWING LOGATIONS: (SEGTION R314.3)
<br /> 1. EAGH SLEEPING ROOM
<br /> 2. OUT5IDE OF EAGH SLEEPING AREA IN THE IMM�DIATE YIGINITY
<br /> OF THE BEDROOMS
<br /> *SMOKE ALARMS SHALL BE INTERGONNEGTED�5 INDIGATED IN
<br /> SEGTION R314.3
<br /> P 'THE POWER SOURGE FOR SMOKE ALARMS SHALL GOMPLY WITH
<br /> SEGTION R314.4
<br /> �'co'i 'GAR60N MONOXIDE ALARMS 5H?�LL AL50 BE INSTALLED
<br /> `�' OUT5IDE OF EAGH SEPAR,4TE SLEEPING AREA IN THE IMMEDIATE
<br /> a VIGINITY OF THE BEDROOMS(SEGTION R315.1, R315.3) �
<br /> 8
<br /> �IYY �F EV��ETT
<br /> R VIEV�E� F�E� ��i���l' o �'
<br /> LOWER FLOOR PLAN �I �� 1 Q��
<br /> 1/4"= 1'-O" �.�
<br /> ISSUED o��os��o,z R.P. SHEET
<br /> /'�� 3922 Slth Ave NE Revised 12110/2013
<br /> j.,�` h /� ("�'� MAryev(Ile, U1a 98210
<br /> 1 il'11'1�„r Offfce: (425)391-1360
<br /> BRt�THERS �ax: (425)334-1399 0 0
<br /> H (� (µ E � WUIUI.NaackBrothera.CORI JRR#12-14 B Not inc.D&S ShYs