Laserfiche WebLink
• <br /> GENERAL NOTES STRUCTURAL NOTES DRAWING ABBREVIATIONS <br /> 1. THE FACILITY IS AN UNOCCUPIED SPECIALIZED MOBILE RADIO FACILITY. GENERAL STRUCTURAL NOTES: AFF ABOVE FINISH FLOOR LF LINEAR FEET <br /> 2. PLANS ARE NOT TO BE SCALED AND ARE INTENDED TO BE A GRAPHIC REPRESENTATION OF THE FINAL 1. WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED,THE DETAIL SHALL BE THE SAME AS AGL ABOVE GRADE LEVEL MAX MAXIMUM <br /> INSTALLATION.THE WORK SHALL INCLUDE FURNISHING MATERIALS,EQUIPMENT,APPURTENANCES AND FOR OTHER SIMILAR WORK. <br /> LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. AWG AMERICAN WIRE GAUGE MECH MECHANICAL <br /> 2. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL NOTES. AC AIR CONDITIONING MFR MANUFACTURER <br /> 3. PRIOR TO THE SUBMISSION OF BIDS,THE CONTRACTOR SHALL VISIT THE JOB SITE AND BE RESPONSIBLE <br /> FOR ALL CONTRACT DOCUMENTS,FIELD CONDITIONS,AND DIMENSIONS AND CONFIRMING THAT THE 3. NO PIPES,DUCTS,SLEEVES,CHASES,ETC.,SHALL BE PLACED IN SLABS,BEAMS,OR WALLS UNLESS q� ADJUSTABLE MGR MANAGER <br /> WORK MAY BE ACCOMPLISHED AS SHOWN PRIOR TO PROCEEDING WITH CONSTRUCTION.ANY SPECIFICALLY SHOWN OR NOTED,NOR SHALL ANY STRUCTURAL MEMBER BE CUT FOR PIPES, <br /> DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER. DUCTS,ETC.,UNLESS OTHERWISE NOTED.CONTRACTOR SHALL OBTAIN PRIOR APPROVAL FOR APPROX APPROXIMATELY MIN MINIMUM <br /> INSTALLATION OF ANY ADDITIONAL PIPES,DUCTS,ETC. <br /> 4. THE CONTRACTOR SHALL RECEIVE,IN WRITING,AUTHORIZATION TO PROCEED BEFORE STARTING WORK. AZ AZIMUTH MISC MISCELLANEOUS <br /> 4. CONTRACTOR AGREES THAT HE SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB <br /> 5. THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT INCLUDING SAFETY BLDG BUILDING MTL METAL <br /> MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE INDICATED OR WHERE LOCAL OF ALL PERSONS AND PROPERTY;THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT CM CONSTRUCTION MANAGER MTZL METALIZE(D) <br /> CODES OR REGULATIONS TAKE PRECEDENCE. BE LIMITED TO NORMAL WORKING HOURS;AND THAT THE CONTRACTOR SHALL DEFEND,INDEMNIFY <br /> AND HOLD VERIZON WIRELESS AND THE ARCHITECT/ENGINEER HARMLESS FROM ANY AND ALL CAB CABINET MW MICROWAVE <br /> 6. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LIABILITY,REAL OR ALLEGED,IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS <br /> CODES,REGULATIONS,AND ORDINANCES.CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH PROJECT,EXCEPTING FOR LIABILITY ARISING FROM THE SOLE NEGLIGENCE OF VERIZON WIRELESS CL CENTERLINE NEC NATIONAL ELECTRICAL CODE <br /> ALL LAWS,ORDINANCES,RULES,REGULATIONS,AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY OR THE ARCHITECT/ENGINEER. <br /> BEARING ON THE PERFORMANCE OF THE WORK.MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE CLG CEILING NIC NOT IN CONTRACT <br /> INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS 5. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE.THEY DO <br /> AND LOCAL AND STATE JURISDICTIONAL CODES,ORDINANCES,AND APPLICABLE REGULATIONS. NOT INDICATE THE METHOD OF CONSTRUCTION.THE CONTRACTOR SHALL PROVIDE ALL MEASURES CLR CLEAR NTS NOT TO SCALE <br /> NECESSARY TO PROTECT THE STRUCTURE,WORKERS,AND PEDESTRIANS DURING CONSTRUCTION. <br /> 7. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING BEST SKILLS AND ATTENTION.THE SUCH MEASURES SHALL INCLUDE,BUT NOT BE LIMITED TO BRACING,SHORING FOR LOADS DUE TO CO COPPER N/A NOT APPLICABLE <br /> CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS, CONSTRUCTION EQUIPMENT,TEMPORARY STRUCTURES,AND PARTIALLY COMPLETED WORK,ETC. CONC CONCRETE OC ON CENTER <br /> TECHNIQUES,SEQUENCES,AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK OBSERVATION VISITS TO THE SITE BY THE ARCHITECT/ENGINEER SHALL NOT INCLUDE INSPECTION CONSTRUCTION DRAWING <br /> UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THE PROJECT MANAGER AND OF SUCH ITEMS. COND CONDUIT OD OUTSIDE DIAMETER <br /> WITH LANDLORD'S AUTHORIZED REPRESENTATIVE. PREPARED FOR: <br /> 6. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. CONST CONSTRUCTION OP OVERHEAD POWER <br /> 8. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A1OBC WITHIN 5 <br /> FEET OF TRAVEL DISTANCE TO ALL PORTIONS OF THE PROJECT AREA DURING CONSTRUCTION. 7. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON FRAMED FLOOR OR ROOF.LOAD CANT CONTINUOUS OT OVERHEAD FIBER verizon" <br /> SHALL NOT EXCEED THE DESIGN LIVE LOAD PER SQUARE FOOT.PROVIDE ADEQUATE <br /> ri <br /> 9. THE CONTRACTOR SHALL PROVIDE SITE FOREMAN WITH A CELLULAR PHONE,AND KEEP SAME ON SITE SHORING/BRACING WHERE STRUCTURE HAS NOT ATTAINED DESIGN STRENGTH. CPM CASCADIA PM OPP OPPOSITE <br /> WHENEVER ANY PERSONNEL ARE ON SITE. <br /> 8. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES D/C DRAFTER/CHECKER PL PROPERTY LINE <br /> 10. DETAILS ARE INTENDED TO SHOW END RESULT OF DESIGN.MINOR MODIFICATIONS MAY BE REQUIRED TO WHETHER SHOWN HEREON OR NOT AND TO PROTECT THEM FROM DAMAGE.THE CONTRACTOR DEMO DEMOLISH PLYWD PLYWOOD <br /> SUIT JOB DIMENSIONS OR CONDITIONS,AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION <br /> WORK. OF THIS WORK. DIA DIAMETER PM PROJECT MANAGER SUBMITTALS <br /> 11. THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, 9. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALES SHOWN ON DRAWINGS. DIM DIMENSION PROJ PROJECT REV OM SOLED FOR DRAFTER <br /> PAVING,CURBS,GALVANIZED SURFACES,ETC.,AND UPON COMPLETION OF WORK,REPAIR ANY DAMAGE 03/02/21 INITIAL ISSUE BDH <br /> THAT OCCURRED DURING CONSTRUCTION TO THE SATISFACTION OF THE PROJECT MANAGER AND/OR 10. THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS. DN DOWN PROP PROPERTY A 03/22/21 ADDRESSED COMMENTS BDH <br /> LANDLORD. <br /> 11. ALL ITEMS REMOVED DURING CONSTRUCTION WORK(I.E.,DRYWALL,PLYWOOD,CEILING PANELS, DTL DETAIL PT PRESSURE TREATED <br /> 12. ON A DAILY BASIS:KEEP GENERAL AREA CLEAN,HAZARD FREE,AND DISPOSE OF ALL DIRT,DEBRIS, ETC.)SHALL BE REPLACED TO MATCH EXISTING. DWG DRAWING RO ROUGH OPENING <br /> RUBBISH,AND REMOVE EQUIPMENT NOT SPECIFIED AS REMAINING ON THE PROPERTY.LEAVE PREMISES <br /> IN CLEAN CONDITION AND FREE FROM PAINT SPOTS,DUST OR SMUDGES OF ANY NATURE. THE FOLLOWING REQUIREMENTS SHALL BE MET FOR SPECIAL INSPECTION: EA EACH ROW RIGHT OF WAY �� �T <br /> 13. CONTRACTOR TO PROVIDE COMPLETE SET OF AS-BUILT DRAWINGS WITHIN 10 WORKING DAYS OF A. THE SPECIAL INSPECTOR SHALL BE UNDER THE SUPERVISION OF A REGISTERED PROFESSIONAL ELECT ELECTRICAL RRU REMOTE RADIO UNIT i +4 <br /> PROJECT COMPLETION. ENGINEER. +L <br /> ELEV ELEVATION REQ REQUIRED ' �V WAS .46 <br /> 14 WHERE A CONSTRUCTION DETAIL IS NOT SHOWN OR NOTED,THE DETAIL SHALL BE THE SAME AS FOR B. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE ARCHITECT/ENGINEER, <br /> OTHER SIMILAR WORK. AND OTHER DESIGNATED PERSONS.ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE EQ EQUAL SBTC SOLID BARE TINNED COPPER <br /> ATTENTION OF THE CONTRACTOR FOR CORRECTION;THEN,IF UNCORRECTED,TO THE PROPER aO <br /> 15. ASTM SPECIFICATIONS NOTED ON THE DRAWINGS SHALL BE OF THE LATEST REVISION. DESIGN AUTHORITY AND THE BUILDING OFFICIAL. EQUIP EQUIPMENT SF SQUARE FEET <br /> EXT EXTERIOR SHT SHEET i <br /> 16 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTI9LITIES WHETHER C. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT SIGNED BY BOTH HE AND HIS t� <br /> SHOWN HERON OR NOT AND TO PROTECT THEM FROM DAMAGE.THE CONTRACTOR SHALL BEAR ALL SUPERVISOR STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS IN FIN FINISH SPEC SPECIFICATION / 20108971 <br /> EXPENSE OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH THE PROSECUTION OF THIS WORK. CONFORMANCE WITH THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE `TjV <br /> WORKMANSHIP PROVISIONS OF THE CODE. FLR FLOOR SQ SQUARE <br /> 17. ALL ITEMS REMOVED OR DAMAGED DURING CONSTRUCTION WORK WILL BE REPLACED OR REPAIRED TO ' N� <br /> 11- <br /> MATCH EXISTING. D. COMPLY WITH ALL CITY SPECIAL INSPECTION REQUIREMENTS. FT FOOT,FEET SS STAINLESS STEEL <br /> 18. ALL ELEMENTS OF EXISTING STRUCTURE TO REMAIN UNDISTURBED,UNLESS NOTED OTHERWISE. STANDARD STRUCTURAL STEEL NOTES: GA GAUGE STL STEEL <br /> EXISTING STRUCTURE IS ASSUMED TO BE IN GOOD CONDITION,FREE OF DAMAGE OR DETERIORATION. <br /> GALV GALVANIZED STRUCT STRUCTURE,STRUCTURAL <br /> CONTRACTOR TO VERIFY ALL ELEMENTS OF EXISTING STRUCTURE AFFECTED BY THIS MODIFICATION 1. ALL METAL WORK SHALL BE IN ACCORDANCE WITH THE SPECIFICATION GALVANIZED ASTM <br /> AND NOTIFY ENGINEER OF RECORD IF ANY DAMAGE,DETERIORATION OR DISCREPANCIES BETWEEN A123-A123M-02 UNLESS NOTED OTHERWISE. GC GENERAL CONTRACTOR TOC TOP OF CONCRETE T I L 5 0 N <br /> EXISTING CONDITIONS AND THOSE DEPICTED ON THESE CONSTRUCTION DRAWINGS ARE FOUND. <br /> 2. STRUCTURAL TUBING MEMBERS SHALL CONFORM TO ASTM A500,GRADE A OR A501. GWB GYPSUM WALL BOARD TOM TOP OF MASONRY <br /> SPECIAL INSPECTION 3. ALL WELDING SHALL BE DONE USING E70XX ELECTRODES AND WELDING SHALL CONFORM TO AISC GR GRADE THRU THROUGH 520 SW 6th Avenue, Suite 1250 <br /> AND AWS D1.1 WHERE FILLET WELD SIZES ARE NOT SHOWN,PROVIDE THE MINIMUM SIZE PER TABLE Portland, OR 97204 <br /> 1. IF REQUIRED,SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL J2.4 IN THE AISC"MANUAL OF STEEL CONSTRUCTION",14TH EDITION. GRND GROUND TNND TINNED infoOtilsontech.com tilsontech.com <br /> INSPECTOR. <br /> 4. BOLTED CONNECTIONS SHALL USE BEARING TYPE GALV.ASTM F3125 GRADE A325 BOLTS(5/8"DIA. HVAC HEATING,VENTING&AIR CONDITIONING UBC UNIFORM BUILDING CODE GLEN WOOD <br /> 2. THE SPECIAL INSPECTOR SHALL PROVIDE A COPY OF THEIR REPORT TO THE OWNER,ARCHITECT, UNO),GALV.PER ASTM F2329,AND SHALL HAVE A MINIMUM OF TWO BOLTS U.N.O AND SHALL <br /> STRUCTURAL ENGINEER,CONTRACTOR,AND BUILDING OFFICIAL AS EACH TEST IS COMPLETED. INCLUDE HEAVY-HEX NUTS AND STANDARD CUT WASHERS. HORIZ HORIZONTAL UG UNDERGROUND <br /> HT HEIGHT UNO UNLESS NOTED OTHERWISE 5828 Glenwood Ave <br /> 3. ANY MATERIAL WHICH FAILS TO MEET THE PROJECT SPECIFICATIONS SHALL IMMEDIATELY BE 5. NON-STRUCTURAL CONNECTIONS FOR HANDRAIL,LADDERS AND STEEL GRATING MAY USE 5/8"DIA <br /> BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER.SPECIAL GALVANIZED ASTM A307 BOLTS U.N.O. IBC INTERNATIONAL BUILDING CODE UP UNDERGROUND POWER Everett, WA 98203 <br /> INSPECTOR TESTING REQUIREMENTS APPLY EQUALLY TO ALL BIDDER DESIGNED COMPONENTS. Snohomish COUNTY <br /> 6. ALL STRUCTURAL PIPE ASTM A53,TYPE E OR S.GRADE B. ID INSIDE DIAMETER OF UNDERGROUND FIBER 1� <br /> 4. INSPECTION FOR PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS FOR THE MATERIAL <br /> USED IF THE CONSTRUCTION TOOK PLACE ON SITE.CONTINUOUS INSPECTION WILL NOT BE SPECIAL INSPECTION: IN INCH VIF VERIFY IN FIELD SHEET TITLE <br /> REQUIRED DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION INSUL INSULATION VERT VERTICAL GENERAL NOTES <br /> AND FURNISHES EVIDENCE OF COMPLIANCE. 1. IF REQUIRED,SPECIAL INSPECTIONS SHALL BE PERFORMED BY AN INDEPENDENT SPECIAL <br /> INSPECTOR PER CODE FOR THE FOLLOWING ITEMS. TNT INTERIOR WP WATERPROOF <br /> 5. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL REPORT CERTIFYING THAT ALL WORK REQUIRING <br /> SPECIAL INSPECTION WAS,TO THE BEST OF THE SPECIAL INSPECTOR'S KNOWLEDGE IN A. CONTINUOUS DURING THE INSTALLATION OF EXPANSION AND/OR ADHESIVE ANCHORS:INSPECT JBOX JUNCTION BOX W/ WITH DRAFTED BY: APPROVED BY; SHEET: REV <br /> CONFORMANCE WITH THE APPROVED PERMIT PLANS AND SPECIFICATIONS AND THE APPLICABLE HOLE SIZE,DEPTH,CLEANLINESS,AND INSTALLATION PER ICC REPORT. BDH EB GN-1 1 8 I <br /> Li <br /> WORKMANSHIP PROVISIONS. LB(S) POUND(S) W/O WITHOUT <br />