Laserfiche WebLink
Job Page <br /> tnxTower Glenwood 1 of 19 <br /> Core One Consulting Project Date <br /> 5062ndAve.Suite 1533 113.17' Monople 14:57:19 03/23/21 <br /> Seattle,WA Client Designed by <br /> Phone:(855)-708-2195 Tilson <br /> FAX: <br /> Tower Input Data <br /> The tower is a monopole. <br /> This tower is designed using the TIA-222-H standard. <br /> The following design criteria apply: <br /> Tower base elevation above sea level:334.50 ft. <br /> Basic wind speed of 98 mph. <br /> Risk Category II. <br /> Exposure Category C. <br /> Simplified Topographic Factor Procedure for wind speed-up calculations is used. <br /> Topographic Category: 1. <br /> Crest Height:0.00 ft. <br /> Nominal ice thickness of 1.0000 in. <br /> Ice thickness is considered to increase with height. <br /> Ice density of 56 pcf. <br /> A wind speed of 30 mph is used in combination with ice. <br /> Temperature drop of 50°F. <br /> Deflections calculated using a wind speed of 60 mph. <br /> A non-linear(P-delta)analysis was used. <br /> Pressures are calculated at each section. <br /> Stress ratio used in pole design is 1. <br /> Tower analysis based on target reliabilities in accordance with Annex S. <br /> Load Modification Factors used:Kes(Fw)=0.95,Kes(ti)=0.85. <br /> Local bending stresses due to climbing loads,feed line supports,and appurtenance mounts are not considered. <br /> Options <br /> Consider Moments-Legs 4 Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules <br /> Consider Moments-Horizontals Assume Legs Pinned 4 Calculate Redundant Bracing Forces <br /> Consider Moments-Diagonals 4 Assume Rigid Index Plate Ignore Redundant Members in FEA <br /> Use Moment Magnification J Use Clear Spans For Wind Area SR Leg Bolts Resist Compression <br /> 41 Use Code Stress Ratios J Use Clear Spans For KL/r All Leg Panels Have Same Allowable <br /> 41 Use Code Safety Factors-Guys ' Retension Guys To Initial Tension Offset Girt At Foundation <br /> Escalate Ice Bypass Mast Stability Checks I Consider Feed Line Torque <br /> Always Use Max Kz Use Azimuth Dish Coefficients 4 Include Angle Block Shear Check <br /> Use Special Wind Profile 4 Project Wind Area of Appurt. Use TIA-222-H Bracing Resist.Exemption <br /> 41 Include Bolts In Member Capacity J Autocalc Torque Arm Areas Use TIA-222-H Tension Splice Exemption <br /> I Leg Bolts Are At Top Of Section Add IBC.6D+W Combination Poles, <br /> Secondary Horizontal Braces Leg 4 Sort Capacity Reports By Component V Include Shear-Torsion Interaction <br /> Use Diamond Inner Bracing(4 Sided) Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow <br /> SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets <br /> SR Members Are Concentric Ignore KL/ry For 60 Deg.Angle Legs Pole Without Linear Attachments <br /> Pole With Shroud Or No Appurtenances <br /> Outside and Inside Corner Radii Are <br /> Known <br /> Tapered Pole Section Geometry <br /> LP 130 <br />