Laserfiche WebLink
I '� <br /> FLOORS <br /> / <br /> / <br /> / HOLD-DOWN OR SIMILAR <br /> TENSION DEVICE <br /> FLOOR SHEATHING NAILING AT , <br /> 6"MAXIMUM ON CENTER TO / <br /> JOIST WITH HOLD-DOWN / <br /> i <br /> + + / it , <br /> I r' + + <br /> FLOOR JOIST / \ DECK JOIST <br /> / <br /> / <br /> / <br /> For SI: 1 inch=25.4 mm. <br /> FIGURE 507.2.3(1) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> SHEATHING <br /> NOTE: SIDING <br /> THIS DETAIL IS APPLICABLE <br /> WHERE FLOOR JOISTS ARE FLASHING FOR <br /> PARALLEL TO DECK JOISTS. WATER TIGHTNESS <br /> DECKING <br /> • I1I•I1' � APPROVED JOIST HANGERS <br /> 2"MIN. I,III'I 2x LEDGER WITH FASTENERS <br /> . .I.i'�i1,WI IN ACCORDANCE WITH TABLE R507.2 <br /> _—awn HOLD-DOWN DEVICE MIN 750 LB.CAPACITY <br /> FLOOR JOISTS AT 4 LOCATIONS,EVENLY DISTRIBUTED <br /> IN ALONG DECK AND ONE WITHIN 2"OF EACH <br /> END OF THE LEDGER. HOLD-DOWN DEVICES <br /> SHALL FULLY ENGAGE DECK JOIST PER <br /> HOLD-DOWN MANUFACTURER. <br /> A FULLY THREADED 3/e"DIAMETER LAG <br /> SCREW PREDRILLED W/MIN.3"PENETRATION <br /> TO CENTER OF TOP PLATE, STUDS,OR HEADER. <br /> For SI:1 inch=25.4 mm,1 foot=304.8 mm. <br /> FIGURE R507.2.3(2) <br /> DECK ATTACHMENT FOR LATERAL LOADS <br /> 152 2015 INTERNATIONAL RESIDENTIAL CODE® <br />