tTi%v <br />.w Cii11 <br />R1, SEPARATE SANITARY FACILITIES SHALL BE PROVIDED FOR EACH SEX WHEN THE <br />NUMBER OF EMPLOYEES EXCEEDS FOUR, PLUMBING FACILITIES SHALL BE <br />PROVIDED IN ACCORDANCE WITH CHAPTER 20, <br />R2. ALL TOILET ROOMS SHALL BE VENTILATED WITH 5 AIR CHANGED PER HOUR BY <br />MECHANICAL MEANS. <br />R3. PROVIDE ADEQUATE CONCEALED .BLOCKING AND ANCHORING FOR ALL CEILING <br />AND WALL MOUNTED EQUIPMENT, HARDWARE AND ACCESSORIES. <br />R4. ALL RESTROOM WALLS AND THE WALLS OF ANY OTHER ROOM CONTAINING <br />WATER SOURCES SHALL BE FINISHED WITH CEMENT BACKING BOARD (OR <br />EQUAL), FULL HEIGHT OF THE WALLS. <br />CONSTRUCTION INSPECTIONS <br />CI-1 GENERAL CONTRACTOR SHALL PROVIDE AND COORDINATE ALL INSPECTIONS <br />NECESSARY FOR CONSTRUCTION ACCORDING TO THE CITIES REQUIREMENTS, <br />IF • <br />26. ALL CONDUIT AND OTHER ELECTRICAL EQUIPMENT MUST BE SUPPORTED FROM <br />THE STRUCTURE ABOVE, ABSOLUTELY NO EQUIPMENT MAY BE SUPPORTED <br />FROM THE CEILING, ANY OPENINGS CUT INTO THE ACOUSTICAL CEILING TILES <br />SHALL BE CUT TO THE EXACT SIZE REQUIRED IN ORDER TO MAINTAIN ANY <br />MATERIAL RATINGS <br />27, ELECTRICAL DESIGN HAS BEEN BASED ON THE INSTALLATION OF 75 DEGREES C <br />CONDUCTORS CONNECTED TO TERMINAL EQUIPMENT, <br />O S CONNE L LUGS AND EQUIPM N , UL LISTED FOR <br />A MINIMUM 75 DEGREES C CONDUCTORS TERMINATED ON EQUIPMENT WITH A <br />LOWER RATING (60 DEGREES C) OR NO RATING SHOWN, SHALL HAVE <br />CONDUCTOR SIZE INCREASED TO CONFORM TO N.E.C. TABLE 310-16 AND UL <br />NO.4B9 REQUIREMENTS <br />2, ALL SWITCHBOARDS, PANEL BOARDS, DISCONNECT SWITCHES AND <br />CONTRACTORS, SHALL BE PROVIDED WITH LUGS LABELED AND RATED FOR A <br />MINIMUM 75 DEGREES C. SWITCHBOARDS, SPC, PANEL BOARDS, DISCONNECT <br />SWITCHES,N RS AND "LISTED" <br />CONTRACTORS � TRANSFORMERS ARE TO BE �ISTED AND <br />"IDENTIFIED" <br />AS RATED FOR A MINIMUM OF 75 DEGREES C CONDUCTOR <br />TERMINATION <br />2, AT THE CONCLUSION OF THIS PROJECT, THE ELECTRICAL CONTRACTOR SHALL <br />PROVIDE AN UPDATED TYPEWRITTEN DIRECTORY INSIDE EACH PANEL BOARD <br />PROPERLY IDENTIFYING EACH CIRCUIT USED AND THE SPECIFIC LOAD SERVED <br />30. CONTRACTOR SHALL COORDINATE INSTALLATION OF UTILITIES ABOVE THE <br />CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION <br />OF AND FURTHER CHANGES TO THE MECHANICAL, PLUMBING AND FIRE <br />SPRINKLER SYSTEM, TEC, CONDUIT AND PIPE TO BE RUN TO MAXIMIZE USE OF <br />CEILING SPACE FOR USE BY OTHER TRADES <br />31, ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN <br />�O <br />INTERRUPTING RATING NOT LESS THAN THE MAXIMUM SHORT CIRCUIT <br />CURRENT TO WHICH THEY MAY BE SUBJECTED <br />32. ALL DEVICES INSTALLED OUTSIDE OR IN DAMP LOCATIONS SHALL BE APPROVED <br />WEATHERPROOF <br />33, THE E,C, SHALL NOT BORE, OTCH OR IN ANYWAY CUT INTO ANY STRUCTURAL <br />MEMBER WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT OR STRUCTURAL <br />ENGINEER, INSTALL CONDUITS FOR ROOF MOUNTED EQUIPMENT BELOW ROOF <br />AND STUB -UP AT EACH PIECE OF EQUIPMENT. FLASH AND SEAL ALL <br />PENETRATIONS <br />34. THE ENTIRE WIRING SYSTEM SHALL BE TESTED FOR SHORT CIRCUITS, <br />GROUNDS AND INSULATION RESISTANCE BETWEEN CONDUCTORS AND TO <br />GROUND <br />35, PROVIDE PERMANENT PLASTIC LAMINATE NAME PLATE FOR ALL ELECTRICAL <br />EQUIPMENT, INCLUDING SWITCH GEAR, , PANELS SWITCHES CONTROLS ECT. <br />NAME PLATE SHALL SHOW EQUIPMENT TAG, r r VOLTAGE PHASE CURRENT RATING <br />AND FEED SOURCE <br />36. PROVIDE PERMANENT PLASTIC LAMINATE NAMEPLATE AT ALL SERVICE <br />DISCONNECT DEVICES TO INDICATE "SERVICE DISCONNECTING MEANS" <br />37. VERIFY EXACT LOCATIONS AND SIZE OF MECHANICAL EQUIPMENT AND POINTS <br />OF CONNECT WITH INSTALLING CONTRACTOR PRIOR TO ROUGHING IN FOR <br />SAME <br />38. ALL CONDUIT IN EXPOSED AREAS SHALL BE ROUTED TIGHT TO THE UNDERSIDE <br />OF THE STRUCTURE ABOVE <br />30, CONTRACTOR SHALL TANDEM WIRE (I) LAMP OR (3) LAMP FLUORESCENT LIGHT <br />FIXTURES WHENEVER FIXTURE IS RECESSED MOUNTED AND WITHIN 10° OF <br />EACH OTHER OR IS SURFACE OR PENDANT MOUNTED WITHIN l' OF EACH OTHER <br />40. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL HARDWARE REQUIRED FOR <br />COMPLETE INSTALLATION, WHETHER OR NOT INDICATED BY FIXTURE CATALOG <br />NUMBER, REFER TO ELECTRICAL SPECIFICATIONS <br />41. ALL, LIGHT FIXTURES MOUNTED IN WE OR DAMP LOCATION TO CARRY <br />APPROPRIATE U.L. LABEL, <br />42, ALL FLUORESCENT FIXTURES SHALL HAVE ENERGY SAVING C.E.C. APPROVED T3 <br />LAMPS AND ELECTRONIC BALLASTS <br />43. WHERE APPLICABLE, RECESSED INCANDESCENT AND H.I.D. FIXTURES ARE TO <br />BE USED WITH BATT-TYPE INSULATION, CUT 3" MINIMUM AROUND FIXTURE AND <br />ARE TO HAVE THERMAL PROTECTION <br />44. CONTRACTOR TO PROVIDE ALL LAMPS NOT FURNISHED WITH FIXTURES <br />45. FOR ANY DEVIATION FROM SPECIFIED LIGHT FIXTURES AND EQUIPMENT, IT <br />WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO GUARANTEE <br />LIGHT LEVELS PROVIDED IN THE ORIGINAL DESIGN <br />46. ELECTRICAL ENGINEER IS NOT RESPONSIBLE FOR TYPE OF CEILING BEING <br />INSTALLED. REFER TO ARCHITECTURAL PLANS FOR EXACT CEILING TYPE, <br />CONTRACTOR SHALL VERIFY CEILING TYPE/FIXTURE COMPATIBILITY BEFORE <br />ORDERING FIXTURES <br />47. IT IS UNDERSTOOD BY ALL PARTIES THAT ANY SUBSTITUTIONS OF SPECIFIED <br />PRODUCTS ARE DONE FOR THE PURPOSE OF COST SAVINGS TO THE OWNER, <br />THEREFORE, ANY MATERIALS SUBSTITUTIONS OR DEVIATIONS PROPOSED BY <br />THE CONTRACTOR SHALL BE INCLUDED WITH THE INITIAL BID AND SHALL <br />SHOW A LINE ITEM CREDIT TO THE OWNER FOR EACH ITEM SUBSTITUTED IN <br />LIEU OF SPECIFIED PRODUCTS <br />48. PROVIDE ALL EXIT SIGNS WITH DIRECTIONAL ARROWS AS REQUIRED. <br />