Laserfiche WebLink
Abbreviations <br />@ <br />AT <br />IFC. <br />INTERNATIONAL FIRE CODE <br /># <br />NUMBER <br />IPC. <br />INTERNATIONAL PLUMBING <br />ALT. <br />ALTERNATE <br />CODE <br />AVG. <br />AVERAGE <br />IRC. <br />INTERNATIONAL RESIDENTIAL <br />AWG. <br />AWNING <br />CODE <br />BLDG. <br />BUILDING <br />INT. <br />INTERIOR <br />BM. <br />BEAM <br />LIN. <br />LINEN CLOSET <br />CAS. <br />CASEMENT <br />LT. <br />LIGHT <br />CFM. <br />CUBIC FEET PER MINUTE <br />MAT. <br />MATERIAL <br />CLR. <br />CLEAR <br />MIN. <br />MINIMUM <br />CL. <br />CENTER LINE <br />MTL. <br />METAL <br />CLG. <br />CEILING <br />NO. <br />NUMBER <br />CLO. <br />CLOSET <br />NTS. <br />NOT TO SCALE <br />COL. <br />COLUMN <br />OC. <br />ON CENTER <br />CONC. <br />CONCRETE <br />OH. <br />OPPOSITE HAND <br />CONT. <br />CONTINUOUS <br />OSB. <br />ORIENTED STRAND BOARD <br />CPT. <br />CARPET <br />LAM. <br />PARALLEL LAMINATION <br />DF. <br />DOUGLAS FIR <br />PLYWD. <br />PLYWOOD <br />DH. <br />DOUBLE HUNG <br />P/PNT. <br />PRIME AND PAINT <br />DIA. <br />DIAMETER <br />PL. <br />PROPERTY LINE <br />DN. <br />DOWN <br />PT. <br />PRESSURE TREATED <br />IDS. <br />DOWNSPOUT <br />PS. <br />PARALLEL STRAND LUMBER <br />D <br />DYER <br />RO. <br />ROUGH OPENING <br />ELEC. <br />ELECTRICAL <br />SD. <br />SMOKE DETECTOR <br />EQ. <br />EQUAL <br />SG. <br />SAFETY GLASS <br />EX. <br />EXISTING <br />SH. <br />SINGLE HUNG <br />EXT. <br />EXTERIOR <br />SIM. <br />SIMILAR <br />EW. <br />EACH WAY <br />SF. <br />SQUARE FOOT <br />FIN. <br />FINISH <br />SQ. <br />SQUARE <br />FLR. <br />FLOOR <br />SL. <br />SLIDING <br />FRIG. <br />REFRIGERATOR <br />SS. <br />STAINLESS STEEL <br />FTG. <br />FOOTING <br />TBD. <br />TO BE DETERMINED <br />FX. <br />FIXED <br />T/B <br />TOP & BOTTOM <br />GA. <br />GAUGE <br />TF. <br />TOP FLANGE <br />GFIC <br />GROUND FAULT INTERRUPTER <br />UNO. <br />UNLESS NOTED OTHERWISE <br />CIRCUIT <br />VB. <br />VAPOR BARRIER <br />GLB. <br />GLUE LAMINATED BEAM <br />VTO. <br />VENT TO OUTSIDE <br />GWB. <br />GYPSUM WALL BOARD <br />W <br />WASHING MACHINE <br />HGRS. <br />HANGERS <br />W/ <br />WITH <br />HDG. <br />HOT DIPPED GALVANIZED <br />WD. <br />WOOD <br />HM. <br />HEMLOCK <br />W/O <br />WITHOUT <br />HT. <br />HEIGHT <br />WRB. <br />WEATHER RESISTANT BARRIER <br />IBC. <br />INTERNATIONAL BUILDING <br />CODE <br />IEC. <br />INTERNATIONAL ELECTRIC <br />CODE <br />Electrical Symbols <br />ELECTRICAL - DATA - AUDIO LEGEND <br />SYMBOL DESCRIPTION <br />=y CEILING FAN <br />Q VENTILATION FANS: CEILING FANS,WALL MOUNTED <br />® CEILING MOUNTED LIGHT FIXTURES: SURFACE/PENDANT, <br />RECESSED,HEAT LAMP, LOW VOLTAGE <br />WALL MOUNTED LIGHT FIXTURES; FLUSH MOUNTED, <br />® WALL SCONCE <br />CHANDELIER LIGHT FIXTURE <br />FLUORESCENT LIGHT FIXTURE <br />0 PUCK LIGHTING <br />EMERGENCY WALL LIGHTING <br />Q 240V RECEPTACLE <br />VVI GFco 110V RECEPTACLES: DUPLEX, WEATHER PROOF, GFCI <br />$ wP� 3$ a$ SWITCHES: SINGLE POLE,WEATHER PROOF,3-WAY, 4-WAY <br />"'$ T$ SWITCHES: DIMMER, TIMER <br />A$ AUDIO VIDEO: CONTROL PANEL, SWITCH <br />sP sP SPEAKERS: CEILING MOUNTED, WALL MOUNTED <br />ceg `-'g tl WALL JACKS: CATS, CATS+ TV, TV/CABLE <br />5Z TELEPHONE JACK <br />INTERCOM <br />Q THERMOSTAT <br />a Q DOOR CHIME, DOOR BELL <br />s° SMOKE DETECTORS: CEILING MOUNTED, WALL MOUNTED <br />CO DETECTORS: CEILING MOUNTED <br />@P CO /SMOKE DETECTORS: CEILING MOUNTED <br />EP ELECTRICAL BREAKER PANEL <br />Site Map <br />Symbols <br />0- <br />GRID NUMBER/LETTER <br />EXISTING CONCRETE <br />�---- <br />DETAIL NUMBER/LETTER <br />""'"' ` .Y "' <br />NEW CONCRETE <br />SHEET NUMBER <br />® <br />MASONRY <br />DOOR NUMBER <br />O <br />® <br />BEAM WITH SUPPORT <br />WINDOW NUMBER <br />COLUMN <br />ROOM NUMBER <br />NEW DOOR <br />SECTION NUMBERAETTER <br />EXISTING DOOR TO BE <br />SHEET NUMBER <br />REMOVED <br />INTERIOR ELEVATION NUMBER— <br />EXISTING DOOR TO REMAIN <br />SHEET NUMBER <br />_A <br />POCKET DOOR <br />LOW PARTITION/RAILING <br />O <br />BIFOLD DOOR <br />- - - - e <br />EXISTING TO BE REMOVED <br />STRUCTURAL PANEL <br />EXISTING WALL TO REMAIN <br />STRUCTURAL MEMBER <br />NEW WALL <br />CONTINUES THIS LEVEL <br />STRUCTURAL MEMBER <br />Energy Requirements <br />Legal Description <br />FAIRMOUNT BLK 003 D-00 LOTS 7,8,9,10,11 & 12 EXCTH PTN OF LOT 10 <br />DEEDED TO SNO CO FOR RD AF NO 731196 & EXC S20FT OF SD LOTS l I & 12 <br />FOR RD & TGW TH PTN OF LOT 13 SD PLAT DAF -BEG AT NELY COR SD LOT 13 <br />TH S32*55 OOW ALG E LN OF SD LOT 400.43FT TAP ON NLY MGN OF 112TH ST <br />SW BEING N LN OF S 20FT OF SD LOT 13 TH N89*23 50W ALG SD NLY MGN OF <br />N LN OF S 20FTOF SD LOT 67.38FT TO LN 37.50FT ELY OF W LN OF E1/2 SD LOT <br />14 TH S32*55 OOE ALG SD LN 399.59FT TO N LN OF SD LOT 13 THN90*00 OOE <br />ALG N LN OF SD LOT 67.83FT TO POB PER CITY EVE BLA NO 13-96 REC AF NO <br />9610290442 & 9610295003 <br />PARCEL NUMBER 00442900300700 <br />Building Information <br />Zone <br />SITE AREA 2.96 AC.. <br />BUILDING AREA 9,623 SF. SPRINKLERED <br />TENANT SIZE 1,855 SF. <br />APPROVED <br />Office of Community, Planning & Economic <br />/ <br />PLANNING DEPARTMENI <br />NAME. ! DATE <br />Additional Permits Are Required <br />pagearchitects@gmaii.com <br />www.williampagearchitect.com <br />For This Project To Include: <br />Issue/Revisions <br />CJF��,, _ t ��w, <br />Plumbing Sprinkler <br />No. Date Comments <br />© Mechanical j ] <br />Fire Alarm <br />Permit #: <br />B2107-001 <br />Site Address: <br />11108 EVERGREEN WAY SUITE E <br />(] <br />Electrical <br />Owner: <br />JOYLAND LODGING LLC/LA MSL INC <br />Tenant: <br />ALEM MARKET <br />App. Date: <br />7/1/2021 <br />Proposed Use: <br />COMMERCIAL ALTERATIONS <br />no "i'ti­ <br />TI - CHANGE OF USE FROM RETAIL TO <br />Code Information <br />THIS PROJECT HAS BEEN DESIGN TO CONFORM TO THE FOLLOWING CC <br />2018 INTERNATIONAL RESIDENTIAL CODE <br />2018 INTERNATIONAL FIRE CODE <br />2018 INTERNATIONAL MECHANICAL CODE <br />2018 UNIFORM PLUMBING CODE AS ADOPTED BY THE WASHINGTON <br />BUILDING CODE COUNCIL. <br />2018 WASHINGTON STATE ENERGY CODE <br />2020 NATIONAL ELECTRICAL CODE <br />CITE' OF EVERETT <br />REVIEWED FOR PERMIT <br />THESE DOCUMENTS HAVE NOT BEEN <br />APPROVED FOR THE ISSUANCE OF <br />PUBLIC WORKS, MECHANICAL, FIRE <br />SUPPRESSION, ELECTRICAL OR <br />PLUMBING PERMITS. <br />Owner/Consultants <br />OWNER ALEM MARKET <br />11108 EVERGREEN WAY SUITE E <br />EVERETT, WASH.98204 <br />ARCHITECT WILLIAM PAGE ARCHITECTS <br />P.O. BOX 665 <br />FREELAND, WASHINGTON 98249 <br />360-341-1958 <br />CONTRACTOR TBD. <br />Index to Drawings <br />Reviewed By:_ <br />Office Set <br />Permit #: <br />Site Address: <br />Owner: <br />Tenant: <br />App. Date: <br />Proposed Use: <br />Description: <br />Reviewed By:_ <br />Office Set <br />SEPARATE TYPE I HOOD <br />MECHANICAL & SUPPRESSION <br />SUBMITTALS REQUIRED <br />FOR PERMIT <br />�R 1 ow. i EiAl <br />JtPP <br />c3REMOMMMUIM <br />C1 REJECTW- <br />p sEE art t��/+u <br />The isswMn of a permit shell not <br />be construed as suttjt to violate, <br />cancel or set aside any pmvision of <br />the Everett tint Code or other <br />appilic" tfu{a""tN taws. The <br />Wince of a pro* based on <br />taO-112truction doewnw0a"COW <br />data tilW noWe++erd'thtr tyre Code <br />or enom <br />Vl' rCA5'( WIC <br />��► �e- Ch)e <br />LIMITED GROCERY WITH TAKEOUT <br />! t � ?�-t <br />Date: <br />Job Site Set Fire/Planning Set <br />P2107-001 <br />11108 EVERGREEN WAY SUITE E <br />JOYLAND LODGING LLC/LA MSL INC <br />ALEM MARKET <br />7/1/2021 <br />COMMERCIAL ALTERATIONS <br />PLUMBING FOR GREASE TRAP, KITCHEN <br />SINK, AND MOP SINK ,+ <br />Date: [ <br />Job Site Set Fire/Planning Set <br />AUG 2 6 2021 <br />CITY OF EVERETT <br />Permit Services <br />Copyright 2021 William Page Architects <br />Alem Market <br />11108 Evergreen Way <br />Everett, Washington <br />Sheet Title <br />Project Information <br />Project No. 2021-18 <br />Date 06/15/2021 <br />Scale AS NOTED <br />Drawn By WJP <br />Checked By WJP <br />Sheet <br />A-1 <br />of Total Sheets <br />