Laserfiche WebLink
ABBREVIATIONS <br />& <br />AND <br />L <br />ANGLE <br />@ <br />AT <br />° <br />DEGREES <br />0 <br />DIAMETER <br /># <br />NUMBER OR POUND <br />AB <br />ANCHOR BOLT <br />ABV <br />ABOVE <br />ACOUS <br />ACOUSTICAL <br />ACP <br />ACOUSTICAL CEILING PANEL <br />ACT <br />ACOUSTICAL CEILING TILE <br />ADJ <br />ADJACENT OR ADJUSTABLE <br />AFF <br />ABOVE FINISH FLOOR <br />AGG <br />AGGREGATE <br />ALUM <br />ALUMINUM <br />APPROX <br />APPROXIMATE <br />ARCH <br />ARCHITECTURAL <br />BD <br />BOARD <br />BLDG <br />BUILDING <br />BLKG <br />BLOCKING <br />BM <br />BEAM <br />CAB <br />CABINET <br />CANT <br />CANT STRIP <br />CB <br />CATCH BASIN <br />CFCI <br />CONTRACTOR FURNISHED CONTRACTOR <br />INSTALLED <br />CJ <br />CONTROLJOINT <br />CKT <br />CRICKET <br />CL <br />CENTERLINE <br />CLG <br />CEILING <br />CLO <br />CLOSET <br />CLR <br />CLEAR <br />CNTRTOP <br />COUNTERTOP <br />COL <br />COLUMN <br />CONC <br />CONCRETE <br />CONST <br />CONSTRUCTION <br />CONT <br />CONTINUOUS <br />CPT <br />CARPET <br />CT <br />CERAMIC TILE <br />CTC <br />CENTER TO CENTER <br />CTR <br />CENTER <br />DBL <br />DOUBLE <br />DIA <br />DIAMETER <br />DIM <br />DIMENSION <br />DN <br />DOWN <br />DR <br />DOOR <br />DS <br />DOWN SPOUT <br />DWG <br />DRAWING <br />DWR <br />DRAWER <br />E <br />EAST <br />EA <br />EACH <br />EIFS <br />EXTERIOR INSULATION & FINISH SYSTEM <br />ELEC <br />ELECTRICAL <br />ELEV <br />ELEVATION <br />EQ <br />EQUAL <br />EQUIP <br />EQUIPMENT <br />EXIST <br />EXISTING <br />EXP <br />EXPANSION <br />EXT <br />EXTERIOR <br />FD <br />FLOOR DRAIN <br />FDN <br />FOUNDATION <br />FF <br />FACTORY FINISH <br />FFE <br />FINISH FLOOR ELEVATION <br />FIN <br />FINISH <br />FL <br />FLASHING <br />FLR <br />FLOOR <br />FLUOR <br />FLOURESCENT <br />FP <br />FROST PROOF <br />FRP <br />FIBERGLASS REINFORCED PLASTIC <br />FT <br />FOOT OR FEET <br />FTG <br />FOOTING <br />FURR <br />FURRING <br />GA <br />GAUGE <br />GALV <br />GALVANIZED <br />GL <br />GLASS OR GLAZING <br />GLB <br />GLU-LAMINATED BEAM <br />GR <br />GRADE <br />GWB <br />GYPSUM WALLBOARD <br />GYP <br />GYPSUM <br />HA <br />HANDICAP ACCESSIBLE <br />HB <br />HOSE BIBB <br />HC <br />HOLLOW CORE <br />HDWD <br />HARDWOOD <br />HM <br />HOLLOW METAL <br />HORIZ <br />HORIZONTAL <br />HT <br />HEIGHT <br />HW <br />HOT WATER <br />IBC <br />INTERNATIONAL BUILDING CODE <br />ID <br />INSIDE DIAMETER <br />IE <br />INVERT ELEVATION <br />IFC <br />INTERNATIONAL FIRE CODE <br />IMC <br />INTERNATIONAL MECHANICAL CODE <br />INSUL <br />INSULATION <br />INT <br />INTERIOR <br />IRC <br />INTERNATIONAL RESIDENTIAL CODE <br />JAN <br />JANITOR <br />JST <br />JOIST <br />JT <br />JOINT <br />LAM <br />LAMINATE <br />LAV <br />LAVATORY <br />MANUF <br />MANUFACTURER <br />MAX <br />MAXIMUM <br />MB <br />MACHINE BOLT <br />MDF <br />MEDIUM DENSITY FIBERBOARD <br />MDO <br />MEDIUM DENSITY OVERLAY PLYWOOD <br />MECH <br />MECHANICAL <br />MFR <br />MANUFACTURER <br />MIN <br />MINIMUM <br />MISC <br />MISCELLANEOUS <br />MO <br />MASONRY OPENING <br />MTL <br />METAL <br />N <br />NORTH <br />NIC <br />NOT IN CONTRACT <br />NRP <br />NON -REMOVABLE PIN <br />NO <br />NUMBER <br />NOM <br />NOMINAL <br />NTS <br />NOT TO SCALE <br />OA <br />OVERALL <br />OC <br />ON CENTER <br />OD <br />OUTSIDE DIAMETER <br />OFCI <br />OWNER FURNISHED CONTRACTOR INSTALLED <br />OF01 <br />OWNER FURNISHED OWNER INSTALLED <br />OPNG <br />OPENING <br />OSB <br />ORIENTED STRAND BOARD <br />P.LAM <br />PLASTIC LAMINATE <br />PERP <br />PERPENDICULAR <br />PL <br />PLATE <br />PLYWD <br />PLYWOOD <br />PR <br />PAIR <br />PT <br />POINT OR PRESSURE TREATED <br />R <br />RISER <br />RAD <br />RADIUS <br />RD <br />ROOF DRAIN <br />REF <br />REFERENCE <br />REFR <br />REFRIGERATOR <br />REINF <br />REINFORCED <br />REQ <br />REQUIRED <br />RES <br />RESILIENT <br />REV <br />REVISED OR REVISION <br />RFG <br />ROOFING <br />RM <br />ROOM <br />RO <br />ROUGH OPENING <br />S <br />SOUTH <br />S&V <br />STAIN & VARNISH <br />SC <br />SOLID CORE <br />SCHEID <br />SCHEDULE <br />SHEATH <br />SHEATHING <br />SECT <br />SECTION <br />SF <br />SQUARE FOOTAGE OR SQUARE FEET <br />SHT <br />SHEET <br />SIM <br />SIMILAR <br />SKYLT <br />SKYLIGHT <br />SPEC <br />SPECIFICATION <br />SQ <br />SQUARE <br />SS <br />'STAINLESS STEEL <br />STD <br />STANDARD <br />STL <br />STEEL <br />STOR <br />STORAGE <br />STRUCT <br />STRUCTURAL <br />SV <br />SHEET VINYL <br />SYM <br />SYMMETRICAL <br />T&B <br />TOP & BOTTOM <br />T&G <br />TONGUE &GROOVE <br />TEMP <br />TEMPERATURE <br />T/O <br />TOP OF <br />TR <br />TREAD <br />TS <br />TUBE STEEL <br />TYP <br />TYPICAL <br />UBC <br />UNIFORM BUILDING CODE <br />UFC <br />UNIFORM FIRE CODE <br />UNF <br />UNFINISHED <br />UNO <br />UNLESS NOTED OTHERWISE <br />UON <br />UNLESS OTHERWISE NOTED <br />UPC <br />UNIFORM PLUMBING CODE <br />VERT <br />VERTICAL <br />VTO <br />VENT TO OUTSIDE <br />W <br />WEST <br />W/ <br />WITH <br />W/D <br />WASHER/DRYER <br />W/o <br />WITHOUT <br />WC <br />WATER CLOSET <br />WD <br />WOOD <br />WH <br />WATER HEATER <br />WT <br />WEIGHT <br />YD YARD DRAIN <br />A. BE RESPONSIBLE FOR PROVIDING WORK AND MATERIAL IN ACCORDANCE WITH <br />APPLICABLE CODES AND ORDINANCES. <br />PROPERTY OWNER: <br />COMMUNITY HEALTH CENTER <br />OF SNOHOMISH COUNTY <br />8609 EVERGREEN WAY <br />B. VERIFY FIELD DIMENSIONS AND EXISTING CONDITIONS. EVERETT, WA 98208 <br />C. OBTAIN PERMITS AS REQUIRED BY PROPER JURISDICTION FOR HEATING AND PH: 425-789-3700 <br />VENTILATING SYSTEMS, ELECTRICAL WORK, AND PLUMBING SYSTEMS. CONTACT: DION KAPETANOV <br />D. BE RESPONSIBLE FOR COORDINATING WORK INCLUDING ADDITIONAL PERMITS AND ARCHITECT: <br />SUBCONTRACTOR WORK. ARCHITECTURAL WERKS, INC. <br />11416 98TH AVENUE NE - SUITE 200 <br />E. SET NEW PARTITIONS DIMENSIONED FROM FACE OF GYP TO FACE OF GYP UNLESS KIRKLAND, WA 98033 <br />OTHERWISE NOTED. PH: 425-823-2244 <br />CONTACT: JANET MONDA <br />F. PROVIDE SOLID BLOCKING FOR WALL HUNG ITEMS (i.e. CABINETS, PAPER <br />DISPENSERS, VIEW BOXES); COORDINATE WITH OTHER TRADES. <br />G. UNDERCUT DOORS APPROXIMATELY 1/2" FOR SHEET VINYL SURFACES. <br />H. CLEAN SURFACES PRIOR TO OCCUPANCY OF SPACE. <br />I. MAINTAIN A TRASH BIN ON THE PREMISES FOR THE COLLECTION OF <br />CONSTRUCTION DEBRIS, CONTRACTOR SHALL DISPOSE OF DEBRIS AND REMOVE <br />TRASH BIN PRIOR TO FINAL OCCUPANCY. <br />J. SEAL AND WATERPROOF PENETRATIONS OF THE CONCRETE SLAB (I.E., PLUMBING <br />LINES, FLOOR ELECTRICAL AND/OR TELEPHONE MONUMENTS, ETC.). <br />K. MAKE EXIT DOORS OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR ANY <br />SPECIAL KNOWLEDGE OR EFFORT. <br />L. VERIFY THERMOSTAT LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. <br />M. PRESSURE TREAT WOOD IN CONTACT WITH CONCRETE, MASONRY, OR EARTH. <br />N. ISOLATE DISSIMILAR METALS TO PREVENT CORROSION. <br />0. PROVIDE MECHANICAL AND ELECTRICAL SYSTEMS AS BIDDER DESIGNED. <br />P. CALL CONFLICTS OR QUESTIONS TO THE ARCHITECT'S ATTENTION FOR RESOLUTION <br />BEFORE PROCEEDING. <br />Q. DO NOT SCALE DRAWINGS, CONTACT ARCHITECT OR OWNER FOR ANY NEEDED <br />CLARIFICATION. <br />R. PATCH & REPAIR EXISTING ROOF AS REQUIRED FOR PROPOSED MECHANICAL & <br />PLUMBING SCOPE. <br />TENANT OWNER: <br />COMMUNITY HEALTH CENTER <br />OF SNOHOMISH COUNTY <br />8609 EVERGREEN WAY <br />EVERETT, WA 98208 <br />PH: 425-789-3700 <br />CONTACT: DION KAPETANOV <br />SCOPEOF O <br />THE PROJECT CONSISTS OF A REMODEL TO 1ST FLOOR AND 3RD FLOOR OF AN EXISTING OFFICE <br />BUILDING FOR USE AS A MEDICAL CLINIC AND OFFICE SPACE. MINOR EXTERIOR WORK TO <br />INCLUDE REMOVAL OF EXTERIOR DOORS AND REPLACEMENT OF WINDOWS. INTERIOR <br />RENOVATIONS TO INCLUDE STUD WALL PARTITIONS, GYP. WALLBOARD, MILLWORK, FLOORING, <br />SUSPENDED CEILING SYSTEMS AND GYP. CEILINGS, AND NEW ELECTRICAL, MECHANICAL, AND <br />PLUMBING SYSTEMS. MODIFY FIRE -LIFE SAFETY AND FIRE SUPPRESSION SYSTEMS AS REQUIRED <br />PER NEW ROOM CONFIGURATIONS. SITE WORK TO INCLUDE MODIFICATIONS TO A DRIVEWAY <br />AND REPLACEMENT OF AN EXISTING RETAINING WALL. <br />ELECTRICAL, MECHANICAL, PLUMBING, FIRE -LIFE SAFETY, AND FIRE SUPPRESSION SYSTEMS TO BE <br />BIDDER DESIGNED. <br />LEGAL <br />DESCRIPTION <br />STRUCTURAL ENGINEER: <br />SWENSON SAY FAGET <br />TAX ID#: 00582202200101, 00582202200102, 00582202200201, <br />00582202200202 <br />2124 THIRD AVENUE, SUITE 100 <br />SEATTLE, WA 98121 <br />SOUTH PARK <br />ADD TO EVERETT REPLAT BLKS 19 TO 28 BLK 22 D-01- S 55FT OF LOT 1. <br />P H : 206-443-6212 <br />CONTACT: DAN SAY <br />SHEET <br />INDEX <br />AO.1 <br />COVER SHEET <br />AO.Z <br />1ST FLOOR CODE SUMMARY <br />FIRE DEPT. �t#E�VAO.3 <br />2ND FLOOR CODE SUMMARY <br />FEVEIREVRE" <br />APPROVED <br />AO.4 <br />3RD FLOOR CODE SUMMARY <br />Af" WITil�VA <br />AM REW <br />A1.1 <br />REFERENCE SITE PLAN�� <br />A2.0 <br />1ST FLOOR DEMOLITION PLAN <br />Q Mt CN.IST/11ANDOW <br />A2.1 <br />3RD FLOOR DEMOLITION PLAN <br />The NMUWM Of pe"nkshall not <br />be construasd as &#Atwrityt too Violate, <br />A2.2 <br />1ST FLOOR PLAN <br />cancel or see any pmvislon of <br />AZ.3 <br />3RD FLOOR PLAN <br />the Evemnfiret orotow <br />appl fopletioas or WM. Tht <br />A3.0 <br />1ST FLOOR DEMOLITION RCP <br />issualceofapllr"* as <br />consbucW doculineiift and ~ <br />A3.1 <br />3RD FLOOR DEMOLITION RCP <br />date shah not~ftthe FireCode <br />A3.2 <br />1ST FLOOR REFLECTED CEILING PLAN <br />OffalfMMr Uifftthoconvetion <br />A3.3 <br />3RD FLOOR REFLECTED CEILING PLAN <br />of errors. _ <br />- <br />A4.1 <br />EXTERIOR ELEVATIONS <br />By. ate <br />A5.1 <br />EXTERIOR DETAILS <br />A6.1 <br />INTERIOR DETAILS <br />A6.2 <br />INTERIOR DETAILS <br />A7.1 <br />INTERIOR ELEVATIONS TYP CLEARANCES <br />A7.2 <br />INTERIOR ELEVATIONS <br />A7.3 <br />INTERIOR ELEVATIONS <br />A7.4 <br />INTERIOR ELEVATIONS <br />A7.5 <br />INTERIOR ELEVATIONS <br />A7.6 <br />INTERIOR ELEVATIONS <br />A8.1 <br />CASEWORK DETAILS <br />A8.2 <br />CASEWORK DETAILS <br />A9.1 <br />DOOR SCHEDULE <br />A9.2 <br />RELITE & WINDOW SCHEDULES <br />A9.3 <br />1ST & 3RD FLOOR ROOM FINISH SCHEDULES <br />S1.1 <br />STRUCTURAL NOTES, MEMORANDUM & DETAILS <br />APPROVE <br />Office of ct mmunity, F4anning & Economic Development <br />PLANNING DEPARTMENT <br />NAMC �Lk�_DATE: 1.1 d a Z2 <br />This approval only applies to <br />the work being performed under <br />Permit #� 21 12. -0c <br />and does not recognize any <br />existing structure that may not <br />meet Zoning Code. <br />THESE DOCUMIENTS <br />HAVE NOT. y.Fp E" <br />p q g <br />aK <br />,N) MECHANICAL, RR <br />cUI'4 T -'ON, ELECTMCAL OR <br />CLU NiBING PERMITS. <br />Additional Permits Are Requlired <br />For This Project To Inol d : <br />P!,_umbing S P r iwn.kIer <br />��. N1eczhanical Fire <br />'ectnca I <br />2 <br />to <br />W E <br />0 O LL ro <br />c, t w <br />H LL Z -1 <br />J i <br />11J � W Z <br />LL J Z Z U <br />Sc <br />> U ~ 0 <br />LU <br />axox � � t <br />0 <br />wx� aw® v <br />oOUz2=Nwo� <br />_ o <br />'-' C 2 0 � n LLJ <br />NNOZONO to <br />coct U cn U ­4 U f- <br />Nai c (f) <br />*� �' QJ U <br />ro 11 <br />E°au 0 <br />L cu a W y <br />� o �Q0 <br />G <br />v <br />,� ca <br />00 <br />rs, <br />Sri <br />a <br />SEAL: <br />7297 REGISTERED <br />AR HITECT <br />JANU L MONDA <br />STATE OF WASHINGTO <br />>= Z <br />I-' W <br />Z <br />ou <br />0) < 0. <br />a. <br />2: 9 A.O.J w <br />:C9 F. E <br />O h- .J (1) <br />ZZ0Q: <br />� M <br />C/� w v L. a) CD <br />�"� UL t%� Q ono <br />O`� <br />W 0. <br />= UJ 13 <br />>Z�,.N> <br />�W Q e d-w <br />JOB NUMBER: 2156 <br />DRAWN: QC <br />CHECKED: JLM <br />DATE: 11/30/2021 <br />REVISIONS <br />SHEET NAME: <br />COVER SHEET <br />PERMIT SET <br />SHEET NUMBER: <br />UN <br />