My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2232 12TH ST 2022 Plans 2022-11-04
>
Address Records
>
12TH ST
>
2232
>
Plans
>
2232 12TH ST 2022 Plans 2022-11-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2022 8:29:24 AM
Creation date
10/12/2022 3:37:17 PM
Metadata
Fields
Template:
Address Document
Street Name
12TH ST
Street Number
2232
Permit
B2202-001
Year
2022
Notes
FIRE REPAIR FOR UNIT #110 / REMOVE-REPLACE INTERIOR FINISHES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NORTH ELEVATION OF UNIT 110 <br />INTERIOR LIVING ROOM <br />PARTITION WALL BETWEEN UNITS <br />21301 WD 01.dwg <br />PARKING <br />THIS PERMIT <br />4 SHADED <br />-7-7 <br />PARKING <br />SITE E PLAN ® TT�INFORMATION ON THIS SITE <br />SCALE: 1" = 30'-0" ® PLAN IS SCHEMATIC AND HAS <br />BEEN DERIVED FROM THE <br />RECORD DRAWINGS BY JOHN R. <br />NEWELL INC. P.S. DATED 19S5. <br />E <br />EVERETT FIRE DEPT. REVIEW <br />APPROVED <br />C3 APPROVED WITH CHANGES NOTED <br />❑ REVISE AND RESUBMIT <br />D KIIIEcIa <br />SEE ATOCNO CHECKLIST/HANDOUT <br />The issuance of a permit shall not <br />be construed as authority to violate, <br />cancel or set aside any provision of <br />the Everett Fire Code or other <br />applicable regulations or laws. The <br />issuance of a permit based on <br />construction documents and other <br />data shall not prevent the Fire Code <br />Offical from requiring the correction <br />of errors. <br />Permit#: B2202-001 <br />Site Address: 223212TH ST #110 <br />Owner: ALS CASCADIAN OWNER LLC <br />Tenant: PARC ON 12"' APTS <br />App. Date: 2/1/2022 <br />Proposed Use: COMMERCIAL ALTERATIONS <br />Descri p <br />SCOPU10,T%;K SUMMARY <br />TYPE: FIRE DAMAGE REPAIR <br />THE PURPOSE OF THESE DRAWINGS IS TO SHOW REPAIRS FOR THE DAMAGE CAUSED B' Review, <br />RECENT FIRE AT THE PARC ON 12TH APARTMENTS, UNIT 110 IN EVERETT, WASHINGTON. fFi <br />THE AFFECTED UNIT 18 LOCATED ON THE GROUND FLOOR OF THE SUBJECT THREE -STOP <br />APARTMENT BUILDING WITH UNAFFECTED UNITS ABOVE AND ADJACENT TO THE FIRE DAi .--- <br />UNIT. <br />THE REPAIRS LISTED ON THE DRAWINGS ARE DESIGNED IN ACCORDANCE WITH THE 2018 <br />INTERNATIONAL EXISTING BUILDING CODE (IEBC) WITH WASHINGTON STATE AMENDMENTS, <br />CHAPTER 4. <br />THE SCOPE OF WORK 18 TO REMOVE AND REPLACE ALL THE INTERIOR FINISHES, INSULATION, <br />DOORS, WINDOWS AND FIXTURES IN UNIT 110. THE ASSEMBLIES ARE BEING REPLACED TO <br />MATCH THE EXISTING FIRE PROTECTION PROVIDED IN ACCORDANCE WITH IEBC SECTION 403.1. <br />THERE IS NO STRUCTURAL DAMAGE TO THE UNIT OR BUILDING. THERE ARE NO ALTERATIONS <br />OR ADDITIONS. <br />THERE IS NO INCREASE TO THE EXISTING BUILDING FOOTPRINT, SQUARE FOOTAGE OR HEIGHT <br />PROPOSED IN THESE DRAWINGS. <br />EXCLUSIONS, <br />NO REVIEW HAS BEEN MADE OF THE ADEQUACY OF THE EXISTING FRAMING MEMBERS. <br />ARCHITECTURAL DETAILING SUCH AS, BUT NOT LIMITED TO: ROOFING, WEATHER -RESISTIVE <br />ASSEMBLIES, WATERPROOFING, EXTERIOR SIDING, FLASHING, VENTILATION, INTERIOR FINISHES, <br />MECHANICAL, ELECTRICAL, PLUMBING, ETC. IS NOT INCLUDED IN THIS DRAWINGS. <br />MECHANICAL, ELECTRICAL AND PLUMBING WORK IS NOT INCLUDED IN THIS SCOPE OF WORK <br />AND IS TO BE SUBMITTED UNDER A SEPARATE PERMIT, IF REQUIRED. <br />VICINITY MAP OM <br />SCALE: N.T.S. 4 V <br />ASSESSORS Nos.: 2s miom13 oo <br />LEGAL DESCRIPTION: <br />SEC 11 TWP 29 RGE 05RT-48F) THAT PTN SWI/4 SE1/4 NWl/4 DAF - COM AAP ON E LN OF W 24FT <br />OF 60 SUB 122.18FT NLY FIR AS MEAS AT R/A TO 8 LN OF SO SUB TH SSg*23 50E PLW CTR LN <br />OF 12TH ST PROJECTED ELY FIR PLATOF POWERS FIRST ADDITION TO EVERETT 263.28FT TH <br />N01*I1 14E PLW W LN OF SD SUB 322.19FT TO S LN OF SO 12TH ST TH 963*51 08E ALG SLY LN OF <br />SD 12TH ST201.50FT TPB TH N63*51 08W 201.50FT TH 601*I1 14W 422.44FT M/L TO N LN OF 13TH ST <br />AS CONVYD TO CITY OF EVERETT BY DEED REC UNDER AUDITORS FILE NO, (051411 TH ELY <br />ALG N LN OF SO 13TH STAS EST BY SO DEED 651411 DIST OF 295FT M/L TO W LN OF E 150FT <br />OF SD SE1/4 NWl/4TH N01*16 31E ALG SD W LN OF E 150FT OF SD SEI/4 NWI/4 2S6.14FT M/L TO S <br />LNOF 12TH ST AS CONVYD TO CITY OF EVERETT BY SO DEED REC UNDER AUDITORS FILE NO. <br />1202111 TH NWLY ALG SLY LN OF SO 12TH ST ALG ARC OF CRV DATA OF WH 18 GIVEN IN SD <br />CRV NO. 1202111 DIST OF 115FTM/L TAP ON SD CRV THAT IS 3.25FT SWLY OF TPB AS MEAS ALG <br />RAD OF SD CRV TH NELYt RADIAL TO SD CRY 3.25FT TO TPB EXC PTN CONVYD TO PUD NO. <br />I OF SNO CO RECAUD FILE NO, 921201 DAF BEG 24FT E OF SE COR OF LOT 11 BLK 238 PLAT <br />OF BROADWAY LAND COS 1ST ADD TO EVERETT TH N PLT E LN OF SD BLK 100FT TH E 320FT <br />TH S 100FT TH W 32OFT TO POB TGW ELY53.56FT OF FDT THAT PTN OF SE1/4 NWl/4 DAF BEG <br />24FT E OF SE COR LOT 11 BLK 238 BROADWAY LAND CO'S 1ST ADD TO EVT TH N PLT E LN OF <br />SD BLK FOR 100FT THE 320FT TH 6 100FT TH W 32OFT TO TPB LESS PTN CONVYD TO CITY <br />EVT BY AF NO 1181302 <br />WILDING DATA: <br />JURISDICTION: SNOHOMISH COUNTY <br />CODES: 2018 INTERNATIONAL EXISTING BUILDING CODE IW) U <br />2018 INTERNATIONAL BUILDING CODE (IBC) e <br />tion: FIRE REPAIR FOR UNIT#110/ REMOVE - <br />REPLACE INTERIOR FINISHES <br />'d BY: Date . <br />.e Set doh Site Set Fire/Planning Set <br />0 <br />Z <br />N <br />N <br />r <br />A <br />C <br />op- <br />Y <br />.� <br />O <br />Digitally signed <br />o <br />N <br />by Nathan L. <br />W W <br />Fritz -Pacific <br />_ <br />J <br />Engineering <br />Technologies, <br />M W <br />N� N <br />Inc. <br />Date: <br />2022.01.21 <br />07:22:35-08'00' <br />OCCUPANCY: R-2 (MULTI -FAMILY RESIDENCE) MAR 2022 ( - <br />CONSTRUCTION: TYPE V-A C7Ty 0.V UV <br />SPRINKLERS: NO Permit SeVERETT W <br />es <br />NO. STORIES: 3 IF <br />SHEET INDEX CITY OF � � LU <br />SHEET 1.0 SITE PLAN, VICINITY MAP AND PHOTOGRAPHS EVERETT Ntiq <br />SHEET 1.1 NOTES <br />REVIEWED FOR PERMIT <br />SHEET 2.0 PARTIAL FIRST FLOOR PLAN Z <br />SHEET 2.1 DETAILS O <br />Additional Permits Are Required V (� <br />For This Project To Include: � (�[ <br />'Q <br />�] Plumbing Sprinkler •o <br />Mechanical Fire Alarm (L "I !!.. <br />Electrical <br />ALL INFORMATION ON THIS DOCUMENT <br />1.0 <br />18 THE EXCLUSIVE PROPERTY OF <br />PACIFIC ENGINEERING TECHNOLOGIES, INC. <br />© COPYRIGHT 2022 <br />Job No. 213OIZO <br />N <br />x <br />N <br />N <br />m <br />N <br />N <br />
The URL can be used to link to this page
Your browser does not support the video tag.