My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2712 TAYLOR DR 2020 Plans 2022-12-01
>
Address Records
>
TAYLOR DR
>
2712
>
Plans
>
2712 TAYLOR DR 2020 Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 8:00:13 AM
Creation date
10/13/2022 10:25:48 AM
Metadata
Fields
Template:
Address Document
Street Name
TAYLOR DR
Street Number
2712
Permit
B2006-012
Year
2020
Notes
DESIGN AND CONSTRUCTION OF NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DI <br />E <br />F <br />CONTINUOUS HANDRAIL <br />PER SECTION �3 I I .7.8. I <br />"min. CLEAR FROM WALL 2"max <br />dia. KETUKN ENDS TO WALL <br />UPPED LEVL FF <br />+ 211.72' <br />OPEN RAIL CONSTRUCTION <br />PICKETS SHALL BE PLACED <br />'SUCH THAT A <br />5PIjE E 4" DIA CANNOT PADS <br />THROUGH <br />LR.0 R3 k 2. 1.3 $ EX.#! TRIANGULAR <br />OPENINGS @OPEN SIDE Of <br />STAIR FORMED <br />BY RI5EK,TKEAD * BOTT.P <br />IL OF GUARD <br />SHALL NOT ALLOW PAS5AC <br />E OF A SPHERE <br />G"DIA. <br />OPEN RISER CONSTRUCTION <br />PERM'TTE� PROVIDED THA <br />A 5PH <br />4" DIA CANNOT PASS THR <br />UG <br />(.K.0 R3I 1 .7.5.1 <br />"ruin <br />MAIN LEVI E�F � — <br />+ 200 A7' -. <br />INTERIOR r GUARDRAIL STAIR NOTES: <br />STAIRWAY CONSTRUCTION: <br />PER 2015 I.K,C CHAPTER 3 <br />SECTION K3 1 1 .5 <br />WINDING STAIRS PEF SECTION <br />R3 1 1 .7.4 1 R3 1 1 .7.5.2. I <br />19 <br />M <br />f PLYWOOD <br />@ LANDING <br />" 2 min. GYPSUM 13C <br />(WHEKE ACCE551 <br />2X4 NAILER <br />wr <br />I <br />r�9 Lo <br />STRINGERS I G" o.c MAX <br />2X IKE5TOP @ TOP * BOTTOM OF RUN <br />(RE 'D ALONG DETWEEN EACH STRINGER) <br />MAXIMUM RISER CANNOT EXCEED 7 3/4" AND MIN, TREAD CANNOT BE LESS THAN 10°.IRC SECTION R311.7.5.1 AND R311.7.5.2. <br />- HANDRAIL MUST NOT PROJECT MORE THAN 4 1/2" INTO THE STAIRWAY AND DUST BE ABLE TO RESIST A 200 LBS LOAD FROM ANY <br />DIRECTION, IRC SECTION R311.5 & TABLE R301.5. <br />PER SEC R312.1,3 CONTRACTOR TO MAKE SURE REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO <br />THE REQUIRED GUARD HEIGHT THAT ALLOW PASSAGE OF A SPHERE 4" (102rnm) IN A DIAMETER. <br />a LIGHTING IS REQUIRED AT THE TOP, BOTTOM AND ANY LANDINGS WITH CONTROLS AT THE TOP AND BOTTOM OF STAIRS WITH 6 <br />OR MORE RISERS. IRC SECTION R303.6 <br />THE SPACING BETWEEN INTERMEDIATE HANDRAIL MEMBERS MUST NOT ALLOW 4 SPHERE TO PASS THROUGH ANY OPENING. <br />IRC SECTION R312.1 <br />MINIMUM STAIRWAY WIDTH ABOVE HANDRAIL SHALL BE NO LESS THAN 36 IRC SECTION R311.7,1 <br />STAIR AND STAIR LANDING MINIMUM WIDTH SHALL BE NO LESS THAN 36" (31 1/2" CLEAR IF ONE HANDRAIL AND 27" CLEAR IF TWO <br />HANDRAILS), IRC SECTION R311.7.1 <br />THE TREADS LEADING EDGE CURVATURE CAN HAVE A MAX. RADIUS OF 9/16". THE MAX. BEVELLING OF NOSING SHALL BE NO MORE <br />THAN 112". IRC SECTION R311.7.5. <br />RISER OR TREAD MAXIMUM DIFFERENTIAL SHALL BE NO MORE THAN 3/8". IRC SECTION R311.7.5. 1&2. <br />NOSING IS NOT REQUIRED FOR STAIRS WITH TREADS GREATER THAN 11". IRC SECTION R311.7.5.3.. <br />-RAILING MUST BE ABLE TO WITHSTAND POINT LOAD 2001. BS IN ANY DIRECTION TYPICAI. <br />INTERIOR UNDER STAIR NOTES: <br />w INSTALL 5/8" TYPE'X.' GWB BELOW STAIRS @ CEILINGS AND WALLS. <br />FIRE BLOCKING @ MID SPAN AND IN STUD WALLS ALONG & IN -LINE WITH STRINGERS IS REQUIRED IF AREA UNDER STAIR IS <br />UNFINISHED. <br />LANDING NOTES: <br />LANDING WIDTH SHALL NOT BE LESS THAN THAT OF STAIR SERVED. IRC SECTION R311.7.6. <br />LANDING SHALL NOT BE LESS THAN 36" IN DIRECTION OF TRAVEL. IRC SECTION R311.7.6. <br />SPIRAL STAIRCASE: <br />- PER SEC IRC 2015 R311.7.10.1 SPIRAL STAIRWAYS ARE PERMITTED, PROVIDED THAT THE CLEAR WDTH AT AND A3 <br />BELOW THE HANDRAIL IS NOT LESS THAN 26" AND THE WALKLINE RADIUS IS NOT GREATER THAN 24", <br />EACH TREAD SHALL HAVE A DEPTH OF NOT LESS THAN 6 3/4" AT THE WALKLINE. <br />-ALL TREADS SHALL BE IDENTICAL AND THE RISE SHALL BE NOT MORE THAN 9 1/2". <br />-HEADROOM SHALL BE NOT LESS THAN 6'-6" <br />A 35 CLIP <br />I X 1lO" o«F� <br />OVER <br />TO RA <br />TYP . <br />2x THE <br />HDWD <br />5UBFL <br />SCAM l o V—Cr <br />SO MIN. STAIRWAY WIDTH <br />PER IRC R3 1 1.5 1 <br />4 <br />t L /l , v Y Ld <br />SINJIFSONI 51-CFED <br />IIUC28 OR EQUAL <br />BEAM PER PLAN <br />BELOW STAIR INSTALL 1/2" <br />G,W.B. CEILING WALLS <br />2X4 THRUST (3) 2X 1 2 STRINGERS <br />BLOCK <br />FIRE BLOCKING MID -SPAN <br />4' O.C. BELOW STAIR INSTALL I /2" <br />IVI <br />C d JOIST OR BLOCKING FLOOR BELOW <br />NOTE : GREATEST AND LATEST TREAD <br />RISER SHALL NOT VARY MORE THAN 318" <br />(PER IRCR3 1 1 ,5.3, I R3 1 1 5.3,2) <br />8 <br />I1 3 <br />b _. ' <br />�. <br />—ALIGN W1 NOSING OF <br />LANDING <br />MOUNTING BKACE5 <br />EVENLY SPACED 4'-0" <br />O.C. MAX, <br />12" <br />I i i4" O WOOD RAIL W/°. <br />1! /4" WOOD <br />RADIUSED TRAN51TIOPJS <br />- - - <br />HANDRAIL @UNITS, <br />RETURNS, <br />PAINTED METAL @ <br />I 112 <br />COMMON AREAS, TYP. <br />MIN. <br />ALL BRACKET <C <br />0 <br />ATTACHED �Ml 3/&1 <br />— LAG STUDS TO > <br />O <br />23" TYF <br />BLOCKING AS O G <br />— <br />SHOWN Q <br />N <br />2X� BLOCKING <br />�l 15 . 7� 1 <br />LANDING LEVEL <br />ML LANDING DETAIL <br />1 1 j2 I®- <br />DESIGNLYRIC <br />9824 223RD PL RIE <br />REDMOND WA 98053 <br />PH: 206-853-9874 <br />REVISIONS: <br />9/02/20 - COMMENTS FROM CITY <br />11/11/20 - COMMENTS FROM CITY <br />1/14/21 - COMMENTS FROM CITY <br />APPROVALS: <br />DES3GNED SS <br />II� <br />RS <br />DRAWN <br />SS <br />CHECKED <br />DATE 6-01-2020 <br />SCALE AS NOTED <br />a <br />PROJECT CLIENT' <br />SARANIP,fVJIT awAl IWAL <br />PROJECT: <br />DbAL11NAL RESIDENCE <br />SHEET TITLE, <br />STAIR DETAILS <br />CITY OF EVE ETT <br />RENEWED FOR PERMIT <br />PR #: 05092019 A6.02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.