Laserfiche WebLink
m <br />200.22' <br />B <br />o <br />� c <br />m <br />F <br />G <br />1 ! 2 I 3 4 5 <br />cv <br />m <br />I <br />N OTE5 <br />7 <br />1, ALL IPJTERIOR WALLS ARE TYPE 'A' UNLE5S OTHERWISE RIOTED. SEE I/A9.01 <br />2. SEE SHEET A9.01 FOR EXTERIOR WALL DETAILS * FOR ADDITIONAL WALL TYPE DETAILS. <br />3, PROVIDE 1 .G GA FLUSH TOILET. <br />4, PROVIDE GFC1 OUTLETS IN BATHROOM $ KITCHEN. <br />5. CAULK AND WEATHERSTRIP ALL DOORS AND PENETRATIONS, <br />G. 1 3/8" MIN, SOLID WOOD OR 1 3/8" MIN. HONEYCOMB STEEL DOOR (IRC R309. 1 }. <br />7. DIMENSIONS INDICATE ROUGH OPENINGS. MEASURE ACTUAL OPENINGS PRIOR TO <br />FABRICATION, MAXIMUM INFILTRATION FOR FACTORY BUILT WINDOWS TO DE 0.5 PER LlI•IEAL <br />FOOT OF OPERABLE SASH PERIMETER AS TESTED BY STAtlDARD A5TM E 283,73, <br />8, DOORS 1,10T LOCATED ON PLAN WITH DIMENSIONS ARE LOCATED BY TYP. DETAIL, 4" FROM <br />HINGE 51DE OF FRAME TO NEAREST 1rVALL. <br />9. ALL WINDOW GLAZING TO MEET WA,5HINGTON 5TATE ENERGY CODE 2015. REFEP, TO <br />GENERAL NOTES CH SHEET A 1.0 1 FOR DOOR AND WINDOW U-VALUES, <br />10, VERII=Y FIEL D COh1DITION5 BEFORE ORDERING DOORS AND WINDOWS. <br />1 1, SAFETY GLAZING: AS PER IRC R308.4, SAFETY GLAZING SHOULD BE INSTALLED AT THE <br />FOLLOWING LOCATIONS. <br />ALL GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL BE SAFETY GLAZING, WIRE <br />GLA55, LAMINATED GLA55, TEMPERED GLA55, OR SHATTER RESISTANT PLASTIC. <br />A. IN INGRESS AND EGRESS DOORS (INCLUDING ALL EXTERIOR DOORS). <br />B. IN FIXED AND 5LIDING PANELS OF 5LIDING DOORS, OTHER THAN WARDROBE DOORS. <br />C. 11y1 ALL STORM DOORS. <br />D. IN ALL NON -FRAMED SWINGING DOOR5. <br />E. IN ALL SHOWER AND TUB_ DOORS AND ENCI_05URE5. <br />F. ALL, OPERABLE OR INOPERABLE, WITHIN 24" RADIUS OF A DOOR IN A CLOSED POSITION <br />WHOSE BOTTOM EDGE IS GO" OR LESS ABOVE THE WALKING SURFACE (LEADED OR FACETED <br />GLA55 15 ACCEPTABLE HERE). <br />G. IN FIXED PANEL5, OTHER THAN THOSE COVERED IN 5ECTION 'F' ABOVE WHICH HAVE A <br />GLAZED AREA IN EXCE55 OF NINE (9) SQUARE FEET AND THE LOWEST EDGE 15 LE55 THAN 18;' <br />ABOVE THE FLOOR LEVEL OR WALKING SURF ACE. IN LIEU OF 5AFETY GLAZII'\IG, SUCH GLAZED <br />PANELS MAY BE PROTECTED WITH A HORIZONTAL MEMBER OE NOT LESS THAN 1 .5" IN WIDTH <br />LOCATED BETWEEN 24" AND 3G" ABOVE THE WALKING SURFACE ( LEADED OR FACETED GLA55 <br />IS ACCEPTABLE HERE). <br />12, SKYLIGHT GLAZING TO BE LAMINATED GLASS WITH A MINIMUM OF 0.38 MM. POLYVINYL <br />BUTKYAL OR EQUIVALffNT INTER-LAYEF- <br />1 3, ALL OPERABLE WINDOWS THROUGHOUT, TO BE "VENTED" TYPE. <br />14, SKYLIGHTS TO BE INSTALLED AS REQUIRED 11\1 IRC SEC P308.G AND THE 20) 5 <br />WA5HIPIGTON STATE ENERGY CODE. <br />15. 5EE SHEET A9.01 *- A7.01 FOR DOOR/ WINDOW DETAIL5. <br />I G. SMOKE ALARMS: PER IRC (201 5) 5ECTIOI\1 R3 14.3 , SMOKE ALARMS SHALL BE <br />I1\15TALLED IN THE FOLLOWING LOCATIONS: <br />1. IN EACH SLEEPING ROOM. <br />2. OUT5IDE EACH 'SEPARATE 5LEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. <br />3. ON EACH STORY OF THE DWELLING, <br />THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNEK THAT THE ACTUATION <br />OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE RESIDENCE, WIRING SHALL BE <br />PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOP, <br />OVEKCURRENT PROTECTION, <br />17, CARBON MONOXIDE ALARPyl: PROVIDE A UL 2034 COMPLIANT CARBON MONOXIDE <br />ALARM OUTSIDE OF EACH SEPARATE SLEEPING AREA 11\1 THE IMMEDIATE VICINITY OF THE <br />BEDROOMS. INSTALL. PER. IRC R3 15 AND MANUFACTURER'5 INSTR.UCTION5, <br />18, PER IRC TABLE M 1 507.4, PROVIDE MECHANICAL EXHAUST OF 50 CFM INTERMITTENT <br />CAPACITY. <br />19, PROVIDE FAUCETS IN BATHROOMS WITH MAX. FLOW OF 1.0 GPM. OR LESS <br />5HO1,A/ERHEAD AND KITCHEN 51NK5 OF 1.75 GPM OR LESS. <br />20, WATER RESISTANT "DENSHIELD" OR APPROVED ALT. (GWB) SHALL ONLY BE USED ON <br />WALLS OF TUB AND SHOWER ENCL05URE5, OR WATER CLOSET COMPARTMENT WALL5. <br />2 1. ALL 5HOWEK AREAS SHALL BE FINI5HED WITH A SMOOTH NON-AB5ORBENT MATERIAL <br />TO A HEIGHT OF 70° ABOVE THE DRAIN INLET, TH15 MATERIAL SHALL BE INSTALLED OVER A <br />MATERIAL WHICH 15 NOT ADVERSELY AFFECTED BY MOISTURE, <br />22, PROVIDE A MIN 20 MIN RATED DOOR BETWEEN GARAGE AND EQUIPED 5ELF CLOSING <br />DEVICE AS PER K 302.5. 1 <br />23. PER IRC R302.G PROVIDE (1) LAYER 1 /2" 'X' GWB AT WALLS 5EPARATIhIG RESIDENCE FROM <br />GARAGE AT GARAGE SIDE OF WALL5. SEE 3 /A9.01 FOR DETAILS. <br />24. PER TABLE IRC R302.G, PROVIDE (1) LAYER 5/8" TYPE 'X' GWB ON CIELING OF GARAGE <br />BETWEEN HABITABLE ROOMS AND GARAGE. SEE 9/A9.01 <br />25, CRAWL SPACE ACCESS: PROVIDE NEW 16" X 24" CRAWL SPACE ACCESS PER IRC R408.4. <br />PRO"VIDE M(NIfvIUM 18"X24" OPENING IN NEW STEM WALLS TO EN51-IR.E ACCESS TO THE NEW <br />CRAWL SPACES. <br />2G. PER IRC R302.7 ENCLOSED ACCE551BLE SPACE UNDER STAIRS SHALL HAVE WALLS, <br />UNDER -STAIR SURFACE AND ANY 50PFIT5 PROTECTED Ohl THE ENCLOSED 51DE WITH -L " <br />(I 2.7mm) GYP5UM BOARD. <br />27.PROVIDc KITCHEN RANGE HOOD OF MIN. I OOCFM. ANY EXHAUST OF MORE THAN <br />400CFM, PROVIDE MAKEUP AIR PER IRC M 1 503. <br />28.PER M 1307.2 APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE FASTENED OR <br />ANCHORED IN AN APPROVED MANHEF- <br />PER IRC 2015 SEC R4082 CRAWL SPACE VENTILATION CALCULATION: <br />AREA OF NEW CRAWL SPACE - 3387 5FT <br />CRAWL SPACE AREA / 150 = 23 5FT OF VENT AREA READ. <br />TYPICAL VENT 512E (75% EFFICIENCY) = (14"X8") X 0.75 <br />= 0,58 5FT/VENT NET FREE AREA <br />= 23 / 0.58 = 40 (NO. OF VENTS REQUIRED) <br />NO, OF VENTS PROVIDED = 40 <br />VENTING PROVIDED = 40X0.56 <br />23.2 SFT <br />29.VENTS SHALL BE COVERED WITH CORK05ION KE515TANT WIRE Mf-5H WITH OPENING OF <br />1 /4" MAX. <br />30.VENT5 LOCATED IN RIM J015T5 MUST BE BAFFLED (W5EC 502. 1 .4.7) <br />3 I .PROVIDE ONE VENT WITHIN 3 FT. OF EACH CORNER OF THE BUILDING. <br />32.5EE STRUCTURE FOR FOUNDATION PLAN AND CRAWL 5PACE LOCATION. <br />LEGEND <br />50 CFM FAN. SEE NOTE 18. <br />I OO 100 CFM FAN. SEE NOTE 27, <br />WHF WHOLE HOUSE FAN, <br />SMOKE DETECTOR5.5EE NOTE I G. <br />CARBON MONOXIDE DETECTOR. <br />SEE NOTE 17. <br />`HALL TYPE. SEE A9.01 FOR DETAILS <br />ABBREVIATIONS <br />CPT <br />CARPET <br />CONC <br />CONCRETE <br />DR <br />DOOR <br />(EG) <br />EGRESS <br />GL <br />GLASS <br />HDVVD <br />HARDWOOD <br />SC <br />SOLID CORE <br />EG <br />EGRESS WINDOW. 5EE NOTE I/A4.01 <br />5G <br />SAFETY GLAZING. SEE NOTE I I, <br />r <br />DESIGNLYRIC <br />9024 223RD PL NE <br />REDMOND WA 90053 <br />PH: 206-053-9074 <br />REVISIONS: <br />A9/02/20 - COMMENTS FROM CITY <br />11/11/20 COMMENTS FROM CITY <br />1/14/21 - COMMENTS FROM CITY <br />AI A A IJIT DHALI AL <br />PROJECT <br />HALT AL RESIDENCE <br />SHEET TITLE: <br />MAIN FLOOR PEAR <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />PR #: 05092019=Al01-=B] <br />cn <br />ct' <br />A <br />