<br />N OTE5
<br />7
<br />1, ALL IPJTERIOR WALLS ARE TYPE 'A' UNLE5S OTHERWISE RIOTED. SEE I/A9.01
<br />2. SEE SHEET A9.01 FOR EXTERIOR WALL DETAILS * FOR ADDITIONAL WALL TYPE DETAILS.
<br />3, PROVIDE 1 .G GA FLUSH TOILET.
<br />4, PROVIDE GFC1 OUTLETS IN BATHROOM $ KITCHEN.
<br />5. CAULK AND WEATHERSTRIP ALL DOORS AND PENETRATIONS,
<br />G. 1 3/8" MIN, SOLID WOOD OR 1 3/8" MIN. HONEYCOMB STEEL DOOR (IRC R309. 1 }.
<br />7. DIMENSIONS INDICATE ROUGH OPENINGS. MEASURE ACTUAL OPENINGS PRIOR TO
<br />FABRICATION, MAXIMUM INFILTRATION FOR FACTORY BUILT WINDOWS TO DE 0.5 PER LlI•IEAL
<br />FOOT OF OPERABLE SASH PERIMETER AS TESTED BY STAtlDARD A5TM E 283,73,
<br />8, DOORS 1,10T LOCATED ON PLAN WITH DIMENSIONS ARE LOCATED BY TYP. DETAIL, 4" FROM
<br />HINGE 51DE OF FRAME TO NEAREST 1rVALL.
<br />9. ALL WINDOW GLAZING TO MEET WA,5HINGTON 5TATE ENERGY CODE 2015. REFEP, TO
<br />GENERAL NOTES CH SHEET A 1.0 1 FOR DOOR AND WINDOW U-VALUES,
<br />10, VERII=Y FIEL D COh1DITION5 BEFORE ORDERING DOORS AND WINDOWS.
<br />1 1, SAFETY GLAZING: AS PER IRC R308.4, SAFETY GLAZING SHOULD BE INSTALLED AT THE
<br />FOLLOWING LOCATIONS.
<br />ALL GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL BE SAFETY GLAZING, WIRE
<br />GLA55, LAMINATED GLA55, TEMPERED GLA55, OR SHATTER RESISTANT PLASTIC.
<br />A. IN INGRESS AND EGRESS DOORS (INCLUDING ALL EXTERIOR DOORS).
<br />B. IN FIXED AND 5LIDING PANELS OF 5LIDING DOORS, OTHER THAN WARDROBE DOORS.
<br />C. 11y1 ALL STORM DOORS.
<br />D. IN ALL NON -FRAMED SWINGING DOOR5.
<br />E. IN ALL SHOWER AND TUB_ DOORS AND ENCI_05URE5.
<br />F. ALL, OPERABLE OR INOPERABLE, WITHIN 24" RADIUS OF A DOOR IN A CLOSED POSITION
<br />WHOSE BOTTOM EDGE IS GO" OR LESS ABOVE THE WALKING SURFACE (LEADED OR FACETED
<br />GLA55 15 ACCEPTABLE HERE).
<br />G. IN FIXED PANEL5, OTHER THAN THOSE COVERED IN 5ECTION 'F' ABOVE WHICH HAVE A
<br />GLAZED AREA IN EXCE55 OF NINE (9) SQUARE FEET AND THE LOWEST EDGE 15 LE55 THAN 18;'
<br />ABOVE THE FLOOR LEVEL OR WALKING SURF ACE. IN LIEU OF 5AFETY GLAZII'\IG, SUCH GLAZED
<br />PANELS MAY BE PROTECTED WITH A HORIZONTAL MEMBER OE NOT LESS THAN 1 .5" IN WIDTH
<br />LOCATED BETWEEN 24" AND 3G" ABOVE THE WALKING SURFACE ( LEADED OR FACETED GLA55
<br />IS ACCEPTABLE HERE).
<br />12, SKYLIGHT GLAZING TO BE LAMINATED GLASS WITH A MINIMUM OF 0.38 MM. POLYVINYL
<br />BUTKYAL OR EQUIVALffNT INTER-LAYEF-
<br />1 3, ALL OPERABLE WINDOWS THROUGHOUT, TO BE "VENTED" TYPE.
<br />14, SKYLIGHTS TO BE INSTALLED AS REQUIRED 11\1 IRC SEC P308.G AND THE 20) 5
<br />WA5HIPIGTON STATE ENERGY CODE.
<br />15. 5EE SHEET A9.01 *- A7.01 FOR DOOR/ WINDOW DETAIL5.
<br />I G. SMOKE ALARMS: PER IRC (201 5) 5ECTIOI\1 R3 14.3 , SMOKE ALARMS SHALL BE
<br />I1\15TALLED IN THE FOLLOWING LOCATIONS:
<br />1. IN EACH SLEEPING ROOM.
<br />2. OUT5IDE EACH 'SEPARATE 5LEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS.
<br />3. ON EACH STORY OF THE DWELLING,
<br />THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNEK THAT THE ACTUATION
<br />OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE RESIDENCE, WIRING SHALL BE
<br />PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED FOP,
<br />OVEKCURRENT PROTECTION,
<br />17, CARBON MONOXIDE ALARPyl: PROVIDE A UL 2034 COMPLIANT CARBON MONOXIDE
<br />ALARM OUTSIDE OF EACH SEPARATE SLEEPING AREA 11\1 THE IMMEDIATE VICINITY OF THE
<br />BEDROOMS. INSTALL. PER. IRC R3 15 AND MANUFACTURER'5 INSTR.UCTION5,
<br />18, PER IRC TABLE M 1 507.4, PROVIDE MECHANICAL EXHAUST OF 50 CFM INTERMITTENT
<br />CAPACITY.
<br />19, PROVIDE FAUCETS IN BATHROOMS WITH MAX. FLOW OF 1.0 GPM. OR LESS
<br />5HO1,A/ERHEAD AND KITCHEN 51NK5 OF 1.75 GPM OR LESS.
<br />20, WATER RESISTANT "DENSHIELD" OR APPROVED ALT. (GWB) SHALL ONLY BE USED ON
<br />WALLS OF TUB AND SHOWER ENCL05URE5, OR WATER CLOSET COMPARTMENT WALL5.
<br />2 1. ALL 5HOWEK AREAS SHALL BE FINI5HED WITH A SMOOTH NON-AB5ORBENT MATERIAL
<br />TO A HEIGHT OF 70° ABOVE THE DRAIN INLET, TH15 MATERIAL SHALL BE INSTALLED OVER A
<br />MATERIAL WHICH 15 NOT ADVERSELY AFFECTED BY MOISTURE,
<br />22, PROVIDE A MIN 20 MIN RATED DOOR BETWEEN GARAGE AND EQUIPED 5ELF CLOSING
<br />DEVICE AS PER K 302.5. 1
<br />23. PER IRC R302.G PROVIDE (1) LAYER 1 /2" 'X' GWB AT WALLS 5EPARATIhIG RESIDENCE FROM
<br />GARAGE AT GARAGE SIDE OF WALL5. SEE 3 /A9.01 FOR DETAILS.
<br />24. PER TABLE IRC R302.G, PROVIDE (1) LAYER 5/8" TYPE 'X' GWB ON CIELING OF GARAGE
<br />BETWEEN HABITABLE ROOMS AND GARAGE. SEE 9/A9.01
<br />25, CRAWL SPACE ACCESS: PROVIDE NEW 16" X 24" CRAWL SPACE ACCESS PER IRC R408.4.
<br />PRO"VIDE M(NIfvIUM 18"X24" OPENING IN NEW STEM WALLS TO EN51-IR.E ACCESS TO THE NEW
<br />CRAWL SPACES.
<br />2G. PER IRC R302.7 ENCLOSED ACCE551BLE SPACE UNDER STAIRS SHALL HAVE WALLS,
<br />UNDER -STAIR SURFACE AND ANY 50PFIT5 PROTECTED Ohl THE ENCLOSED 51DE WITH -L "
<br />(I 2.7mm) GYP5UM BOARD.
<br />27.PROVIDc KITCHEN RANGE HOOD OF MIN. I OOCFM. ANY EXHAUST OF MORE THAN
<br />400CFM, PROVIDE MAKEUP AIR PER IRC M 1 503.
<br />28.PER M 1307.2 APPLIANCES DESIGNED TO BE FIXED IN POSITION SHALL BE FASTENED OR
<br />ANCHORED IN AN APPROVED MANHEF-
<br />PER IRC 2015 SEC R4082 CRAWL SPACE VENTILATION CALCULATION:
<br />AREA OF NEW CRAWL SPACE - 3387 5FT
<br />CRAWL SPACE AREA / 150 = 23 5FT OF VENT AREA READ.
<br />TYPICAL VENT 512E (75% EFFICIENCY) = (14"X8") X 0.75
<br />= 0,58 5FT/VENT NET FREE AREA
<br />= 23 / 0.58 = 40 (NO. OF VENTS REQUIRED)
<br />NO, OF VENTS PROVIDED = 40
<br />VENTING PROVIDED = 40X0.56
<br />23.2 SFT
<br />29.VENTS SHALL BE COVERED WITH CORK05ION KE515TANT WIRE Mf-5H WITH OPENING OF
<br />1 /4" MAX.
<br />30.VENT5 LOCATED IN RIM J015T5 MUST BE BAFFLED (W5EC 502. 1 .4.7)
<br />3 I .PROVIDE ONE VENT WITHIN 3 FT. OF EACH CORNER OF THE BUILDING.
<br />32.5EE STRUCTURE FOR FOUNDATION PLAN AND CRAWL 5PACE LOCATION.
<br />LEGEND
<br />50 CFM FAN. SEE NOTE 18.
<br />I OO 100 CFM FAN. SEE NOTE 27,
<br />WHF WHOLE HOUSE FAN,
<br />SMOKE DETECTOR5.5EE NOTE I G.
<br />CARBON MONOXIDE DETECTOR.
<br />SEE NOTE 17.
<br />`HALL TYPE. SEE A9.01 FOR DETAILS
<br />ABBREVIATIONS
<br />CPT
<br />CARPET
<br />CONC
<br />CONCRETE
<br />DR
<br />DOOR
<br />(EG)
<br />EGRESS
<br />GL
<br />GLASS
<br />HDVVD
<br />HARDWOOD
<br />SC
<br />SOLID CORE
<br />EG
<br />EGRESS WINDOW. 5EE NOTE I/A4.01
<br />5G
<br />SAFETY GLAZING. SEE NOTE I I,
<br />r
<br />DESIGNLYRIC
<br />9024 223RD PL NE
<br />REDMOND WA 90053
<br />PH: 206-053-9074
<br />REVISIONS:
<br />A9/02/20 - COMMENTS FROM CITY
<br />11/11/20 COMMENTS FROM CITY
<br />1/14/21 - COMMENTS FROM CITY
<br />AI A A IJIT DHALI AL
<br />PROJECT
<br />HALT AL RESIDENCE
<br />SHEET TITLE:
<br />MAIN FLOOR PEAR
<br />CITY OF EVERETT
<br />REVIEWED FOR PERMIT
<br />PR #: 05092019=Al01-=B]