Laserfiche WebLink
3 <br />G <br />8 <br />ul <br />I <br />6 7 <br />Ind OTE5: <br />1. ALL INTERIOR. WALLS AKE TYPE 'A' UNLESS OTHERWISE NOTED. SEE I /A9.01 <br />2. SEE SHEET A9.01 FOR EXTERIOR WALL DETAILS * FOR ADDITIONAL WALL TYPE DETAILS. <br />3. PROVIDE 1 .G GA FLUSH TOILET, <br />4. PROVIDE GFCI OUTLETS IN BATHROOM * KITCHEN. <br />5. CAULK AND WEATHERSTRIP ALL DOORS AND PENETRATIONS. <br />G. 1 3/8" MIN. SOLID WOOD OR, 13/8" MIN. HONEYCOMB STEEL DOOR (IRC R309. 1). <br />7. DIMENSIONS- INDICATE ROUGH OPENII,dG5. MEASURE ACTUAL OPENINGS PRIOR TO <br />FABRICATION. MAXIMUM INFILTRATION FOR, FACTORY BUILT WINDOWS TO BE 0.5 PER LINEAL <br />FOOT OF OPERABLE SASH PERIMETER AS TESTED BY STANDARD ASTM E 283.73, <br />8. DOORS NOT LOCATED ON PLAN WITH DIMENSIONS ARE LOCATED BY TYP. DETAIL, 4" FROM <br />HINGE 51DE OF FRAME TO NEAREST WALL, <br />9, ALL WINDOW GLAZING TO MEET WASHINGTON STATE ENERGY CODE 2015. REFER TO <br />GENERAL NOTE5 ON 5HEET A 1 .01 FOR DOOR AND WINDOW U-VALUES. <br />10, VERIFY FIELD CONDITIONS BEFORE OKDEKING DOORS AND WINDOWS. <br />1 1 . 5AFETY GLAZING: A5 PER IKC R308.4, SAFETY CLAZING SHOULD BE INSTALLED AT THE <br />FOLLOWING LOCATIONS. <br />ALL GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL BE SAFETY GLAZING, WIRE <br />GLASS, LAMINATED GLASS, TEMPERED GLASS, OR SHATTER RESISTANT PLASTIC. <br />A. IN ING KE55 AND EGKES5 DOORS (INCLUDING ALL EXTERIOR DOOK5). <br />B. IN FIXED AND 5LIDIHG PANELS OF SLIDING DOORS, OTHER THAN WARDROBE DOORS. <br />C. IN ALL STOKM DOORS. <br />D. IN ALL NON -FRAMED SWINGING DOORS, <br />E. IN ALL SHOWER AND TUB DOORS AND ENCLOSURES. <br />F. ALL, OPERABLE OR INOPERABLE, WITHIN 24" RADIUS OF A DOOR IN A CL05ED <br />POSITION WHOSE BOTTOM EDGE 15 GO" OR LE55 ABOVE THE WALKING SURFACE (LEADED OR <br />FACETED GLA55 15 ACCEPTABLE HERE). <br />G. IN FIXED PANELS, OTHER THAN THOSE COVERED 11\1 SECTION 'F' ABOVE WHICH HAVE A <br />GLAZED AREA IH EXCESS OF HINE (9) SQUARE FEET AND THE LOWEST EDGE 15 LESS THAN 1 8" <br />ABOVE THE FLOOR LEVEL OR WALKING 5URFACE. IN LIEU OF SAFETY GLAZING, SUCH GLAZED <br />PANELS MAY BE PROTECTED WITH A HORIZONTAL MEMBER OF NOT LESS THAN 1 .5" IN WIDTH <br />LOCATED BETWEEN 24" AND 3G" ABOVE THE WALKING SURFACE ( LEADED OR FACETED GLA55 <br />15 ACCEPTABLE HERE). <br />12. SKYLIGHT GLAZING TO BE LAMINATED GLA55 WITH A MINIMUM OF 0,38 MM. POLYVINYL <br />BUTKYAL OR EQUIVALENT INTER -LAYER. <br />13, ALL OPERABLE WINDOWS THROUGHOUT, TO BE "VENTED" TYPE. <br />14. SKYLIGHTS TO BE INSTALLED AS REQUIRED IN IRC SEC R308.G AND THE 2015 <br />WASHINGTON STATE ENERGY CODE. <br />15, SEE SHEET A9.0 1 $ A7.0 1 FOR DOOR/ WINDOW DETAILS. <br />I G. SMOKE ALARMS: PER [KC (201 5) SECTION R3 14.3 , SMOKE ALARMS SHALL BE <br />INSTALLED IN THE FOLLOWING LOCATIONS: <br />1. IN EACH SLEEPING ROOM. <br />2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, <br />3. 01\1 EACH STORY OF THE DWELUI\IG. <br />THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNEK THAT THE ACTUATION <br />OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE RESIDENCE. WIRING SHALL BE <br />PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THANTH05E REQUIRED FOR <br />OVEKCURRENT PROTECTION, <br />17. CARBON MONOXIDE ALARM: PROVIDE A UL 2034 COMPLIANT CARBON MONOXIDE <br />ALARM OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE <br />BEDROOMS. INSTALL PER, IKC K3 1 5 AND MANUFACTUKER.'5 INSTRUCTIONS, <br />18. PER (KC TABLE M 1 507.4, PROVIDE MECHANICAL. EXHAUST OF 50 CFM INTERMITTENT <br />CAPACITY, <br />19.WHOLE HOUSE VENTILATION SYSTEM: IN ACCORDANCE WITH SECTION M 1 507.3, <br />PROVIDE WHOLE -HOUSE MECHANICAL VENTILATION AT CONTINUOUS RATE OK <br />INTERMITTENTLY, WITH CONTROLS THAT ENABLE MANUAL OVERRIDE. <br />MINIMUM REQUIRED LOCAL EXHAUST RATE5 (TABLE M 1507.4) AKE AS FOLLOWS: <br />AREAS TO EXHAUSTED EXHAUST RATES <br />KITCHENS 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS <br />BATHROOMS -TOILET ROOMS MECHANICAL EXHAUST CAPACITY OF 50 CFM <br />INTERMITTENT OR 20 CFM CONTINUOUS <br />OUTDOOR INTAKE AND EXHAUST OPENINGS SHALL BE LOCATED PER K303.5. 1 AS FOLLOWS: <br />A) OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED RIOT LESS THAN 10 FEET FROM ANY <br />HAZARDOU5 OR NOXIOUS CONTAMINANT, EXCEPT WHERE THE INTAKE OPENING IS LOCATED 3 <br />FEET OK GREATER BELOW THE CONTAMINANT SOURCE <br />B) EXHAUST AIR, SHALL NOT BE DIRECTED ONTO WALKWAYS. <br />OUTSIDE AIR EXHAUST AND INTAKE OPENINGS SHALL BE PROTECTED IN ACCORDANCE WITH <br />R303.G, AI\ID SHALL HAVE AUTOMATIC AND GRAVITY DAMPERS THAT CL05E WHEN THE <br />VENTILATION SYSTEM IS NOT OPERATING. <br />SOLID FUEL -BURNING APPLIANCES SHALL BE PKOVIDED WITH COMBUSTION AIR IN <br />ACCORDANCE WITH SECTION M 170 1. <br />PER IRC CHAPTER 15 TABLE M) 507.3.3(I) CONTINUOUS WHF MECH VENT <br />SYSTEM AIRFLOW RATE KEQUIREMEHT5 FOR A HOUSE OF 4500-GOOO 5Q.FT. <br />AREA AND FOR 5 BEDROOM WE NEED A AIRFLOW OF 120 CfM WHICH WILL BE 51TUATED ON <br />FOR 2.4 HK5 A DAY, <br />TOTAL CONDITIONED AREA = G805.0 Q.F T . <br />CONTROLS OF WHF ARE LOCATED IN LAUNDRY ROOM. <br />ALL THE HABITABLE ROOMS HAVE OPERABLE WINDOWS TO BRING THE OUTDOOR AIR IN, <br />20, PROVIDE FAUCETS IN BATHROOMS WITH MAX. FLOW OF 1.0 GPM. OR LESS <br />5HOWERHEAD AND KITCHEN 511,,IKS OF 1.75 GPM OK LESS. <br />2 1. WATER. RESISTANT "DEN51-1IELD" OF, APPROVED ALT. (GWB) SHALL ONLY BE USED ON <br />WALLS OF TUB AND SHOWER ENCLOSURES, OR WATER CLOSET COMPARTMENT WALLS. <br />22.ALL SHOWER AREAS SHALL BE FINISHED WITH A SMOOTH NON-AB50RBENT MATERIAL TO <br />A HEIGHT OF 70" ABOVE THE DRAIN INLET. THIS MATERIAL SHALL BE INSTALLED OVER A <br />MATERIAL WHICH 15 NOT ADVERSELY AFFECTED BY MOISTURE. <br />23.ATTIC ACCESS. PROVIDE 22" x 30" ATTIC ACCESS PER IRC K807, SEE DETAIL 1 3/A9,01 . <br />R3 1 2.2. 1 WINDOW SILLS. IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN <br />OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR <br />SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A <br />MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOD, OF THE ROOM IN WHICH THE WINDOW <br />15 LOCATED. OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW <br />PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OFFNING5 ARE LOCATED WITHIN 24 <br />INCHES OF THE FINISHED FLOOK. <br />LEGEND <br />50 CFM FAN. SEE NOTE 18. <br />g 100 <br />100 CFM FAN. <br />PA G^✓NF <br />WHOLE HOUSE FAN. <br />5 <br />SMOKE DETECTOR5.5EE NOTE i G. <br />CARBON MONOXIDE DETECTOR. <br />SEE NOTE 17, <br />WALL TYPE. SEE A9.01 FOR DETAILS <br />ABBREVIATIONS <br />CPT <br />CARPET <br />CONC <br />CONCRETE <br />DR <br />DOOR <br />(EG) <br />EGRE55 <br />GL <br />GLA55 <br />HDWD <br />HARDWOOD <br />5C <br />SOLID CORE <br />EG <br />EGRESS WINDOW. SEE NOTE 1/A4.01 <br />SG <br />SAFETY GLAZING, SEE NOTE 1 1. <br />C5V <br />CRAWL SPACE VENT <br />DESIGN LYRIC <br />9824 223RD PL NE <br />REDMOND WA 98033 <br />PH: 206-853--9874 <br />REVISIONS; <br />9/02/20 - COMMENTS FROM CITY <br />11/11/?0 COMMENTS FROM CITY <br />1/14/21 - COMMENTS FROM CITY <br />APPROVALS: <br />DESIGNED SS <br />DRAWN IRS <br />CHECKED SS <br />DATE 6-01-2020 <br />SCALE AS NOTED <br />PROJECT CLIENT: <br />SARAMAhJJIT DHALIWR,L <br />DHALIWAL RESIDENCE <br />SHEET TITLE <br />UPPER FLOOR PLAN <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />