<br />Ind OTE5:
<br />1. ALL INTERIOR. WALLS AKE TYPE 'A' UNLESS OTHERWISE NOTED. SEE I /A9.01
<br />2. SEE SHEET A9.01 FOR EXTERIOR WALL DETAILS * FOR ADDITIONAL WALL TYPE DETAILS.
<br />3. PROVIDE 1 .G GA FLUSH TOILET,
<br />4. PROVIDE GFCI OUTLETS IN BATHROOM * KITCHEN.
<br />5. CAULK AND WEATHERSTRIP ALL DOORS AND PENETRATIONS.
<br />G. 1 3/8" MIN. SOLID WOOD OR, 13/8" MIN. HONEYCOMB STEEL DOOR (IRC R309. 1).
<br />7. DIMENSIONS- INDICATE ROUGH OPENII,dG5. MEASURE ACTUAL OPENINGS PRIOR TO
<br />FABRICATION. MAXIMUM INFILTRATION FOR, FACTORY BUILT WINDOWS TO BE 0.5 PER LINEAL
<br />FOOT OF OPERABLE SASH PERIMETER AS TESTED BY STANDARD ASTM E 283.73,
<br />8. DOORS NOT LOCATED ON PLAN WITH DIMENSIONS ARE LOCATED BY TYP. DETAIL, 4" FROM
<br />HINGE 51DE OF FRAME TO NEAREST WALL,
<br />9, ALL WINDOW GLAZING TO MEET WASHINGTON STATE ENERGY CODE 2015. REFER TO
<br />GENERAL NOTE5 ON 5HEET A 1 .01 FOR DOOR AND WINDOW U-VALUES.
<br />10, VERIFY FIELD CONDITIONS BEFORE OKDEKING DOORS AND WINDOWS.
<br />1 1 . 5AFETY GLAZING: A5 PER IKC R308.4, SAFETY CLAZING SHOULD BE INSTALLED AT THE
<br />FOLLOWING LOCATIONS.
<br />ALL GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL BE SAFETY GLAZING, WIRE
<br />GLASS, LAMINATED GLASS, TEMPERED GLASS, OR SHATTER RESISTANT PLASTIC.
<br />A. IN ING KE55 AND EGKES5 DOORS (INCLUDING ALL EXTERIOR DOOK5).
<br />B. IN FIXED AND 5LIDIHG PANELS OF SLIDING DOORS, OTHER THAN WARDROBE DOORS.
<br />C. IN ALL STOKM DOORS.
<br />D. IN ALL NON -FRAMED SWINGING DOORS,
<br />E. IN ALL SHOWER AND TUB DOORS AND ENCLOSURES.
<br />F. ALL, OPERABLE OR INOPERABLE, WITHIN 24" RADIUS OF A DOOR IN A CL05ED
<br />POSITION WHOSE BOTTOM EDGE 15 GO" OR LE55 ABOVE THE WALKING SURFACE (LEADED OR
<br />FACETED GLA55 15 ACCEPTABLE HERE).
<br />G. IN FIXED PANELS, OTHER THAN THOSE COVERED 11\1 SECTION 'F' ABOVE WHICH HAVE A
<br />GLAZED AREA IH EXCESS OF HINE (9) SQUARE FEET AND THE LOWEST EDGE 15 LESS THAN 1 8"
<br />ABOVE THE FLOOR LEVEL OR WALKING 5URFACE. IN LIEU OF SAFETY GLAZING, SUCH GLAZED
<br />PANELS MAY BE PROTECTED WITH A HORIZONTAL MEMBER OF NOT LESS THAN 1 .5" IN WIDTH
<br />LOCATED BETWEEN 24" AND 3G" ABOVE THE WALKING SURFACE ( LEADED OR FACETED GLA55
<br />15 ACCEPTABLE HERE).
<br />12. SKYLIGHT GLAZING TO BE LAMINATED GLA55 WITH A MINIMUM OF 0,38 MM. POLYVINYL
<br />BUTKYAL OR EQUIVALENT INTER -LAYER.
<br />13, ALL OPERABLE WINDOWS THROUGHOUT, TO BE "VENTED" TYPE.
<br />14. SKYLIGHTS TO BE INSTALLED AS REQUIRED IN IRC SEC R308.G AND THE 2015
<br />WASHINGTON STATE ENERGY CODE.
<br />15, SEE SHEET A9.0 1 $ A7.0 1 FOR DOOR/ WINDOW DETAILS.
<br />I G. SMOKE ALARMS: PER [KC (201 5) SECTION R3 14.3 , SMOKE ALARMS SHALL BE
<br />INSTALLED IN THE FOLLOWING LOCATIONS:
<br />1. IN EACH SLEEPING ROOM.
<br />2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS,
<br />3. 01\1 EACH STORY OF THE DWELUI\IG.
<br />THE ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNEK THAT THE ACTUATION
<br />OF ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE RESIDENCE. WIRING SHALL BE
<br />PERMANENT AND WITHOUT A DISCONNECTING SWITCH OTHER THANTH05E REQUIRED FOR
<br />OVEKCURRENT PROTECTION,
<br />17. CARBON MONOXIDE ALARM: PROVIDE A UL 2034 COMPLIANT CARBON MONOXIDE
<br />ALARM OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
<br />BEDROOMS. INSTALL PER, IKC K3 1 5 AND MANUFACTUKER.'5 INSTRUCTIONS,
<br />18. PER (KC TABLE M 1 507.4, PROVIDE MECHANICAL. EXHAUST OF 50 CFM INTERMITTENT
<br />CAPACITY,
<br />19.WHOLE HOUSE VENTILATION SYSTEM: IN ACCORDANCE WITH SECTION M 1 507.3,
<br />PROVIDE WHOLE -HOUSE MECHANICAL VENTILATION AT CONTINUOUS RATE OK
<br />INTERMITTENTLY, WITH CONTROLS THAT ENABLE MANUAL OVERRIDE.
<br />MINIMUM REQUIRED LOCAL EXHAUST RATE5 (TABLE M 1507.4) AKE AS FOLLOWS:
<br />AREAS TO EXHAUSTED EXHAUST RATES
<br />KITCHENS 100 CFM INTERMITTENT OR 25 CFM CONTINUOUS
<br />BATHROOMS -TOILET ROOMS MECHANICAL EXHAUST CAPACITY OF 50 CFM
<br />INTERMITTENT OR 20 CFM CONTINUOUS
<br />OUTDOOR INTAKE AND EXHAUST OPENINGS SHALL BE LOCATED PER K303.5. 1 AS FOLLOWS:
<br />A) OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED RIOT LESS THAN 10 FEET FROM ANY
<br />HAZARDOU5 OR NOXIOUS CONTAMINANT, EXCEPT WHERE THE INTAKE OPENING IS LOCATED 3
<br />FEET OK GREATER BELOW THE CONTAMINANT SOURCE
<br />B) EXHAUST AIR, SHALL NOT BE DIRECTED ONTO WALKWAYS.
<br />OUTSIDE AIR EXHAUST AND INTAKE OPENINGS SHALL BE PROTECTED IN ACCORDANCE WITH
<br />R303.G, AI\ID SHALL HAVE AUTOMATIC AND GRAVITY DAMPERS THAT CL05E WHEN THE
<br />VENTILATION SYSTEM IS NOT OPERATING.
<br />SOLID FUEL -BURNING APPLIANCES SHALL BE PKOVIDED WITH COMBUSTION AIR IN
<br />ACCORDANCE WITH SECTION M 170 1.
<br />PER IRC CHAPTER 15 TABLE M) 507.3.3(I) CONTINUOUS WHF MECH VENT
<br />SYSTEM AIRFLOW RATE KEQUIREMEHT5 FOR A HOUSE OF 4500-GOOO 5Q.FT.
<br />AREA AND FOR 5 BEDROOM WE NEED A AIRFLOW OF 120 CfM WHICH WILL BE 51TUATED ON
<br />FOR 2.4 HK5 A DAY,
<br />TOTAL CONDITIONED AREA = G805.0 Q.F T .
<br />CONTROLS OF WHF ARE LOCATED IN LAUNDRY ROOM.
<br />ALL THE HABITABLE ROOMS HAVE OPERABLE WINDOWS TO BRING THE OUTDOOR AIR IN,
<br />20, PROVIDE FAUCETS IN BATHROOMS WITH MAX. FLOW OF 1.0 GPM. OR LESS
<br />5HOWERHEAD AND KITCHEN 511,,IKS OF 1.75 GPM OK LESS.
<br />2 1. WATER. RESISTANT "DEN51-1IELD" OF, APPROVED ALT. (GWB) SHALL ONLY BE USED ON
<br />WALLS OF TUB AND SHOWER ENCLOSURES, OR WATER CLOSET COMPARTMENT WALLS.
<br />22.ALL SHOWER AREAS SHALL BE FINISHED WITH A SMOOTH NON-AB50RBENT MATERIAL TO
<br />A HEIGHT OF 70" ABOVE THE DRAIN INLET. THIS MATERIAL SHALL BE INSTALLED OVER A
<br />MATERIAL WHICH 15 NOT ADVERSELY AFFECTED BY MOISTURE.
<br />23.ATTIC ACCESS. PROVIDE 22" x 30" ATTIC ACCESS PER IRC K807, SEE DETAIL 1 3/A9,01 .
<br />R3 1 2.2. 1 WINDOW SILLS. IN DWELLING UNITS, WHERE THE TOP OF THE SILL OF AN
<br />OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR
<br />SURFACE BELOW, THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A
<br />MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOD, OF THE ROOM IN WHICH THE WINDOW
<br />15 LOCATED. OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW
<br />PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OFFNING5 ARE LOCATED WITHIN 24
<br />INCHES OF THE FINISHED FLOOK.
<br />LEGEND
<br />50 CFM FAN. SEE NOTE 18.
<br />g 100
<br />100 CFM FAN.
<br />PA G^✓NF
<br />WHOLE HOUSE FAN.
<br />5
<br />SMOKE DETECTOR5.5EE NOTE i G.
<br />CARBON MONOXIDE DETECTOR.
<br />SEE NOTE 17,
<br />WALL TYPE. SEE A9.01 FOR DETAILS
<br />ABBREVIATIONS
<br />CPT
<br />CARPET
<br />CONC
<br />CONCRETE
<br />DR
<br />DOOR
<br />(EG)
<br />EGRE55
<br />GL
<br />GLA55
<br />HDWD
<br />HARDWOOD
<br />5C
<br />SOLID CORE
<br />EG
<br />EGRESS WINDOW. SEE NOTE 1/A4.01
<br />SG
<br />SAFETY GLAZING, SEE NOTE 1 1.
<br />C5V
<br />CRAWL SPACE VENT
<br />DESIGN LYRIC
<br />9824 223RD PL NE
<br />REDMOND WA 98033
<br />PH: 206-853--9874
<br />REVISIONS;
<br />9/02/20 - COMMENTS FROM CITY
<br />11/11/?0 COMMENTS FROM CITY
<br />1/14/21 - COMMENTS FROM CITY
<br />APPROVALS:
<br />DESIGNED SS
<br />DRAWN IRS
<br />CHECKED SS
<br />DATE 6-01-2020
<br />SCALE AS NOTED
<br />PROJECT CLIENT:
<br />SARAMAhJJIT DHALIWR,L
<br />DHALIWAL RESIDENCE
<br />SHEET TITLE
<br />UPPER FLOOR PLAN
<br />CITY OF EVERETT
<br />REVIEWED FOR PERMIT