Laserfiche WebLink
1 <br />IA <br />MAX. BLDG HT. <br />+225.74' <br />T® OF THE ROOF� <br />+225.22' <br />SECOND FLR PL HT.... <br />+220, 72' <br />8 <br />ID <br />MAX. BLDG HT. <br />+225.74' <br />TOP OF THE ROOF <br />+225.22' <br />I <br />SECOND FLR PL HT. <br />+220.72' <br />+197.74' <br />I <br />2 { 3 1 { 5 1 { 7 <br />(: ) s 1!� �V�All�ON�� <br />SOUTH ELEVA110N <br />ALE. 3 <br />4 > "sc? /1 6 _ _ <br />LEGEND <br />SIDING <br />HARDIE PANELS <br />STONE <br />SCORING PANELS <br />EGRESS WINDOW - SEE NOTE 1. <br />SG SAFETY GLAZING. SEE NOTE 8 FOR DETAILS <br />1. EGRESS WINDOWS: (PER. IRC R310.1) <br />a. MINIMUM OPENING AREA = 5.7 SOFT (EXCEPTION: MIN. <br />OPENING ON MAIN FLOOR m 5.0 SFT). <br />b. MINIMUM OPENING HEIGHT o 24". <br />C. MINIMUM OPENING WIDTH e 20". <br />d. MAXIMUM 44" FINISHED SILL HEIGHT. <br />e. OPERABLE WITHOUT KEYS OR SPECIAL TOOLS. <br />2. VERIFY SHEAR WALL NAILING & HOLD DOWNS PER PLAN PRIOR <br />TO INSTALLING SIDING <br />3. CAULK ALL EXTERIOR JOINTS & PENETRATIONS, <br />PROVIDE APPROVED CORROSION RESISTANT FLASHING AT <br />EXTERIOR WALL ENVELOPE PER I.R.C. R703.8. <br />4. PROVIDE APPROVED MATERIAL FLASHING AT ROOF <br />PENETRATIONS PER I.R.C, R903.2 & R 903.2.1 <br />5. PROVIDE WEATHER STRIPPING AT ALL EXTERIOR & <br />GARAGE -INTERIOR DOORS. <br />6. PROVIDE CONTINUOUS GUTTER & DOWNSPOUTS @ ALL EAVE, <br />TYR <br />7. ADDRESS OR HOUSE NUMBER TO BE POSTED AND PLAINLY <br />VISIBLE FROM THE STREET FRONTAGE. <br />PROVIDE STAIRWAY ILLUMINATION PER I.R.C. R 303.6. <br />8. SAFETY GLAZING: AS PER IRC R308.4, SAFETY GLAZING <br />SHOULD BE INSTALLED AT THE FOLLOWING LOCATIONS. <br />ALL GLAZING IN THE FOLLOWING HAZARDOUS LOCATIONS SHALL <br />BE SAFETY GLAZING, WIRE GLASS, LAMINATED GLASS, <br />TEMPERED GLASS, OR SHATTER RESISTANT PLASTIC. <br />A. IN INGRESS AND EGRESS DOORS (INCLUDING ALL EXTERIOR <br />DOORS). <br />B. IN FIXED AND SLIDING PANELS OF SLIDING DOORS, OTHER <br />THAN WARDROBE DOORS. <br />C. IN ALL STORM DOORS. <br />D. IN ALL NON -FRAMED SWINGING DOORS. <br />E. IN ALL SHOWER AND TUB DOORS AND ENCLOSURES. <br />F. ALL, OPERABLE OR INOPERABLE, WITHIN 24" RADIUS OF A <br />DOOR IN A CLOSED POSITION WHOSE BOTTOM EDGE IS 60" OR <br />LESS ABOVE THE WALKING SURFACE (LEADED OR FACETED <br />GLASS IS ACCEPTABLE HERE). <br />G. IN FIXED PANELS, OTHER THAN THOSE COVERED IN <br />SECTION 'F' ABOVE WHICH HAVE A GLAZED AREA IN EXCESS OF <br />NINE (9) SQUARE FEET AND THE LOWEST EDGE IS LESS THAN 18" <br />ABOVE THE FLOOR LEVEL OR WALKING SURFACE. IN LIEU OF <br />SAFETY GLAZING, SUCH BLAZED PANELS MAY BE PROTECTED <br />WITH A HORIZONTAL MEMBER OF NOT LESS THAN 1.5" IN WIDTH <br />LOCATED BETWEEN 24" AND 36" ABOVE THE WALKING SURFACE <br />LEADED OR FACETED GLASS IS ACCEPTABLE HERE). <br />09. HANDRAIL MUST NOT PROJECT MORE THAN 4 1/2" INTO THE <br />PATIO AND MUST BE ABLE TO RESIST A 200 LBS LOAD FROM ANY <br />DIRECTION, IRC SECTION R311.5 & TABLE R301.5. <br />PER SEC R312.1.3 CONTRACTOR TO MAKE SURE REQUIRED <br />GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING <br />SURFACE TO THE REQUIRED GUARD HEIGHT THAT ALLOW <br />PASSAGE OF A SPHERE 4" (102mm) IN A DIAMETER. <br />10. CONTRACTOR TO MAKE SURE THAT HE FOLLOWS BUILDING <br />HEIGHT & FLOOR LEVELS MENTIONED TO BE VERIFIED BY <br />SURVEYOR AT ALL STAGES, TO ENSURE THAT THE BUILDING <br />STAYS IN ALLOWED HEIGHT. <br />DESIGN LYRIC <br />9824 223RD PL NE <br />REDMOND WA 98053 <br />PH: 206-853-9874 <br />REVISIONS: <br />9/02/20 - COMMENTS FROM CITY <br />11/11/20 - COMMENTS FROM CITY <br />1/14/21 - COMMENTS FROM CITY <br />PROJECT CLIENT: <br />SARAfUTANJiT DHALiWAL <br />PFtOJECT: <br />C#1ALIWAL RESIDENCE <br />SHEET TITLE <br />BUILDING ELEVATIONS <br />CITY OF EVERETT <br />REVIEWED FOR PERMIT <br />05092019 <br />