SITE PLAN <br />SCALE: 1 "=80'-O" 0 40' 80' 160' <br />NOTES: <br />1. ALL SYSTEM CONTROL VALVES TO BE MONITORED, <br />2, EFFECTIVE POINT OF WATER FLOW TEST DATA SHALL BE UTILIZED, NO OTHER LOCATIONS <br />WILL BE ACCEPTABLE PER OWNER REQUIREMENTS. <br />)VICINITY MAP <br />-SCALE: NTS <br />EVERETT DELIVERY CENTER <br />SCALE: NTS <br />IVLYY VI"IIV VI I. JLL JIILLI '. <br />FP2.0 FOR MORE DETAIL. <br />CON TRACTOR - �/E-RrF fl <br />- - -- <br />EXTENT OF WORK. <br />CONSULTING <br />7611 re€frdvwx,xdf Avert: ep, #C(Yl <br />mo ttle,WA 9810u <br />pn6lmgrolffs <br />nrg fiferan0,UIfingxol'n^ <br />© MG2. All rights reserved. No part of this document may be <br />reproduced in any form or by any means without permission in <br />writing from MG2. <br />m <br />6617 ASSOCIATED BLVD <br />EVERETT, WA 98203 <br />• <br />1, SPRINKLER PLANS ARE SCHEMATIC AND SHALL NOT BE MEANT TO CONVEY OR <br />ALLOW DISCREPANCY BETWEEN THE WORK ILLUSTRATED HEREIN AND ALL APPLICABLE <br />CODES, PLANS AND ORDINANCES. IT SHALL BE THE RESPONSIBILITY OF THE SPRINKLER <br />CONTRACTOR TO VERIFY ACTUAL CONDITIONS OF CONSTRUCTION AND TO MAINTAIN <br />CONFORMANCE TO THE REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION. <br />DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT OR OWNER'S <br />REPRESENTATIVE PRIOR TO BID. <br />2. ALL INSTALLATIONS SHALL CONFORM TO THE REQUIREMENTS OF NFPA 13, THE <br />AUTHORITIES HAVING JURISDICTION, THE OWNERS' INSURANCE CARRIER, THE TRUSS <br />MANUFACTURER AND STRUCTURAL ENGINEER, AND THE OWNERS' REVIEWING CONSULTANT. <br />3. ALL MATERIALS USED SHALL BE UL LISTED AND APPROVED. <br />4. SYSTEMS SHALL BE MONITORED BY AN OFF SITE CENTRAL STATION. z <br />5. INSTALLATION AND FABRICATION SHALL NOT COMMENCE UNTIL PLANS AND <br />CALCULATIONS ARE APPROVED BY ALL AUTHORITIES MENTIONED ABOVE OR WORK WILL BE <br />DONE "AT RISK" AND WILL BE THE RESPONSIBILITY ON THE SPRINKLER CONTRACTOR TO <br />RECTIFY AT NO COST TO THE OWNER. <br />6. AT VARIOUS STAGES, AND/OR UPON COMPLETION, THE SYSTEMS MUST BE TESTED <br />IN THE PRESENCE OF THE ENFORCING AGENCY. z <br />7. PENETRATIONS OF RATED ASSEMBLIES SHALL BE FIRE STOPPED WITH AN APPROVED <br />MATERIAL AS PRESCRIBED BY THE AHJ. 0 <br />8. ALL HANGER TYPES, SIZES, AND METHODS OF ATTACHMENT MUST MEET <br />REQUIREMENTS OF REVIEWING AUTHORITIES MENTIONED ABOVE. <br />9, SEE FIRE SPRINKLER SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS AND <br />INFORMATION, THE SPRINKLER CONTRACTOR SHALL COORDINATE ALL SITE INFORMATION <br />WITH ARCHITECT AND CIVIL ENGINEER. <br />10. SPRINKLER CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED <br />CONSTRUCTION PRACTICES, SPRINKLER CONTRACTOR WILL BE REQUIRED TO ASSUME SOLE <br />AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF <br />CONSTRUCTION OF THE PROJECT, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY. <br />THIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO <br />NORMAL WORKING HOURS, SPRINKLER CONTRACTOR FURTHER AGREES TO DEFEND, <br />INDEMNIFY, AND HOLD DESIGN PROFESSIONAL HARMLESS FROM ANY AND ALL LIABILITY, 0 <br />REAL OR ALLEGED, IN CONNECTION WITH THE PERFORMANCE OF WORK ON THIS PROJECT. _ <br />11. CAUTION: THE ENGINEER PREPARING THESE PLANS WILL NOT BE RESPONSIBLE FOR Z o>� O .J <br />UNAUTHORIZED CHANGES TO OR USE OF THESE PLANS. ALL CHANGES TO THE PLANS <br />MUST BE SUBMITTED IN WRITING AND MUST BE APPROVED BY THE PREPARER OF THESE < r W In <br />PLANS. ry W <br />12, THE ENGINEER OF DESIGN SHALL NOT BE RESPONSIBLE FOR THE SPRINKLER 0 ® N <br />CONTRACTORS' FAILURE TO CARRY OUT THE CONSTRUCTION WORK IN ACCORDANCE WITH w 00 <br />THE CONTRACT DOCUMENTS, NOR SHALL HE BE REQUIRED TO SUPERVISE THE CONDUCT 0) <br />OF THE WORK OR THE CONSTRUCTION PROCEDURES FOLLOWED BY THE CONTRACTOR, OR <br />SUBCONTRACTORS, OR THEIR RESPECTIVE EMPLOYEES OR BY ANY OTHER PERSON AT THE VJ <br />JOB SITE OTHER THAN THAT OF THE ENGINEERING FIRMS' EMPLOYEES. <br />13. FIRE SPRINKLER SHOP DRAWINGS, WITH DETAILS SHOWING HANGERS, FASTENERS, L1.i <br />AND ATTACHMENT METHODS AND SIZES, SHALL BE SUBMITTED TO THE TRUSS 0 <br />Uj r� 0 <br />MANUFACTURER AND STRUCTURAL ENGINEER FOR APPROVAL. A LETTER OF APPROVAL W <br />SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE PRIOR TO FINAL ACCEPTANCE <br />BY OWNER. THE DETAILS SHALL INCLUDE ALL HANGERS, AND EARTHQUAKE BRACING ry z <br />ATTACHMENTS. < � Q <br />14, IT IS THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR TO FAMILIARIZE h <br />THEMSELVES WITH THE BID SPECIFICATION DOCUMENTS, AND TO BRING ANY POTENTIAL 0 <br />CONFLICTS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BID. M� <br />15. CORRECT SPRINKLER LOCATIONS AND/OR QUANTITIES DUE TO NEW/EXISTING Uj W 8o <br />OBSTRUCTIONS IS THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR. COORDINATE <br />PIPING WITH ALL OTHER TRADES AND REVIEW ALL OTHER TRADES DRAWINGS. <br />CONTRACTOR SHALL PLACE IN THEIR BID AS A SEPARATE LINE ITEM EXTRA QUANTITIES -.I- <br />OF SPRINKLERS, PIPING, FITTINGS, HANGERS, OTHER ASSOCIATED EQUIPMENT/MATERIALS DESCRIPTION A DATE <br />AND LABOR. COST OF EXTRA ITEMS INDICATED SHALL BE ACCOUNTED FOR AT TIME OF QAREVIEW SET - 05/22/2020 <br />BID, CONTRACTOR WILL NOT BE AWARDED COST OF EXTRA ITEMS, UNLESS OWNER <br />CHANGES INDICATED OTHERWISE. ANY ADDITIONAL WORK (DESIGN, FABRICATION, OR 90% QA REVIEW SET - 06/19/2020 <br />INSTALLATION) SHALL BE APPROVED PRIOR TO COMMENCEMENT OF ADDITIONAL CHANGES, PERMIT SET - 09/17/2020 <br />NO EXCEPTIONS. <br />16. ALL PERMITS ARE THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR. <br />17. FLUSH CONNECTIONS SHALL BE PROVIDED PER NFPA 13. <br />18. ALL DEFLECTOR DISTANCE REQUIREMENTS OF NFPA 13 MUST BE COMPLIED WITH <br />19. CRIMP TYPE INSTALLATIONS ARE NOT ACCEPTABLE. <br />20. THE SPRINKLER CONTRACTOR SHALL COORDINATE ALL SITE INFORMATION WITH <br />ARCHITECT AND CIVIL ENGINEER. <br />21. THE SPRINKLER CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF NFPA 13 <br />"PROTECTION OF PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". THE _ <br />SPRINKLER CONTRACTOR MUST ALSO TAKE INTO ACCOUNT THE LIMITATIONS OF THE <br />STRUCTURAL ELEMENTS PRIOR TO SIZING, FASTENING AND/OR LOCATING SEISMIC <br />ASSEMBLIES, RESTRAINTS, ETC, ON THEIR PLANS. STRUCTURAL REQUIREMENTS AND <br />LIMITATIONS MAY BE MORE STRINGENT THAN NFPA. NO ADDITIONAL COMPENSATION FROM <br />OWNER RELATING TO THE SPRINKLER CONTRACTORS FAILURE TO CONSIDER AND <br />COORDINATEWITH THE STRUCTURAL ENGINEER AS IT RELATES TO LOAD, FASTENING <br />METHODS, LOCATION ETC OF ALL SEISMIC CONNECTIONS TO THE STRUCTURE WILL BE <br />CONSIDERED. <br />22. AS PART OF THE OWNER'S CLOSE OUT DOCUMENTS, THE SPRINKLER CONTRACTOR <br />SHALL REVISE THEIR PLANS AND ISSUE AN "AS -BUILT" (IN COMPLIANCE TO NFPA 13) <br />AS -BUILT PLANS SHALL HAVE ALL NOTES REMOVED THAT REFERENCE "CONTRACTOR TO <br />VERIFY" ETC. AS THESE ARE INSTRUCTIONS TO THE SPRINKLER CONTRACTOR FOR THEIR <br />SCOPE OF WORK. AS -BUILT PLANS SHALL HAVE CONSULTING/NRG INFORMATION <br />REMOVED (EXCEPT FLOW TEST/PUMP TEST DATA) FROM THEIR PLANS PRIOR TO <br />ISSUANCE. 1 SET OF AS -BUILT PLANS SHALL REMAIN ON SITE AND PLANS, <br />CALCULATIONS, ETC. <br />APPLICABLE BUILDING CODES <br />INTERNATIONAL BUILDING CODE 2015 <br />INTERNATIONAL FIRE CODE 2015 <br />APPLICABLE STANDARDS: <br />NFPA 13 2013 <br />PROJECT STATUS <br />SHEET INDEX <br />SHEET SHEET NAME <br />NUMBER <br />FP1.0 FIRE PROTECTION SITE PLAN AND NOTES <br />FP2.0 FIRE PROTECTION PARTIAL PLAN <br />JOB NUMBER <br />20574401B <br />DRAWN BY CHECKED BY <br />A. HOLTON R. ANDERSON <br />SHEET TITLE <br />FIRE PROTECTION <br />SITE PLAN AND <br />NOTES <br />SHEET NUMBER <br />FP1 wO <br />