6001 BROADWAY 2022 Plans 2022-10-24
>
Address Records
>
BROADWAY
>
6001
>
Plans
>
6001 BROADWAY 2022 Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 9:00:37 AM
Creation date
10/24/2022 8:58:12 AM
Metadata
Fields
Template:
Address Document
Street Name
BROADWAY
Street Number
6001
Permit
B2203-004
Year
2022
Notes
CHANGE (3) BEDROOM DOORS, ADD SHOWER & TOILET GRAB BARS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit #: B2203-004 <br />Site Address: 6001 BROADWAY <br />Ionr0-01 <br />IN1111in! � <br />f' OFOSED 5EDF,00F DOOR LA0 � NT <br />FrO <br />5'151� C" c-1F-I-tSi <br />OV�NER <br />TEfiERA EYASU � BEYENE BILEN <br />6001 E3R0,4DWAY A\lE SE , <br />E\/ERETT, WA 1�8205 <br />5 1 TE ADL;)RESS <br />6001 i " • <br />- - - cfa205 <br />0-0, 10M ii <br />5iiW 1110011 1 _8 <br />PTO =-A** <br />THESE DOCUMENTS HAVE <br />NOT SEEN APPROVED FOR THE <br />ISSUANCE OF PUBLIC WORKS, <br />MECHANICAL, FIRE SUPPRESSION, <br />ELECTRICAL OR PLUMBING PERMITS. <br />All electrical, mechanical, plumbing <br />and framing installed/altered without <br />permit, inspection, and approval must <br />be uncovered for inspection. <br />CITY OiF iEVERETT <br />REVIEWED FOR PERM17- <br />Smoke Detectors Required <br />• in each sleeping room, <br />• In each room giving access to a <br />sleeping room, <br />• Interconnected, <br />• Battery backup, <br />• Hardwired, <br />A ( <br />Owner: TEFERA EYASU & BEYENE 13ILEN <br />Tenant: [TenNamel <br />App.Date: 3/1/2022 <br />Proposed Use: RESIDENTIAL ALTERATIONS <br />Description: CHANGE (3) BEDROOM DOORS, ADD <br />SHOWER & TOILET GRAB BARS <br />GENERAL NOTES <br />CODE Reviewer <br />DESIGN IS IN ACCORDANCE WITH THE 2018 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) <br />Offio <br />FOUNDATIONS <br />EXTEND FOOTINGS TO FIRM UNDISTURBED SOIL, ASSUMED BEARING CAPACITY OF 1500 PSF. ALL <br />EXTERIOR FOOTINGS SHALL EXTEND A MINIMUM OF V-6" BELOW ADJACENT EXTERIOR FINISHED GRADE. <br />CAST -IN -PLACE CONCRETE <br />Pc = 3,000 PSI @ 28 DAYS. MINIMUM 5-1/2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A <br />EE <br />MAXIMUM OF 6-3/4 GALLONS OF WATER PER 94# SACK OF CEMENT. NO SPECIAL INSPECTION REQUIRED. <br />TOTAL AIR ENTRAINMENT SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. MAXIMUM <br />SIZED AGGREGATES IS 1-1/2 INCHES. MAXIMUM SLUMP IS 4 INCHES. ALL REINFORCING STEEL DOWELS, <br />ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONCRETE. <br />ANCHOR BOLTS FOR PRESSURE TREATED SILL PLATES TO FOUNDATION WALLS TO BE 5/" DIAMETER WITH Cl <br />7 INCH MINIMUM EMBEDMENT INTO CONCRETE AND MAXIMUM SPACING OF 2 FEET ON CENTER UNLESS Per <br />NOTED OTHERWISE ON THE PLANS. MINIMUM 2 BOLTS PER SILL PLATE PIECE. ONE BOLT TO BE PLACED <br />WITHIN 6 INCHES OF EACH END OF THE SILL PLATE. <br />CARPENTRY <br />ALL GRADES SHALL CONFORM TO WWPA GRADING RULES FOR WESTERN LUMBER, LATEST EDITION. <br />PROVIDE CUT WASHERS UNDER ALL NUTS AND BOLTS BEARING AGAINST WOOD. ALL WOOD IN CONTACT <br />WITH CONCRETE SHALL BE PRESSURE TREATED PER PRESERVATIVE TREATMENT NOTE. FASTENERS <br />INSTALLED IN PRESERVATIVE TREATED WOOD SHALL BE HOT -DIPPED GALVANIZED PER I.R.C. SECTION <br />R319.3. NAILING SHALL CONFORM WITH I.R.C. TABLE R602.3(1) & R802.10 OR I.B.C. TABLE 2304.9.1. ALL <br />STRUCTURAL LUMBER SHALL BE AS NOTED BELOW: <br />2x STUDS HEM -FIR #2------------------ Fb = 850 PSI <br />2x FLOOR & ROOF JOIST HEM -FIR #2---------- -------- Fb = 850 PSI <br />4x BEAMS DOUG-FIR/LARCH #2---------- Fb = 875 PSI <br />6x BEAMS DOUG-FIR/LARCH #2---------- Fb = 850 PSI <br />COLUMNS DOUG-FIR/LARCH #2---------- Fb = 875 PSI <br />LUMBER NOT NOTED DOUG-FIR/LARCH #2---------- Fb = 850 PSI <br />MISCELLANEOUS HANGERS TO BE PROVIDED BY SIMPSON COMPANY. ALL HANGERS SHALL BE FASTENED <br />TO WOOD WITH PROPER NAILS. ALL HOLES SHALL BE NAILED. MACHINE BOLTS TO BE A-307. ANCHOR <br />BOLTS INTO CONCRETE SHALL BE 5/" DIAMETER WITH 7 INCHES OF EMBEDMEND INTO CONCRETE UNLESS <br />NOTED OTHERWISE ON THE PLANS., ALL NAILS SHALL BE COMMON WIRE NAILS. NAILING SHALL BE IN <br />ACCORDANCE WITH I.B.C. SCHEDULE, 16d COMMON NAIL DIAMETER - (0.162 INCH). LAMINATED STUDS <br />SHALL BE NAILED WITH (2) ROWS 16d COMMON NAILS @ 6" O.C. <br />FLOOR SHEATHING <br />SHEATHING SHALL BE % INCH TONGUE & GROOVE, A.P.A. RATED SHEATHING. SPAN RATING 4%4 WITH <br />LONG DIMENSION PERPENDICULAR TO SUPPORTS. UNLESS NOTED OTHERWISE NAIL WITH 10d COMMON <br />NAILS AT 6 INCHES ON CENTER AT SUPPORTED PANEL EDGES & 10 INCHES ON CENTER AT INTERMEDIATE <br />SUPPORTS. THE FLOOR SHEATHING SHALL BE GLUED TO THE JOIST AND THE TONGUE AND GROOVE <br />JOINTS WITH AN APPROVED ADHESIVE. <br />ROOF SHEATHING <br />SHEATHING SHALL BE 7/6" A.P.A. RATED SHEATHING. SPAN RATING 33/16, INSTALLED WITH LONG DIMENSION <br />ACROSS SUPPORTS. PANEL END JOINTS SHALL OCCUR AT SUPPORTS. NAIL PANEL EDGES WITH 8d NAILS <br />AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT INTERMEDIATE SUPPORTS. <br />WALL SHEATHING <br />SHEATHING TO BE %s' A.P.A. RATED SHEATHING. SPAN RATING 24/. PANEL END JOINTS SHALL OCCUR AT <br />SUPPORTS. NAIL PANEL EDGES WITH 8d NAILS AT 4 INCHES ON CENTER AND 10 INCHES ON CENTER AT <br />INTERMEDIATE SUPPORTS UNLESS NOTED OTHERWISE ON THE DRAWINGS. <br />REINFORCEMENT <br />fy = 40,000 PSI FOR #5 & SMALLER <br />fy = 60,000 PSI FOR #6 & LARGER <br />NOTE: ALL BOLTS, WASHERS, NAILS, SCREWS, HANGERS AND FRAMING STRAPS THAT COME INTO <br />CONTACT WITH ACQ TREATED LUMBER SHALL BE STAINLESS STEEL OR HOT -DIPPED GALVANIZED STEEL. <br />WALL NOTES: <br />NAIL SPACING <br />TOP/BOTTOM <br />NEW 2X6 <br />NAIL <br />EXTERIOR WALL <br />SIZE <br />EDGES <br />STUDS <br />PLATE <br />8d <br />6" <br />12" <br />6" <br />1. %6 A.P.A. RATED PLYWOOD OR ORIENTATED STRAND BOARD (O.S.B.) <br />ON ONE SIDE OF WALL. NAILS SHALL BE 8d COMMON (0.131" <br />DIAMETER). <br />2. ALL PANEL EDGES BLOCKED WITH 2-INCH NOMINAL FRAMING. INSTALL <br />PANELS EITHER HORIZONTALLY OR VERTICALLY FOR PLYWOOD OR <br />A.P.A. RATED SHEATHING, GYPSUM SHEAR WALLS SHALL BE <br />INSTALLED WITH THE SHEETS RUNNING HORIZONTALLY. SPACE NAILS <br />@ 12 INCHES ON CENTER @ INTERMEDIATE SUPPORTS. <br />3. 5/" DIAMETER ANCHOR BOLTS SHALL BE 10 INCHES LONG SPACED A <br />MAXIMUM OF 24 INCHES ON CENTER. WASHERS TO BE GALVANIZED <br />OR STAINLESS STEEL. <br />4. REFER TO PLANS AND SECTIONS FOR ANCHOR BOLT SIZES, SPACING, <br />PLATE & NAILING ETC. <br />INDEX OF DRAWINGS <br />SHEET # DESCRIPTION <br />AO <br />SITE PLAN <br />Al <br />COVERSHEET <br />A2 <br />EXISTING LOWER FLOOR AND MAIN FLOOR <br />0 S I R <br />A4 <br />NAILING CHART AND GRAB BARS <br />y 1 <br />i By:1J� Date: <br />Set Job Site Set Fire/Planning Set <br />OF EVERETT <br />nit Services <br />W <br />r <br />a� <br />O <br />ct <br />�W <br />Q�W <br />UO)> <br />CD <br />-�J <br />CD <br />z <br />O <br />W <br />F- <br />_J <br />d <br />L.L. <br />►� a_ <br />W <br />CD F— <br />z <br />Document date: <br />Revisions: <br />0- REVISION DUE TO <br />COMMEN DATED <br />3/24/22 <br />Z <br />D <br />W <br />J <br />CO <br />� <br />W <br />W <br />z <br />W <br />W <br />w L.L <br />W <br />m <br />U <br />I- <br />06 <br />APPROVED <br />Office of Community, Planning & Economic Development <br />PLANNING DEPARTMENT <br />Name 11t/ A k P l DATE:3 1iLA 1 <br />OF A4 <br />