REVISIONS
<br />N
<br />fN"'V VICINITY MAP
<br />NO SCALE
<br />PROJECT LOCATION
<br />PROVIDENCE REGIONAL MEDICAL CENTER EVERETT
<br />ROOFTOP DECK
<br />EVERETT, WA
<br />PROVIDENCE REGIONAL MEDICAL CENTER EVERETT
<br />1321 COLBY AVENUE
<br />EVERETT, WA 98201
<br />425.218.0919
<br />JAMES GRAFTON
<br />ARCHITECT
<br />NAC ARCHITECTURE
<br />1203 WEST RIVERSIDE AVENUE
<br />SPOKANE, WA 99201
<br />509.838.8240
<br />MICHAEL O'MALLEY
<br />STRUCTURAL ENGINEER
<br />COUGHLIN PORTER LUNDEEN (CPL)
<br />801 2ND AVENUE, SUITE 900
<br />SEATTLE, WA 98104-1515
<br />206.343.0460
<br />REBECCA HIX COLLINS P.E., S.E., LEER AP
<br />MECHANICAL ENGINEER
<br />COFFMAN ENGINEERS
<br />1101 2ND AVENUE, SUITE 400
<br />SEATTLE, WA 98101-3657
<br />206.521.0706
<br />OYVIND NAESS, P.E.
<br />ELECTRICAL ENGINEER
<br />STANTEC CONSULTING SERVICES, INC
<br />4100 194TH STREET SW SUITE 400
<br />INDEX OF DRAWINGS
<br />GENERAL MECHANICAL
<br />GO.01 COVER SHEET POA LEGEND & NOTES
<br />PG.2 MECHANICAL SPECIFICATIONS
<br />P1.1 LEVEL 6 - PLUMBING DEMO & PLAN
<br />ARCHITECTURAL ELECTRICAL
<br />A2.06 SIXTH FLOOR DEMOLITION PLAN
<br />EO.00 SYMBOLS, ABBREVIATIONS, AND DRAWING LIST
<br />A3.05 FIFTH FLOOR PLAN EO.01 ELECTRICAL SPECIFICATIONS
<br />A3.06 SIXTH FLOOR PLAN E1.60 C-WING ROOF - ELECTRICAL DEMOLITION PLAN
<br />E3.50 C-WING PENTHOUSE - ELECTRICAL PLAN
<br />A4.01 BUILDING SECTIONS & EXTERIOR ELEVATION E3.60 C WING ROOF - ELECTRICAL PLAN AND LIGHTING FIXTURE SCHEDULE
<br />E8.22 POWER RISER DIAGRAM WINGS B & C
<br />A5.01 DETAILS E9.00 PANEL SCHEDULES AND LOAD SUMMARIES
<br />STRUCTURAL
<br />S1.01
<br />GENERAL STRUCTURAL NOTES
<br />S1.02
<br />GENERAL STRUCTURAL NOTES
<br />S2.05
<br />FIFTH FLOOR FRAMING
<br />S2.06
<br />SIXTH FLOOR FRAMING
<br />S5.01
<br />DETAILS
<br />S5.02
<br />DETAILS
<br />Permit #:
<br />B2103-066
<br />Site Address:
<br />1321 COLBY AVE
<br />Owner:
<br />PROVIDENCE HEALTH & SERVICES -WA
<br />Tenant:
<br />PRMC-BEHAVORIAL HEALTH
<br />App. Date:
<br />3/23/2021
<br />Proposed Use:
<br />COMMERCIAL ALTERATIONS
<br />Description:
<br />RENO OF EXTG HELIPAD TO BE AN
<br />ENCLOSED ROOFTOP DECK
<br />Reviewed By:
<br />Date:
<br />_Office Set
<br />Job Site Set Fire/Planning Set
<br />LYNNWOOD, WA 98036
<br />,. 206.667.0553 "EOVE
<br />0: st 21st StMAUREEN JACKSON, P.E.
<br />N NOV 2 2 2021
<br />CONTRACTOR/CONSTRUCTION MANAGER m®r�_,
<br />LOCATION MAP
<br />MORTENSON CITY OF EVERETT
<br />10230 NE POINTS DRIVE, SUITE 300 Permit Services
<br />N0 SCALE KIRKLAND, WA 98033
<br />425-895-9000
<br />ERIN ERWIN
<br />ARCHITECTURAL SYMBOLS ARCHITECTURAL MATERIALS APPROV DOCUMENTS IHAVE SSUANCE BEEN
<br />OF
<br />OR THE ISSUANCE
<br />ABBREVIATIONS ABBREVIATIONS ABBREVIATIONS ABBREVIATIONS ABBREVIATIONS PUBLIC WORK, MECHANICAL FIRE
<br />SUPPRESSION
<br />� CENTERLINE
<br />PLUMBING PERMI SCTRICAL OR
<br />L ANGLE D DEEP, DEPTH GA GAUGE N NORTH S SOUTH DETAIL INDICATIONS
<br /># POUND OR NUMBER DBL DOUBLE GALV GALVANIZED NAT NATURAL SC SOLID CORE 77777771 ACOUSTIC TILE OR BOARD
<br />& AND DEMO DEMOLISH, DEMOLITION GB GRAB BAR NIC NOT IN CONTRACT SCD SEAT COVER DISPENSER / ___ _ GRID LINE
<br />AT DET DETAIL GEN GENERAL NO NUMBER SCHED SCHEDULE @ \ A ASPHALT CONCRETE PAVING
<br />° DEGREE DF DRINKING FOUNTAIN GI GALVANIZED IRON NOM NOMINAL SD SOAP DISPENSER �
<br />± PLUS / MINUS DIA DIAMETER GL GLASS NTS NOT TO SCALE SDG SIDING ROOFING
<br />H DIAMETER DIAG DIAGONAL GLB GLUE LAMINATED BEAM SECT SECTION DOOR IDENTIFICATION
<br />DIM DIMENSION GLZ GLAZING O/S OUTSIDE SHR SHOWER BRICK
<br />A/C AIR CONDITIONING DISP DISPOSAL GMU GLAZED MASONRY UNIT OA OVERALL SHT SHEET RELITE IDENTIFICATION
<br />AB ANCHOR BOLT DIV DIVISION GND GROUND OBS OBSCURE SHTG SHEETING / SHEATHING CAULKING OR SEALANT
<br />AC ASPHALT CONCRETE DIN DOWN GR GRADE OC ON CENTER SIM SIMILAR ® WINDOW TYPE CERAMIC TILE
<br />ACOUS ACOUSTICAL DP DAMPPROOF(ING) GYP GYPSUM BOARD (SCHEDULES ONLY) OCC OCCUPANT, OCCUPANCY SLR SEALER VERE" FIRE DE AD AREA DRAIN DR DOOR GYP BD GYPSUM BOARD OD OUTSIDE DIAMETER (DIM) SND SANITARY NAPKIN DISPENSER PT. %�
<br />ADDL ADDITIONAL DS DOWNSPOUT OFCI OWNER FURNISHED CONTRACTOR SNR SANITARY NAPKIN RECEPTACLE # LOUVER TYPE CONCRETE
<br />PPRpVED
<br />ADJ ADJUSTABLE DSP DRY STANDPIPE H HIGH INSTALLED SPEC SPECIFICATION APPROVED
<br />ADJT ADJACENT DWG DRAWING HB HOSE BIB OFF OFFICE SQ SQUARE PRECAST CONCRETE w �NANGiES D
<br />AFF ABOVE FINISHED FLOOR DWR DRAWER HC HOLLOW CORE, HANDICAP (ACCESSIBLE) OFOI OWNER FURNISHED OWNER INSTALLED SS STAINLESS STEEL, SOLID SURFACE ❑ REY�s RieSliBlKili
<br />AGGR AGGREGATE HD HEAD OH OVERHEAD SSK SERVICE SINK SEE
<br />CONCRETE MASONRY UNIT [)gEEA
<br />AJ ACCENT JOINT E EAST HDW HARDWARE OHD OVERHEAD DOOR STD STANDARD 1ED CNEC"T/HANDOUT
<br />AL ALUMINUM EA EACH HDWD HARDWOOD OPNG OPENING STL STEEL REVISION The issuance
<br />ALT ALTERNATE EHD ELECTRIC HAND/ HAIR DRYER HORIZ HORIZONTAL OPP OPPOSITE STN STAIN �y iul= EARTH/FINISH GRADE n(;e of a
<br />be Construed as permit Shah not
<br />ANC ANCHOR(AGE) EJ EXPANSION JOINT HS HAND SANITIZER ORIG ORIGINAL STOR STORAGE GLASS cancel authority to violate,
<br />eor
<br />ANOD ANODIZED EL ELEVATION HSS HOLLOW STEEL SECTION STRFT STOREFRONT set aWde any provision of
<br />AO AUTO OPENER ELEC ELECTRICAL HT HEIGHT PAR PARALLEL STRUCT STRUCTURAL v, GRAVEL the Everett Fire Code or
<br />_ regulations
<br />SUB SUBSTITUTE MATCH LINE applicable
<br />APC ACOUSTICAL PANEL CEILING ELEV ELEVATOR HTG HEATING PB PEG BOARD � � $uiat�OnS or laws. The '
<br />APF ACOUSTICAL PANEL FABRIC EM ENTRY MAT HVAC HEATING/ VENTILATING/ AIR PC PRECAST SUSP SUSPENDED Shaded area is side considered GYPSUM BOARD Issuance -of a permit biased on
<br />APPD APPROVED EMB ENAMELIZED MARKING BOARD CONDITIONING PCC PORTLAND CEMENT CONCRETE SV SHEET VINYL Construct•
<br />APPROX APPROXIMATE EMER EMERGENCY HWH(T) HOT WATER HEATER (TANK) PCD PAPER CUP DISPENSER SWC SANITARY WALL COVERING INSULATION, GATT El>�1 d°cumeMs and other
<br />ARCH ARCHITECTURAL ENCL ENCLOSURE PERF PERFORATED G� WORK POINT DATUM POINT, data shall not
<br />SYM SYMMETRICAL CONTROL POINT INSULATION, RIGID Off ical fr Prevent the Fire Code
<br />ASB ASBESTOS EP ELECTRICAL PANELBOARD, EPDXY PAINT US INSIDE PERP PERPENDICULAR SYS SYSTEM Om requiring the
<br />ASPH ASPHALT EPT EPDXY PAINT ID INSIDE DIAMETER (DIM) PL PLATE of errors.. correction
<br />AUTO AUTOMATIC EQ EQUAL INCL INCLUDE PLAM PLASTIC LAMINATE T TREAD, TEE 4 ® METAL
<br />AWP ACOUSTICAL WALL PANEL EQUIP EQUIPMENT INFO INFORMATION PLAS PLASTER TB TOWEL BAR, TACK BOARD A5.1 DETAIL By: >�
<br />EW EYEWASH INSUL INSULATION PLUMB PLUMBING TC TOP OF CURB Upper mark denotes drawing number METAL LATH Date t�
<br />BD BOARD EWC ELECTRIC WATER COOLER INT INTERIOR PLYWD PLYWOOD TEL TELEPHONE 3SIM Lower mark denotes sheet
<br />BET BETWEEN EXC EXCAVATE INTERCOM INTERCOMMUNICATION PNL PANEL TEMP TEMPORARY _ MORTAR, PLASTER, SAND
<br />BITUM BITUMINOUS EXH EXHAUST IRD IMPACT RESISTANT DOOR POL POLISHED TERR TERRAZZO A dash in the sheet reference location
<br />indicates that the detail occurs on the 7/1 BLDG BUILDING EXIST EXISTING POS POSITIVE TF TOP OF FOOTING same sheet that it is flagged PLYWOOD
<br />BLK BLOCK EXP EXPOSED, EXPANSION JAN JANITOR PR PAIR THK THICK
<br />BLKG BLOCKING EXT EXTERIOR JST JOIST PREFAB PREFABRICATE(D) THRU THROUGH ® WOOD, FINISH
<br />BM BEAM JT JOINT PREFIN PREFINISH(ED) TOF TOP OF FRAME
<br />BOF BOTTOM OF FRAME F FILE (DRAWER) PROJ PROJECT TOM TOP OF MASONRY ® WOOD FRAMING
<br />BOM BOTTOM OF MASONRY FA FIRE ALARM KIT KITCHEN PS PROJECTION SCREEN TP TOP OF PAVEMENT Continuous member
<br />BOTT BOTTOM FAB FABRICATE PT POINT, PAINT TPD TOILET PAPER DISPENSER
<br />BRG BEARING FD FLOOR DRAIN L LENGTH, LONG PTD PAPER TOWEL DISPENSER TR TOWEL RACK PARTIAL BUILDING SECTION
<br />A4.5 ® WOOD FRAMING
<br />BSMT BASEMENT FDN FOUNDATION LAB LABORATORY PTDR COMBINATION PAPER TOWEL DISPENSER TS TUBE STEEL TYP Interrupted member
<br />BUR BUILT UP ROOF FE FIRE EXTINGUISHER LAM LAMINATE & RECEPTACLE
<br />FEC FIRE EXTINGUISHER CABINET RECESSED LAV LAVATORY PTN PARTITION TV TELEVISION
<br />(RECESSED) TTELEVISION BRACKET A A BUILDING CROSS SECTION PLAN INDICATIONS
<br />C COURSES FEC-S FIRE EXTINGUISHER CABINET L!N LINOLEUM PTR PAPER TOWEL RECEPTACLE TW TOP OF WALL
<br />CAB CABINET (SEMI -RECESSED) LKR LOCKER PVMT PAVEMENT TYP TYPICAL A4.1 A4.1 EXISTING WALL
<br />CB CATCH BASIN, CHALKBOARD FF FACTORY FINISHED LMS LIQUID MARKING SURFACE PWP PLASTIC WALL PROTECTION
<br />CC CUBICLE CURTAIN & TRACK FFL FINISHED FLOOR LINE LT LIGHT, LEFT UNFIN UNFINISHED 4 = NEW STUD WALL
<br />FHC FIRE HOSE CABINET LV LOUVER QT QUARRY TILE ' ^ `
<br />CEM CEMENT LINO UNLESS NOTED OTHERWISE i NEW CONCRETE MASONRY UNIT
<br />CER CERAMIC FIN FINISH UPT UNGLAZED PORCELAIN TILE <1D
<br />A] INTERIOR ELEVATION
<br />CFB CEMENT FIBER BOARD FLASH FLASHING MACH MACHINE R RISER, RADIUS UR URINAL 7.1 Elevation number denoted in arrow NEW CONCRETE
<br />CG CORNER GUARD FLR FLOOR, FLOORING MAP MUSIC ACOUSTICAL PANEL R&S CLOSET ROD & SHELF USK UTILITY SINK �/ �l C/ Sheet number denoted in box
<br />CI CAST IRON FLUOR FLUORESCENT MATL MATERIAL RAF RESILIENT ATHLETIC FLOORING i NEW BRICK
<br />CIP CAST -IN -PLACE CONCRETE FOC FACE OF CONCRETE MAX MAXIMUM RB RUBBER BASE VB VAPOR BARRIER
<br />CJ CONTROL JOINT FOF FACE OF FINISH MB MARKING BOARD RCP REFLECTED CEILING PLAN VCT VINYL COMPOSITION TILE ROOM NAME
<br />CLG CEILING FOM FACE OF MASONRY MBR MEMBER RD ROOF DRAIN VENT VENTILATE 101 ROOM IDENTIFICATION
<br />CLKG CAULKING FOS FACE OF STUDS MC MEDICINE CABINET RDO ROOF DRAIN, OVERFLOW VER VERIFY
<br />CLO CLOSET FOSH FACE OF SHEATHING MCSP MINERAL COMPOSITE SCULPTURAL PANEL REBAR REINFORCING BAR VERT VERTICAL Q CODED NOTE ELEVATION INDICATIONS
<br />CLR CLEAR, COLOR FP FIREPROOF MDF MEDIUM DENSITY FIBERBOARD RECD RECEIVED VEST VESTIBULE CONCRETE OR PLASTER
<br />CMU CONCRETE MASONRY UNIT FIR FIRE RESISTANT MECH MECHANICAL REF REFERENCE VOL VOLUME 1
<br />CNR CORNER FRMG FRAMING MED MEDIUM REFL REFLECTED AIA WALL TYPE __ -
<br />VRB VENTILATING RUBBER BASE BRICK
<br />CNTR COUNTER FRP FIBER REINFORCED PLASTIC MEMB MEMBRANE REFR REFRIGERATOR VTR VENT THROUGH ROOF
<br />CO CLEANOUT FRTW FIRE RETARDANT TREATED WOOD MEZZ MEZZANINE REINF REINFORCE(D)(ING) VWC VINYL WALL COVERING - - - - - - - - - - - DASHED LINE
<br />COL COLUMN
<br />FS FLOOR SINK MFR MANUFACTURER REQD REQUIRED Used to denote items hidden, overhead, PRECAST CONCRETE LINTELS
<br />COMBO COMBINATION TPD, SNR, & SCD FSS FOLDING SHOWER SEAT MH MANHOLE, MOP HOLDER RESIL RESILIENT W WEST, WIDE, WIDTH not in contract (NIC), or to be removed -r -
<br />COMP COMPOSITION, COMPOSITE FT FOOT, FEET MIN MINIMUM RF ROOF W/ WITH METAL WALL PANELS
<br />CONC CONCRETE FTG FOOTING MIR MIRROR RFT RESILIENT FLOORING TILE W/D WASHER/DRYER BREAK LINE
<br />CONN CONNECTION FURR FURRING MIR-S MIRROR W/ SHELF RH ROBE HOOK W/O WITHOUT Material to continue
<br />CONST CONSTRUCTION FLIT FUTURE MISC MISCELLANEOUS RM ROOM WC WATER CLOSET
<br />CONT CONTINUOUS FWC FABRIC WALL COVERING MO MASONRY OPENING RO ROUGH OPENING WD WOOD - CENTER LINE, GRID LINE
<br />CONTR CONTRACTOR MT(D) MOUNTED) RSD RECESSED SOAP DISPENSER WDW WINDOW - -
<br />COORD COORDINATE MTL METAL RSS RUBBER STAIR STRINGER PROPERTY LINE
<br />WH WOOD FIBER ACOUSTICAL PANEL
<br />CORR CORRIDOR MUL MULLION
<br />RSTR RUBBER STAIR TREAD /RISER WWALL HUNG _
<br />RT RIGHT, RUBBER TILE - 207,5�
<br />CPT CARPET WP WATERPROOF, WALL PADS � � � EXISTING. CONTOUR, DISTURBED
<br />CRTN CURTAIN RWL RAIN WATER LEADER WPTL WOOD PRESERVATIVE TREATED LUMBER
<br />CT CERAMIC TILE WR WATER REPELLENT 76
<br />CTR CENTER WS WEATHER STRIPPING �\ NEW CONTOUR,
<br />CW CURTAIN WALL WSCT WAINSCOT 2075
<br />EXISTING CONTOUR, UNCHANGED
<br />CWP COMPOSITE WALL PANEL WT WEIGHT
<br />WTR WATER �16.2 NEW FINISH GRADE
<br />WWF WELDED WIRE FABRIC
<br />12.5 EXISTING GRADE
<br />TF 12.4 TOP OF FOOTINGj�
<br />TW 17.33 TOP OF WALL
<br />TC 12.42 TOP OFCURB
<br />�TP 11.92 TOP OF PAVEMENT
<br />v
<br />z
<br />N
<br />O
<br />N
<br />6135 REGISTERED
<br />ARCHITECT
<br />MICHAEL R. O'MMAA EY (/
<br />STATE OF WASHINGTON 1
<br />W
<br />ry
<br />W
<br />W
<br />ry
<br />z
<br />W
<br />_J
<br />U
<br />0
<br />LU
<br />z
<br />0
<br />U00
<br />0
<br />N
<br />Q
<br />w
<br />a
<br />w
<br />Uj
<br />U
<br />Ltj
<br />w
<br />W
<br />LL
<br />Q
<br />O
<br />m
<br />0
<br />O
<br />U
<br />a-
<br />�/
<br />ce
<br />M
<br />r
<br />NAC
<br />ARCHITECTURE
<br />nacarchitecture.com
<br />1203 WEST RIVERSIDE AVENUE
<br />SPOKANE WA 99201
<br />P:509.838.8240
<br />NAC NO 111-19089
<br />DRAWN DMP
<br />CHECKED JMK
<br />DATE 3-12-2021
<br />COVER SHEET
<br />CD
<br />GO*01
<br />
|