My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
7 ELEVEN
>
Plans
>
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 11:20:51 AM
Creation date
10/24/2022 10:23:53 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
7 ELEVEN
Permit
B2008-029
Year
2020
Notes
CREATE RETAIL SPACES IN THE FORMER CONVENIENCE STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF DECK <br />METAL TOP TRACK <br />l <br />A7. <br />I I <br />I I <br />SCHEDULED CEILING <br />I I <br />I I <br />I I <br />-METAL STUD BRACING <br />IS REQUIRED FOR STUDS <br />AT 15'-0" HEIGHT <br />METAL STUD FRAMING <br />PER WALL TAG BELOW <br />SUBSTRATE PER PLAN <br />I I <br />MTL STUD FRAMING <br />I <br />I I <br />I I <br />SOUND BAT'T INSULATION <br />I <br />RESTROCOM ONLY <br />I i <br />I I <br />5 <br />I I <br />ATO <br />II I <br />— METAL STUD TRACK <br />ATTACHED W/POWER, <br />®I <br />AC>'TUATED FASTENERS <br />try 24" O.C. MAX. <br />T P OF 0 <br />A 5/8" DRYWALL ON A.6 5/8" DRYWALL ON <br />3-5/8" MTL. STUDS 6" MTL. STUDS <br />SPACING: 24" O.C. SPACING: 24" O.C. <br />STUD GAUGE: 20 GA. STUD GAUGE: 20 GA. <br />WALL TYPES, <br />(D <br />a� <br />1 -1-0 <br />NOTE: REFERENCE A2.2 FOR WALL <br />FINISH AND SUBSTRATE TYPES. <br />I i <br />I I <br />',I I <br />METAL STUD FRAMING <br />/'— PER WALL TAG BELOW <br />SUBSTRATE PER PLAN <br />'I I <br />II I <br />EXTERIOR MTL STUD FRAMING <br />WALL <br />I I <br />jI I <br />SOUND BATT INSULATION <br />�I @ RESTROOM ONLY <br />III � <br />I I <br />I I 5 <br />' I I <br />AT O <br />;I I <br />I I <br />METAL STUD TRACK <br />ATTACHED W/ POWER <br />'I <br />ACTUATED FASTENERS <br />24" O.C. MAX. <br />TOP OF CONC <br />B 5/8" DRYWALL ON <br />3-5/8" MTL. STUDS <br />SPACING: 24" O.C. <br />STUD GAUGE: 20 GA. <br />TOP OF CONC <br />COOLER/ FREEZER WALL <br />AGAINST WALL <br />PREFABRICATED <br />COOLER WALL <br />SUBSTRATE PER PLAN <br />ROOF DECK <br />TOP OF CONC <br />COOLER/ FREEZER WALL <br />WALL TYPES ARE SHOWN AS METAL STUDS. <br />- GC TO VERIFY WITH 7 ELEVEN CM IF <br />WOOD OR METAL SHOULD BE USED. <br />NOTESGENERAL <br />1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF <br />NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION <br />PROJECT MANAGER. <br />2. GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING DIMENSIONS, AND SITE GRADES <br />PRIOR TO START OF WORK. <br />3. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO <br />DE FURNISHED BY OWNER OR OTHERS, WITH THE MANUFACTURER OR SUPPLIER <br />BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. <br />4. ALL EXTERIOR WALL DIMENSIONS ON THE PLANS UNLESS OTHERWISE NOTED ARE <br />TO OUTSIDE FACE OF EXTERIOR WALL FINISH. <br />5. 2" AIR SPACE BETWEEN COOLER WALL AND BUILDING WALL, OR ANY EQUIPMENT <br />ADJACENT TO COOLER. WALK-IN COOLER SUPPLIED BY 7-ELEVEN, INC, INSTALLATION <br />TO BE DETERMINED BY CONSTRUCTION PROJECT MANAGER. <br />6. CONTRACTOR TO PROVIDE AND INSTALL WALL BACKING FOR WALL HUNG FIXTURES <br />AND TOILET ACCESSORIES. <br />7. ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED, MOISTURE <br />RESISTANT WOOD. <br />8. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: 5.0 L.B.F. FOR INTERIOR <br />DOORS. <br />9. ALL DOORS SHALL BE KEYLESS IN DIRECTION OF EGRESS. <br />10. FIRE EXTINGUISHER: #10 CLASS ADC WITH UL RATING 4A-6OBC, SURFACE MOUNTED <br />ON WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. <br />(COSMIC 1 OE) OR APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL <br />CODES. <br />11. CONTRACTOR TO INSTALL COAT HOOKS FOR EMPLOYEES. REFERENCE SHEET EF1 <br />ITEM 220. INSTALL 2 IN OFFICE AND 3 IN BACKROOM, LOCATION TO BE DETERMINED BY <br />CONSTRUCTION PROJECT MANAGER. SEE DOOR HARDWARE SCHEDULES. <br />12. APPLY 3M SUN CONTROL WINDOW FILMS c@ ALL SOUTH, EAST, AND WEST FACING <br />GLASS (3M-1). NOTE NO FILM SHOULD BE APPLIED TO THE STOREFRONT DOORS. <br />(REFERENCE SHEET A6.1 FOR MATERIALS SCHEDULE). <br />13. G.C. TO FURNISH AND INSTALL RIS BACKBOARD AT ISP DESK. REFERENCE MATERIALS <br />SCHEDULE ON SHEETA6.1. <br />14. NEW CONCRETE SLAB. <br />M <br />° 79'-10" 1 PRE -FABRICATED COOLER WALLS, CEILING, FLOOR, DOORS AND RACKS. MAINTAIN 2" AIR <br />EXISTING OVERALL DIMENSION V.I.F. SPACE BETWEEN COOLER AND ADJACENT WALLS PER MANUFACTURES SPECIFICATIONS. <br />9'-10 1/2" 4 1i4" 2" MIN. 37'-11 1/2"2" MIN. SLR.F CONTRACTOR TO FIELD VERIFY DIMENSIONS WITH PROJECT MANAGER. <br />SLR. <br />2 MOP SINK- REFERENCE PLUMBING. <br />3 PROVIDE SPACE FOR RECESSED BOX IN WALL FOR CO2 LINES AND PVC CONDUIT FOR <br />\ I <br />- POST MIX AND SLURPEE MACHINES. <br />\ -- — - -- — 1 4 NEW SURFACE MOUNTED ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS FOR <br />r I FURTHER INFORMATION. <br />I <br />\ 5 EXISTING EXTERIOR WALL TO REMAIN. PREPARE EXTERIOR WALL FOR NEW WALL <br />FINISHES. REFER TO MATERIALS SCHEDULE FOR FURTHER INFORMATION. <br />OFFICE 1 6 NEW INFILL WALL AT EXISTING ROUGH OPENING TO MATCH ADJACENT WALL <br />DEMISING LINE <br />CONST"RUCTION AND FINISH. <br />' I I <br />o. <br />-- - - ��----- - _ ---— - - — 7 NEW STOREFRONT DOORS. REFER TO EXTERIOR ELEVATIONS AND DOOR HARDWARE <br />\ I SCHEDULE FOR FURTHER INFORMATION. <br />� I � 6 <br />/ <br />CJI 11 X \ C C 8 EXISTING STOREFRONT TO REMAIN. REFER TO EXTERIOR ELEVATIONS FOR FURTHER <br />COOLER INFORMATION. <br />VAULT - ®— 9 NEW STOREFRONT AND GLAZING TO MATCH EXISTING STOREFRONT. <br />I- <br />I A 1 110 (I I'� ��� - <br />I I 1 <br />10 INFlLL EXISTING ROUGH OPENING. CONSTRUCTION TO MATCH EXISTING ADJACENT <br />10 \ A DD b I ( CONSTRUCTION. <br />\ ° A - -i 4 105 </� <br />I <br />2 <br />A3.0 <br />\\ <br />9 <br />LINE OF EXISTING <br />OVERHANG ABOVE <br />( FLOOR PLAN <br />3 3/16" = 1 0" <br />To <br />a <br />z <br />0 <br />z <br />LU <br />('0< <br />x <br />W <br />0 <br />z <br />8 �` 1 8 <br />I. <br />LINE OF EXISTING <br />OVERHANG ABOVE - <br />Wi <br />19'-6 1 /2" <br />IN <br />GC TO SISTER NEW 3/4" x EXISTING — <br />JOIST DEPTH LVLs AND INSTALL 2x <br />CROSS BRACING TO SUPPORT NEW <br />50 GALLON WATER HEATER <br />- REFER TO PLUMBING DRAWINGS <br />SALES FOR FURTHER INFORMATION <br />10� r--I <br />I <br />I <br />-- - -- — — J <br />-- -- I 10DiB <br />-- <br />8 5 8 I 7 <br />I <br />I <br />61'-811 <br />EXISTING OVERALL DIMENSION V.I.F. <br />1 <br />A3.0 <br />18 <br />I 7 1 /4" — — — _j 11'-5" <br />i 3 <br />Wti <br />Emig <br />C <br />0a <br />I <br />0 <br />z <br />W <br />9 <br />A7.1 <br />NOTE: <br />ALL DIMENSIONS ARE TO FACE OF DRY WALL <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 6051:5 <br />Phone: 312.756.7770 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, Ml4 331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />REVISIONS <br />NO, I DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />CONSULTANT <br />SEAL <br />Q-Qtl <br />RE <br />x <br />FA1 <br />on <br />CUSTOMER <br />.11 a ; u� .: mal <br />PROJECT DESCRIPTION <br />STORE # <br />SHEET MANAGEMENT <br />PROJECT NO.: 41664 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: FS/OA <br />REVIEWED BY: JK/10 <br />THIS DOCUMENT ISAND SHALL REMAIN THE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF7HIS DOCUMENT WITHOUT THE EXPRESSE <br />WRITTEN PERMISSION OFSEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />°NOF PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT8YSEVAN DESIGN SOLUTIONS, P.C. 2020 <br />SHEET NUMBER <br />A2.0 <br />0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.