Laserfiche WebLink
ROOF DECK <br />METAL TOP TRACK <br />l <br />A7. <br />I I <br />I I <br />SCHEDULED CEILING <br />I I <br />I I <br />I I <br />-METAL STUD BRACING <br />IS REQUIRED FOR STUDS <br />AT 15'-0" HEIGHT <br />METAL STUD FRAMING <br />PER WALL TAG BELOW <br />SUBSTRATE PER PLAN <br />I I <br />MTL STUD FRAMING <br />I <br />I I <br />I I <br />SOUND BAT'T INSULATION <br />I <br />RESTROCOM ONLY <br />I i <br />I I <br />5 <br />I I <br />ATO <br />II I <br />— METAL STUD TRACK <br />ATTACHED W/POWER, <br />®I <br />AC>'TUATED FASTENERS <br />try 24" O.C. MAX. <br />T P OF 0 <br />A 5/8" DRYWALL ON A.6 5/8" DRYWALL ON <br />3-5/8" MTL. STUDS 6" MTL. STUDS <br />SPACING: 24" O.C. SPACING: 24" O.C. <br />STUD GAUGE: 20 GA. STUD GAUGE: 20 GA. <br />WALL TYPES, <br />(D <br />a� <br />1 -1-0 <br />NOTE: REFERENCE A2.2 FOR WALL <br />FINISH AND SUBSTRATE TYPES. <br />I i <br />I I <br />',I I <br />METAL STUD FRAMING <br />/'— PER WALL TAG BELOW <br />SUBSTRATE PER PLAN <br />'I I <br />II I <br />EXTERIOR MTL STUD FRAMING <br />WALL <br />I I <br />jI I <br />SOUND BATT INSULATION <br />�I @ RESTROOM ONLY <br />III � <br />I I <br />I I 5 <br />' I I <br />AT O <br />;I I <br />I I <br />METAL STUD TRACK <br />ATTACHED W/ POWER <br />'I <br />ACTUATED FASTENERS <br />24" O.C. MAX. <br />TOP OF CONC <br />B 5/8" DRYWALL ON <br />3-5/8" MTL. STUDS <br />SPACING: 24" O.C. <br />STUD GAUGE: 20 GA. <br />TOP OF CONC <br />COOLER/ FREEZER WALL <br />AGAINST WALL <br />PREFABRICATED <br />COOLER WALL <br />SUBSTRATE PER PLAN <br />ROOF DECK <br />TOP OF CONC <br />COOLER/ FREEZER WALL <br />WALL TYPES ARE SHOWN AS METAL STUDS. <br />- GC TO VERIFY WITH 7 ELEVEN CM IF <br />WOOD OR METAL SHOULD BE USED. <br />NOTESGENERAL <br />1. CONTRACTORS SHALL NOT SCALE THESE DRAWINGS. IN THE EVENT OF OMISSION OF <br />NECESSARY DIMENSIONS THE CONTRACTORS SHALL NOTIFY THE CONSTRUCTION <br />PROJECT MANAGER. <br />2. GENERAL CONTRACTOR SHALL VERIFY ALL BUILDING DIMENSIONS, AND SITE GRADES <br />PRIOR TO START OF WORK. <br />3. VERIFY SIZE, LOCATION, AND CHARACTERISTICS, OF ALL WORK AND EQUIPMENT TO <br />DE FURNISHED BY OWNER OR OTHERS, WITH THE MANUFACTURER OR SUPPLIER <br />BEFORE ANY CONSTRUCTION PERTAINING TO SAME IS BEGUN. <br />4. ALL EXTERIOR WALL DIMENSIONS ON THE PLANS UNLESS OTHERWISE NOTED ARE <br />TO OUTSIDE FACE OF EXTERIOR WALL FINISH. <br />5. 2" AIR SPACE BETWEEN COOLER WALL AND BUILDING WALL, OR ANY EQUIPMENT <br />ADJACENT TO COOLER. WALK-IN COOLER SUPPLIED BY 7-ELEVEN, INC, INSTALLATION <br />TO BE DETERMINED BY CONSTRUCTION PROJECT MANAGER. <br />6. CONTRACTOR TO PROVIDE AND INSTALL WALL BACKING FOR WALL HUNG FIXTURES <br />AND TOILET ACCESSORIES. <br />7. ALL WOOD IN CONTACT WITH CONCRETE MUST BE PRESSURE TREATED, MOISTURE <br />RESISTANT WOOD. <br />8. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED: 5.0 L.B.F. FOR INTERIOR <br />DOORS. <br />9. ALL DOORS SHALL BE KEYLESS IN DIRECTION OF EGRESS. <br />10. FIRE EXTINGUISHER: #10 CLASS ADC WITH UL RATING 4A-6OBC, SURFACE MOUNTED <br />ON WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. <br />(COSMIC 1 OE) OR APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL <br />CODES. <br />11. CONTRACTOR TO INSTALL COAT HOOKS FOR EMPLOYEES. REFERENCE SHEET EF1 <br />ITEM 220. INSTALL 2 IN OFFICE AND 3 IN BACKROOM, LOCATION TO BE DETERMINED BY <br />CONSTRUCTION PROJECT MANAGER. SEE DOOR HARDWARE SCHEDULES. <br />12. APPLY 3M SUN CONTROL WINDOW FILMS c@ ALL SOUTH, EAST, AND WEST FACING <br />GLASS (3M-1). NOTE NO FILM SHOULD BE APPLIED TO THE STOREFRONT DOORS. <br />(REFERENCE SHEET A6.1 FOR MATERIALS SCHEDULE). <br />13. G.C. TO FURNISH AND INSTALL RIS BACKBOARD AT ISP DESK. REFERENCE MATERIALS <br />SCHEDULE ON SHEETA6.1. <br />14. NEW CONCRETE SLAB. <br />M <br />° 79'-10" 1 PRE -FABRICATED COOLER WALLS, CEILING, FLOOR, DOORS AND RACKS. MAINTAIN 2" AIR <br />EXISTING OVERALL DIMENSION V.I.F. SPACE BETWEEN COOLER AND ADJACENT WALLS PER MANUFACTURES SPECIFICATIONS. <br />9'-10 1/2" 4 1i4" 2" MIN. 37'-11 1/2"2" MIN. SLR.F CONTRACTOR TO FIELD VERIFY DIMENSIONS WITH PROJECT MANAGER. <br />SLR. <br />2 MOP SINK- REFERENCE PLUMBING. <br />3 PROVIDE SPACE FOR RECESSED BOX IN WALL FOR CO2 LINES AND PVC CONDUIT FOR <br />\ I <br />- POST MIX AND SLURPEE MACHINES. <br />\ -- — - -- — 1 4 NEW SURFACE MOUNTED ELECTRICAL PANELS. REFER TO ELECTRICAL DRAWINGS FOR <br />r I FURTHER INFORMATION. <br />I <br />\ 5 EXISTING EXTERIOR WALL TO REMAIN. PREPARE EXTERIOR WALL FOR NEW WALL <br />FINISHES. REFER TO MATERIALS SCHEDULE FOR FURTHER INFORMATION. <br />OFFICE 1 6 NEW INFILL WALL AT EXISTING ROUGH OPENING TO MATCH ADJACENT WALL <br />DEMISING LINE <br />CONST"RUCTION AND FINISH. <br />' I I <br />o. <br />-- - - ��----- - _ ---— - - — 7 NEW STOREFRONT DOORS. REFER TO EXTERIOR ELEVATIONS AND DOOR HARDWARE <br />\ I SCHEDULE FOR FURTHER INFORMATION. <br />� I � 6 <br />/ <br />CJI 11 X \ C C 8 EXISTING STOREFRONT TO REMAIN. REFER TO EXTERIOR ELEVATIONS FOR FURTHER <br />COOLER INFORMATION. <br />VAULT - ®— 9 NEW STOREFRONT AND GLAZING TO MATCH EXISTING STOREFRONT. <br />I- <br />I A 1 110 (I I'� ��� - <br />I I 1 <br />10 INFlLL EXISTING ROUGH OPENING. CONSTRUCTION TO MATCH EXISTING ADJACENT <br />10 \ A DD b I ( CONSTRUCTION. <br />\ ° A - -i 4 105 </� <br />I <br />2 <br />A3.0 <br />\\ <br />9 <br />LINE OF EXISTING <br />OVERHANG ABOVE <br />( FLOOR PLAN <br />3 3/16" = 1 0" <br />To <br />a <br />z <br />0 <br />z <br />LU <br />('0< <br />x <br />W <br />0 <br />z <br />8 �­` 1 8 <br />I. <br />LINE OF EXISTING <br />OVERHANG ABOVE - <br />Wi <br />19'-6 1 /2" <br />IN <br />GC TO SISTER NEW 3/4" x EXISTING — <br />JOIST DEPTH LVLs AND INSTALL 2x <br />CROSS BRACING TO SUPPORT NEW <br />50 GALLON WATER HEATER <br />- REFER TO PLUMBING DRAWINGS <br />SALES FOR FURTHER INFORMATION <br />10� r--I <br />I <br />I <br />-- - -- — — J <br />-- -- I 10DiB <br />-- <br />8 5 8 I 7 <br />I <br />I <br />61'-811 <br />EXISTING OVERALL DIMENSION V.I.F. <br />1 <br />A3.0 <br />18 <br />I 7 1 /4" — — — _j 11'-5" <br />i 3 <br />Wti <br />Emig <br />C <br />0a <br />I <br />0 <br />z <br />W <br />9 <br />A7.1 <br />NOTE: <br />ALL DIMENSIONS ARE TO FACE OF DRY WALL <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 6051:5 <br />Phone: 312.756.7770 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, Ml4 331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />REVISIONS <br />NO, I DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />CONSULTANT <br />SEAL <br />Q-Qtl <br />RE <br />x <br />FA1 <br />on <br />CUSTOMER <br />.11 a ; u� .: mal <br />PROJECT DESCRIPTION <br />STORE # <br />SHEET MANAGEMENT <br />PROJECT NO.: 41664 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: FS/OA <br />REVIEWED BY: JK/10 <br />THIS DOCUMENT ISAND SHALL REMAIN THE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF7HIS DOCUMENT WITHOUT THE EXPRESSE <br />WRITTEN PERMISSION OFSEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />°NOF PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT8YSEVAN DESIGN SOLUTIONS, P.C. 2020 <br />SHEET NUMBER <br />A2.0 <br />0 <br />