Laserfiche WebLink
TILE START POINT <br />s <br />N <br />Da <br />3 <br />\ 15 <br />A7.0 DOOR <br />THRESHOLD <br />G.C. TO INSTALL CUT <br />FLOOR TILE ALONG <br />ENTRANCE WALL. <br />11015 1 <br />-4 <br />33% <br />OFFSET <br />15 DOOR <br />A7.0 THRESHOLD <br />NO <br />DOOR 15 <br />THRESHOLD A7.0 <br />1*1 <br />KEY NOTES <br />1, NOT USED. ' Z <br />2. TILE TO BE INSTALLED UP TO EDGE OF MOP SINK. <br />3. THRESHOLD TO BE SET IN FULL BED OF MASTIC. <br />4. FLOOR SINK/DRAIN PER PLAN, REFERENCE DETAILS ON SHEET A7.0 & PLUMBING DRAWINGS <br />FOR LOCATION. <br />5. CONTRACTOR TO CUT TILE STRAIGHT AND TRUE, NOT LESS THAN 1/2 A TILE. <br />6. NOT USED. <br />7. NOT USED. <br />6. NOT USED. <br />9. NOT USED. <br />10. 3" (33%) OFFSET RUNNING BOND PORCELAIN TILE FLOOR PER MATERIAL SCHEDULE ON A6.1. <br />24" EDGE OF TILE TO RUN PARALLEL WITH ENTRY STOREFRONT, BEGIN FULL SIZE TILE AT <br />EDGE OF ENTRY THRESHOLD. <br />11. IF TILE IS USE - CONTRACTOR SHALL PREP THE EXISTING SUBFLOOR AND INSTALL <br />SCHLUTER - DITRA (OR EQUAL) POLYETHYLENE (CLEAVAGE) MEMBRANE PER <br />MANUFACTURERS INSTALLATION INSTRUCTIONS. <br />OFFICE <br />1®3 <br />T-3 <br />(FLOOR TILE) <br />NOTE. <br />0 <br />GENERAL NOTES <br />1. ALL INTERIOR FINISHES TO BE CLASS 2 OR SETTER. <br />2. CONTRACTOR TO FLOAT AND SCRAPE FLOOR TO BE LEVEL ARID PREPARE FOR NEW <br />SCHEDULED FINISH, AS REQUIRED. <br />3. CONTRACTOR TO RESERVE SPECIFIED FLOORING ARID SASE UPON BEING AWARDED THE <br />BID TO ENSURE AVAILABILITY AND -TIMELY INSTALLATION. SUBSTITUTIONS ARE NOT <br />PERMITTED. <br />4. FLOORS IN WET AREAS TO SLOPE TO DRAINS 1/6" PER FOOT, TYP. <br />5. PROVIDE A BEAD OF CAULK AT INTERIOR CONDITIONS PER OWNER DIRECTION AND <br />PROJECT NEEDS, CAULK IS TO MATCH COLOR OF ADJACENT MATERIAL. <br />6. REFERENCE INTERIOR ELEVATIONS FOR WALL FINISHES. <br />7. REFERENCE SHEET A6.1 FOR BASE TYPES. <br />6. FIDE EXTINGUISHER: #10 CLASS ABC WITH UL RATING 4A-60BC. SURFACE MOUNTED ON <br />WALL WITH MANUFACTURERS ALL STEEL WALL BRACKET. JL INDUSTRIES INC. (COSMIC 1 OE) <br />OR APPROVED EQUAL WITH INSPECTION TAG AS REQUIRED BY LOCAL CODES. <br />9. CONTRACTOR TO INSTALL 7-ELEVEN PROVIDED COAT HOOKS FOR EMPLOYEES. REFERENCE <br />SHEET EFI ITEM 220. INSTALL 2 IN OFFICE AND 3 IN BACKROOM. LOCATION TO BE <br />DETERMINED BY CONSTRUCTION PROJECT MANAGER. SEE DOOR HARDWARE SCHEDULES. <br />I 10. APPLY 3M SUN CONTROL WINDOW FILMS @ ALL SOUTH, EAST, AND WEST FACING GLASS <br />(3M-1). NOTE NO FILM SHOULD BE APPLIED TO THE STOREFRONT DOORS. (REFERENCE <br />SHEET A6.1 FOR MATERIALS SCHEDULE). <br />11. G.C. TO FURNISH AND INSTALL RIS BACKBOARD AT ISP DESK. REFERENCE MATERIALS <br />SCHEDULE ON SHEET A6.1. <br />12. PROTECT SURROUNDING AREAS AND SURFACES FROM DUST, CONTACT WITH OVERSPRAY <br />FROM DENSIFIER, PROTECTIVE SURFACE TREATMENT, & JOINT FILLER. CLEAN SURFACES <br />FROM DUST, DEBRIS, OIL, GREASE, CURING AGENTS, AND OTHER SURFACE CONTAMINANTS <br />THAT MAY ADVERSELY AFFECT INSTALLATION OF POLISHED CONCRETE. <br />13.. REFERENCE. SPECIFICATION SECTIONS 033000 CAST -IN -PLACE CONCRETE AND 033536 <br />POLISHED CONCRETE FLOOR FINISH DATED 02-26-2016, PROVIDED BY 7-ELEVEN, FOR ALL <br />NEW INTERIOR CONCRETE FLOORS. <br />Corporate Office: <br />3025 Highland Parkway, Suite E50 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 dills Tech Drive <br />Farmington Hills, MI4 331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY I <br />0 REVISIONS <br />NO. DATE DESCRIPTION <br />1 11/04/2) OWNER/PEER REVIEW COMMENTS <br />I CONSULTANT II <br />SEAL <br />7862 <br />aka <br />IVT <br />H I i E <br />R DE 1P is <br />I CUSTOMER II <br />I PROJECT DESCRIPTION I <br />I PROJECT LOCATION <br />607 SE EVERETT MALL <br />WAY <br />En <br />SHEET TITLE <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: RS/0A <br />REVIEWED BY: JI</JD <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT WITHOUT THE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />(NOT PUBLISHED: AIL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN DESIGN SOLUTIONS, P.C. 2020 <br />SHEET NUMBER <br />