Laserfiche WebLink
PORCELAIN TILE <br />THIN SET MORTAR <br />1 <br />COVE BASE - (B-3) <br />(SCHLUTER: - HKA) <br />TYPICAL ALL TOILET <br />ROOM FLOOR EDGES <br />FLOOR FINISH <br />ww ,� A I- . <br />• <br />PREMANUFACTURED <br />COOLER VAULT; UNDER <br />SEPARATE PERMIT <br />WALL TILE (T-5)(REF A6.1 - <br />MATERIAL SCHEDULE) <br />ADHERE PER <br />MANUFACTURERS <br />RECOMMENDATIONS <br />1/2" MOISTURE RESISTANT - <br />GREEN GYP BD ADHERED <br />TO COOLER VAULT. STAPLE <br />PERIMETER AT 12" O.C. <br />SCHLUTER SCHIENE (TE-1)- <br />SEALANT <br />ALUMINUM FRAME GLASS DOOR — <br />ASSEMBLY, BY OTHER. <br />DOOR SEAL, BY OTHER. <br />DOOR FRAME, BY OTHER. <br />LIGHT FIXTURE AT JAMB, BY OTHER <br />ID• <br />REQUIRED GAP PER <br />MANUFACTURER <br />EXTEND WALL FINISH <br />AS SCHEDULED V-0" <br />MIN. TYP. <br />COOLER WALL PER <br />MANUFACTURER <br />ADJACENT WALL <br />PORCELAIN TILE - <br />THIN SET MORTAR <br />CONCRETE SLAB - <br />• <br />ALUMINUM FRAME GLASS DOOR <br />ASSEMBLY, BY OTHER. <br />SEALANT <br />SCHLUTER SCHIENE (TE-1) <br />WALL TILE (T-5, REF A6.1 <br />MATERIAL SCHEDULE) <br />ADHERE PER <br />MANUFACTURERS <br />RECOMMENDATIONS <br />1/2" MOISTURE RESISTANT <br />GREEN GYP BD ADHERED <br />TO COOLER VAULT. STAPLE <br />PERIMETER AT 12" O.C. <br />SCHLUTER DILEX AHKA <br />(B-2) <br />TRANSITION STRIP <br />(SCHLUTER: <br />REMO-RAMP) <br />Z" MAXIMUM TOTAL <br />RISE AT DOORS. <br />NON -DOOR AREAS 1:20 <br />SLOPE <br />12 <br />____] 1 <br />PREMANUFACTURED <br />COOLER VAULT; UNDER <br />SEPARATE PERMIT <br />TILE/COOLER MERCHANDISED %..JFX FINISH <br />13 TRANSITION BASE DETAIL <br />6" = 1'-0.. <br />SLOPE 118" PER FT <br />FLOOR FINISH <br />PER PLAN <br />-SEALANT - <br />THIN SET BOND COAT OR PRIMER <br />PER MANUFACTURER'S <br />RECOMMENDATIONS <br />- --- WATERPROOFING " -- <br />MEMBRANE <br />SLOPE 1/8" PER FT <br />f <br />SEALANT <br />S.S. SCREW @ 2' <br />_ O.C. AND COUNTER <br />> 3" SUNK EXISTING WOOD SHEATHING & <br />16 GA S.S. 2"x3" FLOOR JOISTS TO REMAIN <br />CONT. ANGLE W/ - GC TO VERIFY EXISTING <br />SEALANT, TYP. 1 CONDITION IN FIELD <br />FLOOR SINK DETAIL (FLUSH) <br />DioDETAIL -CLOSURE STRIP I�C,U COOLER FOR TILE FLOORING <br />14 <br />NOTE: <br />METAL STUD DETAIL SHOWN FOR REFERENCE ONLY <br />- GC TO REFER TO PLUMBING DRAWINGS FOR MANUFACTURER AND MODEL NUMBER OF <br />FLOOR SINK AND INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS <br />FINISH AS <br />SCHEDULED I I I I I I <br />CONT. 20 GA. METAL STUD <br />FLOOR TRACK- IN ACCORDANCE <br />WITH (ESR-2269 REPORT) <br />PROVIDE POWER ACTUATED <br />FASTENERS USE HILTI X-U 32" <br />KNUDLED SHANK FASTENER <br />SCREW@ 48" O.C. (0.157" <br />DIAMETER, 1 4" EMBEDMENT) <br />PENETRATIONS IN SLAB SHALL <br />NOT EXCEED 3 OF <br />SLAB THICKNESS. <br />EXISTING WOOD SHEATHING AND <br />FLOOR JOISTS TO REMAIN. <br />NEW DOOR <br />THRESHOLD <br />TRANSITION STRIP - TE-1 <br />(SCHLUTER: E80-EB, <br />SCHIENE EDGE) <br />PORCELAIN TILE <br />THIN SET MORTAR <br />CONCRETE SLAB <br />TRANSITION DETAIL: <br />15)FLOOR TILE TO THRESHOLD <br />6 = 1 -0 <br />PREMANUFACTURED - <br />COOLER VAULT; UNDER <br />SEPARATE PERMIT <br />WALL TILE (T-5)(REF A6.1 <br />MATERIAL SCHEDULE) <br />ADHERE PER <br />MANUFACTURERS <br />RECOMMENDATIONS <br />1/2" MOIS <br />GREEN G <br />TO COOL <br />PERIMET <br />SCHLUTE <br />SEALANT <br />DOOR FR <br />COOLER <br />DOOR SE <br />WATERPROOFING - <br />MEMBRANE, REFER TO <br />PLAN DETAIL 1/A5.4 <br />SLOPE 1/8" PER FT <br />INTERIOR NON -LOAD BEARING PARTITION HEADER SCHEDULE <br />HEADER <br />LENGTH <br />HEADER <br />MEMBERS <br />MINIMUM EFFECTIVE <br />PROPERTIES PER STUD <br />2' TO 6' <br />2 6" x 18 GAUGE <br />Ix = 2,042 Sx = 0.670 <br />6' TO 8' <br />2 6" x 16 GAUGE <br />Ix = 2.518 Sx = 0.839 <br />8' TO 10' <br />2 6" x 14 GAUGE <br />Ix = 3.094 Sx = 1.031 <br />10' TO 12' <br />2 8" x 18 GAUGE <br />Ix = 4.134 Sx = 1.033 <br />12' TO 14' <br />2 8" x 16 GAUGE <br />Ix = 5.110 Sx = 1.277 <br />14' TO 16' <br />2 8" x 14 GAUGE <br />Ix = 6.303 Sx = 1.576 <br />16' TO 18' <br />2 10" x 14 GAUGE <br />Ix = 12.325 Sx = 2.456 <br />18' TO 26' <br />2 12" x 16 GAUGE <br />I Ix = 15.730 Sx = 2.334 <br />METAL STUD <br />HEADER <br />PC 18 GA TRACK <br />WITH (3) #10 TEK <br />SCREWS EACH SIDE <br />TO HEADER AND (6) <br />#10 TEK SCREWS TO <br />JAMB <br />METAL STUD JAMB <br />AS <br />SCHEDULED <br />FLOOR FINISH PER <br />PLAN <br />SLOPE 118�PER _FT <br />FINISH AS <br />SCHEDULED <br />1/2" GYP BOARD <br />METAL STUD BOX BEAM HEADER 1/2" <br />CONTINUOUS = <br />SEALANT EACH SIDE <br />DOOR FRAME JAMB <br />THIN SET BOND COAT _ <br />ANCHORS, MIN. 3 <br />OR PRIMER PER PER JAMB _ _ e J <br />MANUFACTURER'S <br />tESTING WOOD SHEATHING & -� <br />RECOMMENDATIONS METAL FRAME <br />OR JOISTS TO REMAIN HOLLOW ME AS <br />TO VERIFY EXISTINGNDITION INFIELD SCHEDULED <br />REFERENCE A6.0 <br />FLOOR DRAIN DETAIL <br />8 FOR TILE FLOORING 7 DETAIL - INTERIOR DOOR JAMB / HEAD <br />3 -1-0 3 -1-0 <br />1 NOTE: <br />DETAIL SHOWN FOR REFERENCE ONLY <br />- GC TO REFER TO PLUMBING DRAWINGS FOR MANUFACTURER AND MODEL NUMBER OF <br />FLOOR DRAIN AND INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS <br />BACKER ROD WITH <br />SILICONE CAULK <br />JOINT STOREFRONT <br />CORNER BEAD CONTINUOUS <br />BACKER ROD & <br />1/2" GYP BOARD SEALANT, BOTH <br />FINISH AS SIDES <br />SCHEDULED ( METAL J TRIM TO <br />MATCH <br />STOREFRONT <br />SEALANT <br />FINISH AS <br />SCHEDULED <br />MOISTURE BARRIER <br />EXIST. WALL <br />CONSTRUCTION <br />TO REMAIN <br />19 <br />SEALANT <br />a�laoae <br />3 DETAIL - STOREFRONT SILL KNEE WALL <br />3 = 1'-0" <br />BOX BEAM <br />PC 18 GA TRACK <br />DOUBLE MTL STUD <br />AT JAMBS <br />METAL STUD <br />BOTTOM TRACK <br />TOP TRACK <br />2 STUD HEADERS <br />FINISH AS <br />INDICATED <br />BATT INSULATION <br />BOTTOM TRACK <br />SECTION A <br />41 <br />2" CLR. FROM TOP iv <br />TRACK <br />EXISTING WOOD <br />' <br />OR MTL. DECK <br />CONT. 20 GA. 3 $" OR 6" MTL. STUD___x <br />TOP TRACK WITH 4" SLOTTED <br />LEGS: ATTACH TO LOW CELLS OF <br />I I <br />1/2" GYP BOARD <br />MTL. DECK OR WOOD DECK iv <br />ABOVE @ 48" O.C. WITH #8-18x4" <br />( I <br />ATTACHED TO TO <br />TRACK ONLY <br />HWH SELF TAPPING SCREWS, <br />G.C. TO VERIFY WOOD DECK ; <br />THICKNESS TO INSURE <br />FASTENERS DO NOT <br />I I <br />PENETRATE THE ROOFING <br />MEMBRANE. <br />I I <br />FINISH AS <br />SCHEDULED <br />METAL STUD <br />SPACER BAR NOT MORE THAN <br />12" FROM TOP OF STUD, TO BE <br />INSTALLED PER MANU. SPECS <br />IF <br />EXIST. EIFS <br />' <br />EXTERIOR FINISH <br />n <br />TO REMAIN <br />EXIST. WALL <br />EXIST. GYP <br />E <br />CONSTRUCTION <br />BOARD <br />- <br />TO REMAIN <br />FINISH AS <br />_ <br />I <br />SCHEDULED <br />REFERENCE A2.2 <br />( <br />METAL J TRIM TO <br />�- <br />MATCH <br />STOREFRONT <br />CONTINUOUS <br />BACKER ROD & <br />SEALANT, BOTH <br />SIDES <br />BACKER ROD AND <br />1" <br />SILICONE CAULK <br />LINE OF EIFS <br />JOINT <br />V.I.F. INSET TO <br />MATCH EXISTING <br />ADJACENT <br />STOREFRONT <br />')DETAIL - <br />STOREFRONT JAMB/HEAD <br />3" = 1'-0" <br />D0ETAIL - STUD SLIP JOINT <br />6 <br />3" = 1'-01, <br />1 NOT USED <br />sevan <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI 48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />0 REVISIONS <br />NO. I DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />CONSULTANT <br />m <br />CUSTOMER <br />PROJECT DESCRIPTION <br />STORE <br />41564 <br />SHEET TITLE <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: FS/OA <br />REVIEWED BY: JK/JD <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT WITHOUT THE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN DESIGN SOLUTIONS, P.C. 2020 <br />SHEET NUMBER <br />A7.0 <br />