My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
7 ELEVEN
>
Plans
>
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 11:20:51 AM
Creation date
10/24/2022 10:23:53 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
7 ELEVEN
Permit
B2008-029
Year
2020
Notes
CREATE RETAIL SPACES IN THE FORMER CONVENIENCE STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PORCELAIN TILE <br />THIN SET MORTAR <br />1 <br />COVE BASE - (B-3) <br />(SCHLUTER: - HKA) <br />TYPICAL ALL TOILET <br />ROOM FLOOR EDGES <br />FLOOR FINISH <br />ww ,� A I- . <br />• <br />PREMANUFACTURED <br />COOLER VAULT; UNDER <br />SEPARATE PERMIT <br />WALL TILE (T-5)(REF A6.1 - <br />MATERIAL SCHEDULE) <br />ADHERE PER <br />MANUFACTURERS <br />RECOMMENDATIONS <br />1/2" MOISTURE RESISTANT - <br />GREEN GYP BD ADHERED <br />TO COOLER VAULT. STAPLE <br />PERIMETER AT 12" O.C. <br />SCHLUTER SCHIENE (TE-1)- <br />SEALANT <br />ALUMINUM FRAME GLASS DOOR — <br />ASSEMBLY, BY OTHER. <br />DOOR SEAL, BY OTHER. <br />DOOR FRAME, BY OTHER. <br />LIGHT FIXTURE AT JAMB, BY OTHER <br />ID• <br />REQUIRED GAP PER <br />MANUFACTURER <br />EXTEND WALL FINISH <br />AS SCHEDULED V-0" <br />MIN. TYP. <br />COOLER WALL PER <br />MANUFACTURER <br />ADJACENT WALL <br />PORCELAIN TILE - <br />THIN SET MORTAR <br />CONCRETE SLAB - <br />• <br />ALUMINUM FRAME GLASS DOOR <br />ASSEMBLY, BY OTHER. <br />SEALANT <br />SCHLUTER SCHIENE (TE-1) <br />WALL TILE (T-5, REF A6.1 <br />MATERIAL SCHEDULE) <br />ADHERE PER <br />MANUFACTURERS <br />RECOMMENDATIONS <br />1/2" MOISTURE RESISTANT <br />GREEN GYP BD ADHERED <br />TO COOLER VAULT. STAPLE <br />PERIMETER AT 12" O.C. <br />SCHLUTER DILEX AHKA <br />(B-2) <br />TRANSITION STRIP <br />(SCHLUTER: <br />REMO-RAMP) <br />Z" MAXIMUM TOTAL <br />RISE AT DOORS. <br />NON -DOOR AREAS 1:20 <br />SLOPE <br />12 <br />____] 1 <br />PREMANUFACTURED <br />COOLER VAULT; UNDER <br />SEPARATE PERMIT <br />TILE/COOLER MERCHANDISED %..JFX FINISH <br />13 TRANSITION BASE DETAIL <br />6" = 1'-0.. <br />SLOPE 118" PER FT <br />FLOOR FINISH <br />PER PLAN <br />-SEALANT - <br />THIN SET BOND COAT OR PRIMER <br />PER MANUFACTURER'S <br />RECOMMENDATIONS <br />- --- WATERPROOFING " -- <br />MEMBRANE <br />SLOPE 1/8" PER FT <br />f <br />SEALANT <br />S.S. SCREW @ 2' <br />_ O.C. AND COUNTER <br />> 3" SUNK EXISTING WOOD SHEATHING & <br />16 GA S.S. 2"x3" FLOOR JOISTS TO REMAIN <br />CONT. ANGLE W/ - GC TO VERIFY EXISTING <br />SEALANT, TYP. 1 CONDITION IN FIELD <br />FLOOR SINK DETAIL (FLUSH) <br />DioDETAIL -CLOSURE STRIP I�C,U COOLER FOR TILE FLOORING <br />14 <br />NOTE: <br />METAL STUD DETAIL SHOWN FOR REFERENCE ONLY <br />- GC TO REFER TO PLUMBING DRAWINGS FOR MANUFACTURER AND MODEL NUMBER OF <br />FLOOR SINK AND INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS <br />FINISH AS <br />SCHEDULED I I I I I I <br />CONT. 20 GA. METAL STUD <br />FLOOR TRACK- IN ACCORDANCE <br />WITH (ESR-2269 REPORT) <br />PROVIDE POWER ACTUATED <br />FASTENERS USE HILTI X-U 32" <br />KNUDLED SHANK FASTENER <br />SCREW@ 48" O.C. (0.157" <br />DIAMETER, 1 4" EMBEDMENT) <br />PENETRATIONS IN SLAB SHALL <br />NOT EXCEED 3 OF <br />SLAB THICKNESS. <br />EXISTING WOOD SHEATHING AND <br />FLOOR JOISTS TO REMAIN. <br />NEW DOOR <br />THRESHOLD <br />TRANSITION STRIP - TE-1 <br />(SCHLUTER: E80-EB, <br />SCHIENE EDGE) <br />PORCELAIN TILE <br />THIN SET MORTAR <br />CONCRETE SLAB <br />TRANSITION DETAIL: <br />15)FLOOR TILE TO THRESHOLD <br />6 = 1 -0 <br />PREMANUFACTURED - <br />COOLER VAULT; UNDER <br />SEPARATE PERMIT <br />WALL TILE (T-5)(REF A6.1 <br />MATERIAL SCHEDULE) <br />ADHERE PER <br />MANUFACTURERS <br />RECOMMENDATIONS <br />1/2" MOIS <br />GREEN G <br />TO COOL <br />PERIMET <br />SCHLUTE <br />SEALANT <br />DOOR FR <br />COOLER <br />DOOR SE <br />WATERPROOFING - <br />MEMBRANE, REFER TO <br />PLAN DETAIL 1/A5.4 <br />SLOPE 1/8" PER FT <br />INTERIOR NON -LOAD BEARING PARTITION HEADER SCHEDULE <br />HEADER <br />LENGTH <br />HEADER <br />MEMBERS <br />MINIMUM EFFECTIVE <br />PROPERTIES PER STUD <br />2' TO 6' <br />2 6" x 18 GAUGE <br />Ix = 2,042 Sx = 0.670 <br />6' TO 8' <br />2 6" x 16 GAUGE <br />Ix = 2.518 Sx = 0.839 <br />8' TO 10' <br />2 6" x 14 GAUGE <br />Ix = 3.094 Sx = 1.031 <br />10' TO 12' <br />2 8" x 18 GAUGE <br />Ix = 4.134 Sx = 1.033 <br />12' TO 14' <br />2 8" x 16 GAUGE <br />Ix = 5.110 Sx = 1.277 <br />14' TO 16' <br />2 8" x 14 GAUGE <br />Ix = 6.303 Sx = 1.576 <br />16' TO 18' <br />2 10" x 14 GAUGE <br />Ix = 12.325 Sx = 2.456 <br />18' TO 26' <br />2 12" x 16 GAUGE <br />I Ix = 15.730 Sx = 2.334 <br />METAL STUD <br />HEADER <br />PC 18 GA TRACK <br />WITH (3) #10 TEK <br />SCREWS EACH SIDE <br />TO HEADER AND (6) <br />#10 TEK SCREWS TO <br />JAMB <br />METAL STUD JAMB <br />AS <br />SCHEDULED <br />FLOOR FINISH PER <br />PLAN <br />SLOPE 118�PER _FT <br />FINISH AS <br />SCHEDULED <br />1/2" GYP BOARD <br />METAL STUD BOX BEAM HEADER 1/2" <br />CONTINUOUS = <br />SEALANT EACH SIDE <br />DOOR FRAME JAMB <br />THIN SET BOND COAT _ <br />ANCHORS, MIN. 3 <br />OR PRIMER PER PER JAMB _ _ e J <br />MANUFACTURER'S <br />tESTING WOOD SHEATHING & -� <br />RECOMMENDATIONS METAL FRAME <br />OR JOISTS TO REMAIN HOLLOW ME AS <br />TO VERIFY EXISTINGNDITION INFIELD SCHEDULED <br />REFERENCE A6.0 <br />FLOOR DRAIN DETAIL <br />8 FOR TILE FLOORING 7 DETAIL - INTERIOR DOOR JAMB / HEAD <br />3 -1-0 3 -1-0 <br />1 NOTE: <br />DETAIL SHOWN FOR REFERENCE ONLY <br />- GC TO REFER TO PLUMBING DRAWINGS FOR MANUFACTURER AND MODEL NUMBER OF <br />FLOOR DRAIN AND INSTALL PER MANUFACTURERS INSTALLATION INSTRUCTIONS <br />BACKER ROD WITH <br />SILICONE CAULK <br />JOINT STOREFRONT <br />CORNER BEAD CONTINUOUS <br />BACKER ROD & <br />1/2" GYP BOARD SEALANT, BOTH <br />FINISH AS SIDES <br />SCHEDULED ( METAL J TRIM TO <br />MATCH <br />STOREFRONT <br />SEALANT <br />FINISH AS <br />SCHEDULED <br />MOISTURE BARRIER <br />EXIST. WALL <br />CONSTRUCTION <br />TO REMAIN <br />19 <br />SEALANT <br />a�laoae <br />3 DETAIL - STOREFRONT SILL KNEE WALL <br />3 = 1'-0" <br />BOX BEAM <br />PC 18 GA TRACK <br />DOUBLE MTL STUD <br />AT JAMBS <br />METAL STUD <br />BOTTOM TRACK <br />TOP TRACK <br />2 STUD HEADERS <br />FINISH AS <br />INDICATED <br />BATT INSULATION <br />BOTTOM TRACK <br />SECTION A <br />41 <br />2" CLR. FROM TOP iv <br />TRACK <br />EXISTING WOOD <br />' <br />OR MTL. DECK <br />CONT. 20 GA. 3 $" OR 6" MTL. STUD___x <br />TOP TRACK WITH 4" SLOTTED <br />LEGS: ATTACH TO LOW CELLS OF <br />I I <br />1/2" GYP BOARD <br />MTL. DECK OR WOOD DECK iv <br />ABOVE @ 48" O.C. WITH #8-18x4" <br />( I <br />ATTACHED TO TO <br />TRACK ONLY <br />HWH SELF TAPPING SCREWS, <br />G.C. TO VERIFY WOOD DECK ; <br />THICKNESS TO INSURE <br />FASTENERS DO NOT <br />I I <br />PENETRATE THE ROOFING <br />MEMBRANE. <br />I I <br />FINISH AS <br />SCHEDULED <br />METAL STUD <br />SPACER BAR NOT MORE THAN <br />12" FROM TOP OF STUD, TO BE <br />INSTALLED PER MANU. SPECS <br />IF <br />EXIST. EIFS <br />' <br />EXTERIOR FINISH <br />n <br />TO REMAIN <br />EXIST. WALL <br />EXIST. GYP <br />E <br />CONSTRUCTION <br />BOARD <br />- <br />TO REMAIN <br />FINISH AS <br />_ <br />I <br />SCHEDULED <br />REFERENCE A2.2 <br />( <br />METAL J TRIM TO <br />�- <br />MATCH <br />STOREFRONT <br />CONTINUOUS <br />BACKER ROD & <br />SEALANT, BOTH <br />SIDES <br />BACKER ROD AND <br />1" <br />SILICONE CAULK <br />LINE OF EIFS <br />JOINT <br />V.I.F. INSET TO <br />MATCH EXISTING <br />ADJACENT <br />STOREFRONT <br />')DETAIL - <br />STOREFRONT JAMB/HEAD <br />3" = 1'-0" <br />D0ETAIL - STUD SLIP JOINT <br />6 <br />3" = 1'-01, <br />1 NOT USED <br />sevan <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI 48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />0 REVISIONS <br />NO. I DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />CONSULTANT <br />m <br />CUSTOMER <br />PROJECT DESCRIPTION <br />STORE <br />41564 <br />SHEET TITLE <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-03-20 <br />DRAWN BY: FS/OA <br />REVIEWED BY: JK/JD <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN DESIGN SOLUTIONS, P.C. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT WITHOUT THE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN DESIGN SOLUTIONS, P.C. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN DESIGN SOLUTIONS, P.C. 2020 <br />SHEET NUMBER <br />A7.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.