Laserfiche WebLink
HEAT PUMP ROOFTOP UNIT SCHEDULE <br />MARK <br />MANUFACTURER <br />MODEL <br />NOMINAL <br />TONS <br />SUPPLY FAN <br />COOLING CAPACITY <br />(MBH) <br />EER1 <br />SEER <br />ING. HEAT <br />CAPACITY <br />@ 17°F <br />(MBH) <br />COP/ <br />HSPF <br />AUX. <br />HEATING <br />INPUT <br />(KW) <br />HEATING <br />SUPPLY <br />AIR TEMP <br />(OF) <br />ELECTRICAL DATA <br />WEIGHT <br />CFM <br />E.S.P. <br />(IN. WC) <br />OSA <br />(CFM) <br />TOTAL <br />SENSIBLE <br />V/PH <br />MCA <br />MOCP <br />RTU-1 <br />CARRIER <br />50HCQ-A06 <br />1 5 <br />2000 <br />0.5" <br />325 <br />61.5 <br />48.3 <br />15.2 <br />28.6 <br />8.2 <br />4.9 <br />90.9 <br />208/3 <br />47 <br />50 <br />803 <br />RTU-2 <br />CARRIER <br />50HCQ-A06 <br />1 5 <br />2000 <br />0.5" <br />325 <br />61.5 <br />48.3 <br />15.2 <br />28.6 <br />8.2 <br />4.9 <br />90.9 <br />208/3 <br />47 <br />50 <br />1 803 <br />NOTES (ALL NEW UNITS): <br />A. PROVIDE FILTER WITH EACH UNIT. <br />B. PROVIDE WITH FULLY MODULATING ECONOMIZER WITH ENTHALPY CONTROL. <br />C. PROVIDE CO2 SNNSOR WITH DEMAND CONTROL VENTILATION. <br />D. SMOKE DETECTORS TO BE PROVIDED AND INSTALLED BY CARRIER. LOCATE AS SHOWN ON PLAN. <br />CONDENSATE TRAP SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE TRAP OF ADEQUATE DEPTH TO PREVENT <br />F. STATIC FROM OVERCOMING TRAP SEAL. ROUTE TO NEAREST APPROVED RECEPTOR. <br />G. PROVIDE WITH STANDARD ROOF CURB AND ACCESSORIES. <br />H. OUTDOOR AMBIENT DESIGN TEMPERATURE 95 DEG.F. <br />J. SET FAN OPERATION TO CONTINUOUS. <br />K. TEMPERATURE SET POINTS DURING OCCUPIED HOURS; HEATING MODE: 66°F - COOLING MODE: 75°F. <br />PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR, FOR ADDITIONAL INFORMATION CONTACT NATIONAL ACCOUNT <br />L. REPRESENTATIVE BOBBY KIMBRELL (512) 267-3366, BOBBY.KIMBRELL@CARRIER.UTC.COM. <br />M. CONTACT AUTOMATED LOGIC (ALC) AT (866) 390-4275 FOR BUILDING ENERGY MANAGEMENT SYSTEM. <br />N. <br />P. PROVIDE WITH PRE -COATED OUTDOOR COILS WITHIN A 5 MILE RADIUS OF ANY SALT OR BRACKISH WATER. 1 <br />EXHAUST FAN SCHEDULE <br />MARK QUANTITY MANUFACTURER MODEL CFM E.S.P. (IN. WC) V/Ph WATTS CONTROL <br />EF-1 1 GREENHECK SP-13150 100 0.25" 120/1 129 LIGHT SWITCH <br />NOTES: <br />A. PROVIDE GRAVITY BACKDRAFT DAMPER. <br />B. PROVIDE SPRING VIBRATION ISOLATORS FOR HANGER ROD SUPPORTS. <br />C. TO BE PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR. FOR ADDITIONAL <br />INFORMATION CONTACT CHAD LITERKSY (214) 350-6871 EXT. 2140 WITH BARTOS INDUSTRIES, <br />OSA CALCULATIONS <br />CLASSIFICATION <br />AREA <br />CFM PER <br />PEOPLE <br />CFM PER <br />ZONE <br />FT2 <br />AREA FT2 <br />PERSONS <br />PERSON <br />EFFECTIVENESS <br />(AZ) <br />(Ra) <br />(PZ) <br />(Rp) <br />(EZ) <br />SUPERMARKET <br />2190 <br />0.12 <br />33 <br />7.5 <br />0.8 <br />VbZ= RpPZ+ RaAz <br />VOz= VbZ/ Ez <br />TOTAL REQUIRED: 638 <br />7.5*33+0.12*2190 = 511 <br />361 / 0.8 = 638 <br />TOTAL SUPPLIED: 650 <br />AIR BALANCE SCHEDULE <br />MARK <br />OUTSIDE <br />AIR CFM <br />EXHAUST <br />AIR CFM <br />RTU-1 <br />325 <br />RTU-2 <br />325 <br />EF-1 <br />100 <br />TOTAL <br />650 <br />100 <br />VERTICAL 1/4" X 2" SAMMY <br />3/8" ALL THREAD ANCHOR, <br />TYP OF2 <br />100F III IOT45001019 <br />3/8" HEX <br />NUT, TYP <br />LUSH -A -CLAMP 3/8" ALL <br />FIRMLY CLAMPED THREAD ROD o <br />TO PIPE, TYP <br />3/8" HEX0 <br />NUT, TYP <br />1 5/8" x 1 5/8" <br />3/8" CHANNEL NUT GALVANIZED UNISTRUT <br />WITH SPRING <br />PIPING INSULATION <br />AS PER SPECS. <br />L <br />REF. PLANS FOR <br />RUNOUT SIZES <br />O� <br />10 / <br />L = W/4, 4" MIN * 45' LEAD IN <br />SPIN -IN FITTINGS <br />W/ SCOOPS ARE <br />NOT ACCEPTABLE <br />FLEXIBLE DUCT FOR <br />FINAL CONNECTION ONLY: <br />6-0" MAX LENGTH, <br />0 I V I C lr l-i f11 V I l�/`i L r Lfl I V <br />AIR DEVICE SCHEDULE (NOT ALL AIR DEVICE MAY BE USED) <br />MARK <br />SERVICE <br />MANUFACTURER <br />MODEL <br />STYLE <br />FACE SIZE <br />NECK SIZE <br />FRAME <br />TYPE <br />NOTES <br />CD1 <br />SUPPLY <br />METAL*AIRE <br />V4004D-1 <br />ALUMINUM DOUBLE DEFLECTION WALL <br />SUPPLY GRILLE <br />20 X 10 <br />18 X 8 <br />SURFACE <br />A, B, C, D <br />CD2 <br />SUPPLY <br />METAL*HIRE <br />5700-6 AL <br />ROUND NECK CEILING DIFFUSER <br />24 X 24 <br />PER PLAN <br />LAY -IN <br />A, B, C, D <br />CD3 <br />SUPPLY <br />METAL*HIRE <br />5700-1 AL <br />ROUND NECK CEILING DIFFUSER <br />12 X 12 <br />PER PLAN <br />SURFACE <br />A, B, C, D <br />CD4 <br />SUPPLY <br />METAL*AIRS <br />V4004D-1 <br />ALUMINUM DOUBLE DEFLECTION WALL <br />SUPPLY GRILLE <br />14 X 8 <br />12 X 6 <br />SURFACE <br />A, B, C, D <br />CCD1 <br />SUPPLY & <br />RETURN <br />MICROMETL <br />1017-200A <br />ALUMINUM FLUSH MOUNT CONCENTRIC <br />DIFFUSER <br />48 X 24 <br />18"0 <br />SURFACE <br />A, C, D <br />TG1 <br />TRANSFER <br />METAL*HIRE <br />DGSF <br />ROUND NECK CEILING DIFFUSER <br />10 X 10 <br />8110 <br />SURFACE <br />A, B, C, D <br />RG1 <br />RETURN <br />METAL*AIRE <br />CC5-6 <br />EGGCRATE CEILING RETURN GRILLE <br />24 X 24 <br />22 X 22 <br />LAY -IN <br />A, B, C, D <br />RG2 <br />RETURN <br />METAL*AIRE <br />RH-1 <br />SIDEWALL RETURN GRILLE <br />32 X 18 <br />30 X 16 <br />SURFACE <br />A C D <br />GENERAL INFORMATION (ALL DEVICES): <br />1. ALL DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE, <br />2. ALL AIR DEVICES SHALL BE PROVIDED BY 7-ELEVEN AND INSTALLED BY THE CONTRACTOR. FOR <br />ADDITIONAL INFORMATION CONTACT CHAD LITERSKY (214) 350-6871 EXT. 2140 WITH BARTOS INDUSTRIES. <br />NOTES: <br />A. DIFFUSER NECK SIZE SHALL BE SAME AS BRANCH DUCT SIZE UNLESS NOTED OTHERWISE. <br />B. DAMPER AT TAKEOFF TO DEVICE. <br />C. STANDARD OFF-WHITE FINISH. <br />D. PROVIDE NECK FOR DUCT CONNECTION. <br />1. NOTES APPLY TO ALL MECHANICAL SHEETS. <br />2. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING <br />THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS AS THEY RELATE TO THIS WORK. NO <br />ADDITIONAL COMPENSATION SHALL BE ALLOWED DUE TO <br />LACK OF THIS KNOWLEDGE. <br />3. PROVIDE ALL MATERIALS FOR A COMPLETE <br />INSTALLATION IN ALL RESPECTS READY FOR INTENDED <br />USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL <br />CODES AND MANUFACTURER'S RECOMMENDATIONS. <br />4. LIGHTING FIXTURE LOCATIONS TAKE PRECEDENCE <br />OVER DIFFUSER LOCATIONS. COORDINATE WITH <br />ELECTRICAL CONTRACTOR AND FIRE PROTECTION <br />CONTRACTOR. <br />5. DUCTWORK IDENTIFICATION AND INSTALLATION TO <br />ADHERE TO GOVERNING CODES. <br />6. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS <br />AND REPRESENTATIVE OF THE INSIDE EQUIVALENT FREE <br />AREA REQUIRED TO MAINTAIN THE AIR FLOW SPECIFIED. <br />IF DUCT LINING IS REQUIRED, INCREASE DUCT SIZE TO <br />MAINTAIN ORIGINAL INSIDE DIMENSIONS. IF DUCT SIZES <br />NEED TO BE ALTERED FOR SPACE REQUIREMENTS, <br />ENSURE THE ORIGINAL INSIDE DUCT EQUIVALENT FREE <br />AREA IS MAINTAINED. <br />7. TYPICAL BRANCH DUCT FITTING DETAIL IS APPLICABLE <br />THROUGHOUT. FLEXIBLE DUCTWORK IS ONLY PERMITTED <br />FOR FINAL CONNECTION - MAX LENGTH OF 6-0". <br />8. FURNISH AND INSTALL VOLUME/BALANCE DAMPERS AT <br />ALL BRANCH DUCTS TO DIFFUSERS. LOCATE DAMPERS A <br />MINIMUM 4'-0" AWAY FROM DIFFUSERS, PROVIDE ACCESS <br />AS REQUIRED. <br />9. PROVIDE A COMPLETE TEST AND BALANCE FOR HVAC <br />SYSTEM. AIR BALANCE SHALL BE WITHIN 5% OF <br />SCHEDULED AIRFLOWS. PROVIDE A COPY TO THE OWNER <br />AND ENGINEER. <br />10. INSTALL VTR'S AND EXHAUST FANS A MINIMUM OF 10 FT <br />FROM OUTSIDE AIR INTAKE. <br />MECHANICAL SYMBOLS (NOT <br />ALL SYMBOLS MAY BE USED) <br />18/12 <br />RECTANGULAR DUCT 18" WIDE <br />BY 12" DEEP (INSIDE CLEAR DIMENSIONS) <br />12" <br />12" DIAMETER ROUND DUCT <br />(INSIDE CLEAR DIMENSIONS) <br />SUPPLY DUCT IN SECTION <br />RETURN OR EXHAUST DUCT IN SECTION <br />'. <br />a <br />ELBOW WITH TURNING VANES <br />TEE WITH TURNING VANES <br />ROUND (OR OVAL) ELBOW <br />SUPPLY AIR DIFFUSER WITH <br />ROUND SUPPLY DUCT <br />RETURN OR EXHAUST AIR DIFFUSER <br />WITH ROUND DUCT <br />CD <br />400 CFM <br />DIFFUSER OR GRILLE TYPE & CFM <br />O <br />THERMOSTAT <br />O <br />SPACE TEMP. SENSOR <br />O <br />CO2SENSOR <br />OD <br />SMOKE DETECTOR <br />L K) <br />SMOKE DETECTOR TEST/RESET STATION <br />BALANCE DAMPER <br />COMMISSIONING AND T&B REQUIRED AND A REPORT <br />GENERATED USING 7-ELEVEN'S COMMISSIONING REPORT <br />TEMPLATE. PROVIDE A COPY TO THE OWNER AND ENGINEER. <br />IF HVAC SYSTEM AIRFLOW CANNOT BE BALANCED PER PLANS, <br />CONTACT ENGINEER OF RECORD FOR RESOLUTION. <br />REF EMS1.0 SHEET FOR ADDITIONAL INFORMATION REGARDING <br />THE BUILDING ENERGY MANAGEMENT SYSTEM CONTROLS. <br />CONTACT AUTOMATED LOGIC (ALC) AT (866) 390-4275 UPON <br />AWARD OF CONTRACT TO OBTAIN LIST OF CERTIFIED EMS <br />INSTALLERS. DURING CONSTRUCTION, AT 2 WEEKS PRIOR TO <br />BUILDING TURNOVER, CONTACT ALC TO COORDINATE DELIVERY <br />OF EMS PANEL. AFTER INSTALLATION OF EMS PANEL INCLUDING <br />CONNECTION OF CABLES, CONTACT ALC FOR START-UP OF EMS <br />PANEL. START-UP TO BE DONE 2-3 DAYS PRIOR TO BUILDING <br />TURNOVER. <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI 48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />/#\ REVISIONS I <br />N0. I DATE I DESCRIPTION <br />I 1 1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />II CONSULTANT II <br />11 CUSTOMER <br />PROJECT DESCRIPTION <br />I �l <br />PROJECT LOCATION <br />FIMITTYAWITIFNE <br />WAY <br />EVERETT, WA F • <br />11 SHEET TITLE 11 <br />......:.... <br />An <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-07-20 <br />DRAWN BY: JS <br />REVIEWED BY: JT <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN MULTI -SITE SOLUTIONS, INC. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT WITHOUTTHE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN MULTI -SITE SOLUTIONS, INC. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN MULTI -SITE SOLUTIONS, INC. 2013 <br />SHEET NUMBER <br />1.0 <br />AIL <br />L___ <br />