607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
>
Address Records
>
SE EVERETT MALL WAY
>
607
>
7 ELEVEN
>
Plans
>
607 SE EVERETT MALL WAY 2020 7 ELEVEN Plans 2022-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2022 11:20:51 AM
Creation date
10/24/2022 10:23:53 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
607
Tenant Name
7 ELEVEN
Permit
B2008-029
Year
2020
Notes
CREATE RETAIL SPACES IN THE FORMER CONVENIENCE STORE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HEAT PUMP ROOFTOP UNIT SCHEDULE <br />MARK <br />MANUFACTURER <br />MODEL <br />NOMINAL <br />TONS <br />SUPPLY FAN <br />COOLING CAPACITY <br />(MBH) <br />EER1 <br />SEER <br />ING. HEAT <br />CAPACITY <br />@ 17°F <br />(MBH) <br />COP/ <br />HSPF <br />AUX. <br />HEATING <br />INPUT <br />(KW) <br />HEATING <br />SUPPLY <br />AIR TEMP <br />(OF) <br />ELECTRICAL DATA <br />WEIGHT <br />CFM <br />E.S.P. <br />(IN. WC) <br />OSA <br />(CFM) <br />TOTAL <br />SENSIBLE <br />V/PH <br />MCA <br />MOCP <br />RTU-1 <br />CARRIER <br />50HCQ-A06 <br />1 5 <br />2000 <br />0.5" <br />325 <br />61.5 <br />48.3 <br />15.2 <br />28.6 <br />8.2 <br />4.9 <br />90.9 <br />208/3 <br />47 <br />50 <br />803 <br />RTU-2 <br />CARRIER <br />50HCQ-A06 <br />1 5 <br />2000 <br />0.5" <br />325 <br />61.5 <br />48.3 <br />15.2 <br />28.6 <br />8.2 <br />4.9 <br />90.9 <br />208/3 <br />47 <br />50 <br />1 803 <br />NOTES (ALL NEW UNITS): <br />A. PROVIDE FILTER WITH EACH UNIT. <br />B. PROVIDE WITH FULLY MODULATING ECONOMIZER WITH ENTHALPY CONTROL. <br />C. PROVIDE CO2 SNNSOR WITH DEMAND CONTROL VENTILATION. <br />D. SMOKE DETECTORS TO BE PROVIDED AND INSTALLED BY CARRIER. LOCATE AS SHOWN ON PLAN. <br />CONDENSATE TRAP SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. PROVIDE TRAP OF ADEQUATE DEPTH TO PREVENT <br />F. STATIC FROM OVERCOMING TRAP SEAL. ROUTE TO NEAREST APPROVED RECEPTOR. <br />G. PROVIDE WITH STANDARD ROOF CURB AND ACCESSORIES. <br />H. OUTDOOR AMBIENT DESIGN TEMPERATURE 95 DEG.F. <br />J. SET FAN OPERATION TO CONTINUOUS. <br />K. TEMPERATURE SET POINTS DURING OCCUPIED HOURS; HEATING MODE: 66°F - COOLING MODE: 75°F. <br />PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR, FOR ADDITIONAL INFORMATION CONTACT NATIONAL ACCOUNT <br />L. REPRESENTATIVE BOBBY KIMBRELL (512) 267-3366, BOBBY.KIMBRELL@CARRIER.UTC.COM. <br />M. CONTACT AUTOMATED LOGIC (ALC) AT (866) 390-4275 FOR BUILDING ENERGY MANAGEMENT SYSTEM. <br />N. <br />P. PROVIDE WITH PRE -COATED OUTDOOR COILS WITHIN A 5 MILE RADIUS OF ANY SALT OR BRACKISH WATER. 1 <br />EXHAUST FAN SCHEDULE <br />MARK QUANTITY MANUFACTURER MODEL CFM E.S.P. (IN. WC) V/Ph WATTS CONTROL <br />EF-1 1 GREENHECK SP-13150 100 0.25" 120/1 129 LIGHT SWITCH <br />NOTES: <br />A. PROVIDE GRAVITY BACKDRAFT DAMPER. <br />B. PROVIDE SPRING VIBRATION ISOLATORS FOR HANGER ROD SUPPORTS. <br />C. TO BE PROVIDED BY 7-ELEVEN AND INSTALLED BY CONTRACTOR. FOR ADDITIONAL <br />INFORMATION CONTACT CHAD LITERKSY (214) 350-6871 EXT. 2140 WITH BARTOS INDUSTRIES, <br />OSA CALCULATIONS <br />CLASSIFICATION <br />AREA <br />CFM PER <br />PEOPLE <br />CFM PER <br />ZONE <br />FT2 <br />AREA FT2 <br />PERSONS <br />PERSON <br />EFFECTIVENESS <br />(AZ) <br />(Ra) <br />(PZ) <br />(Rp) <br />(EZ) <br />SUPERMARKET <br />2190 <br />0.12 <br />33 <br />7.5 <br />0.8 <br />VbZ= RpPZ+ RaAz <br />VOz= VbZ/ Ez <br />TOTAL REQUIRED: 638 <br />7.5*33+0.12*2190 = 511 <br />361 / 0.8 = 638 <br />TOTAL SUPPLIED: 650 <br />AIR BALANCE SCHEDULE <br />MARK <br />OUTSIDE <br />AIR CFM <br />EXHAUST <br />AIR CFM <br />RTU-1 <br />325 <br />RTU-2 <br />325 <br />EF-1 <br />100 <br />TOTAL <br />650 <br />100 <br />VERTICAL 1/4" X 2" SAMMY <br />3/8" ALL THREAD ANCHOR, <br />TYP OF2 <br />100F III IOT45001019 <br />3/8" HEX <br />NUT, TYP <br />LUSH -A -CLAMP 3/8" ALL <br />FIRMLY CLAMPED THREAD ROD o <br />TO PIPE, TYP <br />3/8" HEX0 <br />NUT, TYP <br />1 5/8" x 1 5/8" <br />3/8" CHANNEL NUT GALVANIZED UNISTRUT <br />WITH SPRING <br />PIPING INSULATION <br />AS PER SPECS. <br />L <br />REF. PLANS FOR <br />RUNOUT SIZES <br />O� <br />10 / <br />L = W/4, 4" MIN * 45' LEAD IN <br />SPIN -IN FITTINGS <br />W/ SCOOPS ARE <br />NOT ACCEPTABLE <br />FLEXIBLE DUCT FOR <br />FINAL CONNECTION ONLY: <br />6-0" MAX LENGTH, <br />0 I V I C lr l-i f11 V I l�/`i L r Lfl I V <br />AIR DEVICE SCHEDULE (NOT ALL AIR DEVICE MAY BE USED) <br />MARK <br />SERVICE <br />MANUFACTURER <br />MODEL <br />STYLE <br />FACE SIZE <br />NECK SIZE <br />FRAME <br />TYPE <br />NOTES <br />CD1 <br />SUPPLY <br />METAL*AIRE <br />V4004D-1 <br />ALUMINUM DOUBLE DEFLECTION WALL <br />SUPPLY GRILLE <br />20 X 10 <br />18 X 8 <br />SURFACE <br />A, B, C, D <br />CD2 <br />SUPPLY <br />METAL*HIRE <br />5700-6 AL <br />ROUND NECK CEILING DIFFUSER <br />24 X 24 <br />PER PLAN <br />LAY -IN <br />A, B, C, D <br />CD3 <br />SUPPLY <br />METAL*HIRE <br />5700-1 AL <br />ROUND NECK CEILING DIFFUSER <br />12 X 12 <br />PER PLAN <br />SURFACE <br />A, B, C, D <br />CD4 <br />SUPPLY <br />METAL*AIRS <br />V4004D-1 <br />ALUMINUM DOUBLE DEFLECTION WALL <br />SUPPLY GRILLE <br />14 X 8 <br />12 X 6 <br />SURFACE <br />A, B, C, D <br />CCD1 <br />SUPPLY & <br />RETURN <br />MICROMETL <br />1017-200A <br />ALUMINUM FLUSH MOUNT CONCENTRIC <br />DIFFUSER <br />48 X 24 <br />18"0 <br />SURFACE <br />A, C, D <br />TG1 <br />TRANSFER <br />METAL*HIRE <br />DGSF <br />ROUND NECK CEILING DIFFUSER <br />10 X 10 <br />8110 <br />SURFACE <br />A, B, C, D <br />RG1 <br />RETURN <br />METAL*AIRE <br />CC5-6 <br />EGGCRATE CEILING RETURN GRILLE <br />24 X 24 <br />22 X 22 <br />LAY -IN <br />A, B, C, D <br />RG2 <br />RETURN <br />METAL*AIRE <br />RH-1 <br />SIDEWALL RETURN GRILLE <br />32 X 18 <br />30 X 16 <br />SURFACE <br />A C D <br />GENERAL INFORMATION (ALL DEVICES): <br />1. ALL DIFFUSERS ARE 4-WAY THROW UNLESS NOTED OTHERWISE, <br />2. ALL AIR DEVICES SHALL BE PROVIDED BY 7-ELEVEN AND INSTALLED BY THE CONTRACTOR. FOR <br />ADDITIONAL INFORMATION CONTACT CHAD LITERSKY (214) 350-6871 EXT. 2140 WITH BARTOS INDUSTRIES. <br />NOTES: <br />A. DIFFUSER NECK SIZE SHALL BE SAME AS BRANCH DUCT SIZE UNLESS NOTED OTHERWISE. <br />B. DAMPER AT TAKEOFF TO DEVICE. <br />C. STANDARD OFF-WHITE FINISH. <br />D. PROVIDE NECK FOR DUCT CONNECTION. <br />1. NOTES APPLY TO ALL MECHANICAL SHEETS. <br />2. EACH CONTRACTOR IS RESPONSIBLE FOR HAVING <br />THOROUGH KNOWLEDGE OF ALL DRAWINGS AND <br />SPECIFICATIONS AS THEY RELATE TO THIS WORK. NO <br />ADDITIONAL COMPENSATION SHALL BE ALLOWED DUE TO <br />LACK OF THIS KNOWLEDGE. <br />3. PROVIDE ALL MATERIALS FOR A COMPLETE <br />INSTALLATION IN ALL RESPECTS READY FOR INTENDED <br />USE AND IN STRICT ACCORDANCE WITH STATE AND LOCAL <br />CODES AND MANUFACTURER'S RECOMMENDATIONS. <br />4. LIGHTING FIXTURE LOCATIONS TAKE PRECEDENCE <br />OVER DIFFUSER LOCATIONS. COORDINATE WITH <br />ELECTRICAL CONTRACTOR AND FIRE PROTECTION <br />CONTRACTOR. <br />5. DUCTWORK IDENTIFICATION AND INSTALLATION TO <br />ADHERE TO GOVERNING CODES. <br />6. DUCT SIZES INDICATED ARE INSIDE CLEAR DIMENSIONS <br />AND REPRESENTATIVE OF THE INSIDE EQUIVALENT FREE <br />AREA REQUIRED TO MAINTAIN THE AIR FLOW SPECIFIED. <br />IF DUCT LINING IS REQUIRED, INCREASE DUCT SIZE TO <br />MAINTAIN ORIGINAL INSIDE DIMENSIONS. IF DUCT SIZES <br />NEED TO BE ALTERED FOR SPACE REQUIREMENTS, <br />ENSURE THE ORIGINAL INSIDE DUCT EQUIVALENT FREE <br />AREA IS MAINTAINED. <br />7. TYPICAL BRANCH DUCT FITTING DETAIL IS APPLICABLE <br />THROUGHOUT. FLEXIBLE DUCTWORK IS ONLY PERMITTED <br />FOR FINAL CONNECTION - MAX LENGTH OF 6-0". <br />8. FURNISH AND INSTALL VOLUME/BALANCE DAMPERS AT <br />ALL BRANCH DUCTS TO DIFFUSERS. LOCATE DAMPERS A <br />MINIMUM 4'-0" AWAY FROM DIFFUSERS, PROVIDE ACCESS <br />AS REQUIRED. <br />9. PROVIDE A COMPLETE TEST AND BALANCE FOR HVAC <br />SYSTEM. AIR BALANCE SHALL BE WITHIN 5% OF <br />SCHEDULED AIRFLOWS. PROVIDE A COPY TO THE OWNER <br />AND ENGINEER. <br />10. INSTALL VTR'S AND EXHAUST FANS A MINIMUM OF 10 FT <br />FROM OUTSIDE AIR INTAKE. <br />MECHANICAL SYMBOLS (NOT <br />ALL SYMBOLS MAY BE USED) <br />18/12 <br />RECTANGULAR DUCT 18" WIDE <br />BY 12" DEEP (INSIDE CLEAR DIMENSIONS) <br />12" <br />12" DIAMETER ROUND DUCT <br />(INSIDE CLEAR DIMENSIONS) <br />SUPPLY DUCT IN SECTION <br />RETURN OR EXHAUST DUCT IN SECTION <br />'. <br />a <br />ELBOW WITH TURNING VANES <br />TEE WITH TURNING VANES <br />ROUND (OR OVAL) ELBOW <br />SUPPLY AIR DIFFUSER WITH <br />ROUND SUPPLY DUCT <br />RETURN OR EXHAUST AIR DIFFUSER <br />WITH ROUND DUCT <br />CD <br />400 CFM <br />DIFFUSER OR GRILLE TYPE & CFM <br />O <br />THERMOSTAT <br />O <br />SPACE TEMP. SENSOR <br />O <br />CO2SENSOR <br />OD <br />SMOKE DETECTOR <br />L K) <br />SMOKE DETECTOR TEST/RESET STATION <br />BALANCE DAMPER <br />COMMISSIONING AND T&B REQUIRED AND A REPORT <br />GENERATED USING 7-ELEVEN'S COMMISSIONING REPORT <br />TEMPLATE. PROVIDE A COPY TO THE OWNER AND ENGINEER. <br />IF HVAC SYSTEM AIRFLOW CANNOT BE BALANCED PER PLANS, <br />CONTACT ENGINEER OF RECORD FOR RESOLUTION. <br />REF EMS1.0 SHEET FOR ADDITIONAL INFORMATION REGARDING <br />THE BUILDING ENERGY MANAGEMENT SYSTEM CONTROLS. <br />CONTACT AUTOMATED LOGIC (ALC) AT (866) 390-4275 UPON <br />AWARD OF CONTRACT TO OBTAIN LIST OF CERTIFIED EMS <br />INSTALLERS. DURING CONSTRUCTION, AT 2 WEEKS PRIOR TO <br />BUILDING TURNOVER, CONTACT ALC TO COORDINATE DELIVERY <br />OF EMS PANEL. AFTER INSTALLATION OF EMS PANEL INCLUDING <br />CONNECTION OF CABLES, CONTACT ALC FOR START-UP OF EMS <br />PANEL. START-UP TO BE DONE 2-3 DAYS PRIOR TO BUILDING <br />TURNOVER. <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI 48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />/#\ REVISIONS I <br />N0. I DATE I DESCRIPTION <br />I 1 1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />II CONSULTANT II <br />11 CUSTOMER <br />PROJECT DESCRIPTION <br />I �l <br />PROJECT LOCATION <br />FIMITTYAWITIFNE <br />WAY <br />EVERETT, WA F • <br />11 SHEET TITLE 11 <br />......:.... <br />An <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-07-20 <br />DRAWN BY: JS <br />REVIEWED BY: JT <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN MULTI -SITE SOLUTIONS, INC. <br />REPRODUCTION OR ALTERATION OF THIS DOCUMENT WITHOUTTHE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN MULTI -SITE SOLUTIONS, INC. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN MULTI -SITE SOLUTIONS, INC. 2013 <br />SHEET NUMBER <br />1.0 <br />AIL <br />L___ <br />
The URL can be used to link to this page
Your browser does not support the video tag.