FBD-DRC <br />CONDENSING UNIT <br />M <br />OVERALL SLURPEE MACL! (EACH I (QUID <br />AND DISCHARGE REFRIGERANT LINE LENGTHS <br />DESIGN NOTES: <br />PRE -CHARGED REFRIGERATION LINESETS ARE PROVIDED BY <br />THE VENDOR, IN 50' SECTIONS, WITH 5/8"DS & 3/8"L (EF-1 295) <br />* DESIGN LINE LENGTH = 22728' <br />® COMPRESSOR LOCATED IN FBD UNIT <br />REFER TO FBD INSTALLATION MANUAL. <br />HTTPS://DOWNLOADS.FBDFROZEN.COM/DOWNLOADS/DOWNLOAD/272 <br />7- BOHN <br />0- BCH0005MBACZ <br />Q) CONDENSING UNIT <br />ii <br />r, <br />7®3 0 <br />�4f <br />OVERALL ICE MERCHANDISER LIQUID AND <br />SUCTION REFRIGERANT LINE LENGTHS <br />DESIGN NOTES: <br />LINE SIZING TABLE 9 FROM THE; MANUAL SHOWS 6,000 BTUH <br />REQUIRES A 1/2" SUCTION FOR UP TO 50' OF EQUIVALENT LINE; <br />LENGTH. <br />® HORIZONTAL SUCTION LINES SHALL SLOPE AWAY FROM THE <br />EVAPORATOR TOWARD THE COMPRESSOR AT THE RATE OF 1/4" <br />PER 10' FOR SUFFICIENT OIL RETURN. <br />PIPING DIAGRAM FOR THE R-448-A LOW <br />TEMPERATURE (+107 SST) FREEZER REFRIGERATION SYSTEM <br />3/8" LIQUID LINE <br />TO CONDENSING <br />UNIT <br />5/8" DISCHARGE LINE <br />INSULATED WITH 3/4" <br />WALL ARMAFLFX OR <br />EQUAL <br />-6 <br />FBD-SRC <br />CONDENSING UNIT <br />.7 <br />ENLARGED INTERIOR SLURPEE MACOVERALL LEMONADE MACHINE LIQUID AND <br />DISCHARGE REFRIGERANT LINE SIZES AND CONNECTIONS DISCHARGE REFRIGERANT LINE LENGTHS <br />INSTALLATION NOTES: DESIGN NOTES: <br />® MAXIMUM LINE; LENGTH SHALL NOT EXCEED 50' ® PRE; -CHARGED REFRIGERATION LINESETS ARE PROVIDED BY <br />0 LINES SETS SHALL BE MEASURED AND CUT TO FIT TOTAL THE VENDOR, IN 50' SECTIONS, WITH 5/8"DS & 3/8"L (EF-1 295) <br />DEVELOPED LENGTH AS TO NOT HAVE ANY REMAINING COIL 0 DESIGN LINE LENGTH = 21' <br />OF TUBING ON -SITE ® COMPRESSOR LOCATED IN FBD UNIT <br />TO CONDENSING <br />UNIT <br />3/8" LIQUID LINE: <br />L <br />S <br />BEACON ELECTRIC — <br />EXPANSION VALVE (TYP.) 1/2" SUCTION LINE <br />FACTORY INSTALLED INSULATED WITH 3/4" <br />WALL ARMAFLFX OR <br />EQUAL <br />ENLARGED INTERIOR ICE MERCHANDISER LIQUID AND <br />SUCTION REFRIGERANT LINE SIZES AND CONNECTIONS <br />LINE SIZING - 1,000 BTUH <br />0 (8) 1/2" ELBOWS: EQUIVALENT LINE LENGTH = 8' <br />a PIPING LENGTH = 31' <br />0 TOTAL DEVELOPED LENGTH = 39' <br />0 SUCTION LINE SIZE = 3/8" <br />0 LIQUID LINE: SIZES = 3/8" <br />... -. fi <br />al afla <br />REFER TO FBD INSTALLATION MANUAL. <br />HTTPS-,HDOWNLOADS.FBDFROZEN.COM/DOWNLOADS/DOWNLOAD/272 <br />} <br />BOHN <br />BCH0008LBACZ <br />CONDENSING UNIT <br />J VJ <br />yn <br />0 <br />VAULT FREEZER LIQUID AND SUCTION <br />REFRIGERANT LINE LENGTHS <br />DESIGN NOTES: <br />0 DESIGN LENGTH = 50' <br />0. COMPRESSOR LOCATED IN 2-DOOR FREEZER UNIT <br />PIPING DIAGRAM FOR THE R-448-A LOW <br />TEMPERATURE (-20°F SST) FREEZER REFRIGERATION SYSTEM <br />REFER TO REFRIGERATION INSTALLATION MANUAL FOR LONGER LINE RUNS. <br />HTTP:/N ilk/V.HEATCRAFTRPD.COM/PDF/I&O/H-IM-CU.PDF <br />I <br />---- <br />TO CONDENSING <br />UNIT <br />3/8" LIQUID LINE; <br />L <br />f <br />ENLARGED INTERIOR LEMONADE MACHINE LIQUID AND <br />3/8" LIQUID LINE - <br />L <br />S <br />7/8" SUCTION LINE <br />INSULATED WITH 3/4" <br />WALL ARMAFLFX OR <br />EQUAL <br />ENLARGED INTERIOR VAULT FREEZER LIQUID AND <br />SUCTION REFRIGERANT LINE SIZES AND CONNECTIONS <br />LINE SIZING - 2,500 BTUH (cs7 -20°F: <br />0 (6) 7/8" ELBOWS: EQUIVALENT LINE LENGTH = 6' <br />0 PIPING LENGTH = 26' <br />® TOTAL DEVELOPED LENGTH = 32' <br />0 SUCTION LINE SIZE; = 1/2" <br />0 LIQUID LINE SIZE = 3/8" <br />SANDWICH CASE LIQUID AND SUCTION <br />REFRIGERANT LINE LENGTHS <br />DESIGN NOTES: <br />REFRIGERATION LINESETS ARE PROVIDED BY THE VENDOR, <br />IN 50' SECTIONS, WITH 3/4"S & 3/8°L (EF-1 #656) <br />® DESIGN LINE LENGTH = 15' <br />HORIZONTAL SUCTION LINES SHOULD SLOPE DOWNWARD <br />FROM THE EVAPORATOR TOWARD THE COMPRESSOR AT <br />THE RATE OF 1/4 INCH PER 10 FEET FOR GOOD OIL RETURN <br />TO THE COMPRESSOR. <br />PIPING DIAGRAM FOR THE R-448-A MEDIUM <br />TEMPERATURE (+20°F SST) COOLER REFRIGERATION SYSTEM <br />HOSHIZAKI URC-5F <br />CONDENSING UNIT <br />c� <br />Fa � <br />�J <br />ICE MAKER LIQUID AND DISCHARGE 71 <br />REFRIGERANT LINE LENGTHS <br />DESIGN NOTES: <br />a PRE -CHARGED REFRIGERATION LINESETS ARE PROVIDED BY <br />THE VENDOR, IN 35SECTIONS, WITH 3/8"DS & 1/4"L (EF-1 #112) <br />® DESIGN LINE LENGTH = 16' <br />a COMPRESSOR LOCATED IN ICE MAKER <br />REFER TO HOSHIZAKI INSTALLATION MANUAL. <br />HTTP:IIVVV V.H0SHIZAKI.COM/DOCS/MANUALS/FLAKEeR IS BC INST.PDF <br />TO CONDENSING <br />UNIT <br />3/8" LIQUID LINE <br />-S <br />x� <br />3/4°' SUCTION LINF <br />INSULATED WITH 3/4" <br />WALL ARMAFLFX OR <br />EQUAL <br />TO CONDENSING <br />UNIT <br />1/4" LIQUID LINE <br />L <br />DS <br />3/8" DISCHARGE LINE <br />INSULATED WITH 3/4" <br />WALL ARMAFLFX OR <br />EQUAL <br />i <br />INSTALLATION NOTES: <br />0 MAXIMUM LINE LENGTH SHALL NOT EXCEED 66' <br />® LINE: SETS SHALL BE MEASURED AND CUT TO FIT TOTAL <br />DEVELOPED LENGTH AS TO NOT HAVE ANY REMAINING COIL <br />OF TUBING ON -SITE <br />® MAXIMUM RISE IS 33' <br />TO CONDENSING <br />1/2" LIQUID —� � UNIT <br />OVERALL VAULT COOLER LIQUID AND ENLARGED INTERIOR VAULT COOLER LIQUID AND <br />SUCTION REFRIGERANT LINE LENGTHS SUCTION REFRIGERANT LINE SIZES AND CONNECTIONS <br />DESIGN NOTES: LINE SIZING - 31 200 BTUH ±20°F: <br />® LINE SIZING TABLE 9 FROM THE MANUAL SHOWS 36,000 BTUH 0 (6) 1-1/8" ELBOWS: EQUIVALENT LINE LENGTH = 18' <br />REQUIRES A 1-1/8" SUCTION FOR UP TO 1 00'OF EQUIVALENT a (2) 1-1/8" TEES: EQUIVALENT LINE LENGTH = 6' <br />LINE LENGTH. ® (2) 7/8" ELBOWS: EQUIVALENT LINE LENGTH = 4' <br />0 HORIZONTAL SUCTION LINES SHALL SLOPE AWAY FROM THE ® PIPING LENGTH 49' <br />EVAPORATOR TOWARD THE COMPRESSOR AT THE RATE OF 1/4" ® TOTAL DEVELOPED LENGTH - 77' <br />PER 10' FOR SUFFICIENT OIL RETURN. <br />® FOR MULTIPLE EVAPORATORS CONNECTED IN SERIES USING A a SUCTION LINE SIZE = 1-1/8" <br />COMMON SUCTION LINE, THE BRANCH SUCTION LINES MUST 0LIQUID LINE SIZE = 1/2" <br />ENTER THE: TOP OF THE COMMON SUCTION LINE, <br />PIPING DIAGRAM FOR THE R-448-A MEDIUM <br />TEMPERATURE (+20°F SST) COOLER REFRIGERATION SYSTEM <br />t IMMMi .. <br />REVISIONS <br />NO. DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />CONSULTANT <br />Engineers, Inc. <br />760 Creel Drive <br />wood Dale, Winds 6011 1 <br />Tel, 301 95.8800 <br />Fax 630/5 -88`I8 <br />'4v4r�r'a.W�l1Fe;ri ��r��c.rL,�t;ttt <br />SEAL <br />igc <br />OR <br />41, <br />411 <br />,� <br />ISSUEb DATE: 11/04/20 <br />t�ROJLC`L DESC�II�TIOF�1 <br />STORE # <br />SHEET TITLE <br />REFRIGERATION <br />PIPING RISER DETAILS <br />SMELT MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-07-20 <br />DRAWN BY: J5 <br />REVIEWED BY: JT <br />THIS DOCUMENT IS AND SHAM REMAIN THE PROPERTY OF <br />SEVAN MULTI -SITE SOLUTIONS, INC. <br />REPRODUCTION OR ALTERATION OPTHIS DOCUMENT WiTHOUTTHE EXPRESSE <br />WRITTEN PERMISSION OF SEVAN FAD IT SOLUTIONS, INC. IS PROM I BILLED. <br />,NOT PUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN MULTI SITE SOLUTIONS, INC. 2013 <br />1 SKEET NUMBED <br />M1.2 <br />