Laserfiche WebLink
PHONES <br />DESIGNATION <br />LINE <br />CONDUIT <br />SIZE <br />FROM <br />TO <br />T-49/50 <br />STORE VOICE LINE, <br />THROUGH <br />1" <br />TELEPHONE BOARD <br />BACK ROOM 10" X 10" <br />LOCATED AT SALES <br />CONDUIT <br />J-BOX & THEN TO <br />AREA & RIS WORK <br />FRONT SALES <br />STATION, <br />COUNTER <br />T-30 <br />MONEY ORDER, LONG <br />THROUGH <br />1" <br />TELEPHONE BOARD TO <br />FRONT SALES <br />DISTANCE CARDS <br />CONDUIT <br />RIS, FROM RIS 10" X 10" <br />COUNTER <br />(LDC) AND EBT (FOOD <br />TO SALES <br />STAMP PROGRAM) <br />T-39 <br />FAX LINE AT RIS <br />THROUGH <br />1" <br />TELEPHONE BOARD ABOVE <br />WORKSTATION <br />WORKSTATION <br />CONDUIT <br />CLG TO RIS 10" X 10" <br />T-75 <br />V-COM LINE <br />THROUGH <br />1" <br />TELEPHONE BOARD <br />ATM LOCATION <br />CONDUIT <br />NOTE: ALL PHONE LINES TRAVEL FROM DEMARC THROUGH 3" CONDUIT TO 10" X 10" J-BOX MOUNTED ABOVE ISP. <br />DATA <br />DESIGNATION <br />LINE <br />CONDUIT <br />SIZE <br />FROM <br />TO <br />D-1 <br />COMPUTER AT <br />IN SLAB <br />1" <br />10" X 10" J-BOX @ <br />SALES AREA <br />REGISTER #1 <br />WORKSTATION AREA <br />D-2 <br />COMPUTER AT <br />IN SLAB <br />1" <br />10" X 10" J-BOX @ <br />SALES AREA <br />REGISTER #2 <br />WORKSTATION AREA <br />D-3 <br />HOLD-UP BUTTON <br />IN SLAB <br />1" <br />MGRS OFFICE <br />SALES AREA - <br />REGISTER #1 <br />CAMERA SIGNAL <br />THROUGH CEILING <br />10" X 10" J-BOX @ <br />WORKSTATION AREA <br />D-4 <br />MONEY ORDER <br />IN SLAB <br />1" <br />10" X 10" J-BOX @ <br />WORKSTATION AREA <br />D-5 <br />ATG <br />THROUGH CONDUIT <br />1" <br />ISP DESK-ATG MONITOR <br />(ELECTRIC ROOM) <br />TO ELECTRIC ROOM <br />FUEL TANKS <br />D-6 <br />LOTTO <br />THROUGH CONDUIT <br />1" <br />10" X 10" J-BOX @ <br />SALES AREA <br />IN SLAB <br />WORKSTATION AREA <br />D-7 <br />ATM <br />THROUGH OVERHEAD <br />1" <br />10" X 10" J-BOX @ <br />VCOM WALL <br />CONDUIT <br />WORKSTATION AREA <br />NOTE: ALL DATA LINES TRAVEL FROM DEMARC THROUGH 3" CONDUIT TO 10" X 10" J-BOX IN CEILING, DOWN <br />THROUGH WALL INTO 10" X 10" J-BOX BEHIND RIS DESK. <br />In+. u. A onnoa za <br />CNi — n In %A' —I IT T1 nnD 01 API <br />NOTE: ALL LOW VOLTAGE CABLING SHALL BE RAN IN RACEWAY, <br />AND INSTALLED IN A CLEAN WORKMAN LIKE MANNER. THERE <br />SHALL BE NO EXPOSED CABLING IN THE SALES AREA. <br />(1) 1 "C TO ATM <br />(1) 1 "C TO ATG <br />(FUELING ONLY) <br />(1) 1 "C TO <br />MANAGER'S OFFICE <br />(1) 1 "C TO ACCESS <br />POINT- WALK IN <br />COOLER <br />(1) 1 "C TO ACCESS <br />POINT -SALES FLOOR <br />3" CONDUIT TO <br />J-BOX BELOW <br />INSTALL LIGHTING <br />OVERRIDE SWITCH <br />PROVIDED BY EMS. <br />REF EMS1.0 <br />10"x10" J-BOX <br />FOR DATA & <br />PHONE LINES <br />-- 10"x10" J-BOX IN SPACE <br />ABOVE WORKSTATION <br />-- - - (1) 3"C TO 10"x10" J-BOX ABOVE <br />j SALES COUNTER. STUB OUT (2) <br />\ !( 2"C INTO SALES COUNTER <br />- (1) 3"C TO <br />TELEPHONE BOARD <br />,-CEILING <br />,I <br />I <br />-/ -- -- - <br />= . --- <br />_ _ <br />iT 7 — <br />I <br />D-1,D-2 & —II <br />D- I�SWITCH p� <br />(IF USED �{ �D-6 <br />i \ 1� D-7 <br />12113 <br />ROUTER <br />VEEDER <br />ROOT <br />T-49/50 T-30 <br />T-39 <br />D-5 (FUEL <br />ONLY) <br />It. <br />TYPICAL WORKSTATION ELEVATION. MAY NEED <br />MODIFICATION PER ACTUAL CONDITIONS. <br />WORKSTATION WIRING -LOW VOLTAGE <br />N.T.S. <br />1 LOW VOLTAGE PLAN <br />1/4" = 1'-0" <br />(1) 1 "C TO WORKSTATION <br />(1) 1"C TO TELEPHONE <br />BOARD <br />T-49/5 <br />T-39 (I <br />1) 1"C TO VIDEO CAMERAS <br />1) 2"C TO SALES COUNTER <br />EILING <br />SECURITY ALARM PANEL <br />NETWORK SWITCH FOR <br />DIGITAL MENU BOARD <br />DESK <br />REFER TO ARCH INTERIOR OFFICE <br />ELEVATIONS FOR EXACT DIMENSIONS <br />3 MGR'S OFFICE WIRING -LOW VOLTAGE <br />N.T.S. <br />KEYNOTES - LOW VOLTAGE <br />ENERGY MANAGEMENT ENCLOSURE PROVIDED BY OTHERS. <br />MONITOR: ROUTE CONDUIT BACK TO VIDEO RECORDING <br />aVIEW <br />EQUIPMENT LOCATED IN MANAGER'S OFFICE. COORDINATE LOCATION <br />WITH SECURITY SYSTEM INSTALLER. REFER TO LOW VOLTAGE RISER <br />DIAGRAM FOR WIRING REQUIREMENTS. <br />TELEPHONE BOARD: 4'X4'X3/4" PLYWOOD WITH (1) #6 CU. <br />GROUND FOR FUTURE USE MOUNTED ABOVE 4'X4'X3/4" <br />PLYWOOD WITH (1) #6 CU. GROUND PER TELE. CO. <br />REQUIREMENTS. MOUNT RECEPTACLE ADJACENT TO OR <br />ABOVE TELEPHONE BOARD, DO NOT MOUNT BELOW. <br />CAMERA:ROUTE CONDUIT BACK TO VIDEO RECORDING <br />aSECURITY <br />EQUIPMENT LOCATED IN MANAGER'S OFFICE. COORDINATE LOCATION <br />WITH SECURITY SYSTEM INSTALLER. <br />VEEDER ROOT: COORDINATE INSTALLATION WITH FUELING PLANS. <br />INSTALL IN LOCATION. MOUNT AT 48" A.F,F. TO BOTTOM. <br />El <br />ROUTE WIRING FOR DATA DEVICES UNDER SLAB. <br />aMOUNT <br />+12'AFF, ROUTE CONDUIT BACK TO VIDEO RECORDING <br />EQUIPMENT LOCATED IN MANAGER'S OFFICE, COORDINATE LOCATION <br />WITH CONSTRUCTION MANAGER AND SECURITY SYSTEM INSTALLER. <br />ElNOT <br />USED, <br />WIRELESS INTERNET CONNECTION. THIS WILL BE THE <br />aCRADLEPOINT <br />LAST ISP RELATED DEVICE TO BE INSTALLED. THE LOCATION IN THE <br />STORE WILL BE BASED ON THE STRONGEST SIGNAL WITHIN THE STORE. <br />GUIDELINES FOR THE LOCATION OF THE CP ARE AS FOLLOWS: <br />• AS FARAWAY AS POSSIBLE FROM THE ELECTROMAGNETIC <br />INTERFERENCE (MOTORS) <br />• AS CLOSE TO THE CEILING AS POSSIBLE <br />• POSITIONED SO THE LED LIGHTING SIGNALS ARE VISIBLE FOR <br />TROUBLE SHOOTING / MAINTENANCE PURPOSES <br />• MAXIMUM OF 4-6" OF PATCH CABLE VISIBLE ON THE WALL (COLOR: <br />WHITE) <br />RJ11 FLUSH MOUNT FACE PLATE FOR ATM DATA LINE TO RIS <br />10 <br />COMPUTER WITH JACK TO BE LABELED 'ATM'. DATA LINE <br />IDENTIFIER. D-7 <br />11 <br />ACCESS POINT EXTENDED ANTENNA CABLES, FOUR CAT 6 CABLES, <br />RJ45 FEMALE IN A 4-PLEX, COVER PLATE LABELED TO 3 LOCATIONS <br />BELOW: <br />A. CAT6 RJ45 FEMALE JACK CENTER OF SALES FLOOR <br />SUSPENDED ABOVE CEILING TILE (MAY NEED TO MOVE LATER). <br />100' IN TOTAL LENGTH WITH EXTRA COILED AT FEMALE JACK <br />B. CAT6 RJ45 FEMALE JACK CENTER OF SALES FLOOR <br />SUSPENDED ABOVE CEILING TILE (MAY NEED TO MOVE LATER). <br />100' IN TOTAL LENGTH WITH EXTRA COILED AT FEMALE JACK. <br />C. CAT6 RJ45 FEMALE JACK IN RECEPTACLE 84" ABOVE FLOOR <br />- CENTER OF WALK-IN COOLER. <br />12 <br />DATA TELEPHONE CABLING PROVIDED BY LTCG. CONTACT <br />GREGORY LEVALDS (972) 801-9950. CONDUIT AND BOXES TO BE <br />FURNISHED BY OWNER AND INSTALLED BY G.C. <br />24"x36" FIRE RETARDANT U-TECK BACKBOARD SHALL BE PLACED <br />13 <br />BEHIND RIS MONITOR AND ABOVE WORKSTATION RECEPTACLES. <br />BACKBOARD WILL SUPPLY MOUNTING FOR SRX ROUTER AND RIS <br />SWITCH. PROVIDED AND INSTALLED BY LTCG. <br />FOUR DIGITAL MENU BOARDS (DMB) WITH MEDIA PLAYERS. <br />H <br />INCLUDED IN ALL U.S. NEW STORE PROJECTS AND ALL U.S. <br />REVITALIZATION PROJECTS (REBUILD, RELOCATION, MAJOR <br />REMODEL) EFFECTIVE 1/01/2018. HARDWARE SEI SUPPLIED <br />THROUGH CONTACT WITH AT&T (CONSOLIDATED PO TO AT&T <br />THROUGH TURNKEY RESOURCES). ELECTRICAL POWER AND LOW <br />VOLTAGE POWER BY GC. COMMISSIONING IS SEI SUPPLIED <br />THROUGH CONTRACT AT&T (DIRECT PO TO AT&T). SUBSCRIPTION <br />AND SERVICE AGREEMENT(S) BILLED DIRECT TO SEI IT <br />DEPARTMENT SEPARATE FROM CONSTRUCTION PROJECTS. <br />QSIC MUSIC SERVICE 3 SPEAKERS WITH CAT6 TERMINATED TO <br />15 <br />FEMAILE RJ45. DATA JACKS FOR SPEAKER TO BE FLUSH MOUNTED <br />DIRECTLY BEHIND SPEAKER. VERIFY EXACT HEIGHT AND LOCATION <br />WITH ARCHITECTURAL DRAWINGS. INSTALLER TO HIDE DATA CABLE <br />BEHIND THE SPEAKER USING CABLE TIES. <br />QSIC DATA AND SPEAKER WIRE TO COME OUT OF 6 WAY DATA <br />16 <br />OUTLET (DATA TO BE TERMINATED, BLANKS LEFT FOR SPEAKER <br />AND AVA WIRE TO COME OUT). <br />AVA WIRE TO TERMINATE IN BACK OF AVA SENSOR. MOUNT IN <br />17 <br />CEILING. <br />LOW VOLTAGE NOTES: <br />1. ALL WIRING IS COPPER. REFER TO ELECTRICAL SPECIFICATIONS FOR <br />FURTHER INFORMATION. <br />2. E.C. TO INSTALL DATA LINES IN CONDUIT TO BOXES INSTALLED BY LOW <br />VOLTAGE CONTRACTOR LTCG PRIOR TO TYCO CAMERA INSTALLATION. <br />3. CONDUITS THAT ARE EXPOSED TO WIDELY DIFFERENT TEMPERATURES, <br />SUCH AS COOLERS, FREEZERS OR SERVICE ENTRANCE CONDUCTORS, <br />SHALL BE SEALED TO PREVENT CIRCULATION OF AIR AND/OR MOISTURE. REF <br />2011 NEC (300.7 (A)) <br />4. CONDUIT AND WIRING IN AREAS WHERE EXPOSED SHALL BE ROUTED AT 90 <br />DEGREE ANGLES PERPENDICULAR OR PARALLEL TO JOISTS. COORDINATE <br />PAINTING OF CONDUIT WITH ARCHITECTURAL FINISHES. <br />5. CABLING FROM SATELLITE TO LOTTO MACHINE SHALL BE RAN THROUGH <br />THE ROOF PORTAL TO ABOVE THE DROP CEILING, IT SHALL STAY <br />CONCEALED ABOVE THE CEILING FROM THERE, TO ABOVE THE BACK <br />ROOM, THEN ROUTED DOWN THE WALL INTO THE FRONT COUNTER <br />TERMINATING AT THE LOTTO MACHINE. <br />6. UNLESS OTHERWISE DICTATED BY APPLICABLE CODES OR AHJ, ALL <br />MATERIALS WITHIN RETURN AIR PLENUM MUST BE NON COMBUSTIBLE <br />AND/OR HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A <br />SMOKE -DEVELOPED INDEX NOT MORE THAN 50 IN ACCORDANCE WITH ASTM <br />E 84 TESTING. <br />sevar <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI 48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY I <br />0 REVISIONS <br />NO. DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />I CONSULTANT <br />3343 NORTH RIDGE AVENUE �I <br />ARLINGTON HEIGHTS, IL 60004 <br />TEL (847) 966-0290 <br />WWW,DEI-PE.COM <br />SEAL <br />ti DICE <br />� o <br />j6 36369 9 <br />�OISTF?- <br />*. EXFYRES Q j( <br />SIGNATURE <br />DATE <br />11 PROJECT DESCRIPTION <br />STORE # <br />41564 <br />... C 1 <br />607 SE EVERETTA <br />EVERETT, WA WAY <br />208 <br />SHEET TITLE <br />11"i <br />0 <br />Ff' . <br />SHEET MANAGEMENT <br />PROJECT NO.: _ 41564 <br />DATE ISSUED: 08-10-20 <br />DRAWN BY: SR <br />REVIEWED BY: DD <br />THIS DOCU MENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN MULTI -SITE SOLUTIONS, INC. <br />REPRODUCTION OR ALTERATION OFTHIS DOCUMENT WITHOUTTHE EXPRESSED <br />WRITTEN PERMISSION OF SEVAN MULTI -SITE SOLUTIONS, INC. IS PROHIBITED. <br />INOTPUBLISHED: ALL RIGHTS RESERVED.) <br />COPYRIGHT BY SEVAN MULTI -SITE SOLUTIONS, INC. 2013 <br />I._SHEET NUMBER II <br />AM <br />