Laserfiche WebLink
1 <br />E2.0 <br />SC: 1/4" = 1 <br />G <br />GENERAL PLAN NOTES <br />1. EMERGENCY EXIT ILLUMINATION SHALL BE SUPPLIED <br />FROM STORAGE BATTERY THAT IS TO PROVIDE 90 <br />MINUTES OF CONTINUED ILLUMINATION IN CASE OF <br />A PRIMARY POWER LOSS. <br />2. THE BRANCH CIRCUIT FEEDING THE UNIT <br />EQUIPMENT (EMERGENCY LIGHT/EXIT SIGN <br />WITSELF-CONTAINED <br />RECHARGEABLE BATTERY) SHALL BE THE SAME <br />BRANCH CIRCUIT AS THAT SERVING THE NORMAL <br />LIGHTING IN THE AREA AND CONNECTED AHEAD OF <br />ANY LOCAL SWITCHES OR TIME CLOCKS AS SHOWN <br />ON PLAN. <br />3. EMERGENCY LUMINAIRES SHALL PROVIDE AN INITIAL <br />AVERAGE ILLUMINATION LEVEL OF AT LEAST 1 <br />FOOT-CANDLE BUT AT ANY POINT IT SHALL NOT BE <br />LESS THAN 0.1 FOOT-CANDLE ALONG THE PATH OF <br />EGRESS AT FLOOR LEVEL. <br />4. AT THE END OF THE REQUIRED EMERGENCY <br />SOURCE TIME DURATION, THE EMERGENCY <br />LUMINAIRES SHALL PROVIDE AN AVERAGE <br />ILLUMINATION LEVEL OF AT LEAST 0.6 FOOT-CANDLE <br />BUT AT ANY POINT IT SHALL NOT BE LESS THAN 0.06 <br />FOOT-CANDLE ALONG THE PATH OF EGRESS AT <br />FLOOR LEVEL. <br />5. THE EMERGENCY ILLUMINATION LEVEL SHALL HAVE <br />A MINIMUM -TO -MAXIMUM EMERGENCY ILLUMINATION <br />UNIFORMITY RATIO THAT DOES NOT EXCEED 40:1. <br />6. CONDUIT AND WIRING IN AREAS WHERE EXPOSED <br />SHALL BE ROUTED AT 90 DEGREE ANGLES <br />PERPENDICULAR OR PARALLEL TO JOISTS. <br />COORDINATE PAINTING OF CONDUIT WITH <br />ARCHITECTURAL FINISHES. <br />7. FOR LIGHTING CONTROLS IN THE SALES AND BACK <br />OF HOUSE AREA, SEE SHEET E2.1. <br />KEYNOTES - LIGHTING 1 <br />VENLITE MODEL PW-25-LC-V1 INVERTER FOR EMERGENCY LIGHTING CIRCUIT. SEE <br />ETAIL 2/E2.0 FOR WIRING DIAGRAM. CONTRACTOR TO ENSURE INVERTER SIZE <br />ATCHES EMERGENCY LIGHTING LOAD. <br />MERGENCY FIXTURE TO BE WIRED THROUGH INVERTER FOR 90 MINUTE <br />MERGENCY BACKUP. SEE DETAIL 2/E2.0 FOR WIRING DIAGRAM. <br />3W LED COOLER DOOR LIGHTS PROVIDED AND INSTALLED BY COOLER DOOR <br />ANUFACTURER, E.C. TO PROVIDE WIRING FOR COOLER/ FREEZER DOOR LIGHTS <br />ND CONNECT TO MANUFACTURER SUPPLIED JUNCTION BOX. <br />TYPE <br />A2 <br />MANUFACTURER <br />CREE <br />MODEL NUMBER <br />ZR22C-40L-40K-10V-FD <br />ORCALE NUMBER <br />3291295 <br />VOLTS/PHASE <br />120/277V, 1 <br />WATTS <br />40 <br />LAMP TYPE <br />LED <br />MOUNTING <br />RECESSED <br />DESCRIPTION <br />LED 2' X 2' RECESSED TROFFER; 0-10V-, 40K; 120/277V <br />OTY <br />6 <br />A2E <br />CREE <br />ZR22C-40L-40K-10V-FD-EB14 <br />3291297 <br />120/277V, 1 <br />40 <br />LED <br />RECESSED <br />LED 2' X 2' RECESSED TROFFER; 0-10V; 40K; 120/277V WITH EMERGENCY BATTERY <br />2 <br />A2sc <br />CREE <br />ZR22MT-40L-40K-CMA-FL <br />3291296 <br />120/277V, 1 <br />40 <br />LED <br />RECESSED <br />LED 2' X 2' RECESSED TROFFER; 0-10V; 40K; 120/277V WITH CMA CONTROL <br />38 <br />A2Esc <br />CREE <br />ZR22MT-40L-40K-CMA-EB14-FL <br />3291298 <br />120/277V, 1 <br />40 <br />LED <br />RECESSED <br />LED 2' X 2' RECESSED TROFFER; 0-10V; 40K; 120/277V WITH CMA CONTROL & EMERG BATTERY <br />7 <br />DS4E <br />EM <br />CREE <br />SIGNIFY / PHILLIPS <br />CR-LE-40L-40K-S-EB14 & <br />S -LE-L MK- <br />VLLU <br />3291305 <br />3299642 <br />120/277V, 1 <br />120/1 <br />33 <br />11 <br />LED <br />LED <br />SURFACE <br />UNIVERSAL <br />1X4 SURFACE MOUNT LIGHT; 4000K; 120/277V; WITH EMERGENCY BATTERY <br />EMERGENCY LED 2 LAMP WALL MOUNT <br />2 <br />1 <br />H <br />SIGNIFY / PHILLIPS <br />V3WEZ440L840-UNV <br />3299638 <br />120/277V, 1 <br />32 <br />LED <br />SURFACE <br />1X4 LED LINEAR STRIP, SURFACE MOUNT, GASKETED <br />4 <br />J8 <br />GE <br />GEW1109641 BAT-SY <br />- <br />120/277V, 1 <br />36 <br />LED <br />SURFACE <br />LED BATTEN 96"; 4000K <br />13 <br />N <br />SIGNIFY / PHILIPS <br />PLEMBZ <br />3299640 <br />120/277V, 1 <br />24 <br />LED <br />WALL <br />LED WALL MOUNT W/ EMERGENCY BATTERY BACK-UP; 8' A.F.F. <br />3 <br />X1 <br />SIGNIFY / PHILIPS <br />VERWEM <br />3299639 <br />120/277V, 1 <br />1 <br />LED <br />UNIVERSAL <br />LED EXIT (RED) LETTERS, EMERGENCY BATTERY BACK-UP <br />3 <br />5&van <br />DESIGN SOLUTIONS, P.C. <br />Corporate Office: <br />3025 Highland Parkway, Suite 850 <br />Downers Grove, IL 60515 <br />Phone: 312.756.7778 <br />info@sevansolutions.com www.sevansolutions.com <br />Regional Office: <br />37704 Hills Tech Drive <br />Farmington Hills, MI 48331 <br />INTEGRITY I RESPECT I TEAMWORK I EXCELLENCE I CHARITY <br />_ � -REVISIONS <br />NO. DATE DESCRIPTION <br />1 11/04/20 OWNER/PEER REVIEW COMMENTS <br />DICKERSONENGINEERING, INC. <br />Professional Electrical Engineers <br />3343 NORTH RIDGE AVENUE <br />ARLINGTON HEIGHTS, IL 60004 <br />TEL (°47) 966-0290 <br />WWW.DEI—PECOM <br />SEAL <br />AV. DIck <br />w tp <br />.max <br />i <br />q� 3 6369 <br />f t,/ <br />. EX RES O rJ�. O S/ L O <br />SIGNATURE <br />11/04/2020 <br />DATE <br />I CUSTOMER I I <br />PROJECT DESCRIPTION <br />' <br />1 9I <br />1 PROJECT LOCATION I. <br />607 SE EVERETT MALL <br />1 <br />EVERETT, WA 1. <br />I I SHEET TITLE I I <br />in t 11 <br />1101 <br />SHEET MANAGEMENT <br />PROJECT NO.: 41564 <br />DATE ISSUED: 08-10-20 <br />DRAWN BY: SR <br />REVIEWED BY: DD <br />THIS DOCUMENT IS AND SHALL REMAIN THE PROPERTY OF <br />SEVAN MULTI -SITE SOLUTIONS, INC. <br />REPRODUCTION ORALTERATION OF THIS DOCUMENT WITHOUT THE EXPRESSED <br />WRITTEN PERMISSION OF SEVAN MULTI -SITE SOLUTIONS, INC. IS PROHIBITED. <br />(NOT PUBLISHED: ALL RIGHTS RESERVED. <br />COPYRIGHT BYSEVAN MULTI -SITE SOLUTIONS, INC. 2013 <br />I I SHEET NUMBER I I <br />rG , <br />z, 111. 11 1 1.— — 11 <br />WM <br />