My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10611 EVERGREEN WAY 2017 KLEIN HONDA Plans 2022-10-27
>
Address Records
>
EVERGREEN WAY
>
10611
>
KLEIN HONDA
>
Plans
>
10611 EVERGREEN WAY 2017 KLEIN HONDA Plans 2022-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2022 9:40:03 AM
Creation date
10/24/2022 11:28:44 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
10611
Tenant Name
KLEIN HONDA
Permit
B1711-029
Year
2017
Notes
ADDITION TO SHOWROOM AND SERVICE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPEGIAL INSPECTION <br />5EE NOTES 1 2 <br />CONTINUOUS <br />PERIODIC <br />REMARKS <br />FOUNDATION <br />I <br />EXCAVATION, GRADING AND FILL <br />X <br />BY 6EOTECHNI6AL ENGINEER <br />2 <br />FINAL FOUNDATION PREPARATION <br />X <br />BY GEOTECHNICAL ENGINEER <br />5 <br />PLACEMENT OF FOUNDATION AND RETAINING WALL BA( KFILL <br />X <br />BY GEOTEOHNICAL ENGINEER <br />4 <br />INSTALLATION OF AGGREGATE FOUNDATION SYSTEM <br />X <br />BY 6EOTECHNICAL ENGINEER <br />CONCRETE <br />I <br />INSPECTION OF REINFORCING STEEL, INCLUDING PLACEMENT <br />X <br />2 <br />INSPECTION OF REINFORCING STEEL WELDING IN ACCORDANCE <br />WITH STEEL ITEM 5b BELOW <br />5 <br />IN5PEGT BOLT5 TO BE INSTALLED IN CONCRETE PRIOR TO <br />AND DURING PLACEMENT OF CONCRETE INHERE ALLOWABLE <br />LOAD5 HAVE BEEN I NCREA5ED <br />X <br />4 <br />VERIFYING U5E OF REQUIRED DESIGN MIX <br />X <br />5 <br />AT THE TIME FRE5H CONCRETE 15 SAMPLED TO FABRICATE <br />SPECIMENS FOR STRENGTH TE5T5, PERFORM SLUMP AND <br />AIR CON TENT TE5T5, AND DETERMINE THE TEMPERATURE <br />OF THE CONCRETE <br />X <br />6 <br />INSPECTION OF CONCRETE AND 5HOTCRETE PLACEMENT FOR <br />PROPER APPLICATION TE6HNIQUE5 <br />X <br />i <br />INSPECTION FOR MAINTENANCE OF SPECIFIED CURIN6 <br />TEMPERATURE AND TECHNIQUES <br />X <br />b <br />INSPECTION OF EMBED PLATES, BOLT5, AND OTHER EMBEDDED <br />ITEM5 PRIOR TO AND DURING PLACEMENT OF CONCRETE <br />X <br />DRILLED IN <br />I <br />PLACEMENT OF ADHE51 VE ANCHORS, ROD5 AND DOWELS <br />X <br />SEE NOTE 3 <br />ANCHORS <br />2 <br />PLACEMENT OF EXPANSION AND 56REW ANGHOR5 <br />X <br />SEE NOTE 5 <br />5TRU6TU L <br />MASONRY <br />I <br />A5 MASONRY CON5TRUCTION BEGINS, THE FOLLOWING <br />5HA.LL BE VERIFIED TO ENSURE COMPLIANCE: <br />�. PROPORTI ON5 OF 51 TE-PREPARED MORTAR <br />X <br />b. CONSTRUCTION OF MORTAR JOINT 5 <br />X <br />(,. LOCATION OF REINFORCEMENT AND OONNE6TOR5 <br />X <br />2 <br />THE INSPECTION PROGRAM SHALL VERIFY: <br />a. 51 ZE AND LOCATION OF STRUCTURAL ELEMENTS <br />X <br />b. TYPE, 51ZE AND L06ATION OF ANGHOR5, INCLUDING <br />OTHER DETAILS OF ANCHORAGE OF MA50NRY TO <br />5TUCTURAL MEMBERS, FRAMES OR OTHER <br />CONSTRUCTION <br />X <br />c. 5PEG IF I ED 51 ZE, GRADE AND TYPE OF REINFORCEMENT <br />X <br />d. WELDING OF REINFORCING BAR5 <br />X <br />o. PROTECTION OF MA50NRY DURING COLD <br />WEATHER (TEMPERATURE BELOW 40°F) OR <br />HOT WEATHER (TEMPERATURE ABOVE qO®F) <br />X <br />ANCHOR BOLT5 AND EMBEDS <br />5 <br />PRIOR TO GROUTING, THE FOLLOWING SHALL BE <br />VERIFIED TO ENSURE COMPLIANCE: <br />a. GROUT SPACE 15 CLEAN <br />X <br />b. PLACEMENT OF REINFORCEMENT AND CONNECTORS <br />X <br />c. PROPORTIONS OF 51TE-PREPARED GROUT AND <br />X <br />�. CONSTRUCTION OF MORTAR JOINTS <br />X <br />4 <br />GROUT PLACEMENT SHALL BE VERIFIED TO ENSURE <br />COMPLIANCE WITH CODE AND CONSTRUCTION <br />DOCUMENT PROV151ON5 <br />X <br />5 <br />PREPARATION OF ANY REQUIRED GROUT 5PECIMEN5, <br />MORTAR 5PE61MEN5 AND/OR PRISMS SHALL BE OBSERVED <br />X <br />6 <br />COMPLIANCE WITH REQUIRED INSPECTION PROVISIONS OF <br />THE GONSTRUGTION DOCUMENT5 AND THE APPROVED <br />SUBMITTALS SHALL BE VERIFIED <br />X <br />1 <br />WECIAL INSPECTION T® <br />5TRU6TURAL STEEL <br />I <br />MATERIAL VERIFICATION OF HIGH -STRENGTH BOLT5, NUTS <br />AND WASHERS: <br />�. IDENTIFICATION MARKINGS TO CONFORM TO A5TM <br />X <br />STANDARDS SPECIFIED IN THE APPROVED <br />6ON5 T RUCTION DOCUMENTS <br />b. MANUFACTURER'5 CERTIFICATE OF COMPLIANCE REQUIRED <br />X <br />2 <br />INSPECTION OF HIGH -STRENGTH BOLTING: <br />a. BEARIN(5-TYPE CONNECTIONS <br />X <br />b. SLIP®GRITICA;L 6ONNE6TION5 <br />X <br />X <br />5EE A156 560-05 <br />SECTIONS M25 AND M5.4 <br />3 <br />t MATERIAL VERIFICATION OF STRUCTURAL STEEL: <br />�. IDENTIFICATION MARKINGS TO CONFORM TO A5TM <br />STANDARDS 5PECIFID IN THE APPROVED <br />6ON5TRUGTION DOCUMENTS <br />b. MANUFACTURERS CERTIFIED MILL TE5T REPORTS <br />4 <br />MATERIAL VERIFICATION OF WELD FILLER MATERIALS: <br />�. IDENTIF16ATION MARKINGS TO CONFORM TO AWS <br />SPECIFICATION IN THE APPROVED CONSTRUCTION <br />DOCUMENTS <br />b. MANUFACTURER'S CERTIFICATE OF COMPLIANCE REQUIRED <br />INSPECTION OF 1/4ELDIN61 <br />�. STRUCTURAL STEEL: <br />1) COMPLETE AND PARTIAL PENETRATION GROOVE <br />X <br />5EE NOTE 4 <br />WELD5 <br />2) MULTIPA55 FILLET IAIELD5 <br />X <br />5) 51NGLE-PA55 FILLET WELD5 > 5/16" <br />X <br />4) SINGLE -PASS FILLET INELD5 < /16" <br />X <br />5EE NOTE 5 <br />5) FLOOR AND DECK WELDS <br />X <br />SEE NOTE 5 <br />b. REINFORCING 5TEEL: <br />1) VERIFICATION OF WELDABILITY OF REINFORCING <br />X <br />STEEL OTHER THAN A5TM A 106 <br />2) REINFORCING 5TEEL-RE515TIN6 FLEXURAL AND <br />X <br />AXIAL FORCES IN INTERMEDIATE AND SPECIAL <br />MOMENT FRAMES, AND BOUNDARY ELEMENTS OF <br />SPECIAL REINFORCED CON( RE T E 5HEAR <br />WALL5 AND 5HEAR REINFORCEMENT <br />5) SHEAR REINFORCEMENT <br />X <br />4) OTHER REINFORCING STEEL <br />X <br />�. OTHER WELDING: <br />1) ANCHORS ,AND STUDS <br />X <br />2) STAIR/ ILIN6 SYSTEMS <br />X <br />3) METAL DECK <br />X <br />4) LIGHT GAGE METAL FRAMING <br />X <br />6 <br />INSPECTION OF STEEL FRAME JOINT DETAILS FOR <br />X <br />GOMPLIANGE WITH APPROVED CON TRUGTION DOCUMENT5: <br />a. DETAILS SUCH Aa5 BRACING AND STIFFENING <br />b. MEMBER LOCATIONS <br />�. APPLICATION OF JOINT DETAILS AT EACH CONNECTION <br />OPEN -WEB STEEL <br />I <br />INSTALLATION OF OPEN -WEB STEEL J015T5 AND JOINT <br />JOISTS AND J015T <br />GIRDERS <br />61RDER5 <br />a. END CONNECTION5 ® WELDING OR BOLTED <br />X <br />5J1 SPECIFICATIONS <br />L15TED IN 5EGTION 2201.1 <br />b. BRIDGING ® HORIZONTAL OR DIACONAL <br />X <br />1) 5TANDARD BRIDGING <br />X <br />5J1 5PECIFICATION5 <br />LISTED IN SECTION 2201.1 <br />2) BRI06ING THAT DIFFERS FROM THE 5J1 <br />X <br />SPECIFICATIONS LISTED IN SECTION 2201.1 <br />COLD FRAMED <br />I <br />WELDING <br />X <br />STEEL FRAMING <br />2 <br />56REW ATTACHMENT, BOLTING, ANCHORING, AND OTHER <br />X <br />FA5TENIN6 OF COMPONENTS WITHIN THE <br />5E15M16-FORGE-R.E515TING SYSTEM, INCLUDING 5TRUT5, <br />BRACES AND HOLDOWN5 <br />ARCHITECTURAL <br />I <br />DURING ERECTION AND FA5TENIN6 OF EXTERIOR CLADDING, <br />X <br />5EE NOTE <br />COMPONENTS <br />INTERIOR NON-BEARIN6 WALL5, AND INTERIOR AND <br />EXTERIOR VENEER <br />MECHANICAL AND <br />I <br />DURING ANCHORAGE OF ELECTRICAL EQUIPMENT FOR <br />X <br />ELECTRICAL <br />EMERGENCY OR STANDBY POWER SYSTEMS <br />COMPONENTS <br />2 <br />DURING INSTALLATION OF PIPING 5Y5TEM5 INTENDED TO <br />X <br />CARRY FLAMMABLE, COMBUSTIBLE OR HIGHLY TOXIC <br />CONTENTS AND THEIR A55061ATED MECHANICAL UNIT5 <br />APPROVED <br />I <br />APPROVED FABRICATORS MU5T SUBMIT <br />FADRI6ATOR5 <br />CERTIFIGA T E OF COMPLIANCE FOR ALL <br />OFF5ITE FAR16AtTO5 SUCH A5 5TRUCTURAL <br />STEEL, GLULAM5, PRECAST CONCRETE, ETC, <br />PREFABR16ATED <br />I <br />SEE NOTE 6 <br />6ON5TRU6 T ION <br />5. IN5PECTION OF DRILLED AN( HOR5, INCLUDING EXPAN-51ON AND <br />V15UAL VERIFICATION OF DRILLED HOLE DEPTH, 5PA( IN6, EDGE <br />015TAN6E5 AND HOLE CLEANING. FOR GROUTED ANCHOR5, <br />GROUT IN13TALLATION 5HALL BE 065ERVED AND GROUT <br />PRODUCT 5FE61FICATION <br />D PREPARATION <br />"' 1. 1 SHALL B <br />4. ALL COMPLETE PENETRATION YiEL05 5HALL BE TESTED <br />ANOTHER APPROVED METHOD. <br />. ALL WELD5 SHALL BE VISUALLY INSPECTED, <br />6. INSPECTION OF PREFABRICATED CONSTRUCTION SHALL BE THE <br />SAME A5 IF THE MATERIAL U5ED IN THE CONSTRUCTION TOOK <br />PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED <br />DURING PREFABRICATION IF THE APPROVED AGENCY CERTIFIES <br />THE 60115TRUCTION AND FURN15HE5 EVIDENCE OF COMPLIANCE. <br />1. EX6EPTION5: FA5TENINC? OF WOOD 5HEATHIN6 U5ED FOR WOOD <br />SHEAR WALL5, SHEAR PANELS, AND DIAPHRAGMS WHERE <br />FASTENER SPACING 15 MORE THAN 4" ON CENTER. <br />e). EXCEPTIONS: <br />a) 5PEGIAL INSPECTION 15 NOT REQUIRED FOR ARCHITECTURAL <br />6OMPONENT5 IN STRUCTURES 50 FEET OR LE55 IN HEIGHT. <br />b) CLADDING AND VENEER WEIGHING 5 P5F OR LE55. <br />a) INTERIOR NON -BEARING WALL5 WEIGHING 15 P5F OR LE55. <br />CITY Y EVER TT <br />REVIEWED ED FOR PERMIT <br />0 <br />0 <br />z <br />90 <br />o <br />� <br />0- <br />v-W <br />
The URL can be used to link to this page
Your browser does not support the video tag.