Laserfiche WebLink
PLAN NOTES: <br />1, ALL DIMENSIONS ARE APPROXIMATE TO FACE OF STUD FRAMING. CONTRACTOR 5HALL FIELD VERIFY ALL <br />DIMEN6ION5 PRIOR TO FABRICATION 4 CONSTRUCTION, <br />2. ALL VENT FANS 5HALL TERMINATE AT THE EXTERIOR OF 11 HE BLDG. IN5ULATE ALL DUCTS OUTSIDE OF <br />CONDITIONED SPACE. <br />3. 0 5D DENOTES APPROXIMATE HARD -WIRED SMOKE DETECTOR LOCATIONS. REFERENCE IRC SECTION R313 <br />FOR ADD'L- LOCATIONS 4 INSTALLATION INFO. <br />4, SAFETY GLASS IS REQUIRED PER IRC SECTION R300.4. <br />Ea, MAINTAIN EXISTING ROOF VENTILATION SYSTEM. <br />6, ALL WOOD FRAMING WITH SURFACE CHAR LE55 THAN /$" MAY REMAIN IN PLACE PROVIDED IT 15 CLEANED BY <br />MECHANICAL. MEANS AND SMOKE SEALED. ANY WOOD FRAMING WITH DAMAGE GREATER. THAN 115" MU5T BE <br />REMOVED AND REPLACED IN -LIKE KIND TO MATCH EXISTING SIZE # SPACING Ul DOUG-FIR "l OR 13ETTER UNO <br />i. ALL WOOD FRAMING THAT 16 FOUND TO 5E SPLIT, FRACTURED, MISSING ANY PORTION OF ITS CRO55-5ECTION <br />OR OTHERWISE MATERIALLY DEFORMED OR OUT -OF -PLUMS SHALL BE REMOVED 4 REPLACED WITH NEW <br />FRAMING OF LIME KIND AND SIZE TO MATCH EXISTING. USE MIN DOUG-FIR "1 OR BETTER UNO ON PLANS. <br />8, PROVIDE NEW KRAFT-FACED R-49 BATT INSULATION AT ATTIC 5PACES, NEW HIGH -DENSITY BATT INSULATION <br />AT VAULTED ROOF RAFTERS TO FILL EXISTING CAVITY LE55 1" AIRSPACE 4 NEW KRAFT-FACED R-1rp <br />INSULATION AT 2x4 EX15T EXTERIOR UJALL5. FOR FLOOR5 OVER CRAWLSPACE OR OTHER UNCONDITIONED <br />5PACE6, PROVIDE NEW BATT FLOOR INSULATION TO FILL EXISTING J015T CAVITIES. IN LIEU OF USING <br />KRAFT-FACED BAT T S WHERE INDICATED ABOVE, UNFACED BATTS MAY BE USED PROVIDED THAT A VAPOR <br />RETARDING PRIMER OR FINISH PAINT WITH A PERMEABILITY RATING OF LESS THAN OR EQUAL TO 1.0 MAY BE <br />USED, <br />9. ALL NEW GLAZING SHALL MEET MAX. U = 0.30 (VERT) AND U = 0.50 (OVERHEAD). <br />10. ALL NEW EXTERIOR DOORS SHALL BE MAX. U a 0,30. <br />11, EGRESS WINDOWS SHALL BE VERIFIED TO HAVE A MAX, 5ILL HEIGHT = 44" A50VE FLOOR ELEVATION AND A <br />MIN. NET CLEAR OPENING = 5,`1 SF (5.0 5F AT GRADE LEVEL) W1 MIN. OPENING WIDTH e 20" 4 MIN, OPENING HT = <br />24". PROVIDE NEW EGRESS WINDOWS AS REQ'D IF CONDITIONS ABOVE NOT MET, <br />12. MECHANICAL CONTRACTOR TO PROVIDE W5EC WORKSHEETS TO SIZE NEW ELECTRIC 5A5EE30ARD OR OTHER <br />HEAT SYSTEM TO REPLACE EXISTING BA5E5OARD HEAT FOR MECHANICAL PERMIT SU5MITTA.L TO THE CITY <br />OF EVERETT. <br />3 1'-2" <br />I <br />CITY C F EEI s` <br />REVIEWED FOR PERIIMIT <br />c47 <br />t— <br />Z <br />C) <br />0 <br />m <br />5 <br />W <br />f--- <br />u <br />Lu <br />ct� <br />l <br />w <br />« <br />m <br />Lnmm <br />Ono <br />wto <br />M6 <br />wee <br />J <br />C� <br />EJ <br />0 <br />Y L° <br />w <br />3 � <br />Ld <br />