Laserfiche WebLink
I D I <br />CI <br />DI <br />IA <br />1 1 2 <br />ORIENTATION PLAN - Shoreside - Bldq. 7 <br />0 20' 40' 80, <br />NORTH Scale: 1°' = 40' <br />F____ ___ - __ __ - __ __ ___ __1 <br />� BEVERLY <br />� LAKE <br />BLDG.5 i <br />BLDG.B <br />BLDG. 3 <br />1 3 <br />GENERAL NOTES <br />1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE THE WORK OF <br />ALL TRADES INVOLVED IN THE PROJECT AS PART OF THIS CONTRACT. <br />2. DO NOT SCALE DRAWINGS. DUE TO REPROGRAPHIC PROCESSES DRAWINGS <br />MAY NOT BE TO SCALE. CONTACT ARCHITECT FOR ANY NEEDED <br />CLARIFICATION. <br />3. CONTRACTOR SHALL VERIFY CONDITIONS AT THE SITE AND REPORT ALL <br />DISCREPANCIES TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. <br />4. CONTRACTOR SHALL PROVIDE A COMPLETE AND PROPER EXECUTION OF THE <br />WORK AS INDICATED ON ALL DRAWINGS AND SPECIFICATIONS. IF <br />DISCREPANCIES IN LAYOUT, DIMENSIONS, OR DETAILS ARE FOUND BETWEEN <br />ARCHITECTURAL, STRUCTURAL, CIVIL OR LANDSCAPE DRAWINGS, CONTACT <br />THE ARCHITECT IMMEDIATELY FOR CLARIFICATION BEFORE PROCEEDING. <br />5. REGULATIONS, STANDARDS, CONSTRUCTION, MATERIALS AND REQUIREMENTS <br />FOR INSTALLATION OF MATERIALS SHALL CONFORM AND BE GOVERNED BY THE <br />EDITION OF THE CODE IDENTIFIED IN THESE DRAWINGS. <br />6. N.I.C. EQUIPMENT IS FURNISHED AND INSTALLED BY OTHERS. CONTRACTOR IS <br />RESPONSIBLE FOR COORDINATION INSTALLATION AND PERFORMING WORK AS <br />REQUIRED BY DETAILS OR SPECIFICATIONS FOR EQUIPMENT INSTALLATION. <br />7. F.O.I.C. EQUIPMENT IS FURNISHED BY OWNER AND INSTALLED AS PART OF THIS <br />WORK. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK AS <br />REQUIRED FOR INSTALLATION. <br />8. CONTRACTOR SHALL SEAL AROUND ALL PENETRATIONS FOR FIRE RATED <br />WALLS, INCLUDING, BUT NOT LIMITED TO PIPING, DUCT, CONDUIT, ETC. WITH <br />FIRE STOPPING PER CODES THAT GOVERN THIS SET OF DOCUMENTS. <br />9. CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER <br />MEMBRANE AT THE FLOOR SLAB, WALLS, AND ROOF. BACKER ROD, SEALANT <br />AND OTHER APPROVED MEANS SHALL BE APPLIED CONTINUOUSLY AROUND ALL <br />EXTERIOR DOORS AND WINDOW PENETRATIONS AND OTHER AREAS OF <br />POTENTIAL AIR INFILTRATION, INCLUDING STRUCTURAL, MECHANICAL AND <br />ELECTRICAL PENETRATIONS. THE CONTRACTOR SHALL REPAIR ANY DAMAGE <br />TO VAPOR BARRIER, OR REPLACE THEM PRIOR TO COVER, AS APPROVED. <br />10. THERMAL AND SOUND INSULATION IS INTENDED TO PROVIDE A CONTINUOUS <br />ENVELOPE AS INDICATED. <br />11. TYPE A FIXTURES SHALL MEET THE REQUIREMENTS OF THE CODES THAT <br />GOVERN THIS SET OF DOCUMENTS. <br />12. IT SHALL BE THE DUTY AND RESPONSIBILITY OF EACH TRADE AND SUPPLIER TO <br />EXAMINE ALL PROJECT DRAWINGS, DETAILS AND SPECIFICATIONS, AND TO <br />PROVIDE AND FURNISH PROPER EQUIPMENT, HARDWARE, FIXTURES, <br />MATERIALS, ETC., PERTAINING TO THEIR PART OF THE WORK SHOWN OR <br />LISTED IN ANY PART OF THESE DOCUMENTS. <br />13. QUALITY CONTROL, ADVERSE MATERIAL REACTIONS, AND COMPLIANCE TO <br />INDUSTRY STANDARD WORKMANSHIP ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR. SCHEDULES ARE FOR THE CONVENIENCE OF THE CONTRACTOR <br />TO ASSIST THEM IN UNDERSTANDING AND CONSTRUCTING THE PROJECT. <br />14. ANY OMISSIONS OR CONTRADICTIONS IN THESE DOCUMENTS SHALL BE CALLED <br />TO THE ATTENTION OF THE ARCHITECT. <br />15. INSTALLERS ARE TO BE CERTIFIED BY MANUFACTURER'S APPROVED <br />WARRANTY REQUIREMENTS. <br />16. ALL WOOD IN CONTACT WITH CMU, CONCRETE OR SOIL SHALL BE PRESSURE <br />TREATED, TYP, LION. <br />FIRE RATED ASSEMBLIES <br />MEMBRANE PENETRATIONS AT FIRE RATED WALLS PER IBC 714.4 <br />PROVIDE APPROVED FIRE RESISTIVE PUTTY PADS AT ALL ELECTRICAL BOXES, <br />AND INSTALL PER MANUFACTURER'S RECOMMENDATIONS. <br />PROVIDE APPROVED FIRE CAULKING AT ALL WIRE, PIPE, AND OTHER MEMBRANE <br />PENETRATIONS. <br />PENETRATIONS AT FIRE RATED HORIZONTAL ASSEMBLIES (FLOORS), PER IBC <br />714.5: <br />PROVIDE APPROVED FIRE CAULKING AT ALL PIPES, DRAINS, AND CONDUITS <br />PENETRATING FLOOR ASSEMBLIES. CONFIRM ANNULAR SPACE, COMPATIBILITY <br />OF MATERIALS, AND APPLICATION LIMITATIONS WITH MANUNFACTURER'S <br />LITERATURE. <br />CONCEALED SPACES, PER IBC 718: <br />PROVIDE FIREBLOCKING AT 10' O.C. INSIDE DOUBLE STUD UNIT SEPARATION <br />WALLS, AND OTHER COMBUSTIBLE ENCLOSED SPACES. FIREBLOCKING SHALL <br />CONSIST OF EITHER: <br />• BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER OR UNFACED <br />FIBERGLASS TO FILL THE ENTIRE CAVITY AT 10' O.C. <br />• AT SOFFITS, AND OTHER ENCLOSED SPACES, PROVIDE FIREBLOCKING <br />AT 10' INTERVALS, AND TO SEPARATE SOFFITS FROM WALLS, OR <br />FLOORS. <br />• PROVIDE 5/8" TYPE X WATER RESISTIVE GWB BETWEEN TUBS AND FIRE <br />RATED ASSEMBLIES. <br />WOOD WALL MODIFICATIONS <br />NON -LOAD BEARING WALLS (PARTY WALLS AT THE UPPER FLOOR LEVEL) <br />• FOR NOTCHES LESS THAN 40% NO MODIFICATIONS ARE <br />REQUIRED. THIS IS UP TO 1.4" NOTCH FOR A 2X4 STUD. <br />• FOR NOTCHES OVER 40% THE STUDS SHALL BE REINFORCED WITH <br />SIMPSON LSTA9 STRAP ALONG THE NOTCHED EDGE. <br />• BORED HOLES UP TO 1 W DIAMETER ARE ALLOWED WITHOUT <br />UPGRADES PROVIDED THEY ARE CENTERED WITHIN THE 2X4 STUD. <br />• STUDS FULLY REMOVED SHALL BE REPLACED IN KIND WITH N <br />LOAD BEARING WALLS (ASSUMED TO BE THE PARTY WALLS AT THE GROUND <br />FLOOR LEVEL): <br />• FOR NOTCHES LESS THAN 25% NO MODIFICATIONS ARE <br />REQUIRED. THIS IS UP TO 0.9" NOTCH FOR A 2X4 STUD. <br />• FOR NOTCHES GREATER THAN 25% STUDS SHALL BE REINFORCED <br />WITH SIMPSON HSS2-SDS1.5 (STUD SHOE). <br />• FOR NOTCHES GREATER THAN 25% WHERE THE STUD SHOE WILL NOT <br />FIT (IF EITHER THE DEPTH OR WIDTH OF THE NOTCH IS GREATER THAN <br />2-3/8") THEN A NEW FULL -HEIGHT 2X4 HF STUD SHALL BE ADDED <br />ADJACENT & PERPENDICULAR TO THE NOTCHED STUD. THE NEW STUD <br />SHALL BE FASTENED TO THE NOTCHED STUD WITH 10D NAILS @ 12" <br />OC. <br />• BORED HOLES UP TO 1W DIAMETER ARE ALLOWED WITHOUT <br />UPGRADES PROVIDED THEY ARE CENTERED WITHIN THE 2X4 STUD. <br />FOR CONDITIONS OTHER THAN THE ONES STATED ABOVE, PLEASE HAVE THE <br />CONTRACTOR SHALL CONTACT THE ARCHITECT OR STRUCTURAL <br />ENGINEER. WALLS AT ALL OTHER LOCATIONS SHOULD BE ASSUMED TO BE <br />BEARING UNLESS CONFIRMED NON -BEARING BY A STRUCTURAL ENGINEER. <br />1 4 1 5 <br />EXISTING BUILDING PROJECT DESCRIPTION <br />Code Information <br />ALTERATIONS PROPOSED IN THIS PROJECT SHALL MEET THE PRESCRIPTIVE PROJECT LOCATION 701 75th Street SE, Everett, WA 98203 <br />COMPLIANCE MEASURES FOR LEVEL 2 ALTERATIONS DESCRIBED IN CHAPTERS 7 PROJECT DESCRIPTION: <br />AND 8 OF THE INTERNATIONAL EXISTING BUILDING CODE. <br />IN GENERAL, EXISTING MATERIALS AND SYSTEMS SHALL BE ALLOWED TO INTERIOR RENOVATIONS TO RESIDENTIAL UNITS. WORK TO INCLUDE NEW FLOOR <br />REMAIN IN PLACE. ALTERATIONS ( NEW SYSTEMS AND MATERIALS) SHALL MEET FINISHES, CABINETS, PLUMBING FIXTURES AND APPLIANCES. WORK MAY INCLUDE <br />REQUIREMENTS OF IEBC, IBC, AND OTHER APPLICABLE CODES. INCIDENTAL MODIFICATIONS TO EXISTING BEARING OR RESIDENTIAL UNIT <br />SEPARATION WALLS. <br />ALTERATIONS SHALL MEET ACCESSIBILITY REQUIREMENTS OF IEBC SECTION <br />305.6, AND IBC CHAPTER 11. <br />IEBC 702.1 INTERIOR FINISHES: WALL AND CEILING FINISHES, PER IBC TABLE <br />803.13: SHALL MEET CLASS C FLAME SPREAD INDEX 76-200; SMOKE -DEVELOPED <br />INDEX 0-450, PER ASTM E84 OR UL 723 SITE INFORMATION Permit#: 82203-016 <br />Site Address: 70175TH ST BLDG 7 <br />IEBC 702.3 AND IBC 806.7 INTERIOR TRIM SHALL BE CLASS C. Owner: SHORESIDE 51 LLC <br />Tenant: BLDG 7 <br />IEBC 702.4 OPENING CONTROL DEVICES ON REPLACEMENT WINDOWS: NOT Property Address: 625 and 701 75th St.SE, Everett, WA 98203 App. Date: 3/3f2022 <br />APPLICABLE.- NO WINDOWS ARE SCHEDULED FOR REPLACEMENT. <br />Owner: Williams Investments Proposed Use: COMMERCIAL ALTERATIONS <br />IEBC 702.5 REPLACEMENT WINDOW EMERGENCY ESCAPE OPENINGS: NOT Owner Address: Description: REMODEL UNITS 722,725 <br />APPLICABLE- NO WINDOWS ARE TO BE REPLACED. <br />Owner Phone: 41 tjj%4 <br />IEBC 702.6 MATERIALS AND METHODS. NEW WORK SHALL COMPLY WITH Reviewed By: Date: <br />PROVISIONS OF APPLICABLE IBC, IMC, [PC, AND OTHER CODES. Parcel Size: 174,000 SF (3.99 Acres) <br />� .Office Set Jab Site Set Fire/Planning Set <br />IEBC 703. FIRE PROTECTION: ALTERATIONS SHALL BE DONE IN A MANER THAT Zoning Area: UR-3 (Urban Residential - 3 story) <br />MAINTAINS THE LEVEL OF FIRE PROTECTION PROVIDED. 137- Multi Family Residential 100 - 200 units. <br />IEBC 704. MEANS OF EGRESS: NO ALTERATIONS TO MEANS OF EGRESS ARE Actual Lot Length: +/- 580a I I �:�C1[+7�:�Gl1[�l►E'�/_\PIM <br />PROPOSED. V <br />Actual Lot Width: +/- 300' <br />IEBC 705 REROOFING: NO REROOFING IS PROPOSED. D w.(I <br />Q6 1 J f°b�fi� ry 9552 <br />TERED <br />IEBC 706 STRUCTURAL: NO ADDITIONAL LOAD IMPACTING EQUIMPMENT IS GOVERNING CODES ARCHITECT <br />!;��:�"� ARCHITECT <br />PROPOSED. CITY Off" +;V <br />IEBC 707 ENERGY CONSERVATION: ALTERATIONS SHALL COMPLY WITH WSEC 2018 INTERNATIONAL EXISTING BUILDING CODE (IEBC) <br />F'erniIt Servlcs <br />51-11 R. (WASH. ST. AMENDMENT) 2018 INTERNATIONAL BUILDING CODE (IBC) CHA L AAON STEVENS <br />• 2018 INTERNATIONAL FIRE CODE (IFC) STATE OF WASHINGTON <br />IEBC 801 GENERAL NEW CONSTRUCTION ELEMENTS, SYSTEMS, AND 2018 INTERNATIONAL PLUMBING CODE (IPC) <br />COMPONENTS SHALL COMPLY WITH REQUIREMENTS OF THE IBC. 2018 WASHINGTON STATE ENERGY CODE (WSEC) <br />• NFPA 72 - NATIONAL FIRE ALARM AND SIGNALLING CODE <br />IEBC 803 FIRE PROTECTION: <br />EXISTING FIRE ALARM AND DETECTION SYSTEM SHALL BE MAINTAINED. PROJECT IDENTIFICATION: <br />EXISTING CARBON MONOXIDE DETECTION SYSTEM SHALL BE MAINTAINED. SEPARATE PERMITS SUBMITTALS <br />IEBC 805 MEANS OF EGRESS: NO CHANGES PROPOSED. <br />IEBC 806 STRUCTURAL: NO CHANGES PROPOSED. MECHANICAL <br />ELECTRICAL <br />IEBC 807 ELECTRICAL: EQUIPMENT AND WIRING INSTALLED IN THE WORK AREA PLUMBING <br />SHALL COMPLY WITH NFPA 70. FIRE ALARM <br />IEBC 808 MECHANICAL: NO CONVERTED SPACES PROPOSED. NO ALTERATIONS <br />TO EXISTING SYSTEMS PROPOSED. <br />IEBC 811.1 ENERGY CONSERVATION: LEVEL 2 ALTERATIONS SHALL COMPLY <br />WITH WSEC 51-11 R (WASH. ST. AMENDMENT) BUILDING INFORMATION <br />ENERGY COMPLIANCE INFORMATION <br />PER WSEC R503, ALTERATIONS SHALL BE SUCH THAT THE BUILDING IS NO LESS <br />CONFORMING THAN IT WAS PRIOR TO THE ALTERATION. <br />R503.1.1 BUILDING ENVELOPE: ALTERATIONS SHALL NOT AFFECT BUILDING <br />ENVELOPE ASSEMBLIES. <br />R503.1.1.1 WINDOW REPLACEMENT: WINDOW REPLACEMENT IS NOT APART OF <br />THIS PROJECT. <br />R503.1.2 HEATING AND COOLING SYSTEMS: NEW HEATING AND COOLING <br />SYSTEMS ARE NOT A PART OF THIS PROJECT, <br />R503.1.4 LIGHTING: NEW LIGHITING SYSTEMS SHALL COMPLY WITH SECTION <br />404.1 (90% OF LAMPS SHALL BE HIGH -EFFICACY LAMPS) <br />RE /E ry OF EVERE7' <br />WED FOR P i <br />Additional Permits Are Require Mr� <br />For This Project To Include: <br />[�] Plumbing E] sprinkler <br />C Mechanical Fire Alarm <br />FleCtr!0al <br />Smoke Detectors Required: <br />• In each sleeping room, <br />• In each room giving access to a <br />sleeping room, <br />* Interconnected, <br />• Battery backup, <br />• Hardwired. <br />THESE DOCUMENTS HAVE NOT BEEN <br />APPROVED FOR THE ISSUANCE OF <br />PUBLIC WORK, MECHANICAL, FIRE <br />SUPPRESSION, ELECTRICAL OR <br />PLUMBING PERMITS <br />NORTH <br />FIRE ALARM SYSTEM PROVIDED <br />CARBON MONOXIDE MONITORING SYSTEM PROVIDED <br />OCCUPANCY R2 <br />CONSTRUCTION TYPE V-N, NON-SPRINKLERED <br />(EXISTING): <br />**ALL ELECTRICAL, MECHANICAL, <br />PLUMBING, FRAMING INSTALLED OR <br />ALTERED WITHOUT PERMITS, OR <br />INSPECTION AND APPROVAL MUST <br />BE UNCOVERED FOR INSPECTION`* <br />VICINITY PLAN - NTS <br />00 <br />co <br />0 <br />N <br />N <br />N <br />O <br />N <br />co <br />N <br />N <br />Shoreside Village <br />Renovations Bldg.7 <br />FOR <br />Williams <br />Investments <br />AT <br />625 and 701 75th St.SE, <br />Everett, WA 98203 <br />Building Permit Set <br />This drawing is: <br />1. Copyright 2020 Dykeman, Inc. <br />2. The Architect's Instrument of Professional Service. <br />3. For use on this project only. Obtain Architect's <br />written permission for any other use or reproduction. <br />2021-035 <br />MARK DATE DESCRIPTION <br />PRINCIPAL IN CHARGE:1 MS <br />PROJECT MANAGER: DH <br />PROJECT ARCHITECT: 1 <br />JOB CAPTAIN: GM <br />PROJECT <br />INFORMATION <br />CI <br />nII <br />I <br />0 <br />0 <br />0 <br />5 <br />